PubMed HealthSearch

Biomedical subjects

K Foreman

Publications and source records attributed to K Foreman.

3 recordsLinked to original sources

Effect of dialyzer reprocessing with Renalin on serum beta-2-microglobulin and complement activation in hemodialysis patients.

The peracetic acid-based sterilant Renalin is increasingly being used for reprocessing hemodialyzers. In order to evaluate the effects of reprocessing on beta 2-microglobulin (beta 2M) kinetics and complement activation in chronic hemodialysis patients, we compared 4 dialyzer membranes on 1st, 2nd and 4th use of the membrane. Dialysis with new cuprammonium rayon dialyzers (0.8 m2) for 4 h resulted in a nonsignificant increase in serum beta 2M concentrations of 10.7% (corrected for changes in extracellular volume) and significant generation of the complement component C3a des Arg. On reuse, minimal changes in serum beta 2M levels were noted and complement activation was absent. Dialysis with new cellulose acetate (CA, 1.5 m2), polyacrylonitrile (AN69 HF, 1.6 m2) or polymethylmethacrylate (PMMA, 1.6 m2) membranes resulted in significant decreases in serum beta 2M levels (19.5, 31.7 and 50.8%, respectively). Reprocessing had negligible effects on the removal of beta 2M by CA and AN69, but by the 4th use halved the effectiveness of PMMA. Reprocessing reduced the significant generation of C3a des Arg observed with new CA and PMMA membranes. We conclude that, except for PMMA, Renalin reprocessing has minor effects on the ability of the membranes to remove beta 2M and improves the biocompatibility of all membranes studied.

Acetic Acid

Dialyser reprocessing with Renalin.

We evaluated the dialyser reprocessing agent Renalin in a 6-month prospective study of 2,759 dialyses on 59 patients. Dialysers were withdrawn after a maximum of 6 uses, and the average number of uses achieved was 4.5 Dialyser survival varied with the type of dialyser but was unaffected by the dialysate base. In vivo clearances of urea, creatinine and phosphate were not altered by reuse, but there was a small decrease in ultrafiltration characteristics of used dialysers. No clinically significant adverse event was attributed to reuse. Blood pressure was better preserved with used dialysers, and patients experienced significantly fewer intradialytic symptoms. Savings of over +A 25,000 were achieved during the study.

Acetates

Comparison of six different regimens for the control of atrophic rhinitis in swine.

Effectiveness of six different programs of atrophic rhinitis (AR) control was evaluated under field conditions. Efficacy of treatments was recognized on the basis of--comparative evaluation of the average daily gain (ADG), morphometric examination of turbinate bones and computer conchal morphometry (TPR). Usefulness of the evaluated regimes differed significantly. TPR appeared to be the most objective method for AR evaluation. Correlation between severity of turbinate atrophy and ADG was only partial.

Animals