PubMed Health⌕ Search

Biomedical subjects

K Fluri

Publications and source records attributed to K Fluri.

3 recordsLinked to original sources

Method for confirmation of synthetic corticosteroids in doping urine samples by liquid chromatography-electrospray ionisation mass spectrometry.

In this study, we report on the development of a method to confirm simultaneously nine of the most commonly abused synthetic corticosteroids in urine based on liquid chromatography-electrospray ionisation mass spectrometry. A considerable simplified sample preparation procedure, including liquid-liquid phase extraction with Extrelut-NT3 columns, provided both excellent sample purification and high overall recoveries. Complete HPLC separations were obtained on a reversed-phase column with 1 mM ammonium acetate-acetonitrile (60:40, v/v) as mobile phase. Mass spectral acquisition was done in the negative ion, and selected ion monitoring modes to identify the drugs with at least three characteristic ions. Detection limits were determined at < or =1 ng/ml and the confirmation limits at 1 to 5 ng/ml.

Adrenal Cortex Hormones↗

Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays.

This article presents the first example of a microfluidic chip for heterogeneous bioassays using a locally immobilized biospecific layer and operated electrokinetically. The reaction chamber has picoliter dimensions and is integrated into a network of microchannels etched in glass. The high affinity of protein A (PA) for rabbit immunoglobulin G (rIgG) was exploited for chip testing, with PA being immobilized on microchannel walls and fluorescently labeled (Cy5) rIgG serving as sample. It was possible to operate the chip in an immunoaffinity chromatographic manner, using electrokinetically pumped solutions. Concentration of antibody from dilute solution onto the solid phase was demonstrated, with signal gains of approximately 30 possible. A dose-response curve for Cy5-rIgG was obtained for concentrations down to 50 nM, for an incubation time of 200 s. The flexibility of chip layout was demonstrated for competitive immunoassay of rIgG, using both a combined sample/tracer incubation and sequential addition of these solutions. With assay times generally below 5 min for this unoptimized device, the microfluidic approach described shows great potential for many high-throughput screening applications.

Carbocyanines↗

A two-electrode configuration for simplified amperometric detection in a microfabricated electrophoretic separation device.

The simplified amperometric detection scheme demonstrated is based on the amperometric working and electrophoretic ground electrodes only. The latter serves as counter and pseudo-reference as well. It is shown via the successful determination of neurotransmitters, ascorbic acid and phenols on gold or platinum working electrodes that this approach is feasible for detection on a channel based electrophoretic separation device. Also presented is the detection of carbohydrates and amino acids with copper electrodes. The results were found to be similar to those obtained with conventional capillary systems with amperometric detection, albeit at much reduced analysis times.

Journal Article↗