PubMed Health⌕ Search

Biomedical subjects

K C Goodrich

Publications and source records attributed to K C Goodrich.

At least 19 recordsLinked to original sources

In vivo Hahn spin-echo decay (Hahn-T2) observation of regional changes in the time course of oleic acid lung injury.

We studied the time course of changes in the Hahn spin-echo decay (Hahn-T2) in lungs of spontaneously breathing living rats at 1 hour, 3 hours, and 7 days following oleic acid injection. Motion artifacts were minimized by using the motion-insensitive interleaved rapid line scan (ILS) imaging technique. Prior to injury, the lungs exhibited two resolvable exponential Hahn-T2 components. One and 3 hours after injury the decay showed a regionally nonuniform behavior, which was fit with one, two, or three exponential components. The short and medium components increased at 1 and 3 hours after injection. The third, much longer, component is probably due to intraalveolar pulmonary edema. After 7 days the Hahn decay was similar to that observed before injury, probably reflecting resolution of the edema. Our data suggest that Hahn-T2 measurements can be used to characterize the time course and regional distribution of lung injury in living animals.

Animals↗

A three-coil comparison for MR angiography.

The purpose of this work was to compare intracranial magnetic resonance angiography (MRA) image quality using three different radiofrequency coils. The three coil types included a reduced volume quadrature birdcage coil with endcap, a commercially available quadrature birdcage head coil, and a four-element phased-array coil. Signal-to-noise ratio (SNR) measurements were obtained from comparison studies performed on a uniform cylindrical phantom. MRA comparisons were performed using data acquired from 15 volunteers and applying a thick-slab three-dimensional time-of-flight sequence. Analysis was performed using the signal difference-to-noise ratio, a quantitative measure of the relative vascular signal. The reduced-volume endcap and phased-array coils, which were designed specifically for imaging the intracranial volume of the head, improved the image SNR and vascular detail considerably over that obtained using the commercially available head coil. The endcap coil configuration provided the best vascular signal overall, while the phased-array coil provided the best results for arteries close to the coil elements.

Brain↗

Magnetic resonance angiography with sliding interleaved projection reconstruction (SLIPR) acquisition.

In this paper, we report on the development of a novel multiple thin-slab projection-reconstruction acquisition technique. To eliminate the slab boundary artifact, the slabs are highly overlapped and only a small fraction of the projection view angles are sampled at each slab position. After Fourier transformation in the slice direction, there are sufficient numbers of projection measurements at each slice position to obtain very high resolution MR angiograms. The technique presented has all of the advantages of multiple overlapping thin slab acquisition (MOTSA) with no evidence of slab boundary artifact. J. Magn. Reson. Imaging 1999;10:569-575.

Artifacts↗

Optimized visualization of vessels in contrast enhanced intracranial MR angiography.

In this study, the problem of small vessel visualization in magnetic resonance angiography is addressed. The loss of vessel contrast due to slow flow-related signal saturation can be compensated by the T1 reduction obtained from the use of an MR contrast agent, such as Gd-DTPA. The vessel/background signal-difference-to-noise ratio (SDNR) is shown to strongly depend on the imaging parameters, as well as on the time course of the blood T1 values obtained from the contrast injection. Specifically, it was found that vessel SDNR increases almost linearly with TR, if the sampling bandwidth is reduced proportionately.

Artifacts↗

Contrast-enhanced magnetic resonance angiography of cerebral arteries. A review.

The loss of blood vessel visibility due to the signal saturation of slow flow can be partially overcome by the T1 reduction that occurs with the use of contrast agents such as Gd-DTPA during magnetic resonance angiography (MRA) studies. Dynamic-imaging techniques that have been applied successfully in abdominal imaging may also be useful for intracranial applications. However, the time between arterial and venous enhancement is very short during intracranial circulation. This limits the spatial resolution that can be obtained between arterial and venous enhancement. Fortunately, the blood-brain barrier and the relatively long duration of significant decrease in blood T1 has led to the development of very high resolution intracranial MRA techniques. Knowledge of the contrast-agent dilution factors and the ultimate resulting relaxation rates can be used to optimize the imaging parameters to maximize vessel signal relative to the background signal (the signal-difference-to-noise ratio). The additional venous vascular detail in the contrast-enhanced study can be spatially resolved in the 3D image data and determined by incorporating information from both high-resolution precontrast and postcontrast studies. In this article, the history, development and application of contrast agents in MRA are presented.

Cerebral Angiography↗

Observer performance methodologies for evaluating blood vessel visibility in MR angiograms using accurate geometric registration to high resolution x-ray angiograms.

Receiver operator characteristic (ROC) and two alternative forced choice (2AFC) methodologies for quantitatively assessing vessel visibility in MR angiography (MRA) were examined using x-ray angiography images as truth. The methodologies required MRA projection images with the same orientation and magnification as the x-ray images. Geometric distortions limited the quality of the registration. The observer performance measurements were compared to vessel contrast-to-noise ratio (CNR) measurements. Receiver bandwidth (RBW) and magnetization transfer (MT) effects in 3D time-of-flight MRA were evaluated. Overall, applying MT significantly increased all three measurements while decreasing the RBW significantly improved the 2AFC and CNR measurements. The relative importance of both effects on the 2AFC measure increased as vessel diameter decreased, although statistical significance was limited by small samples for diameters less than approximately 0.7 mm. These results demonstrate the usefulness of these observer performance methodologies for MRA technique assessment.

Angiography, Digital Subtraction↗

Velocity measurement based on bolus tracking with the aid of three-dimensional reconstruction from digital subtraction angiography.

The problem of blood flow measurement in x-ray angiography using measurements of the leading edge of the contrast bolus as it traverses the vascular bed is considered. A new technique for velocity measurement is presented based upon the ratio of the temporal derivative to the spatial derivative of the contrast bolus in the direction of flow. With the addition of a small correction factor, the value obtained is shown to reflect the transport velocity, or the velocity at which the contrast is transported down the vessel of interest. Most blood flow measurements based on bolus tracking techniques are actually using the contrast transport velocity to represent the blood flow velocity. Because of the streaming that occurs due to laminary flow conditions, the measured transport velocity is found to be somewhere between the average and the peak (central) fluid velocities for measurements taken during the traversal of the bolus leading edge. The spatial and temporal variation of the transport velocity are found to be consistent with the bolus motion expected in the presence of laminar flow. From x-ray images of contrast passage through simple tubes, we find that the derivative method measures the transport velocity during passage of the bolus leading edge. In most cases of laminar blood flow, the leading edge transport velocity can be 20%-40% higher than the average blood velocity.

Angiography, Digital Subtraction↗

Comparison of calculated and experimental NMR spectral broadening for lung tissue.

NMR lineshapes were calculated for a model of lung, and NMR proton spectra were measured for individual voxels in an excised inflated rat lung. NMR lines for parenchymal lung regions containing alveoli, alveolar ducts, and capillaries were calculated using a computer simulation of the NMR signal from a three-dimensional honeycomb-like structure, a collection of modified Wigner-Seitz cells. These cells were modified by rounding the corners and increasing the thickness of the boundaries to model various degrees of lung inflation and lung water. NMR lineshapes were also calculated for the central or nonparenchymal lung regions containing bronchi and large blood vessels. A comparison of theoretical lineshapes with those measured in individual voxels both in the parenchymal and in the central (largely nonparenchymal) regions in excised rat lungs at an inflation pressure of 30 cm of water shows excellent agreement. These results indicate that the NMR lineshape reflects the underlying lung geometry. This research constitutes the first calculations and measurements of NMR lineshapes in lung. The appendix describes a new method for calculating the magnetic field inside a weakly diamagnetic material of arbitrary shape placed in an otherwise uniform external magnetic field. This new method does not require either solution of simultaneous equations or evaluation of integral expressions.

Animals↗

Extension of the Rorschach--Hazlewood theoretical model for spin-lattice relaxation in biological systems to low frequencies.

The water-biopolymer cross-relaxation model, proposed by H. E. Rorschach and C. F. Hazlewood (RH) [J. Magn. Reson. 70, 79 (1986)], explains the Larmor frequency dependence of T1 in many biological systems. However, the RH theory fails at low Larmor frequencies. In this paper, a more general version of the RH theory has been developed. This theory is valid at all frequencies. Use of the new expression for the spin-lattice relaxation rate (1/T1), earlier published experimental data in H2O/D2O bovine serum albumin, which had been measured over a wide frequency range (10 kHz to 100 MHz), were fitted over the entire frequency range. The agreement between theory and the experimental data is excellent. Theoretical expressions for the rotating-frame spin-lattice relaxation rate (1/T1(rho)) were also obtained.

Algorithms↗

Application to rat lung of the extended Rorschach-Hazlewood model of spin-lattice relaxation.

The spin-lattice relaxation time T1 was measured in excised degassed (airless) rat lungs over the frequency range 6.7 to 80.5 MHz. The observed frequency dependence was fitted successfully to the water-biopolymer cross-relaxation theory proposed by H. E. Rorschach and C. F. Hazlewood (RH) [J. Magn. Reson. 70, 79 (1986)]. The rotating frame spin-lattice relaxation time T1(rho) was also measured in rat lung fragments over the frequency range 0.56 to 5.6 kHz, and the observed frequency dependence was explained with an extension of the RH model. The agreement between the theory and the experimental data in both cases is good.

Animals↗

A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population.

RATIONALE AND OBJECTIVES: The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. METHODS: Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. RESULTS: The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (< 0.5 mm) had the highest CNR, using the thick slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. CONCLUSIONS: Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.

Adult↗

The application of magnetization transfer to MR angiography with reduced total power.

Magnetization transfer (MT) techniques have been shown to significantly reduce background soft-tissue signal in time-of-flight magnetic resonance angiography. To achieve sufficient suppression, radio frequency (RF) pulses with tip angles on the order of 1000 degrees are typically used, resulting in significant RF power deposition in the patient. Although these power deposition levels do not exceed the FDA guidelines, they are significantly higher than those used in typical imaging techniques. The use of these same magnetization transfer pulses in applications at field strengths higher than 1.5 T will require MT power levels which exceed FDA safety standards. This report demonstrates that the total power deposition required to achieve background tissue suppression can be significantly reduced by the application of the saturation pulses only during the phase-encoding steps corresponding to the central portion of "k space." This technique allows equivalent soft tissue suppression with approximately 10% of the energy deposition of conventional magnetization transfer techniques.

Artifacts↗

Lung water measurement by nuclear magnetic resonance: correlation with morphometry.

Estimates of lung water content obtained from nuclear magnetic resonance (NMR) and morphometric and gravimetric measurements were compared in normal and experimentally injured rats. Average lung water density (rho H2O) was measured by an NMR technique in excised unperfused rat lungs (20 normal lungs and 12 lungs with oleic acid-induced edema) at 0 (full passive deflation) and 30 cmH2O lung inflation pressure and in vivo (4 normal rats and 8 rats with lung injury induced by oleic acid or rapid saline infusion). The rho H2O values were compared with morphometric measurements of lung tissue volume density (Vv) obtained from the same lungs fixed at corresponding liquid-instillation pressures. A close correlation was observed between rho H2O and Vv in normal and injured excised lungs [correlation coefficient (r) = 0.910, P < 0.01]. In vivo rho H2O was also closely correlated with Vv (r = 0.897, P < 0.01). The correlation coefficients between rho H2O and gravimetric lung water content (LWGr) were lower in the excised lung group (r = 0.663 and 0.692, respectively, for rho H2O at 0 and 30 cmH2O lung inflation pressure, P < 0.01) than in the in vivo study (r = 0.857, P < 0.01). Our results indicate that NMR techniques, which are noninvasive and nondestructive, provide reliable estimates of lung water density and that the influence of lung inflation on rho H2O is important (compared with the effect of lung water accumulation in lung injury) only in the presence of deliberately induced very large variations in the lung inflation level.

Animals↗

Alveolar air/tissue interface and nuclear magnetic resonance behavior of normal and edematous lungs.

The alveolar air/tissue interface markedly affects the NMR properties of lungs by causing an NMR signal loss as a result of internal (tissue-induced) magnetic field inhomogeneity. The signal loss can be measured as the difference in NMR signal intensity (difference signal delta) between a pair of images obtained using temporally symmetric and asymmetric spin-echo sequences. Previous data indicate that the difference signal measured at an asymmetry time of 6 ms (delta 6ms) is very low in degassed lungs and increases markedly with alveolar opening. Theoretically, the NMR behavior of edematous lungs is expected to differ from that of normal nondegassed lungs because alveolar flooding and collapse are equivalent to partial (regional) degassing. To test this prediction, we measured delta 6ms in normal and edematous (oleic acid-injured) excised unperfused rat lungs at 5, 10, 20, 30, and 0 (full passive deflation) cm H2O inflation pressure (PL). Lung volume changes were estimated from NMR lung water density (pH2O) measurements. In normal lungs, delta 6ms did not vary with PL. In edematous lungs delta 6ms was, as predicted, significantly lower than normal at 5 and 10 cm H2O PL but rose markedly (to about normal) as PL was further increased. Upon subsequent deflation from 30 to 0 cm H2O PL, delta 6ms did not vary significantly or decreased. On the basis of our theoretical models, the data could be interpreted as reflecting the loss of alveolar air/tissue interface as a result of alveolar flooding and the relative contributions of airspace recruitment and distension to the lung volume changes. Histologic and morphometric data obtained from the same lungs supported this interpretation.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Nuclear magnetic resonance Hahn spin-echo decay (T2) in live rats with endotoxin lung injury.

To determine the possibility of using nuclear magnetic resonance imaging to study experimentally induced lung injury, we measured in the lungs of spontaneously breathing living rats the time course of both the Hahn spin-echo decay (T2) and the proton density after endotoxin injury. In order to minimize artifacts arising from motions of the nearby chest wall and heart, we used a motion-insensitive technique (the interleaved line scan). A typical Hahn T2 measurement was obtained over a region of interest from a series of images each with a different echo time, which ranged from 16 to 110 ms. Lung water content was determined by integrating the proton density over the region of interest. The Hahn T2 and proton density were measured before and at 1, 3, 6, and 9 h after intravenous injection of endotoxin. The effects of the treatment administered before and after endotoxin injection were also evaluated. Endotoxin treatment caused lengthening of both fast (T2f) and slow (T2s) Hahn T2 components but had no significant effect on the proton density, consistent with the notion that endotoxin causes lung injury without significant lung water accumulation in rats. However, the methylprednisolone treatment prevented the lengthening of T2s but did not seem to have a significant effect on T2f. Our results suggest that NMR imaging can be used to detect and monitor experimental lung injury in intact living animals, even in the absence of variations of lung water content.

Animals↗

Comparison of in vivo and in vitro Hahn T2 measurements in rat lung.

We compared in vivo and in vitro Hahn echo T2 measurements in rat lungs in both imaging and nonimaging modes. All measurements could be characterized by multiexponential functions consisting of either two or three exponentials. Essentially the same values of the time constants were observed for spontaneously breathing rats and for excised lungs.

Animals↗

Reduction of slab boundary artifact with multiple overlapping thin slab acquisition in MR angiography of the cervical carotid artery.

Multiple overlapping thin slab acquisition (MOTSA) is a magnetic resonance (MR) angiography technique combining advantages of two- and three-dimensional time-of-flight techniques. The authors studied three image acquisition parameters (flip angle, TR, and the slab excitation fraction [SEF]) and a postprocessing algorithm, to evaluate their effect on MOTSA image quality, including contrast-to-noise ratio (C/N) and the severity of the slab boundary artifact. By increasing SEF from 0.75 to 1.10, the slab boundary artifact was reduced by 29%-56% (P < .0001). The boundary artifact can be reduced an additional 46% by postprocessing of the overlapping section data. In the healthy volunteers studied, C/N of the cervical carotid artery could be increased sixfold (P < .0001) by increasing the flip angle from 10 degrees to 50 degrees, without significant worsening of the boundary artifact due to top-of-slab saturation. The effect of TR on image quality was not statistically significant for the range studied (52-70 msec). We conclude that the slab boundary artifact seen with the MOTSA MR angiography technique can be reduced significantly by optimizing imaging acquisition parameters and using a postprocessing algorithm to combine overlapping section information.

Adult↗

Experimental and theoretical studies of vessel contrast-to-noise ratio in intracranial time-of-flight MR angiography.

CNR studies were performed for human intracranial vessels in 3D MRA data sets. The CNR dependency of different imaging parameters, such as flip angle, field of view, echo time, repetition time, and echo readout symmetry, was studied for vessels in the region of the circle of Willis. A theoretical model was developed for MR vascular imaging based on the Bloch equations and Fourier imaging theory. This model predicts the MR image intensity of vessels from basic subject parameters, such as the relaxation times of blood and stationary tissue, vessel dimension, and flow velocity, and the parameters of the imaging technique, such as flip angle, voxel volume, repetition time, and echo time. For most experiments, the model was found to fit the experimental results well. The validity of this model allows the optimization of imaging parameters to maximize vessel CNR in MR angiography.

Adult↗