PubMed Health⌕ Search

Biomedical subjects

K C Seow

Publications and source records attributed to K C Seow.

5 recordsLinked to original sources

Automated detection and classification of sleep-disordered breathing from conventional polysomnography data.

Efficient automated detection of sleep-disordered breathing (SDB) from routine polysomnography (PSG) data is made difficult by the availability of only indirect measurements of breathing. The approach we used to overcome this limitation was to incorporate pulse oximetry into the definitions of apnea and hypopnea. In our algorithm, 1) we begin with the detection of desaturation as a fall in oxyhemoglobin saturation level of 2% or greater once a rate of descent greater than 0.1% per second (but less than 4% per second) has been achieved and then ask if an apnea or hypopnea was responsible; 2) an apnea is detected if there is a period of no breathing, as indicated by sum respiratory inductive plethysmography (RIP), lasting at least 10 seconds and coincident with the desaturation event; and 3) if there is breathing, a hypopnea is defined as a minimum of three breaths showing at least 20% reduction in sum RIP magnitude from the immediately preceding breath followed by a return to at least 90% of that "baseline" breath. Our evaluation of this algorithm using 10 PSG records containing 1,938 SDB events showed strong event-by-event agreement with manual scoring by an experienced polysomnographer. On the basis of manually verified computer desaturations, detection sensitivity and specificity percentages were, respectively, 73.6 and 90.8% for apneas and 84.1 and 86.1% for hypopneas. Overall, 93.1% of the manually detected events were detected by the algorithm. We have designed an efficient algorithm for detecting and classifying SDB events that emulates manual scoring with high accuracy.

Adult↗

Oxygen cost of exercise hyperpnea: implications for performance.

We addressed two questions concerned with the metabolic cost and performance of respiratory muscles in healthy young subjects during exercise: 1) does exercise hyperpnea ever attain a "critical useful level"? and 2) is the work of breathing (WV) at maximum O2 uptake (VO2max) fatiguing to the respiratory muscles? During progressive exercise to maximum, we measured tidal expiratory flow-volume and transpulmonary pressure- (Ptp) volume loops. At rest, subjects mimicked their maximum and moderate exercise Ptp-volume loops, and we measured the O2 cost of the hyperpnea (VO2RM) and the length of time subjects could maintain reproduction of their maximum exercise loop. At maximum exercise, the O2 cost of ventilation (VE) averaged 10 +/- 0.7% of the VO2max. In subjects who used most of their maximum reserve for expiratory flow and for inspiratory muscle pressure development during maximum exercise, the VO2RM required 13-15% of VO2max. The O2 cost of increasing VE from one work rate to the next rose from 8% of the increase in total body VO2 (VO2T) during moderate exercise to 39 +/- 10% in the transition from heavy to maximum exercise; but in only one case of extreme hyperventilation, combined with a plateauing of the VO2T, did the increase in VO2RM equal the increase in VO2T. All subjects were able to voluntarily mimic maximum exercise WV for 3-10 times longer than the duration of the maximum exercise. We conclude that the O2 cost of exercise hyperpnea is a significant fraction of the total VO2max but is not sufficient to cause a critical level of "useful" hyperpnea to be achieved in healthy subjects.(ABSTRACT TRUNCATED AT 250 WORDS)

Exercise↗

Flow limitation and regulation of functional residual capacity during exercise in a physically active aging population.

In 29 older (69 +/- 1 yr), physically active subjects (VO2max = 44 +/- 2 ml.kg-1.min-1), we determined the effect of an age-related decline in elastic lung recoil (i.e., Vmax50 = 65% of 30-yr-old adults) on the ventilatory response to progressive exercise. More specifically, we assessed if expiratory airflow limits were achieved and how this may modulate the regulation of end-expiratory lung volume (EELV). We found that with only mild to moderate (50 to 75% VO2max) exercise, the mean EELV was reduced 0.38 +/- 0.07 L, and that expiratory flow limitation was present over 25 +/- 4% of the VT. In 11 subjects during this intensity of exercise, EELV was within their closing capacity. As exercise intensity progressed, VT plateaued at 58 +/- 2% of the vital capacity, and increased expiratory air flow rates were achieved by significantly increasing the EELV back to near resting levels, thereby moving a portion of the expiratory tidal flow-volume envelope away from the constraints of the effort independent portion of the maximal flow-volume curve. During heavy exercise, end-inspiratory lung volume (EILV) approached 90% of TLC. To achieve greater expiratory flow with maximal exercise, EELV remained similar to the previous intensity, and a significantly greater portion of the tidal expiratory flow-volume envelope (greater than 40% of the VT) became flow-limited. Despite this significant expiratory limitation, a rise in EELV, and an EILV approaching TLC, TI/Ttot remained constant throughout exercise, and the ventilatory response for the metabolic demand (VA/VCO2) was appropriate.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Mechanical constraints on exercise hyperpnea in a fit aging population.

We studied 12 physically fit (VO2 max = 44 ml.kg-1.min-1) older subjects (age = 63 to 77 yr) who showed the usual age-related declines in lung function (i.e., reduced maximal expiratory flow rates, vital capacity and increased functional residual capacity, closing capacity, and residual volume). We measured the optimal transpulmonary pressures for maximal expiratory airflow and the capacity of the muscles of inspiration for developing pleural pressure (taking into account the effects of lung volume and flow rate). Within these mechanical constraints to ventilation we plotted tidal pleural pressure-volume loops for mild through maximal exercise according to a measured end-expiratory lung volume (EELV). We found EELV to decrease a mean of 0.26 +/- 0.09 L and maximal effective pleural pressures to be reached in nine subjects near EELV with only light to moderate exercise intensities, whereas peak inspiratory pressure was only 45% of the capacity for pressure generation. With progressive increases in exercise intensity, EELV increased, and pleural pressures encroached to a greater extent on the maximal effective pressures; however, they remained effective in the majority of subjects. During maximal exercise EELV was 0.13 +/- 0.10 L greater than resting values, 20% of the Vt reached maximal effective pressures, and 83% of the capacity for inspiratory pressure was achieved. Three subjects significantly surpassed their maximal effective expiratory pressures, and four subjects achieved 95 to 100% of the capacity for inspiratory pressure generation. These subjects also showed no further increase in ventilation while breathing 0.02 to 0.05 FICO2 at maximal exercise.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Adaptation of the inert gas FRC technique for use in heavy exercise.

We automated the inert gas rebreathe technique for measurement of end-expiratory lung volume (EELV) during heavy exercise. We also assessed the use of two gas tracers (He and N2) vs. a single gas tracer (He) for measurement of this lung volume and compared the two-tracer EELV to changes in the inspiratory capacity (defined with transpulmonary pressure) and shifts in the end-expiratory pressure from rest through heavy exercise. A computer program switched a pneumatic valve when flow crossed zero at end expiration and defined points in the He and N2 traces for calculation of EELV. An inherent delay of the rebreathing valve (50 ms) caused virtually no error at rest and during light exercise and an error of 74 +/- 9 ml in the EELV at peak inspiratory flow rates of 4 l/s. The measurement of EELV by the two gas tracers was closely correlated to the single-gas tracer measurement (r = 0.97) but was consistently higher (120 +/- 10 ml) than when He was used alone. This difference was accentuated with increased work rates (2-5% error in the EELV, rest to heavy exercise) and as rebreathe time increased (2-7% error in the EELV with rebreathe times of 5-20 s for all work loads combined). The double-gas tracer measurement of EELV agreed quite well with the thoracic gas volume at rest (P greater than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗