PubMed Health⌕ Search

Biomedical subjects

K C Man

Publications and source records attributed to K C Man.

At least 37 records · Page 2Linked to original sources

Adenosine-induced atrial arrhythmia: a prospective analysis.

BACKGROUND: Adenosine is considered safe and effective for paroxysmal supraventricular tachycardia (PSVT), but anecdotal experience suggests that adenosine can precipitate atrial arrhythmias. OBJECTIVES: To determine the frequency and mechanisms of adenosine-induced atrial arrhythmias. SETTING: Clinical electrophysiology laboratory at a university medical center. DESIGN: Prospective observational study. PATIENTS: 200 consecutive patients with PSVT undergoing an electrophysiology procedure. INTERVENTION: During PSVT, 12 mg of adenosine was administered centrally through the femoral vein. MEASUREMENTS: Frequency of adenosine-induced atrial fibrillation. RESULTS: Paroxysmal supraventricular tachycardia terminated after adenosine administration in 198 patients (99% [95% CI, 96% to 100%]). Adenosine led to atrial fibrillation (n = 22) or atrial fibrillation and atrial flutter (n = 2) in 24 patients (12% [CI, 7.5% to 16.5%]). An atrial premature complex occurred in all 24 patients who developed atrial fibrillation, atrial flutter, or both and in 102 of the 176 patients (58%) who did not (P < 0.001). The mean (+/-SD) time from the preceding atrial complex to the atrial premature complex was shorter when an atrial arrhythmia occurred, and the mean ratio of this interval to the preceding atrial cycle length was also lower when atrial fibrillation developed (0.37 +/- 0.16 compared with 0.49 +/- 0.16; P = 0.002). CONCLUSIONS: The incidence of atrial fibrillation induced by 12 mg of adenosine administered through the femoral vein was 12%. Fibrillation seems to be associated with a "long-short" atrial sequence. If the mechanism of PSVT is unknown and the Wolff-Parkinson-White syndrome is possible, administration of adenosine should be limited to medical facilities that have emergency resuscitation equipment.

Adenosine↗

A prospective evaluation of catheter ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease and an implantable cardioverter-defibrillator.

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy is integral to current therapy for ventricular tachycardia. Patients with an ICD frequently require concomitant antiarrhythmic drug therapy. Despite this, some patients still receive frequent ICD therapies for ventricular tachycardia. Therefore, the purpose of this prospective study was to determine the utility of ablation of ventricular tachycardia in patients with an ICD who experience frequent ICD therapies. METHODS AND RESULTS: Twenty-one consecutive patients with frequent ICD therapies despite antiarrhythmic drug therapy were the subjects of this study. The mean age was 69+/-6 years, and 17 were men. The mean ejection fraction was 0.22+/-0.08, and all patients had coronary artery disease. During the 36+/-51 days (range, 4 days to 7 months) preceding the ablation procedures, the patients received 34+/-55 ICD therapies for the clinical ventricular tachycardia, or a mean of 25+/-88 ICD therapies per month. The patients underwent radiofrequency ablation of the presumed clinical ventricular tachycardia by inducing the tachycardia and mapping according to endocardial activation, continuous electrical activity, pace mapping, concealed entrainment, or mid-diastolic potentials. Ablation of the clinical arrhythmia was successful in 76% of patients during 1.4+/-0.6 (range, 1 to 3) ablation procedures and required 12.5+/-9.2 applications of energy. During 11.8+/-10.0 months of follow-up, the frequency of ICD therapies per month decreased from 60+/-80 before successful ablation to 0.1+/-0.3 ICD therapies per month after ablation (P=.01). A quality-of-life assessment demonstrated a significant improvement after successful (P=.02) but not unsuccessful ablation (P=.9). CONCLUSIONS: Radiofrequency ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease and an ICD has a reasonable success rate, significantly reduces ICD therapies, and appears to be associated with an improved quality of life.

Aged↗

Cost comparison of radiofrequency modification and ablation of the atrioventricular junction in patients with chronic atrial fibrillation.

BACKGROUND: Because it is not clear which technique is less expensive, the purpose of this study was to compare the cost of radiofrequency modification and ablation of the atrioventricular (AV) node in drug-refractory patients with atrial fibrillation and an uncontrolled ventricular rate. METHODS AND RESULTS: The initial nominal charges for a successful procedure were compared in 10 patients with chronic atrial fibrillation who underwent modification of the AV node ($13 109+/-2002) and 14 similar patients who underwent ablation and pacemaker implantation ($28 302+/-2023, P<.001). On the basis of the long-term follow-up of patients who underwent each procedure, it was assumed that 31% of patients selected for the modification procedure would require a permanent pacemaker for inadvertent AV block or because of AV nodal ablation after a failed modification procedure and that the recurrence rate after AV node ablation would be 2%. The annual charges during follow-up were predicted and adjusted for recurrences and the need for additional procedures. The adjusted total charges at 1 year of follow-up were significantly lower for the modification procedure ($19 389+/-2002) than for the ablation procedure ($28 485+/-2023, P<.001). After 10 years of follow-up, the cumulative, adjusted charges for modification were $20 016 (42%) less than for ablation. CONCLUSIONS: The initial charges generated by AV node modification are significantly lower than for AV node ablation in patients with chronic atrial fibrillation. Even when adjusted for higher failure and recurrence rates, the modification procedure retains a major cost advantage over ablation during long-term follow-up.

Aged↗

Effect of verapamil and procainamide on atrial fibrillation-induced electrical remodeling in humans.

BACKGROUND: Atrial fibrillation (AF) shortens the atrial effective refractory period (ERP) and predisposes to further episodes of AF. The purpose of this study was to determine the effect of verapamil and procainamide on these manifestations of AF-induced electrical remodeling. METHODS AND RESULTS: In adult patients without structural heart disease, the atrial ERP was measured before and after AF after pharmacological autonomic blockade and administration of verapamil (17 patients), procainamide (10 patients), or saline (20 patients). AF was then induced by rapid pacing. Immediately on AF conversion, the post-AF ERP was measured at alternating drive cycle lengths of 350 and 500 ms. In the saline group, the pre-AF and first post-AF ERPs at the 350-ms drive cycle length were 206+/-19 and 179+/-27 ms (P<.0001), respectively, and at the 500-ms drive cycle length, the values were 217+/-16 and 183+/-23 ms, respectively (P<.0001). There was a similar significant shortening of the first post-AF ERP in the procainamide group. In the verapamil group, however, there was no difference between the pre-AF and the first post-AF ERP at the 350-ms (226+/-15 versus 227+/-22 ms, P=.8) or 500-ms (230+/-17 versus 232+/-20 ms, P=.6) drive cycle length. During determinations of the post-AF ERP, 105 secondary episodes of AF were unintentionally induced in 12% of verapamil patients compared with 90% and 80% of saline and procainamide patients (P<.01 versus verapamil). CONCLUSIONS: Pretreatment with the calcium channel antagonist verapamil, but not the sodium channel antagonist procainamide, markedly attenuates acute, AF-induced changes in atrial electrophysiological properties. These data suggest that calcium loading during AF may be at least partially responsible for AF-induced electrical remodeling.

Adult↗

Probability of successful defibrillation at multiples of the defibrillation energy requirement in patients with an implantable defibrillator.

BACKGROUND: The probability of successful defibrillation has been determined in normal animals but not in patients undergoing defibrillator implantation. Therefore, the purpose of this prospective study was to determine the probability of successful defibrillation in humans on the basis of a step-down defibrillation energy requirement. METHODS AND RESULTS: Fifty-three consecutive patients underwent five separate inductions of ventricular fibrillation after the defibrillation energy requirement was determined with the use of small decrements and a step-down protocol (20, 15, 12, 10, 8, 6, 5, 4, 3, 2, 1, and 0.8 J). The first shock energy for defibrillation was either 1.0, 1.3, 1.5, 1.7, or 2.0 times the defibrillation energy requirement, and the likelihoods of successful defibrillation were 70+/-27%, 84+/-12%, 86+/-25%, 80+/-29%, and 88+/-32%, respectively (P=.03). The frequencies of uniformly successful defibrillation (5 of 5 defibrillation attempts) were 30%, 27%, 60%, 64%, and 73%, respectively (P=.01). Seven patients in whom the defibrillation energy requirement was <4 J had an overall rate of successful defibrillation of 54+/-20% compared with 86+/-20% in the remaining 47 patients (P=.002). The likelihood of successful defibrillation at twice the defibrillation energy requirement was 98% in the 46 patients with a defibrillation energy requirement of >4 J and 67% in the 7 patients with a defibrillation energy requirement of <4 J (P=.17). An absolute safety margin of 7 J was associated with a 96% probability of successful defibrillation. CONCLUSIONS: The probability of successful defibrillation is 70% at the defibrillation energy requirement. The probability plateaus at 88%, at twice the defibrillation energy requirement. A 96% probability of successful defibrillation is achieved at an absolute safety margin of 7 J, and a 98% success rate is achieved at energies that are twice the defibrillation energy requirement if the defibrillation energy requirement is >4 J. If the defibrillation energy requirement is <4 J, larger multiples of the defibrillation energy requirement are needed to achieve a high probability of successful defibrillation.

Arrhythmias, Cardiac↗

Failure of single- and multisite high-frequency atrial pacing to terminate atrial fibrillation.

This study determined the efficacy of single- and multisite atrial pacing for terminating episodes of atrial fibrillation induced in patients in the electrophysiology laboratory. One- to 5-second bursts of atrial pacing at a cycle length of 20 ms were not effective in terminating atrial fibrillation, when delivered either in the high right atrium or when delivered simultaneously at the high right atrium, midseptum, and coronary sinus.

Atrial Fibrillation↗

Comparison of effective and ineffective target sites that demonstrate concealed entrainment in patients with coronary artery disease undergoing radiofrequency ablation of ventricular tachycardia.

BACKGROUND: Concealed entrainment has been useful in guiding catheter ablation of monomorphic ventricular tachycardia in patients with coronary artery disease. However, not all sites with concealed entrainment result in successful ablation of the targeted ventricular tachycardia. The purpose of this prospective study was to identify factors at sites that demonstrate concealed entrainment that differentiate effective from ineffective target sites. METHODS AND RESULTS: In 14 consecutive patients with hemodynamically stable monomorphic ventricular tachycardia and coronary artery disease, radiofrequency ablation of 26 ventricular tachycardias was performed. Ablation was attempted at 46 sites that demonstrated concealed entrainment. Twenty-five of the targeted ventricular tachycardias (96%) were successfully ablated. The positive predictive value of concealed entrainment for successful ablation was 54%; it increased to 72% in the presence of a stimulus-QRS interval/ventricular tachycardia cycle length ratio of < or = 70%, to 82% in the presence of a match of the stimulus-QRS and electrogram-QRS interval, and to 89% in the presence of isolated mid diastolic potentials that could not be dissociated from ventricular tachycardia during entrainment. CONCLUSIONS: The positive predictive value of concealed entrainment for identification of successful ablation sites in patients with sustained ventricular tachycardia and coronary artery disease can be significantly enhanced by the presence of associated mapping criteria, particularly an isolated mid diastolic potential that cannot be dissociated from the tachycardia.

Adult↗

Relation between amiodarone and desethylamiodarone plasma concentrations and ventricular defibrillation energy requirements.

The main finding of this prospective, controlled study is that amiodarone and desethylamiodarone plasma concentrations < 1 mg/L are associated with a 23% increase in the acute defibrillation energy requirement and with a 31% increase in the requirement for a subcutaneous patch or array. The defibrillation energy requirement does not correlate with the plasma concentrations of amiodarone, desethylamiodarone, amiodarone plus desethylamiodarone, or with the duration or daily dosage of amiodarone therapy.

Aged↗

Long-term follow-up after radiofrequency modification of the atrioventricular node in patients with atrial fibrillation.

OBJECTIVES: The purpose of this study was to describe the long-term follow-up results in 62 patients with atrial fibrillation and an uncontrolled ventricular rate, who underwent radiofrequency modification of the atrioventricular (AV) node. BACKGROUND: Previous studies in small numbers of patients have suggested that radiofrequency modification may be effective in controlling the ventricular rate in patients with atrial fibrillation, but long-term follow-up data have been lacking. METHODS: The subjects of this study were 62 consecutive patients (mean age +/- SD 65 +/- 14 years; 43 with structural heart disease) who underwent an attempt at radiofrequency modification of the AV node because of symptomatic, drug-refractory atrial fibrillation with an uncontrolled ventricular rate. The atrial fibrillation was chronic in 46 patients and paroxysmal in 16. Radiofrequency energy was applied to the posteroseptal or mid-septal right atrium to lower the ventricular rate in atrial fibrillation to 120 to 130 beats/min during an infusion of 4 micrograms/min of isoproterenol. RESULTS: Short-term control of the ventricular rate was successfully achieved without the induction of pathologic AV block in 50 (81%) of 62 patients. Inadvertent high degree AV block occurred in 10 (16%) of 62 patients, with the AV block occurring at the time of the procedure in 6 patients and 36 to 72 h after the procedure in 4. During 19 +/- 8 months of follow-up (range 4 to 33), 5 (10%) of 50 patients had a symptomatic recurrence of an uncontrolled rate during atrial fibrillation. Overall, adequate rate control at rest and during exertion, without pathologic AV block, was achieved long term in 45 (73%) of 62 patients. Among 37 patients with a successful outcome, left ventricular ejection fraction increased from (mean +/- SD) 0.44 +/- 0.14 to 0.51 +/- 0.10 one year later (p < 0.001). Complications other than AV block included polymorphic ventricular tachycardia 10 to 24 h after the procedure in two patients who had a predisposing factor for ventricular tachycardia and sudden death 1 to 5 months after the procedure in two patients with idiopathic dilated cardiomyopathy, one of whom had a pacemaker for AV block. CONCLUSIONS: In approximately 70% of properly selected patients with atrial fibrillation and an uncontrolled ventricular rate, radiofrequency modification of the AV node results in excellent long-term control of the ventricular rate at rest and during exertion.

Aged↗

Response to pacing at sites of isolated diastolic potentials during ventricular tachycardia in patients with previous myocardial infarction.

OBJECTIVES: The goal of this study was to determine whether isolated diastolic potentials (IDPs) recorded during ventricular tachycardia (VT) are generated in zones of slow conduction and whether the arcs of block that bound these zones of slow conduction are functional or anatomic in nature. BACKGROUND: No previous studies have systematically investigated the response to pacing during VT and sinus rhythm at sites where IDPs are recorded. METHODS: The study included 11 patients with a previous infarction who underwent radiofrequency catheter ablation of 15 hemodynamically stable, sustained VTs and in whom an IDP that could not be dissociated from the VT was detected during mapping. RESULTS: Pacing during VT at the site where the IDP was recorded resulted in concealed entrainment in each of the 15 VTs. In 10 of the 15 VTs, an IDP was present during sinus rhythm at the same site at which a diastolic potential was recorded during VT. In nine VTs, the isolated potential occurred early in diastole; in these cases, the QRS configuration during pacing in the setting of sinus rhythm was different from that during VT. In six VTs, the isolated potential occurred later in diastole, and in these cases, the QRS configuration during pacing in the setting of sinus rhythm was the same as that during VT. CONCLUSIONS: Isolated diastolic potentials may often be generated in an area of slow conduction bounded by arcs of block that are anatomically determined and present during sinus rhythm.

Cardiac Pacing, Artificial↗

A randomized comparison of fixed power and temperature monitoring during slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

Temperature monitoring may be helpful for ablation of accessory pathways, however its role in ablation of atrioventricular nodal reentrant tachycardia (AVNRT) using the slow pathway approach is unclear. Therefore, the purpose of this study was to prospectively compare slow pathway ablation for AVNRT using fixed power or temperature monitoring. The study included 120 patients undergoing ablation for AVNRT. Patients were randomly assigned to receive either fixed power at 32 watts, or to temperature monitoring with a target temperature of 60 degrees C. The primary success rate was 72% in the fixed power group and 95% in the temperature monitoring group (p = 0.001). The ablation procedure duration (35 +/- 29 min vs 35 +/- 30 min; p = 0.9), fluoroscopic time (32 +/- 17 vs 35 +/- 19 min; p = 0.4), mean number of applications (10.2 +/- 8.1 vs 8.4 +/- 7.9; p = 0.2), and coagulum formation per application (0.2% vs 0.5%; p = 0.6) were statistically similar in the fixed power and temperature monitoring groups, respectively. The mean temperature (47.3 +/- 4.8 degrees C vs 48.6 +/- 3.8 degrees C; p < 0.01), and the temperature associated with junctional ectopy (48.2 +/- 3.8 degrees C vs 49.3 +/- 3.6 degrees C, p < 0.01) were less for the fixed power than the temperature monitoring group. In the temperature monitoring group, only 31% of applications achieved an electrode temperature of 60 degrees C. During follow up of 6.6 +/- 3.6 months there were two recurrences in the fixed power group and one in the temperature monitoring group (p = 1.0). In summary, power titration directed by temperature monitoring was associated with an improved primary procedural success rate. Applications of energy were associated with a temperature of approximately 50 degrees C with both techniques, suggesting that there is a low efficiency of heating in the posterior septum.

Adult↗

Rise in chronic defibrillation energy requirements necessitating implantable defibrillator lead system revision.

The chronic defibrillation energy requirement (DER) is believed to remain clinically stable in patients with defibrillators. Six patients (two with an epicardial and four with a nonthoracotomy system) were identified with a rise in their chronic DER, which eliminated a 10-J safety margin, thus necessitating a defibrillator lead system revision. The mean increase in DER was 14.7 +/- 4 J and was discovered at a mean of 16.0 +/- 18 months (range 2-41) following implantation. Management included placement of a defibrillator with a biphasic waveform, placement of an additional defibrillation electrode, or both. At 2 months following revision of the defibrillation system, a 10-J DER safety margin was present in each patient. In some patients, there is a progressive increase in the chronic DER with elimination of a 10-J safety margin necessitating revision of the defibrillation system. Routine reevaluation of the chronic DER, therefore, is necessary to identify these patients.

Aged↗

Accuracy of the unipolar electrogram for identification of the site of origin of ventricular activation.

INTRODUCTION: The purpose of this study was to determine the accuracy of the unipolar electrogram for identifying the earliest site of ventricular activation. The earliest site of ventricular activation may be identified with the unipolar electrogram by the absence of an R wave. However, the accuracy of this technique is unknown. METHODS AND RESULTS: A single ventricular premature complex was induced mechanically at the tip of an electrode catheter to simulate a ventricular premature depolarization site of origin. Unipolar electrograms were recorded from the right ventricular septum at the tip electrode and at 2, 5, 8, and 11 mm from the electrode tip in 20 patients. No R waves were detected at the ventricular premature depolarization site of origin. R waves were detected in 4 of 20 patients (20%) at 2 mm from the tip electrode and 7 of 20 patients (35%) at 5, 8, and 11 mm from the tip electrode. An R wave was not observed at distances < or = 11 mm from the site of tachycardia origin in 13 of 20 patients (65%). CONCLUSIONS: While an R wave in the unipolar electrogram can be seen as close as 2 mm from the site of impulse origin, the absence of an R wave as an indicator of the site of impulse origin in the right ventricle is highly inaccurate. Therefore, the absence of an R wave in the unipolar electrogram is unlikely to be an adequate guide for identification of an effective target site for ablation of right ventricular tachycardia.

Adult↗

Idiopathic left ventricular tachycardia with left and right bundle branch block configurations.

INTRODUCTION: Idiopathic left ventricular tachycardia typically has a right bundle branch block configuration. The purpose of this case report is to demonstrate that idiopathic ventricular tachycardia arising in or near the left posterior fascicle also may have a left bundle branch block configuration. METHODS AND RESULTS: A 27-year-old woman underwent an electrophysiologic procedure because of recurrent, verapamil-responsive, wide QRS complex tachycardia. Two types of ventricular tachycardia (cycle lengths 330 to 340 msec) were reproducibly inducible, one with a right bundle branch block configuration and left-axis deviation that had been documented clinically, and the other with a left bundle branch block configuration and axis of zero. A Purkinje potential recorded at the junction of the left ventricular mid-septum and inferior wall preceded the ventricular complex by 40 msec in both tachycardias. A single application of radiofrequency energy at this site successfully ablated both ventricular tachycardias. CONCLUSION: The findings of this case report demonstrate that idiopathic ventricular tachycardia arising in or near the left posterior fascicle may have a left bundle branch block configuration.

Adult↗

Effect of an irregular ventricular rhythm on cardiac output.

Impairment of cardiac function in atrial fibrillation has been attributed to loss of atrial contraction and to a rapid ventricular rate. The results of this study suggest that irregularity of the ventricular rhythm, independent of the ventricular rate, may also contribute to impairment of cardiac function during atrial fibrillation.

Atrial Fibrillation↗

Effect of coupling interval and pacing cycle length on morphology of paced ventricular complexes. Implications for pace mapping.

BACKGROUND: Ventricular pace mapping is performed by comparing the QRS morphology of ventricular paced complexes to that of a template arrhythmia, either a premature ventricular depolarization or a QRS complex during ventricular tachycardia. The objective of this study was to evaluate the effect of coupling interval and pacing cycle length on QRS morphology. METHODS AND RESULTS: The study population consisted of 20 patients (mean age, 38 +/- 16 years) undergoing a clinically indicated electrophysiology procedure. In the first 10 patients, the effect of coupling interval on the morphology of single paced ventricular complexes was evaluated visually and by signal processing techniques. Visually apparent differences in QRS morphology occurred in a mean of 4/12 electrocardiographic leads with a change in coupling interval of > or = 100 ms. In the next 10 patients, the QRS complex morphology during ventricular overdrive pacing at cycle lengths of 600 and 300 ms was found to differ significantly in a mean of 4/12 leads. The QRS morphology during overdrive pacing differed significantly from that of a single paced complex whenever the pacing cycle length differed from the coupling interval of the single paced complex by > 80 ms. CONCLUSIONS: The morphology of single paced QRS complexes may vary, depending on coupling interval, and the QRS morphology during overdrive pacing is affected by the pacing cycle length. During ventricular pace mapping, the coupling interval or cycle length of the template arrhythmia should be matched during pacing. If not, rate-dependent changes in QRS morphology that are independent of the pacing site may confound the results of pace mapping.

Adult↗

Effect of atrial fibrillation on atrial refractoriness in humans.

BACKGROUND: The acute effect of atrial fibrillation (AF) on the atrial effective refractory period (ERP) in humans is unknown. METHODS AND RESULTS: In 20 patients without structural heart disease, the atrial ERP was measured before and after pacing-induced AF at drive cycle lengths of 350 and 500 ms. Immediately after spontaneous AF conversion, the post-AF ERP was measured. The pre-AF ERPs at 350 and 500 ms were 206 +/- 23 and 216 +/- 17 ms, respectively. The time to spontaneous conversion of AF was 7.3 +/- 1.9 minutes. The first post-AF ERPs at drive cycle lengths of 350 and 500 ms were 175 +/- 30 ms (P < .0001 versus pre-AF) and 191 +/- 30 ms (P < .0001 versus pre-AF), respectively. The post-AF ERP returned to the pre-AF ERP value after a mean of 8.4 +/- 0.3 minutes. In 15 patients, during the determination of the post-AF ERP, secondary episodes of AF lasting 1 +/- 1.5 minutes were reinduced 6 +/- 3 times per patient. There was a significant inverse logarithmic relationship between the time to reinduction of AF and the duration of secondary episodes of AF (P < .0001, r = 5). CONCLUSIONS: In humans, several minutes of induced AF is sufficient to shorten the ERP for up to approximately 8 minutes. The temporal recovery of the ERP is reflected in progressively shorter episodes of reinduced AF. These data imply that AF transiently shortens the atrial wavelength and suggest a mechanism by which AF may perpetuate itself.

Adult↗