Modelling fields induced in humans by 50/60 Hz magnetic fields: reliability of the results and effects of model variations.

This paper presents a comparison of anatomically realistic human models and numerical codes in the dosimetry of power frequency magnetic fields. The groups at the University of Victoria and the National Radiological Protection Board have calculated the induced electric fields in both their 'UVic and 'NORMAN' models using independently developed codes. A detailed evaluation has been performed for a uniform magnetic field at 60 Hz. Comparisons of all dosimetric metrics computed in each particular model agree within 2% or less. Since in situ measurements cannot be performed in humans, and achievable accuracy of measurements in models and animals is not likely to be better than 10-15%, the comparisons presented should provide confidence limits on computational dosimetry. An evaluation of the effect of model size, shape and resolution has also been performed and further illuminated the reasons for differences in induced electric fields for various human body models.

Algorithms↗

Dosimetry in models of child and adult for low-frequency electric field.

Induced electric field and current density in a child's body exposed to a 60-Hz electric field are calculated and compared with those for an adult's body. Because of the different proportions of the child body relative to those of the adult body, differences in the induced electric field and current density values in various organs are observed. These results are interpreted in terms of international guideline limits, and hypotheses regarding plausible interactions.

Adult↗

Electric fields in the human body resulting from 60-Hz contact currents.

Contact currents occur when a person touches conductive surfaces at different potentials and completes a path for current flow through the body. Such currents provide an additional coupling mechanism to that, due to the direct field effect between the human body and low-frequency external fields. The scalar potential finite difference method, with minor modifications, is applied to assess current density and electric field within excitable tissue and bone marrow due to contact current. An anatomically correct adult model is used, as well as a proportionally downsized child model. Three pathways of contact current are modeled: hand to opposite hand and both feet, hand to hand only, and hand to both feet. Because of its larger size relative to the child, the adult model has lower electric field and current-density values in tissues/unit of contact current. For a contact current of 1 mA [the occupational reference level set by the International Commission on Non-ionizing Protection (ICNIRP)], the current density in brain does not exceed the basic restriction of 10 mA/m2. The restriction is exceeded slightly in the spine, and by a factor of more than 2 in the heart. For a contact current of 0.5 mA (ICNIRP general public reference level), the basic restriction of 2 mA/m2 is exceeded several-fold in the spine and heart. Several microamperes of contact current produces tens of mV/m within the child's lower arm bone marrow.

Adult↗

Pacemaker interference and low-frequency electric induction in humans by external fields and electrodes.

The possibility of interference by low-frequency external electric fields with cardiac pacemakers is a matter of practical concern. For pragmatic reasons, experimental investigations into such interference have used contact electrode current sources. However, the applicability to the external electric field problem remains unclear. The recent development of anatomically based electromagnetic models of the human body, together with progress in computational electromagnetics, enable the use of numerical modeling to quantify the relationship between external field and contact electrode excitation. This paper presents a comparison between the computed fields induced in a 3.6-mm-resolution conductivity model of the human body by an external electric field and by several electrode source configurations involving the feet and either the head or shoulders. The application to cardiac pacemaker interference is also indicated.

Biomedical Engineering↗

Numerical evaluation of 60 Hz magnetic induction in the human body in complex occupational environments.

Exposure to 60 Hz non-uniform magnetic fields is evaluated using realistic configurations of three-phase current-carrying conductors. Two specific scenarios are considered, one involving a seated worker performing cable maintenance in an underground vault with conductors carrying 500 A root-mean-square (rms) per phase, and the other involving a standing worker during inspection of a 700 MW generator with conductors carrying 20000 A (rms) per phase. Modelling is performed with a high-resolution (3.6 mm) voxel model of the human body using the scalar potential finite difference (SPFD) method. Very good correspondence is observed between various exposure-field measures, such as the maximum, average, rms and standard deviation values, and the associated induced field measures within the whole body and various organs. The exposure fields produced by the lower currents in the vault conductors result in correspondingly low current densities induced in human tissues. Average values are typically below 0.2 mA m(-2). On the other hand, the average exposure related to the inspection of the generator isophase buses is about 1.5 mT at a distance of 1.2 m from the conductors. This field induces organ average current densities in the range of 2-8 mA m(-2), and peak (maximum in voxel) values above 10 mA m(-2). A comparison with uniform field exposures indicates that induced fields in organs can be reasonably well estimated from the accurately computed exposure fields averaged over the organs and the organ dosimetric data for uniform magnetic fields. Furthermore, the non-uniform field exposures generally result in lower induced fields than those for the uniform fields of the same intensity.

Computer Simulation↗

Magnetic induction at 60 Hz in the human heart: a comparison between the in situ and isolated scenarios.

Numerical modelling is used to estimate the electric fields and currents induced in the human heart and associated major blood vessels by 60 Hz external magnetic fields. The modelling is accomplished using a scalar-potential finite-difference code applied to a 3.6-mm resolution voxel-based model of the whole human body. The main goal of the present work is a comparison between the induced field levels in the heart located in situ and in isolation. This information is of value in assessing any health risks due to such fields, given that some existing protection standards consider the heart as an isolated conducting body. It is shown that the field levels differ significantly between these two scenarios. Consequently, data from more realistic and detailed numerical studies are required for the development of reliable standards.

Computer Simulation↗

A comparison of 60 Hz uniform magnetic and electric induction in the human body.

High-resolution computations of induced fields are used to assess equivalent source levels for human exposure to uniform low-frequency electric and magnetic fields. These results pertain to 60 Hz foot-to-head electric excitation of the body in three positions with respect to a ground plane, and to magnetic excitation by three orthogonal source orientations. All computations are based on an anatomically derived human body model composed of 1736873 cubic voxels with 3.6 mm edges. The data for magnetic excitation are computed using a scalar potential finite difference (SPFD) method, while those for electric excitation are computed using a hybrid method based on the SPFD method coupled with a quasistatic finite difference time domain code. The data are analysed in two ways, using an induced current density threshold of 1 mA m-2. Firstly, the various field strengths required to produce a whole-body average current density magnitude equal to the threshold are derived for each configuration, and the associated current density levels in various organs and tissues are presented. It is found that the average current density magnitude values in at least one tissue group can be up to 3 (5) times greater than the whole-body average under electric (magnetic) excitation, and that the associated maximum values can be up to 46 (28) times greater than the whole-body average under electric (magnetic) excitation, for at least one source/body configuration. Secondly, the data are analysed from the opposite point of view, in which the source levels required to induce average or maximum induced current density magnitudes at the threshold level in specific tissue groups are determined. Evaluations such as the present one should prove useful in the development of protection standards, and are also expected to aid in the understanding of results from various animal and tissue culture studies.

Computer Simulation↗

Influence of human model resolution on computed currents induced in organs by 60-Hz magnetic fields.

The effects of human body model resolution on computed electric fields induced by 60 Hz uniform magnetic fields are investigated. A recently-developed scalar potential finite difference code for low-frequency electromagnetic computations is used to model induction in two anatomically realistic human body models. The first model consists of 204290 cubic voxels with 7.2-mm edges, while the second comprises 1639146 cubic voxels with 3.6-mm edges. Calculations on the lower-resolution model using, for example, the finite difference time domain or impedance methods, push the capabilities of workstations. The scalar method, in contrast, can handle the higher-resolution model using comparable resources. The results are given in terms of average and maximum electric field intensities and current density magnitudes in selected tissues and organs. Although the lower-resolution model provides generally acceptable results, there are important differences that make the added computational burden of the higher-resolution calculations worthwhile. In particular, the higher-resolution modelling generally predicts peak electric fields intensities and current density magnitudes that are slightly higher than those computed using the lower-resolution modelling. The differences can be quite large for small organs such as glands.

Data Interpretation, Statistical↗

Design and fabrication of well confined uniform magnetic field exposure systems.

Exposure systems that provide good magnetic field uniformity, minimum stray fields, and minimal heating, vibration, and hum, as well as capability for true sham exposure in which current flows in the coils, are needed to determine rigorously the biological effects of weak magnetic fields. Designs based on acrylic polymer coil support structures and twisted pair bifilary coil windings were employed to fabricate several different systems for the exposure of laboratory animals and cell cultures to magnetic fields. These systems exhibit excellent performance characteristics in terms of exposure field uniformity, stray field containment, and exposure field cancellation in the sham exposure mode. A custom-written computer program was used to determine the best arrangement for coils with regard to field uniformity in the exposure volume and stray field containment. For in vivo exposures, modules were made up of four Merritt four-coil sets, built into a single structure and positioned to form an octapole with fields directed in the horizontal plane. For in vitro applications, two different coil configurations were selected to produce the vertical fields required. A quadrupole system, comprising modules consisting of two Merritt four-coil sets arranged side by side to limit stray fields, was built as a prototype. In the second configuration, one Merritt four-coil set was positioned inside the other to form a concentric coil set. In both in vitro systems, exposure chambers were connected to remote commercial incubators in order to reduce ambient magnetic fields in the exposure volume.(ABSTRACT TRUNCATED AT 250 WORDS)

Acrylates↗