PubMed Health⌕ Search

Biomedical subjects

K F Kreitner

Publications and source records attributed to K F Kreitner.

At least 19 recordsLinked to original sources

Early detection of sternal dehiscence by conventional chest X-ray.

BACKGROUND: Diagnosis of sternal dehiscence after sternotomy for cardiac surgery is still made clinically. The aim of this study was to identify radiographic signs of sternal dehiscence by routine chest X-ray (CXR) in patients with and without clinically diagnosed sternal dehiscence. METHODS: 75 patients (group I: 65 +/- 9.3 years, f/m = 12/63) with clinically diagnosed sternal dehiscence, necessitating surgical revision and 75 patients with uneventful sternal healing (matched to group I by age, sex, preoperative risk factors and surgical procedures; group II: 66 +/- 9.0 years, f/m = 12/63) were included in this study. Serial CXRs immediately after surgery until re-intervention or discharge were analyzed by a radiologist, blind to the date of redo surgery. RESULTS: In 39 patients of group I (52%) vs. 8 (10.7%) in group II, abnormalities in the sternal wire and/or a midsternal stripe could be found (p < 0.0001): rotated wires (p = 0.003), shifted wires (p = 0.043), and ruptured wires (p = 0.312). Seven patients presented with combined wire abnormalities in group I vs. 0 in group II. Midsternal stripe sign could be detected in 26 patients of group I vs. 3 in group II (p < 0.0001). Sternal dehiscence was suspected based on the above mentioned abnormalities as early as three days postoperatively (Q1 = 2; Q3 = 8 days) in 39 patients, whereas clinical diagnosis of sternal dehiscence was delayed up to ten days postoperatively (Q1 = 7; Q3 = 13 days). CONCLUSIONS: Radiographic signs of sternal dehiscence could be detected before the clinical diagnosis was apparent and predicted sternal dehiscence in more than half of the patients.

Aged↗

Assessment of the distal anastomosis of coronary artery bypass grafts with a 2D T2-weighted turbo spin echo sequence and correlation to conventional coronary angiography.

OBJECTIVE: The aim of the study was to evaluate the patency of the distal anastomoses of coronary artery bypass grafts and to detect graft stenoses and occlusions with a magnetic resonance (MR) spin echo sequence. PATIENTS AND METHODS: One hundred and eighty-five patients with 481 distal anastomoses were examined with a 1.5 T MR scanner and coronary angiography. A 2-dimensional T2-weighted breath-hold half-Fourier acquisition single-shot turbo spin echo sequence (Haste) was performed. All images were evaluated independently by a radiologist and cardiologist and compared to the conventional coronary angiography. The observers were blinded to the coronary angiography findings, but informed in regard to the surgical graft anastomosis. RESULTS: With the Haste sequence, 76% of the distal anastomoses were recognized (368/481). Forty-five of 52 (87%) stenoses and all occlusions were identified. The sensitivity and specificity for the evaluation of the distal anastomosis with the spin echo sequence was 87% and 96%. Twenty-four percent of the distal anastomoses were not identified due to a poor image quality or motion artefacts. CONCLUSION: Using the Haste sequence, a reliable assessment of graft patency of the distal anastomosis is possible. Further improvements of the spatial resolution and the image quality are necessary to recommend this MR technique for routine clinical use.

Adult↗

[MRT-induced burns in tattooed patients. Case report of an traumatic surgery patient].

Skin burns to patients with tattoos during MRI procedures are reported but rare complications. MRI scans are being used more often also as diagnostic procedures in trauma patients. In this article we present the case of a patient after trauma of the vertebral column who experienced burning pain at the site of a tattoo on the distal femur during the MRI examination, necessitating cessation of this procedure. Based on this example we discuss possible pathomechanisms of MRI-induced skin burns to patients with tattoos. It becomes clear that patients have to be asked about possible tattoos before MRI scans and should be informed about possible pain development.

Burns, Electric↗

[Indirect MR-arthrography in the follow up of autologous osteochondral transplantation].

PURPOSE: To evaluate the spectrum of findings in indirect MR-arthrography following autologous osteochondral transplantation. PATIENTS AND METHODS: 10 patients with autogenous osteochondral homografts underwent indirect MR-arthrography at three, 6 and 12 months postoperatively. The MR protocol at 1.5 T comprised unenhanced imagings with PD- and T2 -weighted TSE- sequences with and without fat-suppression as well as T1 -weighted fat-suppressed SE-sequences before and after i.v. contrast administration and after active joint exercise. Image analysis was done by two radiologists in conference and comprised the evaluation of signal intensity (Sl) and integrity of the osseous plug and the cartilage surface, as well as the presence of joint effusion or bone marrow edema. RESULTS: At three months, all cases demonstrated a significant bone marrow edema at the recipient and donor site that corresponded to a significant enhancement after i.v. contrast administration. The interface between the transplant and the normal bone showed an increased Sl at three and 6 months in T2 -weighted images as well as in indirect MR-arthrography. The marrow signal normalized in most cases after 6 to 12 months, indicating vitality and healing of the transplanted osteochondral graft. The Sl of the interface decreased in the same period, demonstrating the stability of the homograft at the recipient site. The osteochondral plugs were well-seated in 9/10 cases. Indirect MR-arthrography was superior to unenhanced imaging in the assessment of the cartilage surface. Cartilage coverage was complete in every case. The transplanted hyaline cartilage as well as the original cartilage showed a significant increase of the Sl in indirect MR-arthrography, that did not change in follow up studies. There were no pathological alterations of signal and thickness alterations of the transplanted cartilage in follow up investigations. CONCLUSION: Indirect MR-arthrography is a useful diagnostic tool following autologous osteochondral transplantation. Assessment of transplant vitality, osseous fixation and stability is possible.

Adolescent↗

Late improvement of regional wall motion after the subacute phase of myocardial infarction treated by acute PTCA in a 6-month follow-up.

BACKGROUND: The aim of this follow-up study was to investigate the late effects of acute coronary angioplasty (PTCA) on regional wall motion after the subacute phase of myocardial infarction (MI). METHODS AND RESULTS: Seventeen patients were investigated initially at a median of 11 days and again at 6 months after acute PTCA for myocardial infarction (< 8 hours after onset of symptoms) by cardiac magnetic resonance imaging. Corresponding short-axis slices encompassing the left ventricle (LV) were acquired using a standard cine MR for regional wall motion analysis and using delayed contrast enhanced magnetic resonance imaging (ceMRI) for infarct size quantification. The infarct size was similar in the subacute phase and the 6 month follow-up (20.8 and 21.9%, respectively; n.s.). Regional wall motion improved significantly in the area of hyperenhancement [percentage wall thickening (PWT) 21.9% and 37.9%, p < 0.05] in contrast to remote normal myocardium (46.4% and 38.4%; n.s.). Regional wall motion was significantly poorer in transmural compared with nontransmural MI in the subacute stage, and a late improvement could only be observed in transmural MI. CONCLUSION: Transmural areas of hyperenhancement displayed significant late long-term improvement of regional wall motion after acute PTCA, possibly related to prolonged stunning compared with nontransmural areas.

Adult↗

Non-invasive magnetic resonance imaging of coronary bypass grafts. comparison of the haste- and navigator techniques with conventional coronary angiography.

OBJECTIVE: The aim was the study was to evaluate the patency of coronary artery bypass grafts with the 3D Navigator and the Haste magnetic resonance imaging techniques. MATERIAL AND METHODS: Thirty-four patients with 82 grafts (18 internal mammarian artery and 64 saphenous venous grafts) were examined at 1.5 T using a phased arrray body coil. A 2D T-2 weighted turbo spin echo sequence (Haste) and a 3D-angiography sequence in navigator technique were used. Reference method was the conventional coronary angiography that was performed within 7 days. RESULTS: With the HASTE sequence 54 of 56 patent and 12 of the 16 occluded grafts were recognized, the sensitivity and specificity was 96 and 75%. The distal anastomosis could be assessed in 28 of 76 cases. With the Haste sequence 54 of the 56 patent and 12 of the 14 occluded grafts were detected correctly. Eight patent and two occluded grafts were judged as not assessable. The sensitivity and specificity was 96 and 85%. Sixty-six percent (50/76) of the distal anastomosis were identified correctly. With both sequences none of the bypass stenosis could be detected. CONCLUSIONS: The patency of coronary bypass grafts can be evaluated noninvasively with a sensitivity of 96% and a specificity of 76%. No inference can be made with respect to the nature of bypass graft stenosis. Better results can be expected with the development of a blood pool contrast medium, an improvement of the spatial resolution and in the combination of flow measurements.

Aged↗

[Evaluation of myocardial perfusion reserve in patients with CAD using contrast-enhanced MRI: a comparison between semiquantitative and quantitative methods].

OBJECTIVE: Comparison between two semiquantitative methods and a quantitative evaluation of myocardial blood flow (MBF) for assessment of myocardial perfusion reserve (MPR) in patients with CAD. MATERIAL AND METHODS: 9 patients with coronary stenoses > 50 % were examined with an ECG-gated Saturation Recovery Turbo FLASH sequence by using Gd-DTPA as contrast agent (CA). The entive measurements were performed both during rest and hyperemia induced by adenosine. The up-slopes of the signal-time S(t) curves in the myocardium and left ventricular (LV) cavity were evaluated by a linear fit. MPR was calculated from the original up-slopes of the myocardial S(t) curves and from the up-slopes, which were normalized to the up-slopes of the LV S(t) curves, respectively. For quantification of MBF values, the mathematical model MMID 4 was used and MPR was evaluated from the MBF values. RESULTS: With all tested methods, MPR was reduced in myocardial regions subtended by arteries with stenoses >/= 70 % compared with remote regions. With MMID 4 and the normalized up-slope method, differences between severe ischemic and remote regions were statistically significant. CONCLUSION: The up-slope method with normalization and quantification with MMID 4 are more sensitive methods to differentiate between remote and ischemic myocardium than the up-slope method without normalization.

Adult↗

[Morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature by breath-hold MR techniques].

PURPOSE: To evaluate breath-hold MR techniques for morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature. PATIENTS AND METHODS: 13 patients aged 11 to 60 years with different vascular abnormalities of the pulmonary vasculature (5 patients with 16 arteriovenous malformations, 8 patients with partial anomalous pulmonary venous return) underwent MR imaging at 1.5 T. For morphological assessment, a contrast-enhanced 3D MR angiography (ce-MRA) was performed after a timing run. Segmented cine- and velocity-encoded GRE sequences were used for delineation of associated cardiac septal defects and for determination of systemic left-to-right or intrapulmonary shunt volumes. Selective intra arterial digital subtraction angiography, cardiac catheterization, and the intraoperative situs served as reference standards. RESULTS: Ce-MRA allowed for detection of all vascular abnormalities and for anatomic characterization of 14/16 arteriovenous malformations. Flow measurements in the feeding arteries allowed for determination of intrapulmonary shunt volumes in 4/5 patients. Flow measurements performed in the pulmonary arteries and the ascending aorta enabled determination of systemic left-to-right shunting in patients with anomalous pulmonary venous return. Cine-sequences clearly depicted associated cardiac septal defects. CONCLUSION: Breath-hold MR techniques allow for morphological and functional characterization of vascular anomalies of the pulmonary vasculature. Therefore, they are the non-invasive method of choice for planning further treatment.

Adolescent↗

[Cardiac MRI in suspected myocarditis].

PURPOSE: To evaluate the potential of ECG-gated breath-hold MRI in diagnosing acute myocarditis. MATERIAL AND METHODS: Cardiac MRI was performed on 21 consecutive patients with suspected myocarditis. ECG-gated breath-hold T2-weighted images with fat suppression were acquired in 3 standard views. T1-weighted imaging (FLASH) was performed 10 min after IV administration of Gd-DTPA. Laboratory data included creatine kinase, troponin T and serological tests, ECG findings and echocardiography. Imaging findings were retrospectively compared to the discharge diagnoses. Signal alterations were semiquantitatively classified. RESULTS: Acute myocarditis was diagnosed in 9 patients and cardiac sarcoidosis in 2 patients. Late enhancement was observed in 4 patients with acute myocarditis and in both patients with cardiac sarcoidosis. Semiquantitative evaluation revealed 9 true positive, 9 true negative, 1 false positive and 2 false negative results. CONCLUSION: Cardiac MRI has the potential to detect acute myocarditis and to diagnose cardiac sarcoidosis. Late enhancement of Gd-DTPA can be found in both viral myocarditis and cardiac sarcoidosis.

Acute Disease↗

[New developments in MRI of the thorax].

MRI was not used often for lung imaging due to technical and physical limitations. Recent developments have considerably improved anatomical MR imaging, and at the same time new perspectives for functional imaging emerged. They consist of functional investigations of pulmonary perfusion (contrast agents, MR angiography) and ventilation (inhaled contrast aerosols, oxygen, hyperpolarized noble gases [He-3, Xe-129] and fluorinated gases [SF6]). New parameters can be measured: homogeneity of ventilation, lung volumes, airspace size, intrapulmonary oxygen partial pressure, dynamic ventilation distribution and ventilation/perfusion ratios. MRI-inherent advantages are: lack of radiation, high spatial and temporal resolution, and a broad range of functional information. MRI of lung ventilation seems to be more sensitive in the detection of ventilation defects than scintigraphy, CT or pulmonary function tests. By combining the new strategies the radiologist will be capable to improve specificity of the investigations and to characterize lung function impairments. The joint assessment of ventilation and perfusion will play a major role in this development.

Contrast Media↗

Contrast-enhanced three-dimensional MR angiography of the thoracic aorta: experiences after 118 examinations with a standard dose contrast administration and different injection protocols.

The aim of this study was to test three injection protocols for contrast-enhanced magnetic resonance angiography (MRA) of the thoracic aorta with a standard-dose application. Ninety-three patients with a total of 118 examinations underwent MRA of the thoracic aorta at 1.5 T. There were three injection protocols: in 24 cases, no test bolus was performed and contrast was injected manually; in 14 cases, contrast was injected manually after a test bolus; and in 80 cases, a MR-compatible injector was used after a timing examination. All patients received 20 ml of Gd-DTPA. Quantitative signal-to-noise (SNR) measurements were obtained at different locations in the thoracic aorta, the pulmonary arteries, and the superior vena cava. Two readers in conference retrospectively evaluated each examination with respect to overall image quality and quality of bolus timing. Bolus timing was considered optimal in 70 cases, and either too early or too late in 11 cases. In 37 examinations the bolus was broadened. The SNR measurements of the thoracic aorta revealed that examinations after bolus testing were significantly superior to examinations without a test bolus (p < 0.001). Signal intensity ratios of the aorta and the pulmonary trunk were significantly higher in examinations with an optimal contrast timing (p < 0.001). Magnetic resonance angiograms of the thoracic aorta with a timing run are significantly superior to non-timed examinations with respect to image quality and SNRs. The administration of 20 ml of Gd-DTPA is sufficient for adult patients.

Adolescent↗

[MR angiography and flow measurement in coronary arteries and coronary bypass grafts].

Better MR image quality of coronary arteries and coronary grafts is the product of increased spatial and temporal resolution. Breathing artifacts could be reduced by implementing breath-holding and navigator techniques. With these developments normal coronary arteries can often be imaged reliably. Several trials have been performed in order to test the reliability of MR angiography to detect coronary artery stenosis. But up to now, sensitivity and specificity have proven to be too low to introduce these techniques in clinical routine. The patency of coronary grafts can be detected reliably using different MR techniques. Coronary flow reserve can be measured using the MR phase contrast technique. This noninvasive approach was tested in diseased coronary arteries and in graft stenoses. A reduced MR coronary flow reserve corresponded to reduced flow reserve measured invasively. Measurement of MR flow reserve in normal and diseased coronary grafts revealed significant differences (3.3 +/- 0.4 vs. 1.3 +/- 0.2).

Blood Flow Velocity↗

[Perfusion MR imaging of the heart with TrueFISP].

OBJECTIVE: Development and test of a saturation-recovery TrueFISP (SR-Trufi) pulse sequence for myocardial perfusion MR imaging (MRI) using improved gradient hardware. MATERIAL AND METHODS: Measurements were performed on a 1.5 T scanner with prototype gradients (50 mT/m, minimum rise time 300 microseconds). T1-weighted first-pass MRI of Gd-DTPA (0.025 mumol/kg) kinetics in the myocardium was performed using an SR-Trufi pulse sequence (TR/TE/alpha = 2.6 ms/1.4 ms/55 degrees) with a saturation preparation of TD = 30 ms before the TrueFISP readout. Measurements were performed in volunteers (n = 4) and in a pig model of chronic ischemia (n = 1). RESULTS: In phantoms, the signal intensity was linear with contrast concentration up to 0.9 mmol/kg Gd-DTPA. MR images obtained with SR-Trufi had a good image quality and high spatial resolution of 2.1 mm x 2.1 mm. Differences of the contrast agent's kinetics between a subendocardial perfusion deficit and neighboring myocardium were well visible on both MR images and signal-time curves derived from the region-of-interest analysis. CONCLUSION: SR-Trufi appears to be an interesting new technique for the assessment of myocardial microcirculation using dedicated cardiovascular MR systems.

Adult↗

[Contrast-enhanced three-dimensional MR angiography of the carotid artery at 1.0 Tesla compared to i.a. DSA: is the method suitable for the diagnosis of carotid stenosis?].

PURPOSE: To evaluate the efficacy of three-dimensional, contrast-enhanced magnetic resonance angiography (CE-MRA) of the carotid artery with a 1.0 T system in comparison to intra-arterial conventional angiography (i.a.CA) for the assessment of carotid artery disease. METHOD: 55 patients with suspected stenosis of the carotid artery were examined with a 3 D-CE gradient-echo sequence on a 1.0 T scanner (TR/TE = 6.2/2.2 ms) and a selective DSA i.a. angiography. Image quality was evaluated by estimating the arterial contrast and venous enhancement. Morphological pathologies were registered for all arteries, stenoses of the internal carotid artery were graded by applying the NASCET criteria. RESULTS: Sensitivity and specificity of MRA in detecting high-grade stenosis (> or = 70%) and occlusion of the extracranial internal carotid artery were 97.7 and 94.0%. Therapeutic relevant misinterpretations were mostly based on overestimating the stenoses. CONCLUSION: The applied CE-MRA technique with a 1.0 T system is suitable for the assessment of carotid artery stenoses. In case of a therapeutically relevant stenosis revealed by MRA, however, verification of the diagnosis by i.a. CA is recommended.

Aged↗

[MRI in chronic epicondylitis humeri radialis using 1.0 T equipment--contrast medium administration necessary?].

PURPOSE: Evaluation of the diagnostic value and confidence of contrast-enhanced MR imaging in patients with lateral epicondylitis in comparison to clinical diagnosis. MATERIAL AND METHODS: 42 consecutive patients with clinically proven chronic lateral epicondylitis and 10 elbow joints of healthy controls have been examined on a 1.0 T MR-unit. Criteria for inclusion in the prospective study were: persistent pain and a failed conservative therapy. The MR protocol included STIR sequence, a native, T2-weighted, fat-suppressed TSE sequence, and a Flash-2-D sequence. Also, fat-suppressed, T1-weighted SE sequences before and after administration of Gd-DTPA contrast media have been recorded. RESULTS: In 39/42 patients the STIR sequence showed an increased SI of the common extensor tendon. Increased MR signal of the lateral collateral ligament combined with a thickening and a partial rupture or a full thickness tear have been observed in 15/42 cases. A bone marrow edema at the lateral epicondilus was noticed in 6 of the studied patients and a joint effusion in 18/42 patients. After administration of contrast media we noticed an average increase of SI by about 150%. However, enhanced MR imaging did not provide additional information. CONCLUSION: In MR imaging of chronic epicondylitis administration of gadolinium-DTPA does not provide additional information.

Adult↗

[Evaluation of left ventricular aneurysms before and after surgery using Cine-MRI].

PURPOSE: To demonstrate the usefulness of cine-MRI for the evaluation of apical left ventricular aneurysms (ALVA) and for prediction of the surgical outcome. MATERIALS AND METHODS: We investigated 28 patients with ALVA, 13 of them additionally after aneurysmectomy at 1.5 T; 15 healthy volunteers served as normal controls. For cine-MRI k-space segmented Fl-2D-GE sequences were used. Analysis comprised the calculation of cardiac volume indices, cardiac function, and percentual myocardial thickening (PMT). For prediction of surgical results we divided left ventricle into an aneurysmatic and a non-aneurysmatic part. The non-aneurysmatic part was assumed as the left ventricle after surgical remodelling. RESULTS: Enddiastolic and endsystolic volume indices (EDVIs and LV-ESVIs) were higher in patients with ALVA (123.7 +/- 30.2 ml/m(2), 94.3 +/- 32.5 ml/m(2), respectively) than in volunteers (79.1 +/- 13.9 ml/m(2), 25.5 +/- 5.1 ml/m(2), respectively) (p < 0.001). Stroke volume index (SVIs), cardiac index (CIs) and ejection fraction (EFs) were significantly lower in patients (30.4 +/- 9.1 vs. 54.2 +/- 0.2 ml/beat/m(2); 2.2 +/- 0.8 vs. 3.9 +/- 0.9 l/min/m(2), 26.0 +/- 9.7 vs. 67.9 +/- 4.5 %, respectively) (p < 0.001). There was a significant decrease of LV-EDVIs and LV-ESVIs (102.8 +/- 30.3 ml/m(2), 66.3 +/- 28.0 ml/m(2), respectively) (p = 0,002, p < 0.001, respectively), no change of SVIs (36.4 +/- 6.0 ml/beat/m(2)) (p > 0.05) and a significant increase of CIs and EFs (3.0 +/- 0.6 l/min/m(2), 37.91 +/- 10.15 %, respectively) (p < 0.001) after surgery. We found a good correlation between the preoperatively calculated (32.6 +/- 10.1 %) and the measured EF after surgery (37.9 +/- 9.8 %) (r = 0.70; p = 0.035). PMT was significantly lower in patients than in volunteers (median 11.9 +/- 10.7 vs. 70.2 +/- 13.9 %; p < 0.001), especially in the aneurysmatic parts of left ventricle (median - 6.8 %; p < 0.001). CONCLUSION: Cine-MRI offers accurate evaluation of ALVA and enables preoperative estimation of left-ventricular volumes after surgery.

Aged↗

[Occult fracture of ossified Achilles tendon without associated rupture of the tendon].

Ossification of the Achilles tendon is the result of a traumatic, hypoxic injury of the tendon. The usually asymptomatic ossification has a clinical importance only in case of a new trauma. We report about a patient with an isolated fracture of the ossification without an accompanying rupture of the Achilles tendon. Because of the radiologically "occult" fracture the diagnosis could only be verified by MRI. With a conservative treatment without resection of the ossification we could reach painless recovery.

Achilles Tendon↗

[Sensitivity of magnetic resonance tomography in detecting meniscus tears].

In order to assure diagnostic accuracy, 172 knee joints were examined prospectively by MRI. After MRI, all knee joints were examined by arthroscopy. Tears of the medial meniscus were found in 102 patients, the lateral meniscus showed a tear in 29 cases. Assuming that arthroscopy represents the golden standard of diagnostic measure concerning the knee joint, it can be stated that false-positive MRI findings on the medial and lateral meniscus were diagnosed in three cases and false-negative MRI findings were diagnosed for two knee joints regarding the medial meniscus and four times regarding the lateral meniscus. For the medial meniscus a sensitivity of 98%, a specificity of 96%, an accuracy of 94%, and the positive and negative value of prediction were calculated at 97% each. Regarding the lateral meniscus, a sensitivity of 85%, a specificity of 98%, an accuracy of 92%, a positive predictive value of 88%, and a negative predictive value of 85% were found. Under the prerequisite that the MRI is carried out correctly and assessed by an experienced radiologist, the accuracy of the MRI for meniscus diagnosis is almost equivalent to the one by arthroscopy. Under these conditions, MRI can be recommended when no safe and sufficient clinical diagnosis can be made. The rate of unnecessary arthroscopies with a pure diagnostic purpose can be lowered significantly by means of MRI.

Adolescent↗