Detection of motion in hybrid PET/SPECT imaging based on the correlation of partial sinograms.

This paper describes a motion detection method specific to hybrid positron emission tomography/single photon emission computed tomography systems. The method relies on temporal fractionation of the acquisition into three data sets followed by an algorithm based on the cross correlation (CC) of partial sinograms from successive sets at different rotations of the camera. Spatial inconsistencies due to motion are detected by decreases in the CC between two sets. This permits to separate data into premotion and postmotion sets of consistent data that are reconstructed independently then registered and summed. Rigid motions greater than 1-cm translation or 10 degrees rotation were detected with this method from experimental data obtained by manually moving phantoms made of radioactive spheres as well as from a patient lung study corrupted by artificial motion. The different motion studies showed that the image contrast does not seem to be a limiting factor and that the motion is best detected when the gantry is parallel to the direction of motion. The registration and fusion of the reconstructed premotion and postmotion sets lead in all cases to a reduction of the motion artifacts and an increase in signal-to-noise ratio.

Algorithms↗

Cerebral glucose metabolism measured by positron emission tomography in term newborn infants with hypoxic ischemic encephalopathy.

Total and regional cerebral glucose metabolism (CMRgl) was measured by positron emission tomography with 2-((18)F) fluoro-2-deoxy-D-glucose ((18)FDG) in 20 term infants with hypoxic ischemic encephalopathy (HIE) after perinatal asphyxia. All infants had signs of perinatal distress, and 15 were severely acidotic at birth. Six infants developed mild HIE, twelve moderate HIE, and two severe HIE during their first days of life. The positron emission tomographic scans were performed at 4-24 d of age (median, 11 d). One hour before scanning, 2-3.7 MBq/kg (54-100 microCi/kg) (18)FDG was injected i.v. No sedation was used. Quantification of CMRgl was based on a new method employing the glucose metabolism of the erythrocytes, requiring only one blood sample. In all infants, the most metabolically active brain areas were the deep subcortical parts, thalamus, basal ganglia, and sensorimotor cortex. Frontal, temporal, and parietal cortex were less metabolically active in all infants. Total CMRgl was inversely correlated with the severity of HIE (p < 0.01). Six infants with mild HIE had a mean (range) CMRgl of 55.5 (37.7-100.8) micromol.min(-1).100 g(-1), 11 with moderate HIE had 26.6 (13.0-65.1) micromol.min(-1).100 g(-1), and two with severe HIE had 10.4 and 15.0 micromol.min(-1).100 g(-1), respectively. Five of six infants who developed cerebral palsy had a mean (range) CMRgl of 18.1 (10.2-31.4) micromol.min(-1).100 g(-1) compared with 41.5 (13.0-100.8) micromol.min(-1).100 g(-1) in the infants with no neurologic sequela at 2 y. We conclude that CMRgl measured during the subacute period after perinatal asphyxia in term infants is highly correlated with the severity of HIE and short-term outcome.

Brain↗

Registration of emission and transmission whole-body scintillation-camera images.

UNLABELLED: In this work, a method for registration of whole-body (WB) scintillation-camera images is presented. The primary motive for the development is to perform activity quantification using the conjugate view method on an image basis. Accurate image registration is required for sequential anterior and posterior scans, for serial emission images for analysis of the biokinetics, and for transmission and emission images for a pixel-based attenuation correction. METHODS: Registration is performed by maximization of the mutual information. The spatial transformation has been tailored for the registration of WB images and is composed of global and local transformations, including rigid, projective, and curved transformations. A coarse registration is first performed using cross-correlation and direct pixel scaling. Optimization is then performed in a sequence, beginning with the 2 legs independently, followed by the upper body and head. Evaluation is performed for clinical images of an (131)I-labeled monoclonal antibody and for Monte Carlo-simulated images. An anthropomorphic WB computer phantom, which has been especially modified to match the patient position during WB scanning, is used for the simulations. RESULTS: For simulated images, registration errors are within 1 pixel (<3.6 mm) for a sufficient image count level. Separate evaluation of the influence of noise shows that the errors increase below a total image count of approximately 10(5) (signal-to-noise ratio, approximately 4). For clinical evaluations, the deviations between point markers are 9 +/- 5 mm. CONCLUSION: An automatic registration method for WB images has been developed, which is applicable to emission-emission and transmission-emission registration. This method has been applied in more than 50 clinical studies and has shown to be robust and reliable.

Gamma Cameras↗

Intercomparison of four reconstruction techniques for positron volume imaging with rotating planar detectors.

Four reconstruction techniques for positron volume imaging have been evaluated for scanners based on rotating planar detectors using measured and simulated data. The four techniques compared are backproject then filter (BPF), the 3D reprojection (3D RP) method for 3D filtered backprojection (FBP), Fourier rebinning (FORE) in conjunction with 2D FBP (FORE + 2D FBP) and 3D ordered subsets expectation maximization (3D OSEM). The comparison was based on image resolution and on the trade-off between contrast and noise. In general FORE + 2D FBP offered a better contrast-noise trade-off than 3D RP, whilst 3D RP offered a better trade-off than BPF. Unlike 3D RP, FORE + 2D FBP did not suffer any contrast degradation effect at the edges of the axial field of view, but was unable to take as much advantage from high-accuracy data as the other methods. 3D OSEM gave the best contrast at the expense of greater image noise. BPF, which demonstrated generally inferior contrast-noise behaviour due to use of only a subset of the data, gave more consistent spatial resolution over the field of view than the projection-data based methods, and was best at taking full advantage of high-accuracy data.

Computer Simulation↗

Fast accurate iterative reconstruction for low-statistics positron volume imaging.

A fast accurate iterative reconstruction (FAIR) method suitable for low-statistics positron volume imaging has been developed. The method, based on the expectation maximization-maximum likelihood (EM-ML) technique, operates on list-mode data rather than histogrammed projection data and can, in just one pass through the data, generate images with the same characteristics as several ML iterations. Use of list-mode data preserves maximum sampling accuracy and implicitly ignores lines of response (LORs) in which no counts were recorded. The method is particularly suited to systems where sampling accuracy can be lost by histogramming events into coarse LOR bins, and also to sparse data situations such as fast whole-body and dynamic imaging where sampling accuracy may be compromised by storage requirements and where reconstruction time can be wasted by including LORs with no counts. The technique can be accelerated by operating on subsets of list-mode data which also allows scope for simultaneous data acquisition and iterative reconstruction. The method is compared with a standard implementation of the EM-ML technique and is shown to offer improved resolution, contrast and noise properties as a direct result of using improved spatial sampling, limited only by hardware specifications.

Image Processing, Computer-Assisted↗

An alternative method to normalize clinical FDG studies.

UNLABELLED: An alternative method of determining the integrated input function, necessary in the quantitative [18F]fluorodeoxyglucose (FDG) autoradiographic model, has been developed. Using erythrocytes as reference tissue, researchers require only one blood sample after injection of FDG to obtain the integrated input function. METHODS: The amount of FDG-6-PO4 in the erythrocytes is proportional to their exposure to FDG, that is, the integrated input function. Free FDG is removed by washing the erythrocytes twice. Inter- and intraindividual differences of the metabolic rate of erythrocytes are corrected for by an in vitro incubation with a known amount of FDG. RESULTS: Validation of the proposed method was done by correlating the integrated input function, based on the glucose metabolism of the erythrocytes, to the integrated input function obtained by multiple venous blood samples. The new method provides the integrated input function with an accuracy better than +/-8%. CONCLUSION: By using erythrocytes as a reference tissue, researchers can determine the integrated input function in the quantitative FDG autoradiographic model with an accuracy sufficient for clinical PET studies. The simplicity of the method also makes it suitable for FDG studies on small children. With two samples, the method can also be used for a simplified graphical Patlak analysis.

Erythrocytes↗

Early prediction of treatment outcome in head and neck cancer with 2-18FDG PET.

The development of alternative treatment regimens in clinical oncology has increased the need for early prediction of cancer therapy outcome. The aim of this study was, early in the treatment phase, to identify patients with advanced head and neck cancer, responding or not responding to initiated therapy. The tumour metabolic rate of glucose (MRgl) examined by 2-18FDG-PET was determined in 17 patients before and after the first weeks of either radiotherapy (16-35 Gy) or one course of combination chemotherapy. Metabolic values uptake values normalized to plasma activity integrals--were correlated to loco-regional outcome, as evaluated 5-6 weeks after completion of treatment. Initial low tumour MRgl (<20 micromol/min/100 g tissue), in primary lesions or regional metastases, predicted a local complete response. When a high initial tumour MRgl was found, the magnitude of the reduction of MRgl in the second PET examination might be an adjunct in predicting local tumour response.

Adult↗

Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator.

The purpose of this study was to evaluate the accuracy of myocardial imaging by means of high-resolution single-photon emission tomography (SPET) with a pinhole collimator in rats with experimental infarction. Myocardial infarctions were induced in male Wistar rats by ligation of the left coronary artery for 30 min, followed by reperfusion. Two days after the reperfusion, pinhole SPET was performed after the intravenous administration of 111 MBq of thallium-201 chloride, using a rotating gamma camera equipped with a pinhole insert (2.0-mm aperture) in a low-energy pinhole collimator. SPET projection data were collected at 6 degrees increments over 360 degrees using a 4-cm radius of rotation to reconstruct the short- and long-axis images. Projection data were acquired in 15 or 30 s, the SPET imaging being accomplished within 40 min after the injection of 201Tl. After SPET, the rats were sacrificed to remove the hearts for autoradiography (ARG) and nitroblue tetrazolium (NBT) staining as a visual correlative study. Quantitative correlative studies between pinhole SPET and ARG were performed with linear regression analysis for infarct size and distribution properties (relative counts on SPET images and relative density on autoradiographs) on the short-axis sections. All infarcts (4 mm in minimum diameter) in seven rats were detected by pinhole SPET. The SPET images in rats with or without myocardial infarction were consistent with the findings of ARG and NBT staining. There were significant correlations between pinhole SPET and ARG with respect to the infarct size (r=0.933, P <0.001; n=15) and the relative radiotracer distribution (r=0.931, P <0.001; n=68). This study therefore confirmed the accuracy of myocardial pinhole SPET imaging in rats with myocardial infarction. This method may partially substitute for ARG and prove useful for assessing new myocardial imaging agents in vivo in small laboratory animals.

Animals↗

Small animal imaging with pinhole single-photon emission computed tomography.

BACKGROUND: High resolution spatial details of the distribution of activity in three dimensions is required to evaluate the localization and dosimetric properties of radiolabelled monoclonal antibodies in tumors and normal tissues. Planar imaging of small animals with a resolution of 5-10 mm is usually the imaging modality of choice. The authors investigated high resolution single-photon emission computed tomographic (SPECT) imaging, based on a rotating pinhole scintillation camera. Although the sensitivity of the pinhole collimator is low, several radionuclides offer suitable decay properties to perform pinhole SPECT, especially in conjunction with high activity levels used in radioimmunotherapy. METHODS: Transverse, sagittal, and coronal sections were reconstructed using a three-dimensional cone-beam algorithm, which is a generalization of the two-dimensional fan-beam filtered backprojection algorithm. Before reconstruction, the pinhole projections were corrected for the decay of the radionuclide, geometric and intrinsic efficiency variations of the camera system, and center of rotation shift. RESULTS: The spatial resolution at 50 mm from the pinhole collimator with 3.3 mm aperture was 3.4 mm, and the sensitivity 7.2 c/s microCi for technetium-99m. With the 2 mm collimator the resolution was 2.2 mm, and the sensitivity was 2.6 c/s/microCi. To show the spatial resolution in vivo, a rat was injected with 185 MBq of technetium-99m-methylene diphosphonate or with 5 mCi technetium-99m-hexamethylpropylene amine oxime. The bone structures were well delineated in the methylene diphosphonate image, and in the hexamethylpropylene amine oxime image, the brain was nicely shown. For comparison a magnetic resonance image for the same section was done. CONCLUSIONS: High resolution SPECT imaging with the pinhole collimator provides mapping of the activity in three-dimensions, needed for more detailed biodistribution data and to perform more accurate dosimetry.

Algorithms↗

Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals.

UNLABELLED: The performance of pinhole SPECT and the application of this technology to investigate the localization properties of radiopharmaceuticals in vivo in small laboratory animals are presented. METHODS: System sensitivity and spatial resolution measurements of a rotating scintillation camera system are made for a low-energy pinhole collimator equipped with 1.0-, 2.0- and 3.3-mm aperture pinhole inserts. The spatial detail offered by pinhole SPECT for in vivo imaging was investigated in studies of the brain and heart in Fisher 344 rats by administering 201TICI, 99mTc-HMPAO, 99mTc-DTPA and 99mTc-MIBI. Image acquisition is performed using a rotating scintillation camera equipped with a pinhole collimator; projection data are acquired in conventional step-and-shoot mode as the camera is rotated 360 degrees around the subject. Pinhole SPECT images are reconstructed using a modified cone-beam algorithm developed from a two-dimensional fanbeam filtered backprojection algorithm. RESULTS: The reconstructed transaxial resolution of 2.8 mm FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0-mm pinhole collimator aperture provide excellent spatial detail and adequate sensitivity for imaging the regional uptake of the radiopharmaceuticals in tumor, organs and other tissues in small laboratory animals. CONCLUSION: The resolution properties of pinhole SPECT are superior to those which have been achieved thus far with conventional SPECT or PET imaging technologies. Pinhole SPECT provides an important approach for investigating localization properties of radiopharmaceuticals in vivo.

Animals↗

High resolution pinhole SPECT for tumor imaging.

High-resolution, non-invasive, 3D-imaging techniques would greatly benefit the investigation of the localization properties of tumor-specific radiopharmaceuticals in laboratory animals. The present study reports how pinhole SPECT can be applied to tumor localization studies in small laboratory animals to provide high resolution SPECT images in vivo. Pinhole SPECT was performed using a rotating scintillation camera, equipped with a pinhole collimator. The sensitivity of a 2 mm diameter collimator at 45 mm from the source is 90 cps/MBq for 99mTc. The planar spatial resolution at a 45 mm distance is 2.2 mm. The transaxial spatial resolution, with a distance of 45 mm between the collimator aperture and the axis of rotation, is 3.1 mm. For SPECT imaging, spatial linearity is preserved across the usable field-of-view. The major advantage of the high resolution properties of pinhole tomography is demonstrated by the enhanced lesion-to-normal-brain uptake ratio achieved on tomographic slices as compared to planar images. For example, 201Tl tumor-to-normal-brain uptake ratios of 1.1 to 1.3 observed on planar images, corresponded to ratios ranging from 3.2 to 3.7 on the SPECT slices. Examples of the activity distributions of two radiopharmaceuticals in tumor and in normal brain for sagittal and coronal images are given. In all cases, tumors are clearly delineated on the pinhole SPECT slices. The present study shows that pinhole SPECT performed with standard SPECT instrumentation can give high spatial resolution images, with a FWHM approximately 3 mm and a sensitivity approximately 100 cps/MBq for 99mTc.

Animals↗

A PET system based on 2-18FDG production with a low energy electrostatic proton accelerator and a dual headed PET scanner.

We have developed a comparatively inexpensive PET system, based on a rotating scanner with two scintillation camera heads, and a nearby low energy electrostatic proton accelerator for production of short-lived radionuclides. Using a 6 MeV proton beam of 5 microA, and by optimization of the target geometry for the 18O(p,n)18F reaction, 750 MBq of 2-18FDG can be obtained. The PET scanner shows a spatial resolution of 6 mm (FWHM) and a sensitivity of 80 s-1kBq-1ml-1 (3 kcps/microCi/ml). Various corrections are included in the imaging process, to compensate for spatial and temporal response variations in the detector system. Both filtered backprojection and iterative reconstruction methods are employed. Clinical studies have been performed with acquisition times of 30-40 min. The system will be used for clinical experimental research with short- as well as long-lived positron emitters. Also the possibility of true 3D reconstruction is under evaluation.

Astrocytoma↗

Thyroid uptake of iodine-131 and iodine-133 from Chernobyl in the population of southern Sweden.

The accident at the nuclear power plant of Chernobyl on April 26, 1986 led to radioactive contamination of many countries including Sweden. The population was exposed to released radionuclides, both by inhalation and from contaminated food. We have studied the content of gamma-emitting radioisotopes in the thyroid glands of a normal population from southern Sweden using measurements of samples taken at autopsy. The first samples are from a person who died on April 27, 1986. This report contains results for 131I and 133I. The time-activity curve for 131I shows an immediate uptake with a maximum 18-26 days after the accident. No measurable levels were observed after 93 days. We have found that the increase in dose equivalent to the thyroid for the population of southern Sweden due to the released 131I and 133I will be less than 0.1 mSv. This may lead to an increase in the incidence of thyroid cancer of 0.1% during a period of 25 yr.

Accidents↗