PubMed Health⌕ Search

Biomedical subjects

K Ellinger

Publications and source records attributed to K Ellinger.

At least 19 recordsLinked to original sources

Cardiac troponin I and cardiac troponin T increases in pigs during ischemia-reperfusion damage.

In this study we addressed the question of whether the measurement of cardiac Troponin T (cTnT) and cardiac Troponin I (cTnI) is able to detect myocardial cell damage in an ischemia-reperfusion model in pigs. To answer the question 3 pigs were anaesthesized and a cardiac arrest was induced by electric fibrillation. After 5 minutes of global ischemia the cardiac arrest was reversed by electric defibrillation until normal perfusion was restored. We could clearly demonstrate an increase of cTnT and cTnI 30 minutes after reperfusion indicating myocardial injury during ischemia and subsequent reperfusion. The cTnT as well as the cTnI serum levels increased till 180 minutes after reperfusion. This ischemia-reperfusion injury is likely induced by oxygen radicals generated during hypoxia and subsequent reperfusion We conclude from our first results that troponin measurements with commercial available test kits may also reflect myocardial cell damage in pigs as it was recently demonstrated in rats. Further studies are needed for correlation of troponin serum levels and histopathological damage in this model especially if it is used to test beneficial or toxicological effects of radical neutralizing drugs.

Animals↗

Hemodynamic effects of hypertonic hydroxyethyl starch 6% solution and isotonic hydroxyethyl starch 6% solution after declamping during abdominal aortic aneurysm repair.

Fluid resuscitation with hypertonic hydroxyethyl starch solutions (HES) is effective in haemorrhagic shock due to the rapid mobilisation of fluids into the intravascular compartment. Declamping of the abdominal aorta with acute redistribution of blood into the vessels of the lower body half causes declamping-induced hypotension. Usually large amount of fluids or vasopressors are necessary to restore hemodynamic stability. Therefore, infusion of a hypertonic colloid solution may be an attractive option to achieve hemodynamic stability. This study was conducted to determine the amount of fluid of either hypertonic HES (HES 6%;7.2% NaCl) or isotonic HES (HES 6%;0.9% NaCl) needed to attain best wedge pressure (PCWP) cardiac index (CI) relation after declamping. Thirty-two high-risk patients undergoing elective abdominal aneurysm resection were enrolled in a prospective, randomised, double blinded study. The individual optimised PCWP/CI relation was determined after induction of anaesthesia. After declamping, both solutions were titrated in small boluses of 100 mL until the previously determined best wedge was reached. The amount of fluid after declamping was significantly reduced in the hypertonic HES- group 162 mL vs. 265 mL in the control group (P < 0.05). Resuscitation time was shortened, and cardiac index was slightly higher in the treatment group. The use of hypertonic HES-solution after aortic declamping led to a significant reduction of fluids necessary to attain optimised PCWP/CI relation. In this clinical trial with moderate blood loss in high-risk patients, hypertonic HES applied in a titrated fashion restored hemodynamic stability faster and without volume overload.

Aged↗

[Controlling in clinical management].

Managers of industrial enterprises strive continually to improve the efficiency of production, distribution and service for their customers in order to be able to compete on the market. In socially orientated non-profit-organisations this is not universe practice. Relating to section 17 Abs. 1 KHG and section 13 BPfIV of German social legislation hospital charges are refunded only, if the hospital is working efficiently and economically. Controlling is a tool to achieve these goals. Controlling coordinates the flow of information for planning and evaluation. Strategic and operative controlling are closely interrelated: Strategic controlling is directed towards new and promising activities, operative controlling supports decision--making--including future-oriented aspects-by providing and condensing information. Controlling is definitely not intended to dictate or "command" any action. Its object is to serve as an instrument or tool supporting result-oriented planning, regulating and evaluation.

Germany↗

[Evaluation of a rapid qualitative test for cardiac troponin T in clinical diagnosis of patients with acute coronary syndrome].

OBJECTIVE: To evaluate the practical performance and the diagnostic power of a rapid, qualitative assay for the detection of cardiac Troponin T (indicated cut-off level: 0.3 ng/ml) in EMS patients presenting with acute myocardial ischemia. PATIENTS: 145 consecutive patients with non-traumatic chest pain treated by the Mobile Intensive Care Unit team. During phase 1 (73 patients), blood drawn at the emergency site was used to perform a Troponin T rapid assay under defined conditions at the hospital. During phase 2 (72 patients), the rapid assay was already performed at the emergency site. RESULTS: In phase 1 all tests were performed correctly, whereas 5.6% of the test results had to be declared invalid in phase 2. 17 (11.7%) of the 145 patients showed a positive test result. Analytic sensitivity was 100%, specificity 96.3%. 37 of the 145 patients (median duration of symptoms: 150 minutes) showed a myocardial infarction (MI). Related to the diagnosis of MI diagnostic sensitivity, specificity, positive and negative predictive values were 35.1, 96.3, 76.5, and 81.3%. Mortality in patients with a positive rapid assay was 35.3%, compared to 6.3% in patients with a negative test result (p < 0.001). CONCLUSIONS: The rapid assay allows the detection of Troponin T in concentrations above the cut-off level. Meticulous observance of the manufacturer's rules is imperative. A single preclinical rapid assay does not allow to exclude a MI. However, the test enables EMS personnel to identify patients who are at increased risk of dying from an acute coronary syndrome in the immediate future.

Aged↗

[Optimized documentation entry in emergency care using pen computers--initial results].

PURPOSE: Recently, documentation systems based on portable personal computers have become available for application in prehospital emergency medicine. The aim of the present study was to compare a handwritten record system with a pen-computing assisted documentation system. METHODS: 52 consecutive jobs of the local mobile intensive care unit (MICU) were recorded both by means of a handwritten record and by use of a pen-computer-assisted documentation system (NAPROT, based on DIVI-documentation system version 2.5). The paramedic performing pen-computing was obliged to restrict data inputs to those moments during which emergency physician was able to fill in his record. NAPROT routinely checked the records derived from the pen-computer for completeness of data before print-out. RESULTS: Neither hardware nor software problems occurred. Compared to the handwritten records the electronic documentation system resulted in a significant increase in recorded data. The following parameters were recorded more frequently by means of the new method of documentation: Glasgow Coma Score (47 vs 36 patients), positioning manoeuvres (36 vs 19 patients), blood glucose level (25 vs 17 patients), and complications (13 vs. 4 events). CONCLUSION: Pen-computing assisted documentation resulted in superior quality of data recorded in emergency medical files. This increase in information may be ascribed to the integrated check for completeness of data. The described new documentation system, therefore, enhances the processing quality in prehospital emergency medicine. Further developments of the documentation system should concentrate on tools while reducing the workload of the emergency physician.

Ambulances↗

[Prehospital management of emergency patients after previous treatment by general practitioners--a prospective study].

INTRODUCTION: In Germany emergency patients are currently treated both by certified emergency physicians as well as by family doctors and general practitioners. METHODS: 1.) We evaluated the cooperation between the regional rescue service centres of the general practitioners' acute response service and the EMS system in Baden-Württemberg, a German "Land" (province), with about 10 million inhabitants. 2.) We analysed the management of patients who had been initially treated by the general practitioners' acute response service or by family doctors and had then to be further stabilised by the emergency physicians of our mobile intensive care unit (MICU). RESULTS: 1.) Joint rescue service centres of the two organisations exist in only 12 of a total of 37 areas. Although lacking adequate emergency equipment, practitioners often treat vitally compromised patients without the assistance of the EMS system. 2.) 97 out of 105 jobs were further analysed (acute response service: n = 45; family doctors: n = 52). Suspected myocardial infarction (n = 32) and acute heart failure (n = 15) were the most common emergencies. Emergency management before the emergency physician arrived often did not meet common standards (lack of ECG monitoring, oxygen treatment, venous access, pain relief). Until the emergency physician arrived 40% of the patients had been left alone by their doctor. Moreover, medical documentation had to be classified as insufficient in 70%. CONCLUSIONS: Prehospital treatment of medical emergencies is impeded by the lack of cooperation between the involved organisations. Family doctors and general practitioners should not treat emergencies without the help of the local MICU. Solutions of these problems are presented.

Documentation↗

[New airbag-associated injuries in traffic accidents].

Experimental studies have shown that in traffic accidents with frontal impact the new airbag system can significantly reduce the incidence of severe injuries and fatal outcome. The question of whether the airbag itself induces specific patterns of injury needs further investigation. Two cases of traffic accidents with airbag protection are presented here. The first case report clearly shows the life-saving and injury-reducing effect of the airbag system in a traffic accident with frontal impact at 100 km/h. In the second case only minor injuries of the face were diagnosed initially. Hemodynamic instability occurred after 3 h of hospitalization due to rupture of the azygos vein. Analysis of the presented cases shows that, besides the well-known benefits, there are certain injury patterns that seem to be related to the use of airbags. These have not been described before. It is concluded that patients who were involved in traffic accidents with airbag deployment have to be hospitalized and followed up carefully over time, even though they are initially stable, as potentially fatal sequelae of deceleration trauma can occur later. In our opinion it is not possible to estimate the severity of airbag-associated injuries with conventional methods.

Accidents, Traffic↗

Active compression-decompression cardiopulmonary resuscitation--instructor and student manual for teaching and training. Part I: The workshop.

In an attempt to standardize the teaching and training of active compression-decompression cardiopulmonary resuscitation (ACD-CPR), a group of leading emergency physicians, cardiologists, anesthesiologists, paramedics and nurses with practical, theoretical, educational, and scientific experience in the subject met in June 1995. The group was called The International Working Group of Teaching and Training Active Compression-Decompression CPR. The group was 'born' as a result of the first International Conference of Active Compression-Decompression CPR held in Copenhagen in March 1995. The following paper describes the background, development and text of and ACD-CPR course manual for both students and instructors.

Cardiopulmonary Resuscitation↗

Active compression-decompression cardiopulmonary resuscitation does not improve survival in patients with prehospital cardiac arrest in a physician-manned emergency medical system.

OBJECT: To examine the efficacy of a new method of cardiac resuscitation, active compression-decompression cardiopulmonary resuscitation (ACD CPR), in prehospital cardiac arrest. DESIGN: Prospective, randomized, controlled trial. SETTING: Physician-manned Mobile Intensive Care Unit (MICU) of a university hospital, serving a population of 200,000. PARTICIPANTS: Adult patients with prehospital nontraumatic cardiac arrest treated by the MICU. INTERVENTIONS: Patients were randomized to standard chest compression according to American Heart Association (AHA) recommendations (group 1, 30 patients) or to the new technique (group 2, 26 patients). ACD was performed by use of a hand-held suction device. In both groups, advanced life support was performed as recommended by the AHA. MEASUREMENTS AND MAIN RESULTS: Rate of patients regaining a spontaneous circulation (ROSC), hospital discharge rate, and mean carbon dioxide content during resuscitation were recorded. ROSC rates in groups 1 and 2 were 40% and 38.5%, respectively. Four patients (13.3%) in group 1 and three patients (11.5%) in group 2 were discharged (group 1 v group 2: n.s.). Anatomic conditions precluded the application of ACD CPR in 5 patients. The new technique was found to impose greater physical efforts than STD CPR. Capnography was performed in 23 patients (mean value: STD CPR: 11.9 +/- 4.7 mmHg, ACD CPR: 13.7 +/- 4.9 mmHg [n.s.]). CONCLUSIONS: ACD CPR did not improve, outcome and practical performance was complicated. Therefore, this technique should not be performed routinely, or without strict supervision in prehospital cardiac arrest.

Adult↗

[Preclinical control of intubation and artificial respiration. Animal experiment and literature review].

Oesophageal malposition of an endotracheal tube is among the leading causes of anaesthesia incidents. While clinical manoeuvres for detection of tube malposition are unreliable, monitoring (i.e. capnography) can prevent such incidents. The problem is particularly important in prehospital care, where capnography is not (yet) widely available. We tested three devices used for differentiating oesophageal from endotracheal intubation: 1. Non-CO2-dependent Oesophageal Detector Device (ODD) as described by Pollard and Wee, 2. Semi-quantitative chemical disposable capnometer EasyCAP (Nellcor), 3. Non-quantitative infrared miniaturised capnometer MiniCAP (MSA). METHODS. 50 anaesthetised minipigs were intubated with a Magill tube. An identical additional tube was placed in the oesophagus. The cuffs of both tubes were inflated. Unexperienced personnel (students, laboratory technicians) were asked to determine the position of one of the tubes by using one of the devices according to the randomisation plan. The decision had to be taken within 30 s. Using the ODD, the proband first injected 100 ml air into the lung (or stomach) and then tried to aspirate the same volume. EasyCAP and MiniCAP were used according to manuals. RESULTS. Each device was used 25 times with a tracheal tube and 25 times with an oesophageal tube. All tube position identifications were correct. When ventilating the oesophagus/stomach for capnometric control, regurgitation into the tube occurred six times (five times with the EasyCAP and once with the MiniCAP). In these cases, the decision was based on this occurrence and not on the display of the device. While using the ODD no regurgitation occurred. CONCLUSION. These devices are useful for preclinical practice. According to the literature and our experience, the ODD is superior for the initial control of tube position, especially in cardiac arrest. Capnometry is needed, however, for continuous control of ventilation.

Anesthesiology↗

Optimal preoperative titrated dosage of hypertonic-hyperoncotic solutions in cardiac risk patients.

Hypertonic-iso/hyperoncotic solutions have been the subject of numerous studies, mostly used in a fixed dosage (4 mL/kg bw or 250 mL). Nearly no study exists to prove whether this is the appropriate dosage especially in cardiac risk patients with accompanying diseases. We have compared preoperative volume loading with either 10% hydroxyethyl-starch/7.5% NaCl (HHT-HES) or 10% hydroxyethyl-starch/.9% NaCl (HES) in 50 mL bolus infusions. Volume loading was done with either HES or HHT-HES in 2 x 20 patients before aortic aneurysmectomy. The endpoint of stepwise infusion represented the highest cardiac index (CI) at the lowest possible wedge pressure (PCWP) (turning point of each individual Frank Starling relation). 167.5 mL (+/- 45.5 mL = 2.41 mL/kg bw) of HHT-HES and 440 mL (+/- 26.15 mL = 6.33 mL/kg bw) of HES were necessary. We observed a significant higher increase of the CI in the HHT-HES group. Significant increases of PCWP, pulmonary artery pressure, and central venous pressure occurred within the groups without any significant differences between the groups (p < .05). Results of the study showed: 1) The commonly used fixed dosage of 4 mL/kg bw of HHT-HES is too high in cardiac risk patients with slight hypovolemia. 2) HHT-HES should be given in an individual titration. 3) In the HHT-HES group we observed a positive inotropic effect (higher CI). 4) With the individual titration of HHT-HES no negative side effects occurred (especially no hypotension).

Aged↗

Effects of hypertonic-hyperoncotic infusion on the human atrial natriuretic factor in a standardized clinical trial.

Hypertonic-hyperoncotic solutions (HHT) are presently being utilized to resuscitate patients in shock. However, so far, the effects of HHT on human atrial natriuretic factor (hANF) have not yet been investigated in a clinical trial. The effects of HHT on hANF were studied in a standardized preoperative and clinical setting in patients undergoing aneurysmectomy. Twenty-three conscious patients were included in two groups: 11 HHT and 12 HES (HHT: 7.5% NaCl/10% HES 200; HES: .9% NaCl/10% HES 200). Stepwise infusion of 50 mL was titrated preoperatively according to individual Frank-Starling relationships. Central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) were determined before, during and after volume application. hANF, cGMP were also measured before and 1, 10, 30, 60, and 120 min after administration. The volumes necessary to produce the same volume status were: 213.6 +/- 63.6 mL of HHT, 409.9 +/- 136.2 mL of HES (p < .001). The sodium load was 273.9 +/- 81.5 mmol of [HHT], 63.1 +/- 21.0 mmol of [HES] (p < .001).(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

[Randomized use of an active compression-decompression technique within the scope of preclinical resuscitation].

INTRODUCTION: Despite its worldwide propagation, external chest compression is of limited efficacy. Recently a new method of cardiac resuscitation, active compression-decompression (ACD), was presented. In animals and a small series of patients resuscitated within the hospital ACD proved to augment blood flow during cardiac resuscitation as a result of greater intrathoracic pressure gradients. AIM OF THE STUDY: We investigated whether ACD does provide superior survival in patients suffering from out-of-hospital cardiac arrest. METHODS: Doctors and paramedics of the mobile intensive care unit at Mannheim University Hospital were trained in the new method. 56 patients were randomly assigned to either standard chest compression according to recommendations of the American Heart Association, AHA (Group I, 30 patients) or to ACD (Group II, 26 patients). ACD was performed by use of a hand-held suction device (CardioPump, Ambu Int.). Compression (30-50 kp) and decompression (10-15 kp) were alternately applied to the patients' chest with a frequency of 80/min. Duration of compression was 50% of the cycle. In both groups advanced life support was performed according to AHA standards. RESULTS: In Group I, 40% of the patients could be resuscitated; and 13.3% were discharged from hospital. In Group II, 38.5% of the patients regained spontaneous circulation, and 11.5% of the patients were discharged. (Group I vs. Group II: n.s.). One patient in each group survived with a severe neurological deficit. ACD caused greater physical efforts than standard chest compression. Furthermore ACD was difficult to perform in patients with ventricular fibrillation once electrode gel had been used. ACD was not feasible in five patients because of large breast (four women) and kyphoscoliosis (one patient). The rate of serious complications was lower in Group II. CONCLUSIONS: Methods to verify the efficacy of ACD in dummy training should be developed. Paramedics performing ACD should relieve each other every 5 minutes. In patients resuscitated by ACD self-adhesive defibrillation paddles instead of electrode gel should be used. Modifications in the design of the CardioPump are desirable to enhance the efficacy of ACD. With regard to future multicentre trials all paramedics should be skilled in the new technique to reach more patients in a shorter period of time.

Adult↗

The glycoprotein B homologue of human herpesvirus 6.

The gene for the homologue of herpesvirus glycoprotein B (gB) has been identified in the genome of human herpesvirus 6 (HHV-6), strain U1102, and the nucleotide sequence was determined. The open reading frame encodes a protein of 830 amino acids (93.2K) with the characteristics of a transmembrane glycoprotein and close similarity to the gp58/116 complex of human cytomegalovirus (HCMV). Monoclonal antibodies 2D10 and 2B9 have been shown previously to react with an HHV-6 glycoprotein of apparent M(r) 112K, and its proteolytic cleavage products of M(r) 64K and 58K. We show that both monoclonal antibodies detect prokaryotically expressed carboxy-terminal fragments of the HHV-6 gB homologue. This indicates that the HHV-6 gB homologue is probably processed by proteolytic cleavage similar to its equivalents in HCMV and various other herpesviruses.

Amino Acid Sequence↗

Gene for the major antigenic structural protein (p100) of human herpesvirus 6.

A human herpesvirus 6 (HHV-6) structural protein of 100 kDa (p100) is the polypeptide most frequently and intensively reactive in immunoblotting analyses with human sera on HHV-6-infected cells or partially purified virions. The gene for p100 was identified by screening a bacteriophage lambda library with monospecific rabbit antisera. The gene codes for a polypeptide of 870 amino acids with a calculated molecular size of 97 kDa. Its amino-terminal third is weakly homologous to the immunogenic basic matrix phosphoprotein pp150 of human cytomegalovirus. Five fragments representing more than 93% of HHV-6 p100 were prokaryotically expressed. The antigenic epitopes of p100 were preliminary mapped by immunoblotting with human sera. They are located within the carboxy-terminal part which is neither homologous nor cross-reactive to pp150 of human cytomegalovirus. Availability of the gene for the immunodominant structural protein should provide tools for studies of pathogenesis by HHV-6.

Amino Acid Sequence↗