PubMed Health⌕ Search

Biomedical subjects

K Frazer

Publications and source records attributed to K Frazer.

7 recordsLinked to original sources

The Mouse Genome Database (MGD): integrating biology with the genome.

The Mouse Genome Database (MGD) is one component of the Mouse Genome Informatics (MGI) system (http://www.informatics.jax.org), a community database resource for the laboratory mouse. MGD strives to provide a comprehensive knowledgebase about the mouse with experiments and data annotated from both literature and online sources. MGD curates and presents consensus and experimental data representations of genetic, genotype (sequence) and phenotype information including highly detailed reports about genes and gene products. Primary foci of integration are through representations of relationships between genes, sequences and phenotypes. MGD collaborates with other bioinformatics groups to curate a definitive set of information about the laboratory mouse and to build and implement the data and semantic standards that are essential for comparative genome analysis. Recent developments in MGD discussed here include an extensive integration of the mouse sequence data and substantial revisions in the presentation, query and visualization of sequence data.

Animals↗

Controlling the caloric labyrinthine stimulus: restoring surface temperature.

The duration of the conventional caloric stimulus is too long and the termination of the stimulus is uncontrolled. This study explores the use of a brief terminal "washout" irrigation pulse at 37 degrees C which is intended to 1. shorten the duration of action of the caloric stimulus and 2. eliminate uncertainty over the magnitude and duration of the terminal portion of the thermal labyrinthine stimulus. Twelve normal subjects were tested with 1. conventional 30-second irrigations, 2. 30-second irrigations plus a "washout" pulse, and 3. temperature-switching caloric (TSC) irrigations plus a "washout" pulse. Clinical test scores were comparable with all three irrigation methods. The "washout" pulse produced only a slight shortening of the conventional 30-second irrigation responses.

Adult↗

Epidemiology, pathogenesis, and genetics of acoustic tumors.

This article reviews the epidemiology of both unilateral and bilateral (NF-2) acoustic tumors. The growth rate of acoustic tumors is examined from a clinical, radiographic, and laboratory perspective. The anatomic, histologic, and biochemical considerations as well as the influences of sex hormones on acoustic tumor formation are reviewed. Also presented are an update on the laboratory search for the NF-2 gene on chromosome 22 and recently identified DNA markers. Predictions are made concerning the potential future applications of genetic testing for prenatal or presymptomatic diagnosis of the disease that causes bilateral acoustic tumors.

Female↗

A novel and rapid method for isolating sequences adjacent to rare cutting sites and their use in physical mapping.

We describe a simple PCR based technique which can be used to isolate sequences adjacent to rare cutter sites and can subsequently be employed for the construction of long range physical maps. The method involves the ligation of an adaptor to rare cutter sequences and its use as a target for forward priming in PCR. Primers to Alu repeat elements initiate synthesis of the reverse strand. Using this technique any rare cutter site which has a repeat element within amplification range can be cloned. We have isolated six unique sequences around NotI sites from an irradiation reduced hybrid containing a fragment of human chromosome 22 and are using these for physical mapping around the Ewing's sarcoma translocation breakpoint on chromosome 22.

Base Sequence↗

Simultaneous determination of total IgE and allergen-specific IgE in serum by the MAST chemiluminescent assay system.

We have developed a chemiluminescent immunoenzymometric system. The first commercial application of this chemiluminescent assay (CLA) is the measurement of total IgE and allergen-specific IgE in human serum. The CLA system is a second-generation adaptation of the MAST RIA allergy profiling system. The MAST CLA system assay protocol consists of three steps: overnight incubation of serum, a 4-h incubation with enzyme-labeled antibody, and a 30-min chemiluminescent reaction, which produces a visible image (immunograph) on high-speed Polaroid instant film. The densities of the bands produced on the film are quantified with an inexpensive microprocessor-controlled infrared transmittance densitometer. The novel luminogenic substrates used yield a constant light output for over 2 h with an intensity at least 10-fold greater than that of commercial chemiluminescent reagents. The MAST CLA system exhibits sensitivity, specificity, and precision equal to that of the MAST RIA system (r = 0.96 for 40 serum samples analyzed with 25 allergens). As many as 35 different allergens per sample can be quantified in a single assay. The MAST CLA system requires no standard curve or volume-dependent pipetting steps, incorporates both positive and negative controls for each sample, and quantifies allergen-specific IgE at picomolar concentrations.

Allergens↗