Search for leptoquark pairs decaying into nunu+jets in pp collisions at square root[s] = 1.8 TeV.

We present the results of a search for leptoquark (LQ) pairs in (85.2+/-3.7) pb(-1) of pp* collider data collected by the D0 experiment at the Fermilab Tevatron. We observe no evidence for leptoquark production and set a limit on sigma(pp*-->LQLQ-->nunu+jets) as a function of the mass of the leptoquark (m(LQ)). Assuming the decay LQ-->nuq, we exclude scalar leptoquarks for m(LQ) < 98 GeV/c(2), and vector leptoquarks for m(LQ) < 200 GeV/c(2) and coupling which produces the minimum cross section, at a 95% confidence level.

Journal Article↗

Search for the scalar top quark in pp collisions at square root[s] = 1.8 TeV.

We have performed a search for scalar top quark (stop) pair production in the inclusive electron-muon-missing transverse energy final state, using a sample of pp events corresponding to 108.3 pb(-1) of data collected with the D0 detector at Fermilab. The search is done in the framework of the minimal supersymmetric standard model assuming that the sneutrino is the lightest supersymmetric particle. For the dominant decays of the lightest stop, t-->b chi+1 and t-->blnu, no evidence for signal is found. We derive cross-section limits as a function of stop ( t ), chargino ( chi+1), and sneutrino ( nu) masses.

Journal Article↗

Direct search for charged higgs bosons in decays of top quarks.

We present a search for charged Higgs bosons in decays of pair-produced top quarks in pp collisions at sqrt[s] = 1.8 TeV recorded by the D0 detector at the Fermilab Tevatron collider. With no evidence for signal, we exclude most regions of the ( M(H+/-),tan(beta)) parameter space where the decay t--> H(+)b has a branching fraction >0.36 and B(H+/--->tau(nu)(tau)) is large.

Journal Article↗

Evaluation of the Digene Hybrid Capture II Assay with the Rapid Capture System for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

Screening for chlamydial and gonococcal infection has been strongly recommended for all sexually active women under the age of 26. Advances in the ability to detect infection by nucleic acid detection techniques have improved access to screening methods in routine clinical practices. To meet the increasing demand for testing, a high-throughput system is desirable. We evaluated the performance of the Hybrid Capture 2 CT/GC (HC2) assay with the Digene Rapid Capture System (HC2-RCS). The results of HC2-RCS for endocervical samples from 330 women were compared to those of culture and the COBAS Amplicor PCR. For detection of chlamydial infection, HC2-RCS had a sensitivity and a specificity similar to those of PCR (P > 0.5) and an improved sensitivity compared to that of culture (P = 0.007). For identification of gonococcal infections, all assays performed similarly (P > 0.5). The performance of HC2-RCS was also compared to that of the manual HC2 format (HC2-M) with these samples and with 911 endocervical samples collected previously. The performance of HC2-RCS was equivalent to that of HC2-M; the overall concordance rates for the detection of chlamydia and gonorrhea were 99.7% (kappa = 0.97) and 99.8% (kappa = 0.97), respectively. When the HC2 assay was performed with a semiautomated system application designed for high throughput, it demonstrated high sensitivity and a high specificity for detection of both Chlamydia trachomatis and Neisseria gonorrhoeae.

Chlamydia Infections↗

Ratio of isolated photon cross sections in pp macro collisions at square root of s = 630 and 1800 GeV.

The inclusive cross section for production of isolated photons has been measured in pp macro collisions at square root of s = 630 GeV with the D0 detector at the Fermilab Tevatron Collider. The photons span a transverse energy (E(T)) range from 7-49 GeV and have pseudorapidity absolute value of eta < 2.5. This measurement is combined with the previous D0 result at square root of s = 1800 GeV to form a ratio of the cross sections. Comparison of next-to-leading-order QCD with the measured cross section at 630 GeV and the ratio of cross sections show satisfactory agreement in most of the E(T) range.

Journal Article↗

Search for new physics using QUAERO: a general interface to D0 event data.

We describe QUAERO, a method that (i) enables the automatic optimization of searches for physics beyond the standard model, and (ii) provides a mechanism for making high energy collider data generally available. We apply QUAERO to searches for standard model WW, ZZ, and t t macro production, to searches for these objects produced through a new heavy resonance, and to the first direct search for W'-->WZ. Through this interface, we make three data sets collected by the D0 experiment at square root of [s] = 1.8 TeV publicly available.

Journal Article↗

Search for heavy particles decaying into electron-positron pairs in pp collisions.

We present results of searches for technirho (rho(T)), techniomega (omega(T)), and Z' particles, using the decay channels rho(T),omega(T),Z'-->e(+)e(-). The search is based on 124.8 pb(-1) of data collected by the D0 detector at the Fermilab Tevatron during 1992-1996. In the absence of a signal, we set 95% C.L. upper limits on the cross sections for the processes pp-->rho(T),omega(T),Z'-->e(+)e(-) as a function of the mass of the decaying particle. For certain model parameters, we exclude the existence of degenerate rho(T) and omega(T) states with masses below about 200 GeV. We exclude a Z' with mass below 670 GeV, assuming that it has the same couplings to fermions as the Z boson.

Journal Article↗

Cancer-related fatigue: prevalence of proposed diagnostic criteria in a United States sample of cancer survivors.

PURPOSE: To evaluate the proposed cancer-related fatigue (CRF) diagnostic criteria in a sample of cancer survivors. More accurate prevalence estimates of CRF may result in improved diagnosis and management of one of the most common symptoms associated with cancer and its treatment. METHODS: Three hundred seventy-nine individuals who had been treated with chemotherapy, either alone or in combination with radiation therapy, were surveyed. Patients were asked background questions about their current condition, their medical history, and the frequency of fatigue during their chemotherapy. Additionally, patients who reported experiencing fatigue at least a few days each month during treatment were asked a series of questions about the impact of fatigue on their daily functioning. RESULTS: One hundred forty-one (37%) individuals reported at least 2 weeks of fatigue in the previous month. Of the respondents who had received their last treatment more than 5 years ago, 33% still reported at least a 2-week period of fatigue in the month before the interview. Evaluation of the proposed criteria revealed that 17% of respondents met at least two criteria for CRF. CONCLUSION: The prevalence of diagnosable CRF in the individuals in this sample, most of whom had completed treatment more than 1 year ago, was 17%-lower than expected based on previous reports that have used less-strict criteria. In a sizable number of people, CRF persists well beyond active treatment and should be a focus of intervention. Although they will require replication in other samples and clinical validation, these formal diagnostic criteria can be a step toward common language and a better understanding of the severity range and persistence of CRF.

Data Collection↗

Quasi-model-independent search for new high p(T) physics at D0.

We apply a quasi-model-independent strategy ("Sleuth") to search for new high p(T) physics in approximately 100 pb(-1) of pp collisions at square root of (s) = 1.8 TeV collected by the D0 experiment during 1992-1996 at the Fermilab Tevatron. We systematically analyze many exclusive final states and demonstrate sensitivity to a variety of models predicting new phenomena at the electroweak scale. No evidence of new high p(T) physics is observed.

Journal Article↗

Ratio of jet cross sections at square root of s = 630 GeV and 1800 GeV.

The D0 Collaboration has measured the inclusive jet cross section in barpp collisions at square root of s = 630 GeV. The results for pseudorapidities (eta)<0.5 are combined with our previous results at square root of s = 1800 GeV to form a ratio of cross sections with smaller uncertainties than either individual measurement. Next-to-leading-order QCD predictions show excellent agreement with the measurement at 630 GeV; agreement is also satisfactory for the ratio. Specifically, despite a 10% to 15% difference in the absolute magnitude, the dependence of the ratio on jet transverse momentum is very similar for data and theory.

Journal Article↗

Ratios of multijet Cross Sections in p p collisions at radical(s) = 1.8 TeV.

We report on a study of the ratio of inclusive three-jet to inclusive two-jet production cross sections as a function of total transverse energy in p&pmacr; collisions at a center-of-mass energy sqrt[s] = 1.8 TeV, using data collected with the D0 detector during the 1992-1993 run of the Fermilab Tevatron Collider. The measurements are used to deduce preferred renormalization scales in perturbative O(alpha(3)(s)) QCD calculations in modeling soft-jet emission.

Journal Article↗

Inclusive jet production in pp(macro) collisions.

We report a new measurement of the pseudorapidity (eta) and transverse-energy ( E(T)) dependence of the inclusive jet production cross section in pp(macro) collisions at square root of s = 1.8 TeV using 95 pb(-1) of data collected with the D0 detector at the Fermilab Tevatron. The differential cross section d(2)sigma/(dE(T)d eta) is presented up to eta = 3, significantly extending previous measurements. The results are in good overall agreement with next-to-leading order predictions from QCD and indicate a preference for certain parton distribution functions.

Journal Article↗

Search for large extra dimensions in dielectron and diphoton production.

We report a search for effects of large extra spatial dimensions in pp collisions at a center-of-mass energy of 1.8 TeV with the D0 detector, using events containing a pair of electrons or photons. The data are in good agreement with the expected background and do not exhibit evidence for large extra dimensions. We set the most restrictive lower limits to date, at the 95% C.L. on the effective Planck scale between 1.0 and 1.4 TeV for several formalisms and numbers of extra dimensions.

Journal Article↗

Condom effectiveness in reducing heterosexual HIV transmission.

BACKGROUND: The amount of protection that condoms provide for HIV and other sexually transmitted diseases is unknown. Cohort studies of sexually active HIV serodiscordant couples with follow-up of the seronegative partner, provide a situation in which a seronegative partner has known exposure to the disease and disease incidence can be estimated. When some individuals use condoms and some do not, namely some individuals use condoms 100% of the time and some never use (0%) condoms, condom effectiveness can be estimated by comparing the two incidence rates. Condom effectiveness is the proportionate reduction in disease due to the use of condoms. OBJECTIVES: The objective of this review is to estimate condom effectiveness in reducing heterosexual transmission of HIV. SEARCH STRATEGY: Studies were located using electronic databases (AIDSLINE, CINAHL, Embase, and MEDLINE) and handsearched reference lists. SELECTION CRITERIA: For inclusion, studies had to have: (1) data concerning sexually active HIV serodiscordant heterosexual couples, (2) a longitudinal study design, (3) HIV status determined by serology, and (4) contain condom usage information on a cohort of always (100%) or never (0%) condom users. DATA COLLECTION AND ANALYSIS: Studies identified through the above search strategy that met the inclusion criteria were reviewed for inclusion in the analysis. Sample sizes, number of seroconversions, and the person-years of disease-free exposure time were recorded for each cohort. If available, the direction of transmission in the cohort (male-to-female, female-to-male), date of study enrollment, source of infection in the index case, and the presence of STDs was recorded. Duplicate reports on the same cohort and studies with incomplete or nonsepecific information were excluded. HIV incidence was estimated from the cohorts of "always" users and for the cohorts of "never" users. Effectiveness was estimated from these two incidence estimates. MAIN RESULTS: Of the 4709 references that were initially identified, 14 were included in the final analysis. There were 13 cohorts of "always" users that yielded an homogeneous HIV incidence estimate of 1.14 [95% C.I.:.56, 2.04] per 100 person-years. There were 10 cohorts of "never" users that appeared to be heterogeneous. The studies with the longest follow-up time, consisting mainly of studies of partners of hemophiliac and transfusion patients, yielded an HIV incidence estimate of 5.75 [95% C.I.: 3.16, 9.66] per 100 person-years. Overall effectiveness, the proportionate reduction in HIV seroconversion with condom use, is approximately 80%. REVIEWER'S CONCLUSIONS: This review indicates that consistent use of condoms results in 80% reduction in HIV incidence. Consistent use is defined as using a condom for all acts of penetrative vaginal intercourse. Because the studies used in this review did not report on the "correctness" of use, namely whether condoms were used correctly and perfectly for each and every act of intercourse, effectiveness and not efficacy is estimated. Also, this estimate refers in general to the male condom and not specifically to the latex condom, since studies also tended not to specify the type of condom that was used. Thus, condom effectiveness is similar to, although lower than, that for contraception.

Cohort Studies↗

Assessment of mortality rates for congenital heart defects and surgeons' performance.

BACKGROUND: In the absence of reliable national data, we have collected results of all operations for congenital heart defects from five departments to assess mortality rates and compare them among surgeons and departments. METHODS: Data relating to all operations (2,718) carried out at the five centers during a period from April 1, 1997 through March 31, 1999. Clearly defined criteria were agreed for the classification of patients into various subgroups. RESULTS: The overall hospital mortality was 4.4% (95% confidence intervals 3.7%-5.3%). Mortality for open-operations was 12.6% in neonates, 5.1% in infants, and 3.5% in children. Mortality rates were 1.1% for coarctation, 0.4% ventricular septal defect, 4.1% atrioventricular septal defect, 2.9% Fallot, 0.9% switch, and 15.6% truncus arteriosus. Although individual surgeons' mortality rates ranged from 1.8% to 7.5%, none of the 12 surgeons' data were above 95% confidence intervals. For individual surgeons, the change in mortality rates between the 2 years ranged between -3.3% and +3.8%. CONCLUSIONS: With 2 years' data available, estimates of mortality rates are more precise as reflected by tighter confidence intervals. There were relatively small data sets for individual hospitals and surgeons, which made statistical evaluation difficult. For setting standards, data from more departments for a longer period will be required. Statistical methods alone cannot be used as a sole arbiter of what is considered acceptable performance.

Cause of Death↗

Design of clinical trials to evaluate the efficacy of platelet transfusion: the euroSPRITE trial for components treated with Helinx technology.

Methods of collection, preparation, and transfusion of platelet components have evolved markedly since the introduction of modern platelet transfusion therapy three decades ago. Despite these improvements, few randomized, prospective, controlled studies have been conducted to evaluate the effects of these innovations on the outcome of platelet transfusion--prevention and treatment of bleeding due to thrombocytopenia. The majority of studies have used posttransfusion platelet count increments (CIs) as the primary outcome variable rather than bleeding assessments. In general, these studies have only examined average values for platelet CIs or adjusted ratio measures such as corrected count increment (CCI). Because platelet transfusions are given repeatedly over variable periods of time, this type of analysis has not provided information about the effects of multiple platelet transfusions or about specific product or patient-related covariates that may impact the outcome. Longitudinal regression analysis of platelet CIs offers the potential to provide more information than simple average values of ratio measures. The euroSPRITE trial, a European, multicenter, phase III study undertaken to assess the clinical efficacy and safety of platelets prepared with Helinx technology (Cerus Corp, Concord, CA), used longitudinal regression analysis to characterize more fully the response to platelet transfusions with products prepared with this new pathogen inactivation technology. In contrast to previous studies, the euroSPRITE study examined peritransfusion hemostasis and global indices of hemostasis to correlate the effect of platelet CI with prevention and treatment of bleeding during a period of platelet transfusion support.

Blood Platelets↗

Long term modulation of the HPA axis by the hippocampus. Behavioral, biochemical and immunological endpoints in rats exposed to chronic mild stress.

Mature rats were given lesions of the hippocampus (HIPPO), subiculum (SUBIC) or fimbria-fornix (FIFO) and then received the mild chronic stressors of food deprivation and isolation housing for ten months prior to testing. Group differences in circadian activity were investigated along with locomotion elicited by amphetamine (AMP 1.0-2.0 mg/kg i.p.) alone, and following the corticosterone (CORT) synthesis inhibitor, metyrapone (MET 10.0-25.0 mg/kg i.p.). Basal levels of plasma CORT, (ng/ml), plasma glucose (GLUC, mmol/l), thymic and splenic wet weights were subsequently determined along with complete blood counts (CBC). In comparison to age matched, unoperated controls, selective SUBIC lesions altered the circadian periodicity of locomotion, while rats with FIFO lesions were spontaneously hyperactive. Both HIPPO and FIFO animals showed significantly higher levels of amphetamine-induced locomotion. In all groups metyrapone significantly enhanced locomotion elicited by amphetamine, probably due to a pharmacokinetic interaction between these drugs. In comparison to controls, animals in the HIPPO group showed significant reductions in plasma glucose levels, decreased thymic wet weights and reductions in lymphocyte numbers, indicating lesion-related immuno-suppression. These findings highlight a functional difference among the effects of these specific hippocampal lesions on neural regulation of the HPA axis, under conditions of chronic mild stress, suggesting that the modulatory influence of the hippocampus on the stress axis is dependent on the neuroanatomical location and total extent of cell loss within this structure. They further suggest that the heightened response to amphetamine occurs independently of any lesion-induced changes in modulation of the HPA axis.

Animals↗

Racial and ethnic differences in drug treatment entry of injection drug users in Massachusetts.

This article examines patterns of drug treatment entry among 28,000 adult injection drug users (IDUs), with special attention to racial and ethnic differences. The data analyzed originates from a statewide drug-treatment database covering four years. Through the use of logistic regression analysis, the study identified significant population differences between those who used detoxification only, those who used residential treatment and those who used methadone maintenance. Latino IDUs were approximately a third less likely than Caucasian IDUs to enter residential treatment and African American IDUs were half as likely as Caucasian IDUs to enter methadone maintenance treatment. This article discusses specific programmatic and research implications including the need to determine whether differential entry rates are due to access, client awareness, cultural, referral or other factors.

Adult↗