PubMed Health⌕ Search

Biomedical subjects

K François

Publications and source records attributed to K François.

At least 19 recordsLinked to original sources

Neurocognitive consequences of surgically corrected congenital heart defects: A review.

With advances in surgical procedures, neuropsychological assessment after congenital heart defects and pre, peri- and/or postoperative predictors of adverse outcome has become an important focus in research. We aim to summarize neuropsychological sequelae associated with different types of congenital heart defects, critically review the methodology used in more than 20 empirical studies that were retrieved from biomedical electronic search engines, and identify possible directions for future research. Despite the lack of adequate control groups and long-term studies, there seem to be some cognitive deficits. The largest group of children with isolated congenital heart defects present with normal intellectual capacities. However, they tend to show language deficits and motor dysfunction. Although performances on memory tasks are good, unambiguous conclusions concerning their attentional and executive functioning are still lacking. Serious behavioral problems are not an issue. In addition to a detailed description of the (neuro) psychological consequences of pediatric cardiac surgery, an overview of the predictors of the cognitive defects is provided.

Brain Damage, Chronic↗

Evaluation of a challenge testing protocol to assess the stability of ready-to-eat cooked meat products against growth of Listeria monocytogenes.

Challenge testing of ready-to-eat (RTE) foods with Listeria monocytogenes is recommended to assess the potential for growth. The present study was undertaken to evaluate a protocol for challenge testing applied to RTE cooked meat products. In order to choose L. monocytogenes strains with a representative behaviour, initially, the variability of the response of multiple L. monocytogenes strains of human and food origin to different stress and growth conditions was established. The strains were not inhibited in their growth at moderate acid pH (5.25) and the four strains tested in particular showed a similar acid-adaptive response. Growth of the various strains under four different combined stress conditions indicated that no L. monocytogenes strain had consistently significant longer or shorter lag phase or higher or lower maximum specific growth rates. The effect of choice of strain and history (pre-incubation temperature 7 or 30 degrees C) on growth of L. monocytogenes under optimum conditions (Brain Heart Infusion, BHI) and modified BHI simulating conditions of cooked ham and paté was studied. In general, all four L. monocytogenes strains behaved similarly. In BHI, no difference in lag phase was observed for the cold-adapted and standard inoculum, whereas in BHI adjusted to ham and pâté conditions, a ca. 40-h reduction of the lag phase was noted for the cold-adapted inoculum. Subsequently, microbial challenge testing of L. monocytogenes in modified atmosphere packaged sliced cooked ham and paté was performed. A mixed inoculum of four L. monocytogenes strains and an inoculum level of ca. 1-10 cfu/g was used. On vacuum packed sliced cooked ham, the concentration of 100 cfu/g, the safety limit considered as low risk for causing listeriosis, was exceeded after 5 days whereas ca. 10(5) cfu/g were obtained after 14 days when also LAB spoilers reached unacceptable numbers (ca. 10(7) cfu/g) whether standard or cold-adapted inoculum was used. The concentration of sodium lactate determined the opportunities for growth of L. monocytogenes in pâté. If growth of L. monocytogenes in pâté was noticed, the threshold of 100 cfu/ml was crossed earlier for the cold-adapted inoculum compared to the standard inoculum.

Adaptation, Physiological↗

An experimental model of coronary anastomosis without suturing.

OBJECTIVE: The aim of the study is to explore the feasibility and mid-term patency of an easier anastomotic technique for Minimally Invasive Direct Coronary Bypass Grafting (MIDCAB). METHODS: Eight mongrel dogs (+/-15 kg) underwent direct anastomosis between the left internal thoracic artery (LITA) and the left anterior descending coronary artery (LAD) via inferior sternotomy on the beating heart. After positioning the graft, the distal part of the LAD was opened to allow retrograde filling of the LITA-graft. The anastomosis was secured by the use of biological glue (BioGlue, Cryolife, Marietta, GA, USA). No intravascular suture material was used. Ischemic time averaged 6 min. The proximal LAD was occluded upstream the arteriotomy. All survivors were angiographically controlled for patency after 6-8 weeks. Consequently, four dogs were sacrificed after 6 weeks and the remaining after 3 months for anatomo-pathological and histological examination by light and electron microscopy of the anastomotic site. RESULTS: All procedures were successful except for one animal that died of uncontrollable bleeding at the anastomotic site. Another sustained post-operative transmural anterior myocardial infarction due to a late graft occlusion. All angiographically controlled grafts were patent with two vascular strings near the anastomotic site. Histology showed early macrophage infiltration into the glue. At post-mortem examination, new endothelialization was noticed in 80% of the cases. However, ultrastructural examination detected marked differences in endothelial fibroblastic lining compared to normal histology. CONCLUSIONS: Good mid-term permeability of the LITA grafts was observed in this new anastomotic technique for MIDCAB in the canine model. Although neo-endothelialization was present in most cases, ultrastructural differences were noticed after 3 months in the neo-intima compared to normal.

Anastomosis, Surgical↗

Tissue factor as the main activator of the coagulation system during cardiopulmonary bypass.

OBJECTIVE: This study investigates the influence of foreign material and blood aspirated from nonvascular structures on activation of coagulation, hemolysis, and blood loss. METHODS: The series comprises 3 randomized groups (groups C, S, and S+P) of 10 patients undergoing routine coronary artery bypass grafting with cardiopulmonary bypass. In group C, the control group, all aspirated blood was returned into the circulation. In group S suction blood was discarded, whereas group S+P was identical to group S, with surfaces coated with phosphorylcholine. Plasma concentrations of beta-thromboglobulin, thrombin generation, haptoglobin, and free hemoglobin, as well as blood loss, were measured. RESULTS: A steady increase in free plasma hemoglobin, as well as an increased generation of thrombin, was noticed in group C. Moreover, a close correlation (r = 0.916) between the generation of thrombin and its inhibition (thrombin-antithrombin complexes) was observed. Platelets were clearly activated in group C and, to a lesser extent, in group S. In contrast, platelet activation in group S+P was negligible, resulting in a 30% decrease in blood loss (P =.05). CONCLUSIONS: Aspirated blood contaminated by tissue contact is the most important activator of the coagulation system and the principal cause of hemolysis during cardiopulmonary bypass. Contact with a foreign surface is not a main variable in the procoagulant effect of bypass. Mimicking the outer cell membrane structure resulted in decreased platelet activation and decreased blood loss.

Aged↗

Phosphorylcholine coating offers natural platelet preservation during cardiopulmonary bypass.

Return of blood activated by tissue factor is the main culprit for triggering the coagulation cascade. When this activated blood is diverted from the cardiopulmonary bypass (CPB) circuit, it becomes possible to evaluate the effect of surface treatment on platelet and complement activation. Twenty adult patients undergoing elective coronary artery bypass grafting (CABG) were randomly assigned either to a control group (n=10) or to a group in which the CPB circuit was completely coated with phosphorylcholine (n=10). Plasma concentrations of platelet factor 4 (PF4), beta-thromboglobulin (betaTG), C3, C3d, C4, TCC, thrombin generation, haptoglobin and free haemoglobin, as well as blood loss, were measured. No significant differences between the two groups were found for haemolysis and thrombin generation. The mean total release of PF4 and betaTG during CPB was 9338+/-17303 IU/ml/CPB and 3790+/-4104 IU/ml/CPB in the coated group versus 22192+/-13931 IU/ml/CPB (p=0.011) and 8040+/-3986 IU/ml/CPB (p=0.005) in the control group. Blood loss was 30% less in the coated group compared to the control group. Phosphorylcholine coating appears to have a favourable effect on blood platelets, which is most obvious after studying the changes during CPB. Clinically, this effect resulted in a 30% reduction in blood loss.

Aged↗

Spot 14 protein interacts and co-operates with chicken ovalbumin upstream promoter-transcription factor 1 in the transcription of the L-type pyruvate kinase gene through a specificity protein 1 (Sp1) binding site.

In hepatocytes, the amount of the Spot 14 (S14) protein is closely related to the full expression of enzymes involved in the glycolytic and lipogenic pathways. In the present study we address the role played by this protein in the control of transcription of the L-type pyruvate kinase (L-PK) gene in primary hepatocytes. We show that human S14, which by itself does not bind to the L-PK promoter, physically interacts with the human chicken ovalbumin upstream promoter-transcription factor 1 (COUP-TF1) and induces the switch of this factor from a repressor to an activator. However, the enhancing activity of S14 and COUP-TF1 depends on the presence of a proximal GC-rich box (the L0 element) that specifically binds nuclear proteins from the livers of rats fed a glucose-rich diet. Moreover, the L0 element, which strongly binds dephosphorylated specificity protein 1 (Sp1), loses all affinity when this factor is phosphorylated by cAMP-dependent protein kinase. Mutations that affect binding of Sp1 and nuclear proteins to the L0 box also decrease basal transcription and impair glucose responsiveness of the promoter. These results therefore shed light on the mechanism by which the S14 protein, whose concentration rapidly rises after glucose intake, contributes to the full activity of the L-PK promoter.

Animals↗

Redo mitral surgery using the Estech endoclamp.

BACKGROUND: Redo-CABG surgery remains extremely hazardous in the presence of open bypass grafts. In our patients with mitral valve pathology with open and well-functioning bypass grafts, we explored alternative approaches in order to avoid damage to the grafts by extensive dissection and direct clamping of the ascending aorta. The "Estech procedure," which uses the Estech remote access perfusion (RAP) endoclamp catheter (Estech Inc., Danville, CA), was selected for these patients. METHODS: From January 1998 to January 2000, 10 patients underwent an Estech procedure for redo mitral surgery. All patients had previous cardiac operations such as coronary artery bypass grafting (CABG) and/or mitral valve procedures. The Estech procedure consisted of an anterior left thoracotomy and peripheral cannulation at femoral site using the Estech endovascular balloon technique. The series was comprised of seven mitral valve replacements, two valve reconstructions, and one closure of a paravalvular leak. One procedure had to be converted to a standard re-sternotomy due to extreme arteriosclerosis of the descending aorta with plaque dislocation at the time of catheter insertion. However, no damage was inflicted to the open bypass grafts. RESULTS: The follow-up period ranged from six to 30 months and was 100% complete. We encountered one hospital death in our group, which was due to a late post-operative intestinal infarction and multiple organ failure (MOF), and was not procedure related. As expected, morbidity was high in this compromised cohort, but no late death has occurred prior to submission of this article. All survivors progressed to an acceptable NYHA functional class. CONCLUSION: The excellent results in this complex patient group inspired us to use the Estech procedure as a standard approach for redo mitral surgery.

Coronary Artery Bypass↗

Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface.

OBJECTIVE: The aim of this study is to evaluate the use of a new coating, mimicking the outer cell membrane, in paediatric cardiac surgery. METHODS: Two groups of ten patients with a body weight below 8 kg, undergoing elective cardiac operations for different congenital anomalies, were prospectively enrolled in this study. In one group the whole extracorporeal circuit, including the cannulas, was coated with phosphorylcholine (PC). In the second group the same circuit was used without coating. Platelet activation (thromboxane B2 (TXB2), beta-thromboglobulin (betaTG)), activation of the coagulation system (F1+2), leukocyte activation (CD11b/CD18) and terminal complement activation (TCC) were analyzed pre-cardiopulmonary bypass (CPB), at 15, 60 min of CPB, at the end of CPB, 20 min post CPB and at postoperative day 1 and 6. RESULTS: No statistical differences were found for F1+2 and CD11b/CD18. After onset of CPB mean levels of TCC remained stable in the PC group whereas an increase was observed in the control group. During CPB betaTG values in both groups increased to a maximum at the end of CPB. Within groups the increase in betaTG levels during CPB was statistically significant (P<0.05) from baseline in the control group starting from 60 min of CPB whereas no statistical difference was observed in the PC group. After the start of CPB TXB2 mean levels increased to 405+/-249 pg/ml in the PC group vs. 535+/-224 pg/ml in the control group. After this initial increase there was a small decline in the PC group with further increase. This was in contrast to the control group were TXB2 levels further increased up to a mean of 718+/-333 pg/ml at the end of CPB (P=0.016). CONCLUSIONS: Phosphorylcholine coating had a favourable effect on blood platelets, which is most obvious after studying the changes during cardiopulmonary bypass. A steady increase of TXB2 and betaTG was observed in the control group, whereas plateau formation was observed in the phosphorylcholine group. Clinically, this effect may contribute to reduced blood loss and less thromboembolic complications. Complement activation is lower in the coated group.

Blood Coagulation↗

Stentless or stented aortic valve implants in elderly patients?

OBJECTIVE: To assess differences in indication and mid-term results between stentless and stented procedures in elderly patients, we followed aortic valve patients over a period of 5 years. METHODS: In a consecutive series of 154 elderly aortic patients in regular sinus rhythm from 1992 to 1997, we inserted 103 stentless (Toronto SPVTM, St Jude Medical Inc., St Paul, Minneapolis, MN) and 51 stented (Carpentier-Edwards supra annular porcine, Baxter Inc., Irvine, CA) bioprostheses in the aortic position. RESULTS: All 154 patients seemed preoperatively eligible for a stentless procedure. Mean age was 74.8 years (range 67-86 years) with a majority of female patients. The surgeon's (in)experience, major dilatation or calcifications of the ascending aorta and aberrant coronary anatomy were the most common reasons for drawback from the stentless procedure (51/154 patients). Aortic clamp time was significantly higher in the stentless vs. stented group (70 vs. 57 min, P < 0.0001). The large average 25.3 mm size of the stentless prostheses (vs. 23.7 mm stented) stands in full contrast with the low mean body surface area of 1.68 m2 (vs. 1.70 m2) of the patients. We encountered. respectively. 5 and 2 hospital-deaths (P = n.s.). The follow-up period ranged from 6 to 66 months and was 97% complete, yielding, respectively, 302 and 139 patient-years. Survival (Kaplan-Meier method) was statistically higher in favor of the stentless procedures (log rank: P = 0.03). All survivors progressed markedly to a mean postoperative NYHA class 1.3 respectively, 1.4 (vs. preop. 3.3 and 3.2). Echocardiographic transvalvular gradients compared favorable for the stentless group in the small under 25 mm valves (P = 0.02 for 23 mm sized valves between groups) with improved left ventricular function and a significant decrease of left ventricular end diastolic diameter (LVEDD 48.0 vs. 56.5 mm) at 1 year follow-up. Cusp calcifications on control echocardiography were detected earlier (beyond 3 years) in the stented group, without signs of early significant regurgitation or dysfunction in both groups, except for one patient necessitating re-operation. CONCLUSION: Although the implantation technique is much more demanding for stentless procedures, reflected by a longer aortic clamp-time, and remains impossible in some cases, elderly, small sized patients take full benefit of their large, non-obstructive prostheses.

Aged↗

Feasibility of a pumpless extracorporeal respiratory assist device.

BACKGROUND: Our study evaluated the efficacy and feasibility of a pumpless respiratory assist device and determined its capacity for carbon dioxide removal. METHODS: In five adult pigs the left femoral vein and artery were cannulated with a 20F cannula and connected to a low-pressure hollow-fiber artificial lung. After we had obtained baseline values of mean arterial pressure, cardiac output, and blood flow across the artificial lung, the mean arterial pressure was reduced 20% and 40% relative to baseline; in a second phase, it was raised 20% and 40. Cardiac output and artificial lung flow were simultaneously recorded. We determined the carbon dioxide removal capacity of the artificial lung by gradually increasing the arterial partial carbon dioxide tension of the animal. RESULTS: An increase of 10 mm Hg in mean arterial pressure resulted in an increase of flow of 0.14 L/min. The mean pressure drop across the artificial lung was measured at 17 +/- 9 mm Hg. The shunt flow over the artificial lung varied between 14 and 25% of the cardiac output of the animal. Depending on inlet conditions, carbon dioxide removal by the artificial lung was between 62 +/- 22 mL/L/min and 104 +/- 25 mL/L/min. CONCLUSIONS: A pumpless respiratory assist device can remove a significant proportion of the metabolic carbon dioxide production. However, adequate mean arterial pressure is mandatory to maintain sufficient flow across the device. The technique seems attractive because of its simplicity and can be used in acute lung injury in conjunction of apneic oxygenation for prolonged respiratory support.

Airway Resistance↗

In vivo evaluation of a phosphorylcholine coated cardiopulmonary bypass circuit.

A complete phosphorylcholine coated cardiopulmonary bypass circuit, including the Dideco D901 oxygenator, was tested for gas transfer, blood path resistance, and biocompatibility in a standardized setting. Blood compatibility was tested by measuring complement and platelet activation. Three dogs (mean body weight 28 +/- 3 kg) were placed on cardiopulmonary bypass at a flow rate of 600 mL/min during 6 hours. The animals were weaned from cardiopulmonary bypass and sacrificed electively after 7 days. Oxygen and carbon dioxide transfer were 26.6 +/- 2.4 mL/min and 33.0 +/- 1.9 mL/min, respectively. Mean pressure drop across the oxygenator was 52.6 +/- 0.2 mmHg. The respective baseline values for thromboxane B2, prostaglandin E2 and platelet factor 4 were 1817 +/- 283 pg/mL, 12783 +/- 2109 pg/mL, and 0.35 +/- 0.08 IU/mL. Thromboxane B2 and prostaglandin E2 increased slightly to 2881 +/- 868 pg/mL and 18083 +/- 3144 pg/mL at 30 minutes of bypass, whereas platelet factor 4 values remained stable curing the procedure. Concentrations of complement split products C5a were only mildly increased. After use scanning electron microscopy was performed on the inner housing, heat exchanger, and outer surface of the hollow fibers. No thrombi nor organized cellular deposits were found on any of the components. Phosphorylcholine coating of CPB seems to be very promising regarding platelet activation and complement activation.

Animals↗

Analysis of the P wave with signal averaging to assess the risk of atrial fibrillation after coronary artery bypass surgery.

P wave signal averaging was performed in 91 consecutive patients undergoing coronary artery bypass grafting to detect patients at risk of postoperative atrial fibrillation (AF). Sixteen patients (17.5%) developed AF after surgery. The P wave duration on the signal-averaged electrocardiogram (ECG) and on surface ECG was prolonged in AF patients compared to others (respectively 141 +/- 12 vs. 132 +/- 12 ms and 124 +/- 9 vs. 113 +/- 9 ms). The root mean square voltages (RMS) of the total P wave were not different between the two groups; the RMS of the late portion of the P wave (late RMS) was significantly higher (0.25 +/- 0.15 vs. 0.17 +/- 0.10 microV) and the RMS of the first 110 ms of the P wave (early RMS) significantly lower (0.88 +/- 0.28 vs. 1.09 +/- 0.33 microV) in AF. The late/ early RMS ratio was different (0.29 +/- 0.16 vs. 0.17 +/- 0.11). In a multivariate analysis only age and the late/early RMS ratio were predictive for AF.

Adult↗

Clinical experience with the first 100 ATS heart valve implants.

Between May 1992 and March 1994, 100 consecutive patients had 119 new ATS mechanical bileaflet valves inserted (61 aortic, 50 mitral, eight tricuspid). The mean age of the patients was 63.7 (range 13-82) years. The follow-up period ranged from 5 to 27 months and was complete in all cases. Before surgery, 53 aortic valve patients were in New York Heart Association functional class III or higher. This improved to a mean of 1.3 postoperatively, all patients being in classes I or II. One patient died in hospital, and another 3 months after implantation (actuarial survival rate 98%). One patient had an embolic event 9 days after an aortic valve reoperation which caused a parietal infarction. One tricuspid valve blocked in the open position 6 weeks after implantation as a result of inadequate anticoagulation and was successfully unblocked after 2 days of intensive thrombolytic therapy. Patients were treated by mild anticoagulation without developing bleeding complications. Echocardiographic, transoesophageal and transthoracic valvular gradients compared favourably with the gradients reported in other mechanical valves (including small aortic valves). The haemodynamics were excellent without evidence of significant regurgitation. This was confirmed by an in vitro hydrodynamic evaluation of the valve using a pulse duplicator system. The valve closure caused little noise and was as a result well tolerated.

Adolescent↗

Low extracorporeal priming volumes for infants: a benefit?

An extracorporeal circuit consisting of an oxygenator especially designed for neonatal use and appropriately sized tubing, with an average total priming volume of 205 ml, was used on 80 infants undergoing cardiac surgery for congenital heart-disease. The priming volume and foreign surface area of the circuit were determined. The influence of low priming volumes on the use of blood products and the management of cardiopulmonary bypass was studied. No whole blood or platelets were used in this study. The mean volume of packed red blood cells used over the hospital stay was 202 +/- 67 ml. The mean volume of fresh frozen plasma (FFP) used until the second postoperative day was 62 +/- 72 ml. The mean total blood loss until the second postoperative day was 15.8 +/- 9.2 ml/kg. The priming volume of the extracorporeal circuit was 62% lower than values commonly reported in the literature. The low priming volume had a strong influence on the use of platelets and FFP and to a lesser extent on the use of packed red blood cells.

Cardiac Surgical Procedures↗

Toronto stentless aortic valve replacement in elderly patients.

From July 1992 to October 1994, we inserted new Toronto SPV stentless aortic heterografts (SJM Med. Inc., St Paul, Minneapolis, USA) in 40 of a series of 50 consecutive patients older than 70 years. The mean age was 75.7 years (range 70 - 86 years). All, except 4 patients, were pre-operatively in NYHA functional class III or higher. The aortic clamp time was significantly higher in the stentless groups (75 v. 53 minutes, P < 0.001). The average 25.5 mm size of the implanted valves stands in stark contract to the low body surface area (1.69 m2) of this patient groups. The surgeon's (in)experience was the major reason for the drawbacks (5/50) associated with a stentless procedures. The follow-up period ranged from 2 to 27 months and was complete in 100% of cases. We encountered 1 hospital death and no late deaths (97.5% actuarial survival). The mean NYHA class at follow-up was 1.5, and without exception patients were in class I or II. We noted one transient ischaemic attack immediately postoperatively and another later incident in a patient with a previous severe vascular history. With a low-intensity anticoagulation regiment for the first 3 months, there were two incidents of haemorrhaging necessitating premature anticoagulation withdrawal. Echocardiographic transthoracic valvular gradients compared favourably with the reported gradients of other biological valves, especially the smaller ones the significantly better haemodynamics were noted in most cases 6 months after implantation. Comparison of data with stented valves implanted during the same period indicates that the average size of the stentless valves was significantly higher (22.3 v. 25.5 mm, P < 0.001) in an equivalent population.

Aged↗

Tricuspid valve replacement: postoperative and long-term results.

A series of 146 consecutive patients who underwent tricuspid valve replacement at the University Brugmann Hospital between 1967 and 1987 was reviewed. Mean age at operation was 51.4 years (+/- 12.1 years). Different types of prostheses were implanted including porcine and bovine pericardial bioprostheses and older and bileaflet mechanical valves. Most patients were severely disabled by their cardiac disease before operation, with 30.1% in New York Heart Association functional class III and 69.9% in class IV. Operative mortality and hospital mortality rates (30 days) were high (16.4%). Incremental risk factors for hospital death included icterus (p < 0.005), preoperative hepatomegaly (p = 0.012), and New York Heart Association functional class IV (p = 0.013). Multivariate analysis only selected preoperative icterus (p < 0.01) as being independently significantly related to hospital mortality. The hospital survivors were followed up for a median of 94 months. A complete follow-up was available for all patients except two for 30 months or more. At 30 months the only two significant parameters were the type of myocardial protection (p = 0.024) and the year of operation (before 1977 or after [precardioplegia era or after], p = 0.011). There were 70 late deaths during the entire follow-up period. The univariate (log-rank statistics) incremental risk factor for late death was the type of tricuspid prosthesis (Smeloff-Cutter and Kay-Shiley versus St. Jude Medical versus bioprosthesis) (p = 0.04). A trend was observed for the type of operative myocardial protection (normothermia and coronary perfusion) (p = 0.06) and preoperative New York Heart Association functional class IV (p = 0.055). Actuarial survival was 74% at 60 months and 23.4% at 180 months. Cumulative follow-up added up to 1015 patient-years. In a more detailed analysis of the effect on survival of the type of tricuspid prosthesis, a significant difference was observed between the bioprostheses and some older mechanical prostheses (Smeloff-Cutter and Kay-Shiley) (p = 0.04) but not between the bioprostheses and the bileaflet valves (p = 0.15). When the follow-up period was stratified according to less than 7 years and more than 7 years of follow-up, no difference was observed for the first period, but for the late follow-up the new mechanical prostheses did better than the bioprostheses (p = 0.05), suggesting a degradation of the bioprostheses after 7 years and favoring mechanical prostheses for those patients with a good long-term prognosis.

Actuarial Analysis↗

Comparative study of limited intentional normovolaemic haemodilution in patients with left main coronary artery stenosis.

Intentional normovolaemic haemodilution is a blood saving technique which can be performed when major blood loss is expected. Severe coronary artery disease and particularly left main stenosis are considered a contraindication for intentional normovolaemic haemodilution. The effects and complications of limited intentional normovolaemic haemodilution in patients with left main coronary artery stenosis scheduled for coronary artery bypass grafting were evaluated. Patients were randomly allocated to two groups: group A (n = 15) underwent limited intentional normovolaemic haemodilution to a haematocrit of 34%; group B (n = 15), no intentional normovolaemic haemodilution was performed. In both groups succinyl-linked gelatin was used to maintain normovolaemia. Haemodynamic parameters were kept as constant as possible. In group A, a mean (SD) volume of 785 (250) ml of blood was withdrawn [range 500-1200 ml]. ST segment changes occurred on the ECG in three patients in each group. There were no statistically significant differences for frequency, maximum deflection and duration of ST-segment changes. Limited intentional normovolaemic haemodilution can be performed safely in patients with left main coronary artery stenosis. In this study it was not associated with increased frequency, severity or duration of ST-segment changes, or with arrhythmias or haemodynamic instability.

Aged↗

D-901 neonatal oxygenator: a new perspective.

Five infants with congenital heart disease were perfused with the D-901 neonatal oxygenator at the time of their cardiac surgery. The ability to reduce the prime volume below the blood volume as well as the blood handling and gas transfer characteristics were studied. In all cases the prime volume was less than or equal to the blood volume of the patient. This resulted in a reduction in the use of homologous blood products. Due to the concept of the D-901 it was possible to adapt the tubing in such a way that a complete prime of 220 ml was obtained. The device had a maximum oxygen transfer of 45 ml/min. The maximum carbon dioxide removal was 50 ml/min at a blood gas ratio of one. The mean platelet count post bypass decreased to 91% of the baseline value. Mean free haemoglobin levels increased to 86 mg/100 ml at 120 minutes of bypass. We conclude that the D-901 oxygenator opens new perspectives for perfusion in small babies in terms of priming volume and use of homologous blood products while maintaining good gas transfer characteristics. However, larger series are necessary to expand our experience with this device and its limitations. No specific problems related to the device were encountered and all infants had an uneventful postoperative course.

Blood Proteins↗