Initial experience with transvenous implantable cardioverter defibrillator lead systems: operative morbidity and mortality.

Introduction of non-thoracotomy lead systems (Medtronic, Inc.) for the implantable cardioverter defibrillator (ICD) has expanded the indications for use of this mode of therapy. Patients previously considered "too ill" to undergo a thoracotomy as well as patients who are at a high risk for developing sudden death but without previous cardiac arrest, are now considered candidates. The initial experience with the non-thoracotomy lead system at our institution was analyzed for morbidity and mortality. Thirty-four patients underwent attempted intravascular lead implantation, with 30 having initial successful implantation (88.2%). There were 23 males; average ejection fraction (EF) was 38.6%. Three patients developed pulmonary edema and low output immediately after the procedure. Three patients developed electromechanical dissociation during defibrillation threshold testing. A prolonged testing time for the non-thoracotomy lead system was noted when compared to the thoracotomy system (57.39 vs 32.30 min; P < 0.0000). There were more intraoperative morbidities with the non-thoracotomy leads than with the thoracotomy system. There were no perioperative deaths. The potential consequences of prolonged anesthesia time and extensive defibrillation threshold testing should be considered when choosing the route of ICD implant, the type of anesthesia, and the intraoperative testing protocol for each patient.

Defibrillators, Implantable

Long-term stability of defibrillation thresholds with intrapericardial defibrillator patches.

From March 1982 to May 1, 1992, 105 consecutive patients underwent initial implant of cardioverter defibrillators (ICD) at our institution. Twenty-nine patients (23 male and 6 female, average ejection fraction 32.24%) with ICD systems implanted via thoracotomy and either intra- or extrapericardial patches, had one or more revisions including 56 generator changes or staged implant procedures, three patch revisions, one patch lead fracture without revision, and one sensing lead revision. The time between pulse generator revisions averaged 19.5 months. Initial defibrillation threshold mean was 12.8 joules (n = 25); at first revision, 14.46 joules (n = 29), (P = NS); by fifth revision, 15.0 joules (n = 2), (P = NS). One patch was noted to be crinkled at 70 months; one patch had migrated by 39 months, and two patch leads had fractured at the costal margin by 69 and 90 months. One patient with marginal defibrillation thresholds had an additional patch placed at revision to an upgraded ICD unit. Once acceptable defibrillation threshold (DFT) is obtained, the long-term intrapericardial DFT remains stable unless a specific problem occurs. As a small, nonstatistically significant increase in DFT may occur, caution must be exercised in patients with marginal DFTs.

Amiodarone

Comparison of left ventricular cryolesions created by liquid nitrogen and nitrous oxide.

OBJECTIVES: This study was designed to compare the cryosurgical lesions produced by liquid nitrogen (-196 degrees C) and nitrous oxide (-76 degrees C). BACKGROUND: Cryosurgical ablation is a useful method of arrhythmia surgery, but information on the dimensions of cardiac lesions produced by modifying cryoprobe temperature is limited. METHODS: We compared the dimensions, volumes and electrophysiologic effects of cryolesions created by a liquid nitrogen cryoprobe (Group I) and a nitrous oxide cryoprobe (Group II) on the left ventricular myocardium in the beating canine heart. Exposure time was compared at 1, 2, 3 and 4 min. In each of 18 dogs, two to four lesions were created on the left ventricle and analyzed: 35 lesions created with use of the nitrous oxide cryoprobe and 30 lesions created with the liquid nitrogen cryoprobe. Lesions were measured at the time of induced death 6 weeks postoperatively and assessed by tissue staining with the Masson trichrome technique. RESULTS: The volumes (mm3) of the cryolesions created by the liquid nitrogen cryoprobe were significantly larger (p < 0.05) than those of lesions created by nitrous oxide: 826 +/- 163 versus 493 +/- 197 at 1 min; 1,101 +/- 327 versus 666 +/- 185 at 2 min; 1,356 +/- 318 versus 787 +/- 258 at 3 min and 1,735 +/- 534 versus 923 +/- 376 at 4 min. CONCLUSIONS: Decreasing the temperature of the cryoprobe by using liquid nitrogen increases the volume of the lesions. Programmed electrical stimulation before and 6 weeks after cryoablation indicated no arrhythmogenicity.

Animals

Clinical evaluation of the safety of repetitive intraoperative defibrillation threshold testing.

One goal of the initial implantation procedure for a cardioverter defibrillator is determination of the configuration and patch location with the lowest defibrillation threshold (DFT). To determine the safety of multiple defibrillation tests, an analysis of the intraoperative defibrillation threshold tests (DFTT) in our patients was performed. In 84 patients, the mean number of DFT trials was 5.27; the mean number of joules received was 275.0. The maximum number of shocks in one implant procedure was 50 for a total of 4,895 joules without complications. Four patients received 30 or more DFT shocks without complication. There were two complications related directly to the DFTT: one patient with severe noninflammatory cardiomyopathy developed electromechanical dissociation and was subsequently resuscitated and survived; the second patient with severe triple vessel coronary artery disease suffered an intraoperative myocardial infarction during testing and eventually died 22 days postoperatively. All patients received an ICD unit; six patients had DFTs of greater than 20 joules. Based on our experience, we followed the clinical status (heart rate, blood pressure, ECG changes, fluid status, total anesthesia time) during the DFTT to determine the extent and duration of our testing protocol. Multiple shocks due to repositioning of the leads in a stable patient should not prohibit extensive testing as adverse consequences do not appear to be cumulative.

Electric Countershock

Prognosis of patients with ventricular tachycardia or fibrillation and a normal electrophysiologic study.

The outcome of 26 patients with sustained ventricular tachycardia (n = 16) or ventricular fibrillation (n = 10) and no inducible ventricular tachycardia (less than or equal to 10 beats) by baseline programmed stimulation was studied. Coronary artery disease was present in 14 patients, dilated cardiomyopathy was seen in seven, valvular heart disease was present in two, and no apparent cardiac abnormalities were found in three. The mean left ventricular ejection fraction was 53 +/- 14%. During the follow-up period of 24 +/- 16 months, actuarial survival rates at 1 and 2 years were 95% and 89% for sudden death and 95% and 83% for total cardiac death, respectively. No patients with a known ejection fraction greater than 30% died suddenly during the follow-up. Noninducibility by programmed stimulation in patients with sustained ventricular tachycardia or fibrillation is associated with a relatively preserved ventricular function. It may predict a low risk of sudden death in patients with preserved ventricular function.

Actuarial Analysis

Sudden death mortality in implantable cardioverter defibrillator patients.

Implantable cardioverter defibrillator (ICD) prevention of sudden cardiac death (SCD) is not absolute and our experience was reviewed to determine the frequency and nature of SCD in this population. The incidence and cause of mortality in 56 consecutive patients, who underwent ICD implantation beginning May 1982 with follow-up through May 19, 1990 were analyzed. Twenty-one patients died, 33% of the mortality was due to SCD, and 52% of deaths may be considered arrhythmic. The cumulative 1, 3, and 5 year SCD survivals were 93%, 89%, and 75%. All seven patients dying of SCD presented initially with SCD, all received previous shocks prior to SCD, and two of the seven patients had devices that were probably inactive at the time of death. We conclude that ICDs reduce but by no means eliminate arrhythmic death, particularly in those at highest risk for SCD. Arrhythmic death remained the most common cause of death in this population.

Arrhythmias, Cardiac

Posterior septal and right free-wall Kent pathways visualized in situ and removed at operation.

This article describes the first posterior septal and first and second right free-wall pathways identified at operation for Wolff-Parkinson-White syndrome and confirmed histologically. All pathways were found in the areas of preexcitation identified by pre and intraoperative mapping. They bridged the atrium and ventricle, and postoperative electrophysiological testing confirmed division of the pathways. Kent bundles may be identified at the time of surgery but they appear to be gossamer structures usually destroyed during surgical manipulation of the coronary sulcus. Visualization of the suspected bypass tract should not alter or limit the extent of surgical dissection.

Biopsy

Electrophysiologic testing in patients with recurrent syncope: are results predicted by prior ambulatory monitoring?

Syncope is a common medical problem which can result from many etiologies, including cardiac dysrhythmias. Because ambulatory monitoring usually fails to capture a syncopal episode, electrophysiologic testing has been used to elucidate dysrhythmic mechanisms in patients with recurrent syncope. To assess whether findings on ambulatory monitoring not obtained during syncope can be used to indicate the results which are found on electrophysiologic testing in patients with recurrent syncope, we reviewed the ambulatory monitoring records of 59 such patients referred for electrophysiologic testing. Although 29 patients had abnormalities on electrophysiologic testing, 13 of which were severe, in only six were the findings suggested by the abnormalities recorded during ambulatory monitoring. Twenty-one patients actually had concordance between electrophysiologic testing and ambulatory monitoring results, but in 15 of the 21 results of both tests were normal. Severe abnormalities were more frequently detected in our patient population by electrophysiologic testing than by ambulatory monitoring, especially if patients had organic heart disease.

Adolescent

Sinus node echoes and concealed concealed conduction: additional sinus node phenomena confirmed in man by direct sinus node electrography.

Direct sinus node electrography has been previously used to assess several aspects of sinus node physiology: sinus node pauses, overdrive suppression, sinoatrial entrance block. This report presents data in which sinus node electrograms confirm two additional physiologic phenomena in man: concealed conduction in the sinoatrial junction and sinus node reentry. These findings verify the presence of previously suspected phenomena by careful deductive analysis of electrocardiographic and electrographic tracings.

Adult