The stability of double jaw surgery: a comparison of rigid versus wire fixation.

The subjects of this study were 35 patients who underwent simultaneous surgery for superior repositioning of the maxilla and advancement of the mandible. They were studied cephalometrically for a comparison of the postsurgical stability of two commonly used fixation techniques: (1) rigid fixation with bone plates and (2) skeletal-wire fixation. One surgeon performed the operations on all 35 patients, and both groups were studied for an average of 15 months after surgery. Results showed that, although the maxilla remained relatively stable after surgery with both fixation techniques, rigid fixation tended to improve stability, primarily by eliminating relapse in excess of 2 mm. Mandibular stability was much greater with rigid fixation: the amount of relapse of the horizontal projection of B point with this method was 6%, while in the skeletal-wire sample it was 26%. Increased rotational stability between the proximal and distal segments of the mandible appeared to be a major factor in the improved overall stability of the rigid-fixation sample. The amount of mandibular relapse was found to be correlated to the amount of advancement in the wire-fixation sample, but not in the rigid-fixation sample.

Adult↗

Intraoral dental lights: test and evaluation.

Performance standards of dental task and ambient lighting systems were presented. Twelve brands of commercial dental lights were tested for compliance with ISO draft specifications. Technical results were presented and recommendations made to assist the dentist in selection of an optimal light system.

Dental Equipment↗

Potential retinal hazards of visible-light photopolymerization units.

We evaluated the potential for retinal damage, both thermal and photochemical, from commercially available visible-light photopolymerization units. The spectral radiance profiles of 11 visible-light photopolymerization units were measured by means of a spectroradiometer and the results weighted according to the American Conference of Governmental Industrial Hygienists (ACGIH) Blue Light Hazard Function and Thermal Hazard Function. The values were then integrated by means of the proposed ACGIH hazard formulae, so that we could determine the maximum permissible exposure (tMAX) duration for each light. This calculation assumed a worst-case condition of direct vision of the light source from a distance of 25 cm. The results indicate that there is no thermal hazard to the retina. The tMAX duration values for the photochemical (blue light) hazard to the retina ranged from 2.4 minutes per day (for the most hazardous unit) to 16.0 minutes per day (for the least hazardous). None of these hazard times is short enough to be of concern unless the individual operator elects to focus on the light source or the reflected output from these visible-light photopolymerization units for an extended period of time.

Dental Restoration, Permanent↗

Effect of renacidin on suture material.

Renacidin solution is used sometimes to irrigate renal units with retained calculi after definitive stone surgery. The effects of this solution on the integrity of suture material utilized to close kidneys have not been determined previously. In an attempt to define the best suture material to use when postoperative renacidin irrigation is contemplated, we studied the effects of this solution on a variety of sutures commonly used in genitourinary surgery.

Benzenesulfonates↗