Use of three-dimensional sonomicrometry to study the motion of the mitral valve.

To develop an anatomically correct mitral valve prosthesis, one needs to study the dynamics of the mitral valve apparatus in vivo. The authors used three-dimensional (3D) sonomicrometry and custom visualization software to develop a system to study the mitral valve. Sixteen ultrasonic transducers each were implanted into the hearts of pigs under cardiopulmonary bypass. Four of these crystals were affixed to the base and apex of both papillary muscles, four were attached to the free edge of the anterior and posterior leaflets where the main chordae attach, six were placed around the mitral annulus, and two were affixed to the epicardial wall. The digital sonomicrometer system sequentially fired each transducer and listened for an ultrasound signal at the other 15. This process was repeated so that all 16 transducers were sequentially fired, and each cycle of 16 was repeated 200 times/sec. The matrix of distances obtained between all the combinations of pairs of the 16 transducers was converted to x, y, z coordinates, the shape of the mitral valve apparatus was reconstructed in 3D on a graphics computer, and the valve's motion was analyzed over several cardiac cycles. The authors conclude that mapping of the mitral valve apparatus in pigs by 3D sonomicrometry provides quantitative measurements that can aid in the design of a mitral valve prosthesis that closely replicates the anatomy and function of the natural valve.

Animals↗

Heat from an implanted power source is mainly dissipated by blood perfusion.

Heat dissipation and its effects on tissue and blood interfaces are common problems associated with the development and increased use of artificial hearts, because all of the implantable actuators for artificial hearts generate waste heat due to inefficiencies of energy conversion. To determine the mechanisms of heat dissipation from artificial hearts, heated disks producing constant heat fluxes of 0.08 watts/cm2 were implanted adjacent to the left lung and the latissimus dorsi muscle in calves for 2 weeks, 4 weeks, and 7 weeks. At the end of each experiment, a series of acute studies was performed in which blood perfusion to the heated tissue was decreased or stopped to observe the contribution of blood perfusion to heat dissipation. The cooling effect of ventilation was also examined to determine its relative contribution to heat dissipation in lung tissue by decreasing the minute ventilation volume. The importance of blood perfusion for heat dissipation was demonstrated by the temperature rise after cessation of blood perfusion to the heated tissue. The contribution of ventilation to heat dissipation in the heated lung tissue was minimal. Contribution of total blood perfusion to heat dissipation was increased with time in the muscle tissue, which has relatively low resting blood perfusion, but not in the lung tissue, which has relatively high blood perfusion. In the heated muscle tissue, the in vivo adaptive response to chronic heat was functionally shown by the increased perfusion. In conclusion, blood perfusion was the main mechanism of heat dissipation from tissues that were adjacent to an implanted power source.

Adaptation, Physiological↗