PubMed Health⌕ Search

Biomedical subjects

K Dreyer

Publications and source records attributed to K Dreyer.

At least 19 recordsLinked to original sources

Plasma cytokines do not reflect expression of pro- and anti-inflammatory cytokine mRNA at organ level after cardiopulmonary bypass in neonatal pigs.

BACKGROUND: Plasma concentrations of inflammatory markers are increased in response to the trauma of cardiac surgery and cardiopulmonary bypass (CPB). It is, however, unknown whether the plasma cytokine levels and cytokine mRNA expression at organ level reflect each other. METHODS: Twenty-six piglets (17-19 days) were allocated to the sham-group (sternotomy only, n = 13) or to the CPB-group (sternotomy, 120 min CPB procedure with 60-min aortic cross-clamp, n = 13). The pigs were observed for 0.5 h or 4 h post-CPB. Plasma levels of IL-1beta, IL-6, IL-8 and IL-10 and mRNA expression of TNF-alpha, IL-1beta, IL-6, IL-8, IL-10 and iNOS in organs were registered with concomitant changes in oxygenation index (OI) and expiratory nitric oxide (NO). RESULTS: In pigs killed 0.5 h post-CPB there was a significant increase in IL-10 mRNA in the lungs and kidneys compared with the sham-group. IL-1beta mRNA was detectable in the kidneys and lungs of the CPB-pigs, while IL-6 mRNA was up regulated only in lungs. In pigs killed 4 h post-CPB a significantly higher IL-6 mRNA was found in heart tissue and a lower IL-10 mRNA was found in lungs of CPB pigs compared with the sham-group. There was a concomitant significant increase in OI and increased plasma IL-8 and IL-10 concentrations in the CPB-pigs compared with the sham-pigs. CONCLUSION: The cytokine mRNA expression pattern was very different for the pigs killed already 0.5 h after the CPB procedure compared with the pigs killed 4 h post-CPB. The plasma cytokine levels poorly reflected mRNA expression of the pro- and anti-inflammatory cytokines.

Animals↗

Integrating digital educational content created and stored within disparate software environments: an extensible markup language (XML) solution in real-world use.

OBJECTIVE: To provide a standardized and scaleable mechanism for exchanging digital radiologic educational content between software systems that use disparate authoring, storage, and presentation technologies. MATERIALS/METHODS: Our institution uses two distinct software systems for creating educational content for radiology. Each system is used to create in-house educational content as well as commercial educational products. One system is an authoring and viewing application that facilitates the input and storage of hierarchical knowledge and associated imagery, and is capable of supporting a variety of entity relationships. This system is primarily used for the production and subsequent viewing of educational CD-ROMS. Another software system is primarily used for radiologic education on the world wide web. This system facilitates input and storage of interactive knowledge and associated imagery, delivering this content over the internet in a Socratic manner simulating in-person interaction with an expert. A subset of knowledge entities common to both systems was derived. An additional subset of knowledge entities that could be bidirectionally mapped via algorithmic transforms was also derived. An extensible markup language (XML) object model and associated lexicon were then created to represent these knowledge entities and their interactive behaviors. Forward-looking attention was exercised in the creation of the object model in order to facilitate straightforward future integration of other sources of educational content. XML generators and interpreters were written for both systems. RESULTS: Deriving the XML object model and lexicon was the most critical and time-consuming aspect of the project. The coding of the XML generators and interpreters required only a few hours for each environment. Subsequently, the transfer of hundreds of educational cases and thematic presentations between the systems can now be accomplished in a matter of minutes. The use of algorithmic transforms results in nearly 100% transfer of context as well as content, thus providing "presentation-ready" outcomes. CONCLUSION: The automation of knowledge exchange between dissimilar digital teaching environments magnifies the efforts of educators and enriches the learning experience for participants. XML is a powerful and useful mechanism for transfering educational content, as well as the context and interactive behaviors of such content, between disparate systems.

Computer Storage Devices↗

Integrating digital teaching-file systems with off-the-shelf presentation software to facilitate speaker-led conferences.

OBJECTIVE: Develop methods for automated transfer of images and associated text from a teaching-file repository into presentation material for speaker-led conferences. MATERIALS/METHODS: Our institution uses a Microsoft Windows (Microsoft Corp, Redmond, WA) software application to maintain a digital teaching-file database that can store and retrieve content in a case-centric fashion. Virtually any number of images can be stored with any given case. Cases and their associated images can be retrieved via a module that supports searches by American College of Radiology (ACR) code and by free-text Boolean queries on the history, findings, diagnosis, and discussion components of a case. In addition to the software system serving directly as an interactive teaching tool, the digital teaching file itself serves as an image repository and resource for attending radiologists who create their own presentations and lectures. To better support this use, software modules were developed for interprocess communication and automated creation of Powerpoint slides. These modules are fully integrated with the teaching-file software application. A single image or a set of selected images can be automatically made into individual slides with two mouse clicks. Images are automatically centered and optimally sized. A slide title is automatically rendered from the user's preference of the case history or diagnosis (stored with the case), or via the entry of freeform text. We describe the programming techniques that are used, as well as how several features of the operating system and Powerpoint itself can be integrated with a customized software application to facilitate this objective. RESULTS: The creation of presentation-ready Powerpoint slides is fully automated from within our teaching-file application, and the time required to create a presentation compared to the conventional method of manually seeking and inserting files from within Powerpoint itself, on a per-slide basis, is drastically reduced. The benefits are magnified by having all imagery stored within an organized and searchable database system so that desired images can be easily located. CONCLUSION: A digital teaching-file system can serve as a useful image repository for purposes ancillary to direct computerized instruction. Software that supports these uses, such as the automated creation of presentation material for speaker-led conferences, facilitates the radiologist's role as an educator.

Computer-Assisted Instruction↗

Beyond the electronic textbook model: software techniques to make on-line educational content dynamic.

OBJECTIVE: We describe a working software technology that enables educators to incorporate their expertise and teaching style into highly interactive and Socratic educational material for distribution on the world wide web. MATERIALS/METHODS: A graphically oriented interactive authoring system was developed to enable the computer novice to create and store within a database his or her domain expertise in the form of electronic knowledge. The authoring system supports and facilitates the input and integration of several types of content, including free-form, stylized text, miniature and full-sized images, audio, and interactive questions with immediate feedback. The system enables the choreography and sequencing of these entities for display within a web page as well as the sequencing of entire web pages within a case-based or thematic presentation. Images or segments of text can be hyperlinked with point-and-click to other entities such as adjunctive web pages, audio, or other images, cases, or electronic chapters. Miniature (thumbnail) images are automatically linked to their full-sized counterparts. The authoring system contains a graphically oriented word processor, an image editor, and capabilities to automatically invoke and use external image-editing software such as Photoshop. The system works in both local area network (LAN) and internet-centric environments. An internal metalanguage (invisible to the author but stored with the content) was invented to represent the choreographic directives that specify the interactive delivery of the content on the world wide web. A database schema was developed to objectify and store both this electronic knowledge and its associated choreographic metalanguage. A database engine was combined with page-rendering algorithms in order to retrieve content from the database and deliver it on the web in a Socratic style, assess the recipient's current fund of knowledge, and provide immediate feedback, thus stimulating in-person interaction with a human expert. RESULTS: This technology enables the educator to choreograph a stylized, interactive delivery of his or her message using multimedia components assembled in virtually any order, spanning any number of web pages for a given case or theme. An educator can thus exercise precise influence on specific learning objectives, embody his or her personal teaching style within the content, and ultimately enhance its educational impact. CONCLUSION: The described technology amplifies the efforts of the educator and provides a more dynamic and enriching learning environment for web-based education.

Computer-Assisted Instruction↗

Empowering radiologic education on the Internet: a new virtual website technology for hosting interactive educational content on the World Wide Web.

OBJECTIVE: We describe a virtual web site hosting technology that enables educators in radiology to emblazon and make available for delivery on the world wide web their own interactive educational content, free from dependencies on in-house resources and policies. MATERIALS/METHODS: This suite of technologies includes a graphically oriented software application, designed for the computer novice, to facilitate the input, storage, and management of domain expertise within a database system. The database stores this expertise as choreographed and interlinked multimedia entities including text, imagery, interactive questions, and audio. Case-based presentations or thematic lectures can be authored locally, previewed locally within a web browser, then uploaded at will as packaged knowledge objects to an educator's (or department's) personal web site housed within a virtual server architecture. This architecture can host an unlimited number of unique educational web sites for individuals or departments in need of such service. Each virtual site's content is stored within that site's protected back-end database connected to Internet Information Server (Microsoft Corp, Redmond WA) using a suite of Active Server Page (ASP) modules that incorporate Microsoft's Active Data Objects (ADO) technology. Each person's or department's electronic teaching material appears as an independent web site with different levels of access--controlled by a username-password strategy--for teachers and students. There is essentially no static hypertext markup language (HTML). Rather, all pages displayed for a given site are rendered dynamically from case-based or thematic content that is fetched from that virtual site's database. The dynamically rendered HTML is displayed within a web browser in a Socratic fashion that can assess the recipient's current fund of knowledge while providing instantaneous user-specific feedback. Each site is emblazoned with the logo and identification of the participating institution. Individuals with teacher-level access can use a web browser to upload new content as well as manage content already stored on their virtual site. Each virtual site stores, collates, and scores participants' responses to the interactive questions posed on line. CONCLUSION: This virtual web site strategy empowers the educator with an end-to-end solution for creating interactive educational content and hosting that content within the educator's personalized and protected educational site on the world wide web, thus providing a valuable outlet that can magnify the impact of his or her talents and contributions.

Computer-Assisted Instruction↗

Do picture archiving and communication systems improve report turnaround times?

Radiology departments are beginning to embrace new technologies to decrease operating budgets and improve services. One of these technologies is the picture archiving and communication system (PACS). PACS, through immediate availability of images to the radiologist, promises to decrease turnaround times of reports to the clinician. The purpose of this study was to determine if this technology actually decreases the time for referring clinicians to receive reports generated by the radiologist. The time to provide a preliminary report by a resident and time to finalize this report by a board-certified radiologist was retrospectively obtained for 6,022 abdominal and pelvic computed tomography (CT) scans over two 1-year periods from March 1, 1997 to March 1, 1998 and from March 1, 1998 to March 1, 1999. During the first year, interpretation was conducted using hard-copy film and during the second using PACS. In both 1-year periods, MedSpeak voice recognition software (IBM, White Plains, NY) was employed for dictation. The average time for a preliminary report for a abdominal and pelvic CT, dictated by a resident or fellow, to be available in alphanumeric form on the hospital information system using hard-copy film was 3.73 days. The installation of a PACS system decreased this turnaround time to 0.56 days, representing an 85.0% improvement. The time to availability of final reports, ie, signed by board-certified staff radiologists, was 5.49 days in the hard-copy interpretation subset and 5.97 days in the PACS subset. The addition of PACS into an academic gastrointestinal radiology division improves availability of alphanumeric preliminary reports of abdominal and pelvic CTs on the hospital information system (HIS), dictated by a resident or fellow, by 85.0%. There was no impact with a PACS on the time to final sign reports by a staff board certified radiologist as signing patterns remained relatively constant over the two interpretation formats.

Data Display↗

A 13-amino-acid Pit1-specific loop 4 sequence confers feline leukemia virus subgroup B receptor function upon Pit2.

Feline leukemia virus subgroup B (FeLV-B) and gibbon ape leukemia virus (GALV) utilize the human protein Pit1 but not the related protein, Pit2, as receptor. A stretch of 9 amino acids, named region A, was identified in the putative fourth extracellular loop of Pit1 (residues 550 through 558) as critical for FeLV-B and GALV receptor function. However, the presence of Pit1 region A did not confer receptor function for FeLV-B upon Pit2, while it did so for GALV. We have here shown that the presence of two Pit1-specific loop 4 residues (tyrosine 546 and valine 548) in addition to Pit1 region A is sufficient to make Pit2 an efficient FeLV-B receptor; that is, a stretch of 13 amino acids encompassing all loop 4 amino acid differences between Pit1 and Pit2 comprises a C-terminal determinant for FeLV-B receptor function. Thus, the same limited receptor region is sufficient to confer receptor function for both viruses upon Pit2.

3T3 Cells↗

Primary isolate neutralization by HIV type 1-infected patient sera in the era of highly active antiretroviral therapy.

Sera from highly selected HIV-1-positive patients are known to have the ability to neutralize a diverse array of primary isolates of HIV-1. The human osteosarcoma cell line that expresses CD4 and chemokine receptors (GHOST cells) was adapted to study HIV-1 neutralization in 37 HIV-1-infected individuals who were selected because of slow disease progression or nonprogression. Many of these individuals were receiving combination drug therapy. Molecularly cloned HIV-1 JR-FL and NL4-3 viruses were used as prototypes to define assay conditions. Sera were then tested at a 1:40 dilution against six additional primary isolates, three of which utilized CCR5 and three of which used both CCR5 and CXCR4. The assay was highly reproducible and independent of viral input titer, with a readout at 48 hr equivalent to that at later time points. As previously reported, neutralization sensitivity was entirely independent of coreceptor usage. Only a few sera from slow progressors were able to neutralize a broad array of primary isolates at a 1:40 dilution, and the best clinical predictor of broadly neutralizing antibody for primary isolates was the present use of antiretroviral agents. In further studies it was found that purified antibody accounted for the majority of the measured neutralization. However, experiments with exogenous addition of antiviral agents showed that the use of nucleosides also greatly contributed to the measured neutralization in some patients. Measurement of neutralization of HIV-1 primary isolates by sera from patients receiving antiretroviral therapy must be carried out with some caution.

Anti-HIV Agents↗

Enhancing availability of the electronic image record for patients and caregivers during follow-up care.

PURPOSE: To develop a personal computer (PC)-based software package that allows portability of the electronic imaging record. To create custom software that enhances the transfer of images in two fashions. Firstly, to an end user, whether physician or patient, provide a browser capable of viewing digital images on a conventional personal computer. Second, to provide the ability to transfer the archived Digital Imaging and Communications in Medicine (DICOM) images to other institutional picture archiving and communications systems (PACS) through a transfer engine. METHOD/MATERIALS: Radiologic studies are provided on a CD-ROM. This CD-ROM contains a copy of the browser to view images, a DICOM-based engine to transfer images to the receiving institutional PACS, and copies of all pertinent imaging studies for the particular patient. The host computer system in an Intel based Pentium 90 MHz PC with Microsoft Windows 95 software (Microsoft Inc, Seattle, WA). The system has 48 MB of random access memory, a 3.0 GB hard disk, and a Smart and Friendly CD-R 2006 CD-ROM recorder (Smart and Friendly Inc, Chatsworth, CA). RESULTS: Each CD-ROM disc can hold 640 MB of data. In our experience, this houses anywhere from, based on Table 1, 12 to 30 computed tomography (CT) examinations, 24 to 80 magnetic resonance (MR) examinations, 60 to 128 ultrasound examinations, 32 to 64 computed radiographic examinations, 80 digitized x-rays, or five digitized mammography examinations. We have been able to successfully transfer DICOM images from one DICOM-based PACS to another DICOM-based PACS. This is accomplished by inserting the created CD-ROM onto a CD drive attached to the receiving PACS and running the transfer engine application. CONCLUSIONS: Providing copies of radiologic studies performed to the patient is a necessity in every radiology department. Conventionally, film libraries have provided copies to the patient generating issues of cost of loss of film, as well as mailing costs. This software package saves costs and loss of studies, as well as improving patient care by enabling the patient to maintain an archive of their electronic imaging record.

CD-ROM↗

Efficiencies of four versions of the AMPLICOR HIV-1 MONITOR test for quantification of different subtypes of human immunodeficiency virus type 1.

Three versions of a commercial human immunodeficiency virus (HIV) type 1 (HIV-1) load test (the AMPLICOR HIV-1 MONITOR Test versions 1. 0, 1.0+, and 1.5; Roche Diagnostics, Branchburg, N.J.) were evaluated for their ability to detect and quantify HIV-1 RNA of different genetic subtypes. Plasma samples from 96 patients infected with various subtypes of HIV-1 (55 patients infected with subtype A, 9 with subtype B, 21 with subtype C, 2 with subtype D, 7 with subtype E, and 2 with subtype G) and cultured virus from 29 HIV-1 reference strains (3 of subtype A, 6 of subtype B, 5 of subtype C, 3 of subtype D, 8 of subtype E, 3 of subtype F, and 1 of subtype G) were tested. Detection of subtypes A and E was significantly improved with versions 1.0+ and 1.5 compared to that with version 1. 0, whereas detection of subtypes B, C, D, and G was equivalent with the three versions. Versions 1.0, 1.0+, and 1.5 detected 65, 98, and 100% of the subtype A-infected samples from patients, respectively, and 71, 100, and 100% of the subtype E-infected samples from patients, respectively. Version 1.5 yielded a significant increase in viral load for samples infected with subtypes A and E (greater than 1 log10 HIV RNA copies/ml). For samples infected with subtype B, C, and D and tested with version 1.5, only a slight increase in viral load was observed (<0.5 log10). We also evaluated a prototype automated version of the test that uses the same PCR primers as version 1.5. The results with the prototype automated test were highly correlated with those of the version 1.5 test for all subtypes, but were lower overall. The AMPLICOR HIV-1 MONITOR Test, version 1.5, yielded accurate measurement of the HIV load for all HIV-1 subtypes tested, which should allow the test to be used to assess disease prognosis and response to antiretroviral treatment in patients infected with a group M HIV-1 subtype.

Evaluation Studies as Topic↗

Use of PCR in detection of Mycobacterium avium complex (MAC) bacteremia: sensitivity of the assay and effect of treatment for MAC infection on concentrations of human immunodeficiency virus in plasma.

We evaluated the sensitivity and specificity of a PCR-based qualitative test for the rapid diagnosis of Mycobacterium avium-M. intracellulare complex (MAC) bacteremia in patients with AIDS disease. Eleven subjects with newly culture-proven MAC bacteremia had the following tests performed at biweekly intervals during the first 8 weeks of therapy: blood culture, Mycobacterium-specific PCR, and quantitative human immunodeficiency virus (HIV) viral-load testing. Mycobacterium genus-specific biotinylated primers were used to amplify a sequence of approximately 582 nucleotides within the 16S rRNA genes of M. avium and M. intracellulare. Detection of the amplified product was performed with an oligonucleotide probe-coated microwell plate combined with an avidin-horseradish peroxidase-tetramethylbenzidine conjugate-substrate system. While not as sensitive as BACTEC culture, PCR detected 17 of 18 specimens which grew >/=40 organisms/ml (94.4% sensitivity) and 9 of 16 specimens which grew </=40 organisms/ml (56.3% sensitivity). No clear change in HIV viremia occurred in response to successful treatment of patients' MAC bacteremia. Use of the PCR test allowed detection of MAC bacteremia in 1 day, with a sensitivity similar to those of quantitative blood culture techniques, and it may prove useful for rapid screening of suspected cases. HIV viremia was unaffected by 8 weeks of MAC therapy.

AIDS-Related Opportunistic Infections↗

Development of calibrated viral load standards for group M subtypes of human immunodeficiency virus type 1 and performance of an improved AMPLICOR HIV-1 MONITOR test with isolates of diverse subtypes.

Accurate determination of plasma human immunodeficiency virus type 1 (HIV-1) RNA levels is critical for the effective management of HIV-1 disease. The AMPLICOR HIV-1 MONITOR Test, a reverse transcription-PCR-based test for quantification of HIV-1 RNA in plasma, was developed when little sequence information on HIV-1 isolates from outside North America was available. It has since become apparent that many non-subtype B isolates, particularly subtypes A and E, are detected inefficiently by the test. We describe here the AMPLICOR HIV-1 MONITOR Test, version 1.5, an upgraded test developed to minimize subtype-related variation. We also developed a panel of HIV-1 standards containing 30 HIV-1 isolates of subtypes A through G. The virus particle concentration of each cultured viral stock was standardized by electron microscopic virus particle counting. We used this panel to determine the performance of the original AMPLICOR HIV-1 MONITOR Test and version 1.5 of the test with HIV-1 subtypes A through G. The original test underestimated the concentration of HIV-1 subtype A, E, F, and G RNA by 10-fold or more, whereas version of the 1.5 test yielded equivalent quantification of HIV-1 RNA regardless of the subtype. In light of the increasing intermixing of HIV-1 subtypes worldwide, standardization of PCR-based tests against well-characterized viral isolates representing the full range of HIV-1 diversity will be essential for the continued utility of these important clinical management tools.

Acquired Immunodeficiency Syndrome↗

Assessment of cattle owner's perceptions and expectations, and identification of constraints on production in a peri-urban, resource-poor environment.

This questionnaire survey was conducted amongst 200 farmers in the resource-poor, urban and per-urban environments of Botshabelo and Thaba Nchu towns in the Free State Province of South Africa. The questionnaire was divided into seven sections, namely demography, livestock, cattle, parasites, parasite control, livestock diseases and problems experienced. A total of 87.5% of the livestock owners were not employed (unemployed or pensioner). Cattle constituted more than 50% of the live-stock units owned in the area and farmers owned an average of 9.33 +/- 0.812 head of cattle. A total of 193 (96.5%) of the farmers indicated that milk was the most important product from their cattle. Only 26% of them slaughtered their own cattle for meat consumption. Eighty-eight percent of them indicated that external parasites on their livestock presented a problem, but only 72.9% of farmers implemented any tick control measures. Less than half (45.5%) of the farmers who attempted to control ticks used commercial acaricides. The remainder used various other methods, including the application of used engine oil and household detergents. Amongst the clinical diseases observed in their cattle, dry gallsickness was mentioned most often (20%). This figure, however, is believed to be inaccurate because dry gallsickness may be a clinical manifestation of some of the other diseases mentioned by the farmers, such as anaplasmosis, foreign body obstruction of the gastro-intestinal tract by plastic bags, pneumonia and mastitis. Animal husbandry problems experienced by the farmers included pollution (i.e. ingestion of plastic bags and string by their livestock), availability of water and theft.

Agriculture↗

Gastro-intestinal parasites of cattle in the communal grazing system of Botshabelo in the Free State.

Twelve Bonsmara tracer calves (aged 6-12 months) were used to monitor helminth infections in the communal farming system of Botshabelo in the Free State. One calve was slaughtered each month from December 1995 to November 1996 and processed for helminth recovery. All the calves harboured worms, but the numbers were always low. The order of prevalence of the major parasites was Trichostrongylus axei, Haemonchus placei, Cooperia punctata and Cooperia pectinata.

Animals↗

Inhibition of HIV type 1 infection with a RANTES-IgG3 fusion protein.

The natural ligands for the chemokine receptors CCR5 (RANTES, MIP-1alpha, and MIP-1beta) and CXCR4 (SDF-1) can act as potent inhibitors of infection by the human immunodeficiency virus type 1 (HIV-1) at the level of viral entry. Unlike antibody-mediated inhibition, chemokine-mediated inhibition is broadly effective. Different HIV-1 strains can utilize the same coreceptor(s) for viral entry and, therefore, can be blocked by the same chemokine(s). HIV-1 strains that are highly resistant to neutralization by V3-specific antibodies are sensitive to inhibition by chemokines. Therefore, the use of chemokine-derived molecules constitutes a potential therapeutic approach to prevent infection by HIV-1. We have generated a fusion protein between RANTES and human IgG3 (RANTES-IgG3). The effectiveness of RANTES-IgG3 inhibition of infection by HIV-1 was similar to that of rRANTES. Inhibition of HIV-1 by RANTES-IgG3 was specific for CCR5-dependent but not CXCR4-dependent HIV-1 isolates. Fusion of a chemokine to an IgG moiety offers two desirable properties with respect to the recombinant chemokine alone. First, IgG fusion proteins have extended half-lives in vivo. Second, molecules with IgG heavy chain moieties may be able to cross the placenta and potentially induce fetal protection.

Cells, Cultured↗

Enterprise-scale image distribution with a Web PACS.

The integration of images with existing and new health care information systems poses a number of challenges in a multi-facility network: image distribution to clinicians; making DICOM image headers consistent across information systems; and integration of teleradiology into PACS. A novel, Web-based enterprise PACS architecture introduced at Massachusetts General Hospital provides a solution. Four AMICAS Web/Intranet Image Servers were installed as the default DICOM destination of 10 digital modalities. A fifth AMICAS receives teleradiology studies via the Internet. Each AMICAS includes: a Java-based interface to the IDXrad radiology information system (RIS), a DICOM autorouter to tape-library archives and to the Agfa PACS, a wavelet image compressor/decompressor that preserves compatibility with DICOM workstations, a Web server to distribute images throughout the enterprise, and an extensible interface which permits links between other HIS and AMICAS. Using wavelet compression and Internet standards as its native formats, AMICAS creates a bridge to the DICOM networks of remote imaging centers via the Internet. This teleradiology capability is integrated into the DICOM network and the PACS thereby eliminating the need for special teleradiology workstations. AMICAS has been installed at MGH since March of 1997. During that time, it has been a reliable component of the evolving digital image distribution system. As a result, the recently renovated neurosurgical ICU will be filmless and use only AMICAS workstations for mission-critical patient care.

Computer Communication Networks↗

The efficacy of used engine oil against ticks on cattle.

The study was conducted in a peri-urban agricultural system at Botshabelo, a city in the south-eastern Free State. A questionnaire survey revealed that 88.5% of cattle farmers in the area experienced problems related to ticks and tick-borne diseases. Because of the cost of commercial acaricides the Botshabelo farmers use alternative, cheaper methods of tick control, including the application of used engine oil. The specific aim of the study was to determine whether used engine oil can effectively control ticks on cattle. From March to August 1996 the tick burdens of ten control animals and six animals treated by their owner with used engine oil were compared. The total tick burdens for the 6 month period differed significantly between the two experimental groups. The efficacy of the used engine oil on the treated group varied between 15.1% and 64.8% with a mean of 38.1%. Although commercial acaricides can be more cost-effective, the application of used engine oil can be useful to reduce tick numbers on cattle during periods of peak abundance. Another advantage in that the use of the oil will not influence existing endemic stability of Anaplasma marginale and Babesia bigemina infections because of the residual tick burdens after treatment.

Animals↗