Use of molecularly imprinted solid-phase extraction for the selective clean-up of clenbuterol from calf urine.

A feasibility study was performed in order to study the possibilities in using molecularly imprinted polymers (MIPs) as sorbent material in solid-phase extraction (MISPE) for clean-up of clenbuterol from urine. A binding study of clenbuterol in several solvents was performed on a clenbuterol imprinted polymer as well as on a blank polymer. These binding experiments were used to find suitable loading, washing and elution solvents for the MISPE procedure. Extraction of clenbuterol from calf urine was performed by directly loading a 10-ml urine sample onto the MIP column. Thereafter the column was washed with 10 ml of acetonitrile containing 1% acetic acid, and finally clenbuterol was eluted with 6 ml of methanol containing 10% acetic acid. A recovery of 65% was obtained. This recovery could be increased up to 75% if a sample volume of 1 ml was used or up to 100% if urine was freeze-dried and the residue was dissolved in acetonitrile and spiked with clenbuterol prior to analysis. Chromatograms of the wash and eluate solutions show an efficient clean-up, which supports the potential of MISPE for clean-up of trace amounts of clenbuterol from calf urine.

Adrenergic beta-Agonists↗

Intra- and interinstrument reproducibility of migration parameters in capillary electrophoresis for substance identification in systematic toxicological analysis.

The intra- and interinstrument reproducibilities of four capillary electrophoresis instruments were studied for identification purposes in systematic toxicological analysis (STA). A test set of 20 acidic test compounds and 5 reference compounds were analyzed for five days on each instrument using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). The buffers consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate and 50 mM sodium dodecyl sulfate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries at an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA. To deal with the poor reproducibility of the migration time, we recently introduced the corrected effective mobility. In this study, we investigated the intra- and interinstrument reproducibility of the migration time, the effective mobility, and the corrected effective mobility. Large differences in intra-instrument reproducibility were found when the migration time was used. The calculation of the effective mobility and the corrected effective mobility diminished these differences and enhanced the interinstrument reproducibility roughly by a factor 3. For (corrected) effective mobilities, intrainstrument reproducibilities were between 0.8-2.6% and interinstrument reproducibilities were between 3.2-3.9%.

Chromatography, Micellar Electrokinetic Capillary↗

Recent innovations in the use of charged cyclodextrins in capillary electrophoresis for chiral separations in pharmaceutical analysis.

A review is presented on the use of charged cyclodextrins (CDs) as chiral selectors in capillary electrophoresis (CE) for the separation of analytes in pharmaceutical analysis. An overview is given of theoretical models that have been developed for a better prediction of the enantiomeric resolution and for a better understanding of the separation mechanism. Several types of charged CDs have been used in chiral capillary electrophoretic separation (anionic, cationic, and amphoteric CDs). Especially the anionic CDs seem to be valuable due to the fact that many pharmaceutically interesting compounds can easily be protonated (e.g., amine groups). For that reason several anionic CDs are now commercially available. Cationic and amphoteric CDs are less common in chiral analysis and only a few are commercially available. Attention is paid to the most common synthesis routes and the characterization of the CDs used in chiral capillary electrophoretic separations. The degree of substitution in the synthesized CDs may vary from one manufacturer to another or even from batch to batch, which may have a detrimental effect on the reproducibility and ruggedness of the separation system. In Sections 4, 5, and 6 the applications of anionic, cationic, and amphoteric CDs for the chiral separation in CE are described. Many interesting examples are shown and the influence of important parameters on the enantioselectivity is discussed.

Cyclodextrins↗

Fluorescent-labeled ligands for the benzodiazepine receptor. Part 1: Synthesis and characterization of fluorescent-labeled benzodiazepines.

Because radioactive labeled ligands in receptor assays have several disadvantages, we synthesized a number of fluorescent-labeled benzodiazepines. Several fluorophores were attached at different positions of 1,4-benzodiazepine molecules in order to assess the impact of the fluorophores and their coupling position on the affinity for the benzodiazepine receptor. Besides the 1,4-benzodiazepines, the 1,2-annelated 1,4-benzodiazepines were also used for labeling. A metabolite of flumazenil (18), desethylflumazenil (Ro15-3890, 19), was labeled with the fluorophore 4-bromomethyl-7-methoxycoumarin, with and without the incorporation of a spacer chain, yielding the methyl-methoxycoumarin (Mmc) derivatives Mmc-Ro15-3890 (20a) and Mmc-O-CO-(CH2)3-Ro15-3890 (20b), respectively. After the synthesis, the fluorescent-labeled benzodiazepines were purified by HPLC, using an analytical RP-C18 column. For the purification of 20b, the chromatographic system was optimized, using multi-criteria decision making (MCDM) techniques. The binding affinities for the benzodiazepine receptor and the fluorescence characteristics were determined for the resulting products.

Animals↗

Fluorescent-labeled ligands for the benzodiazepine receptor. Part 2: The choice of an optimal fluorescent-labeled ligand for benzodiazepine receptor assays.

In this article, the binding affinities of the fluorescent-labeled benzodiazepines described in Part 1 are compared to assess the influence of the labeling position and the choice of fluorophore on the binding affinity. This comparison was extended by taking into account the data of other fluorescent-labeled benzodiazepines in the literature. The differences in the binding affinities observed could partly be explained by structure-activity relationships (SAR). On the basis of this comparison, fluorescent-labeled desethylflumazenil (Ro15-3890, 19) derivatives were selected as the most suitable labeled ligands in fluorescent receptor assays. A methyl-methoxycoumarin derivative (Mmc-O-CO-(CH2)3-Ro15-3890) (20b) had a Ki-value of 6.5 nM, and a 7-nitrobenz-2-oxa-1,3diazole derivative (NBD-NH-(CH2)3-Ro15-3890, 21) had a Ki-value of 5.7 nM. In order to yield sufficient sensitivity in the final receptor assay, a suitable fluorescent labeled ligand should have a Ki < 10 nM. A further advantage of the above two ligands is that the benzodiazepine moiety has no receptor affinity of its own. Thus, if some hydrolysis of the labeled ligand were to occur, the resulting Ro15-3890 (18) would hardly affect the outcome of the assay. In the second part of this paper the prerequisites of the fluorophore are being examined. In this regard, 20b is preferred, because the coumarin derivative has higher fluorescence intensities in aqueous media than the NBD-derivative. Therefore, 20b was selected as a fluorescent-labeled ligand in the development of a non-radioactive receptor assay for benzodiazepines.

Animals↗

On-line coupling of solid-phase extraction with mass spectrometry for the analysis of biological samples. I. Determination of clenbuterol in urine.

The potential of the direct coupling of solid-phase extraction (SPE) with mass spectrometry (MS) for the analysis of biological samples is demonstrated. For SPE a cartridge exchanger is used and the eluate is directly introduced into the mass spectrometer. This system has been investigated for the determination of clenbuterol in urine. With mixed-mode cartridges, a considerable ion suppression has been obtained. The mass spectrum at the elution time of clenbuterol is dominated by that of creatinine and adduct formation of clenbuterol and creatinine has been observed. The whole procedure including injection of 1 ml urine, washing and desorption has been developed with cartridges containing 8-microm C18-bonded silica. If only a single MS step is used, the selectivity and, therefore, the sensitivity are insufficient. The detection limit is about 100 ng/ml. However, with atmospheric pressure chemical ionisation and the tandem MS mode the detection limit has been decreased to about 2 ng/ml and the ion suppression is only about 10%. For the electrospray ionisation the detection limit is about 10-times higher and the ion suppression is less favourable. The repeatability for the SPE-MS-MS procedure was 6.5% at 10 ng/ml (n=5) and the difference between the response factors at 10 ng/ml and 100 ng/ml was only 2.5%. The MS behaviour of clenbuterol and the matrix under the present conditions is discussed.

Adrenergic beta-Agonists↗

Separation and identification of neuropeptide Y, two of its fragments and their degradation products using capillary electrophoresis-mass spectrometry.

This paper describes the development of an analytical method for the separation and identification of neuropeptide Y (NPY) and two important NPY fragments by capillary electrophoresis (CE) and mass spectrometry (MS). A satisfactory separation and the highest sensitivity were obtained with formic acid at high concentrations (250 mM, pH 2.75). The addition of 25 or 50 mM triethylamine (TEA) improved the separation. When applying full scan CE-MS, the separated peptides could be detected and identified using the spectra of each peak. The use of TEA as an additive to the formic acid slightly decreased the sensitivity but was compensated by the improved efficiency. The best compromise for optimal separation and MS detection was found to be 50 mM formic acid to which 50 mM TEA was added. CE-MS could be used for identification of the decomposition products of NPY. Decomposition products with one amino acid difference, which could not be distinguished with CE-UV, could be distinguished with CE-MS.

Amino Acid Sequence↗

Evaluation of capillary electrophoretic techniques towards systematic toxicological analysis.

Two capillary electrophoresis (CE) methods were evaluated for their suitability in systematic toxicological analysis (STA). A test set of 25 barbiturates was analysed using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). Buffers used consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate, 50 mM sodium dodecyl sulphate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries using an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA as it influences the identification power (IP). To deal with the poor reproducibility of the migration time, we introduced the corrected effective mobility. Inter-day reproducibilities of the latter parameter were < 0.6% for CZE and < 0.5% for MEKC, using daily prepared buffers. The IP of the methods was expressed by calculation of the discriminating power and the mean list length. Data obtained were compared to gas chromatographic and high-performance liquid chromatographic data, and correlations between all methods were calculated. It was shown that little correlation exists between chromatographic and electrophoretic techniques. The results indicated that CE has a good identification power for the application in STA, especially when a combination of methods having a low correlation is used.

Barbiturates↗

Selectivity in capillary electrokinetic separations.

This review gives a survey of selectivity modes in capillary electrophoresis separations in pharmaceutical analysis and bioanalysis. Despite the high efficiencies of these separation techniques, good selectivity is required to allow quantitation or identification of a particular analyte. Selectivity in capillary electrophoresis is defined and described for different separation mechanisms, which are divided into two major areas: (i) capillary zone electrophoresis and (ii) electrokinetic chromatography. The first area describes aqueous (with or without organic modifiers) and nonaqueous modes. The second area discusses all capillary electrophoretic separation modes in which interaction with a (pseudo)stationary phase results in a change in migration rate of the analytes. These can be divided in micellar electrokinetic chromatography and capillary electrochromatography. The latter category can range from fully packed capillaries, via open-tubular coated capillaries to the addition of microparticles with multiple or single binding sites. Furthermore, an attempt is made to differentiate between methods in which molecular recognition plays a predominant role and methods in which the selectivity depends on overall differences in physicochemical properties between the analytes. The calculation of the resolution for the different separation modes and the requirements for qualitative and quantitative analysis are discussed. It is anticipated that selectivity tuning is easier in separation modes in which molecular recognition plays a role. However, sufficient attention needs to be paid to the efficiency of the system in that it not only affects resolution but also detectability of the analyte of interest.

Electrophoresis, Capillary↗

Modelling of conditions for the enantiomeric separation of beta2-adrenergic sympathicomimetics by capillary electrophoresis using cyclodextrins as chiral selectors in a polyethylene glycol gel.

A two-factor central composite design was used to determine a mathematical model for prediction of the optimal conditions for the separation of the enantiomers of some widely used beta2-sympathicomimetic drugs (beta2-agonists) by capillary electrophoresis using cyclodextrins (CD) as a chiral selector in a polyethylene glycolgel. The effects of the chemical structure of these drugs along with the addition of polyethylene glycol to the cyclodextrin solution on the resolution of their enantiomers were studied. To allow impurity studies down to 0.1% (distomer eutomer) a resolution of 2.5 should be warranted. Those beta2-agonists containing two hydroxylic groups in the aromatic ring structure show the highest enantiomeric separation, due to the fact that one of their enantiomers has a better geometric structure to fit into the beta-cyclodextrin cavity.

Adrenergic beta-2 Receptor Agonists↗

Capillary electrophoresis as a versatile tool for the bioanalysis of drugs--a review.

This review article presents an overview of current research on the use of capillary electrophoretic techniques for the analysis of drugs in biological matrices. The principles of capillary electrophoresis and its various separation and detection modes are briefly discussed. Sample pretreatment methods which have been used for clean-up and concentration are discussed. Finally, an extensive overview of bioanalytical applications is presented. The bioanalyses of more than 200 drugs have been summarised, including the applied sample pretreatment methods and the achieved detection limits.

Chromatography, Micellar Electrokinetic Capillary↗

Improved benzodiazepine radioreceptor assay using the MultiScreen Assay System.

In this article, an improved benzodiazepine radioreceptor assay is described, which allows substantial reduction in assay time. The filtration in this method was performed by using the MultiScreen Assay System. The latter consists of a 96-well plate with glass fibre filters sealed at the bottom, which allows both the incubation and the filtration of the specimen in the same plate. After the filtration, the filters were punched out for quantitation of the bound labeled ligand [3H]flunitrazepam. The results obtained with the MultiScreen Assay System did not differ significantly from the data obtained with the conventional filtration manifold (48S): The Ki's of lorazepam were 2.4 +/- 0.30 and 1.9 +/- 0.15 nM, respectively. In case a radioactive label is replaced by a fluorescent label, the bound labeled-ligand usually cannot be determined in the presence of the receptor material. Here, the bound labeled-ligand has to be dissociated after the filtration step. To dissociate the ligand-receptor complex, Tris- HCl buffer, containing 10 microM flumazenil, was added to the filters and the second filtrates were collected containing the previously bound fractions in the absence of receptor material. This approach showed the same Ki for lorazepam, 2.5 +/- 0.04 nM as without dissociation, when using the radio-labeled benzodiazepine [3H]flunitrazepam.

Filtration↗

Detection of muscarinic receptors in the human lung using PET.

UNLABELLED: The characterization of pulmonary muscarinic receptors with PET is still in its infancy. Because approximately 70% of the lungs consists of air and pulmonary muscarinic receptor densities are low, ligands with high receptor affinity are required to obtain reasonable signal-to-noise ratios on PET images. Therefore, the potent 11C-labeled muscarinic antagonist N-methyl-piperidin-4-yl 2-cyclohexyl-2-hydroxy-2-phenylacetate methiodide ([R]-VC-002) was developed. We administered this radioligand to four healthy human volunteers to examine its suitability for studying pulmonary muscarinic receptors in vivo. METHODS: [11C]VC-002 (185 MBq, specific activity > 7.4 TBq/mmol) was intravenously injected on 2 separate days, with an interval of at least 1 wk. On the first day the volunteers were not pretreated, but on the second day they received the anticholinergic glycopyrronium bromide (Robinul; 2 x 0.1 mg intravenous) 25 and 30 min before the injection of the radiopharmaceutical. C[15O]O scans (approximately 740 MBq [20 mCi] by inhalation) were acquired before the receptor scan to calculate pulmonary blood volume. RESULTS: On PET images of the thorax, the lungs were clearly visible. After the volunteer was pretreated with glycopyrronium bromide, pulmonary uptake of the radioligand was reduced to 32%+/-12% of the control value at 60 min postinjection and the lungs could no longer be seen. (R)-[11C]-VC-002 was rapidly cleared from plasma and was slowly metabolized during the time course (60 min) of the PET scan. The fraction of radioligand representing parent compound decreased from 99.9% at the time of injection to 82% at 40-60 min postinjection, both in the presence and absence of Robinul. Pulmonary tissue-to-plasma ratios, calculated on a count-per-minute-per-gram basis, reached a plateau value of 17.8+/-1.2 at 40-50 min postinjection. CONCLUSION: [11C]VC-002 appears to be suitable for in vivo studies of pulmonary cholinoceptors.

Carbon Radioisotopes↗

Characterisation of beta2-adrenoceptors, using the agonist [11C]formoterol and positron emission tomography.

The agonist radioligand N-[2-hydroxy-5-[1-hydroxy-2-[[2-(4-[11C]-methoxyphenyl)-1-methylethyl]am ino]ethyl]phenyl]formamide ([11C]formoterol) was synthesised in order to test its ability to visualise pulmonary beta2-adrenoceptors in vivo, with positron emission tomography (PET). Formoterol was labelled via reaction of a dibenzyl-protected precursor with [11C]CH3I. Subsequent deprotection with Pd/C and H2 yielded [11C]formoterol in 5-15% (corrected for decay) and the specific activity ranged from 5.5-22.2 TBq mmol (150-600 Ci mmol(-1)), 60-70 min after end of bombardment. Biodistribution studies with [11C]formoterol were performed in male Wistar rats which were either untreated or predosed with (D,L)-propranolol hydrochloride (2.5 mg kg(-1), beta-adrenoceptor antagonist), erythro-DL-1-(7-methylindan-4-yloxy)-3-isopropylaminobuta n-2-ol hydrochloride (ICI 118551, 0.15 mg kg(-1), beta2-adrenoceptor antagonist), isoprenaline (15 mg kg(-1), non-subtype selective beta-adrenoceptor agonist) or (+/-)-(2-hydroxy-5-[2-((2-hydroxy-3-(4-((1-methyl-4-trifluoromethyl)1H-i midazol-2-yl-)phenoxy)propyl)amino)ethoxy]benzamide)monomethane sulfonate (CGP 20712A, 0.15 mg kg(-1), beta1-adrenoceptor antagonist). Lungs, heart, liver and plasma were analysed for radioactive metabolites. The kinetics of [11C]formoterol in the lungs of male Wistar rats were investigated by means of a dynamic PET study. The biodistribution studies showed significant specific binding in tissues known to contain beta2-adrenoceptors (lungs, spleen, and heart). Binding in these organs was blocked by ICI 118551 and isoprenaline, but not by CGP 20712A. [11C]Formoterol was rapidly metabolised in rats but lungs and heart did not substantially take up the labelled metabolites. The binding of [11C]formoterol in various tissues of rats is consistent with the beta2-selectivity of formoterol. Whether [11C]formoterol selectively binds to the high affinity state of beta2-adrenoceptors remains to be elucidated. [11C]Formoterol is potentially useful for studying beta2-adrenoceptors with PET and this radioligand may provide new insights in the mechanisms underlying prolonged sympathomimetic action.

Adrenergic beta-Agonists↗

Determination of the enantiomeric purity of (-) terbutaline by capillary electrophoresis using cyclodextrins as chiral selectors in a polyethylene glycol gel.

A method was developed for determination of the enantiomeric purity of the therapeutic-pharmacological active (-)-enantiomer of terbutaline using cyclodextrins as a chiral selector dissolved in a removable liquid polyethylene glycol gel by use of capillary electrophoresis. The effect of temperature, type and concentration of polyethylene glycol and cyclodextrins was studied on the resolution between the two enantiomers. Best results were obtained with 10 mM hydroxyethyl-beta-cyclodextrin dissolved in a 10% polyethylene glycol-2000 solution at 15 degrees C. Under these conditions, an impurity of 0.1% (distomer/eutomer) can be readily detected.

Chemistry Techniques, Analytical↗

Evaluation of a novel diffusion cell for in vitro transdermal permeation: effects of injection height, volume and temperature.

The objective of this study was to evaluate the performance of a new, compact, dynamic diffusion cell for in vitro transdermal permeation. These so-called Kelder-cells were developed as an automated alternative to the static Franz diffusion cells. The new cells were used in combination with the ASPEC-system (automatic sample preparation with extraction columns) which was initially designed for the automation of solid-phase extractions. Three variables were tested to optimize the performance of the new cell system: injection height into the inlet compartment, volume flowing through the receptor compartment and temperature. Experiments were performed using the tritium labelled anticholinergic [3H]dexetimide permeating through an artificial membrane (Silastic). The injection height of the needle into the inlet compartment of the cell should be programmed at -34 mm to ensure complete air tightness, thus forcing the buffer to flow through the cell. The volume of buffer flow through the receptor compartment is important in maintaining sink conditions: a volume of 117 microliters was chosen to replace the total content of the cell (84 microliters) every 2 min. The temperature was precisely controlled in a thermostatic cabinet to minimize variations in experimental conditions. For [3H]dexetimide, an increase in temperature of 20 degrees C reduced the lag time by a factor of approximately two, however the influence on the flux was negligible. The data for the Kelder-cells were comparable with static Franz diffusion cells at a pseudo-steady state, however Kelder-cells have the advantage of automatic sampling, continuous replacement of the receptor solution, and unattended operation over at least 24 h.

Administration, Cutaneous↗

Size-exclusion chromatographic reconstitution of the bovine brain benzodiazepine receptor. Effects of lipid environment on the binding characteristics.

The benzodiazepine receptor from calf brain was solubilized with sodium deoxycholate (2 mg/ml) in the presence of 0.5 M KCl and protease inhibitors, and bound flunitrazepam with an equilibrium dissociation constant (Kd) of 2.7 +/- 1.2 nM and with 0.40 +/- 0.04 pmol binding sites per mg protein (Bmax). Up to 60% of the benzodiazepine binding sites (average 25%) could be reconstituted in lipid vesicles, upon size-exclusion chromatography of protein-detergent-lipid mixtures on Sephadex G-50 Medium for detergent depletion. The flunitrazepam affinity for the reconstituted receptor varied with the lipid composition (Kd 1.4-4 nM). Freezing and thawing increased the size of the small proteoliposomes obtained by chromatographic reconstitution and, on the average, doubled the number of operative flunitrazepam binding sites. When the proteoliposomes were stored at -20 degrees C or -80 degrees C or in lyophilized state, the receptor retained its benzodiazepine binding affinity and Bmax over a period of 2 months.

Animals↗