PubMed Health⌕ Search

Biomedical subjects

K Fish

Publications and source records attributed to K Fish.

7 recordsLinked to original sources

Testing internal consistency and construct validity during evaluation of performance in a patient simulator.

UNLABELLED: The primary goal of this study was to test the items in a rating system developed to evaluate anesthesiologists' performance in a simulated patient environment. A secondary goal was to determine whether the test scores could discriminate between resident and staff anesthesiologists. Two 5-item clinical scenarios included patient evaluation and induction and maintenance of anesthesia. Rating scales were no response to the problem (score = 0), compensating intervention (score = 1), and corrective treatment (score = 2). Internal consistency was estimated using Cronbach's coefficient alpha. Scores between groups were compared using the Cochran-Mantel-Haenszel test. Subjects consisted of 8 anesthesiology residents and 17 university clinical faculty. The Cronbach's coefficient alpha was 0.27 for Scenario A and 0.28 for Scenario B. Two items in each scenario markedly decreased internal consistency. When these four items were eliminated, Cronbach's coefficient alpha for the remaining six items was 0.66. Faculty anesthesiologists scored higher than residents on all six items (P < 0.001). A patient simulator-based evaluation process with acceptable reliability was developed. IMPLICATIONS: The reliability of anesthesia clinical performance in a patient simulation environment was assessed in this study. Of 10 items, 4 were poor in the evaluation process. When these items were removed, the reliability of the instrument improved to a level consistent with other studies. Because faculty scored higher than resident anesthesiologists, the instrument also showed discriminant validity.

Adult↗

Testing the raters: inter-rater reliability of standardized anaesthesia simulator performance.

PURPOSE: Assessment of physician performance has been a subjective process. An anaesthesia simulator could be used for a more structured and standardized evaluation but its reliability for this purpose is not known. We sought to determine if observers witnessing the same event in an anaesthesia simulator would agree on their rating of anaesthetist performance. METHODS: The study had the approval of the research ethics board. Two one-hour clinical scenarios were developed, each containing five anaesthetic problems. For each problem, a rating scale defined the appropriate score (no response to the situation: score = 0; compensating intervention defined as physiological correction: score = 1; corrective treatment: defined as definitive therapy score = 2). Video tape recordings, for assessment of inter-rater reliability, were generated through role-playing with recording of the two scenarios three times each resulting in a total of 30 events to be evaluated. Two clinical anaesthetists, uninvolved in the development of the study and the clinical scenarios, reviewed and scored each of the 30 problems independently. The scores produced by the two observers were compared using the kappa statistic of agreement. RESULTS: The raters were in complete agreement on 29 of the 30 items. There was excellent inter-rater reliability (= 0.96, P < 0.001). CONCLUSIONS: The use of videotapes allowed the scenarios to be scored by reproducing the same event for each observer. There was excellent inter-rater agreement within the confines of the study. Rating of video recordings of anaesthetist performance in a simulation setting can be used for scoring of performance. The validity of the scenarios and the scoring system for assessing clinician performance have yet to be determined.

Anesthesia, General↗

Isolation and characterization of a low-abundance splice variant from the human cytomegalovirus major immediate-early gene region.

The major immediate-early (IE) gene region of human cytomegalovirus (HCMV) encodes several proteins as a result of differential RNA splicing events. By expression vector cloning of HCMV IE mRNA, we isolated and characterized a cDNA for a novel splice variant from the major IE gene region. The RNA product is a derivative of the IE55 mRNA and contains an additional splice from nucleotides 170,635 to 170,307 in the IE2 gene region (UL122), resulting in a 1.4-kb mRNA. The predicted open reading frame codes for a 164-amino-acid protein with a calculated molecular mass of 18 kDa (IE18). Mung bean nuclease analysis and PCR were used to characterize expression of IE18 mRNA in HCMV-infected cells. While the 1.4-kb mRNA was detected in infected human fibroblasts in the presence of a protein synthesis inhibitor, it was not detectable during a normal infection. However, the 1.4-kb mRNA was readily detected in infected human monocyte-derived macrophages at IE times. These results suggest that the novel IE18 mRNA exhibits cell type-specific expression indicating differential regulation of the major IE gene region in different permissive cell types.

Amino Acid Sequence↗

An isoform variant of the cytomegalovirus immediate-early auto repressor functions as a transcriptional activator.

The major immediate-early promoter (MIEP) of human cytomegalovirus directs the expression of several differentially spliced and polyadenylated mRNAs. These mRNAs encode nuclear phosphorproteins (IE55, IE72, and IE86), which consist of common and unique amino acid sequences. To date, very little is known of the functional role of the 55-kDa (IE55) protein. Here we present evidence that the IE55 protein is a positive activator of the MIEP. In human fibroblast cells IE55 protein activated the MIEP between 10- and 30-fold. Fusion of IE55 to the GAL4 DNA binding domain resulted in a chimeric protein capable of trans-activating a reporter with GAL4 recognition sequences. These results strongly suggest that IE55 is a bona fide transcriptional activator protein. In addition, the IE55 protein was found not to act synergistically with the IE72 activator protein. The IE55 protein shares the same amino acid sequence as IE86 except for a 154-amino-acid deletion at the C-terminal end of the protein. These proteins were functionally antagonistic; IE55 relieved repression by IE86 and, conversely, IE86 negated IE55 activation. Mutagenesis of the MIEP revealed that the target sequence for activation by IE55 is different from the IE86 autorepressive response element. These experiments suggest that the mechanism of action of the IE55 and IE86 isoforms is distinct. Moreover, from these results it is apparent that the interplay of these factors might be critical in determining the level of HCMV replication in the host.

Base Sequence↗

A cluster of severe postoperative bleeding following open heart surgery.

OBJECTIVE: To investigate a cluster of postoperative bleeding following open heart surgery. DESIGN: A cohort and case/control study. SETTING: Palo Alto Veterans Administration Medical Center, Palo Alto, California. PARTICIPANTS: Six (21.4%) of 28 patients undergoing open heart surgery who developed severe, nonsurgical, postoperative bleeding from July 1 through August 30, 1988 (outbreak period). All case-patients had chest tube drainage of greater than or equal to 1000 ml within 4 hours of surgery but did not have identifiable bleeding vessel(s) on exploration. RESULTS: Upon comparison of the pre-outbreak (January 1986 through June 1988) and the outbreak period, a significant increase was found in the incidence of postoperative nonsurgical bleeding (5/440 versus 6/28, p = .0006), but not of postoperative surgical bleeding (8/440 versus 0/28, p = 1.0). Of all patients undergoing open heart surgery during the outbreak period, case patients were found to be older (67.8 versus 60.6, p = .02) and to have received a larger volume of hetastarch (HES), a synthetic colloidal plasma-volume expander (mean = 19.4 ml/kg versus 14.1 ml/kg, p = .02). CONCLUSIONS: We conclude that the use of large volumes of HES during surgery in the elderly open heart surgery patient may increase the risk for severe, nonsurgical postoperative bleeding, probably caused by alterations of the coagulation system. As the incidence of open heart surgery increases among the elderly, surgeons and anesthesiologists should be alert to possible adverse reactions from exposures not associated with adverse reactions in younger patients.

Aged↗

Renal function in Fischer 344 rats with chronic renal impairment after administration of enflurane and gentamicin.

To assess the potential for producing nephrotoxicity in rats with abnormal renal function, the renal effects of enflurane or halothane anesthesia, 1 MAC for two hours, were examined in six groups of six Fischer 344 rats each with surgically induced chronic renal impairment. As an additional predisposing factor, gentamicin, 5 mg/kg/day, was administered for one week before and for one week after anesthesia to three of the groups, one anesthetized with enflurane, one anesthetized with halothane, and one unanesthetized. No significant change in renal function could be attributed to either anesthetic agent. Serum inorganic fluoride levels four hours and 24 hours after enflurane anesthesia were similar in the gentamicin-treated and the non-gentamicin-treated groups. Clinically small but statistically significant increases in serum creatinine concentration and urinary flow occurred in all three gentamicin-treated groups during the period of treatment. Anesthesia with either enflurane or halothane in rats with chronic renal impairment treated with gentamicin did not result in additional renal damage.

Acute Kidney Injury↗