[First experiences with a 6F-sheath compatible self-expanding nitinol stent].

BACKGROUND: To evaluate the efficacy, safety and limitation of a new 6F-compatible nitinol stent (Dynalink(TM). MATERIAL AND METHODS: We treated 50 patients (17 women, 33 men, mean age 72 +/- 8 years) by implanting 80 Dynalink(TM)-stents into 75 vessels during a 6-month period. Target lesions were: iliac artery: 25, femoral artery: 31, popliteal artery: 16, femoro-popliteal bypass: 5, subclavian vein: 3. Preinterventional Rutherford classifications: Class 1 : 3 legs (5 %), class 2 : 27 legs (51 %), class 3 : 16 legs (31 %), class 4 : 2 legs (4 %), class 5 : 5 legs (9 %). 40 % stents each were implanted ipsilateral, 60 % cross-over. RESULTS: All interventions were successful regardless of a sometimes anatomically difficult access to the lesion. The device was characterised by a high flexibility and radial force and the stent did not shorten. COMPLICATIONS: One distal stent dislocation during placement occurred, no puncture site complication. The mean diameter stenosis was reduced from 91 +/- 10 % (75 - 100 %) to 4 +/- 8 % (0 - 30 %). The ankle-brachial index was improved from 0.46 +/- 0.22 to 0.75 +/- 0.23 (p < 0.001). Post-interventional Rutherford classifications: Class 0 : 43 legs (81 %), class 1 : 5 legs (4,5 %), class 5 : 5 legs (4,5 %). CONCLUSIONS: The new 6F-sheath compatible nitinol stent is characterised by a good flexibility, radial force, and a lack of shortening. By the reduction of the diameter of the device to 6F, the potential risk of a local bleeding complication may be reduced and 6F sealing devices will be usable. Disadvantages are the 0.018 inch guide-wire lumen and the limited stent sizes.

Adult↗

[The Straub-Rotarex thrombectomy system: initial experiences].

BACKGROUND: To evaluate the efficacy, safety and limitations of a new rotational thrombectomy device (Straub-Rotarex) in clinical practice. MATERIAL AND METHODS: The Straub-Rotarex catheter is a new, wire-guided rotational thrombectomy device for the treatment of acute and subacute occlusions of the femoro-popliteal arteries. Over a 6-month period, 28 patients (64% male, mean age 69 +/- 9.5, 51-91 years) with 31 legs, mean duration of occlusion 4.4 +/- 4 (0-20) weeks, mean occlusion length 22 +/- 11 (5-40) cm were treated with the device, 5 of them in a cross-over technique. Target lesions: Aortic-femoral bypass, common iliac artery, external iliac artery, common femoral artery: 1 each, superficial femoral artery: 23, popliteal artery: 17. Initial stage of claudication: IIa: 6%, IIb: 72%, III: 16%, IV: 6%. RESULTS: Primary success rate: 90% (ipsilateral: 100%, cross-over: 40%). Stage of claudication after intervention: I: 85%, IIa: 7%, III: 4%, IV 4%, one amputation. 3-months follow-up: stage I: 86% (n = 24), IIa: 14% (n = 4), one femoro-popliteal bypass. Restenosis rate 18%. 6-months follow-up: stage I: 56% (n = 9), IIa: 31% (n = 5), IIb: 13% (n = 2). Restenosis rate 56%. COMPLICATIONS: 32% (5 perforations, three cases of embolism after PTA, one wire-induced dissection, one retroperitoneal bleeding coming from the puncture site). CONCLUSIONS: The new device is a useful tool for the treatment of (sub)acute long-distance occlusions of the SFA and popliteal artery and in-stent restenosis as well in antegrade technique. Main complications are perforations. Cross-over interventions can only be done in special cases.

Aged↗

Oral immunotherapy with grass pollen in enterosoluble capsules. A prospective study of the clinical and immunological response.

In a prospective study spanning 2 years, 60 patients with grass pollen allergy were treated with either a low dose oral, a high dose oral or a subcutaneous hyposensitization regime. No significant improvement was seen in the orally treated patients whereas those on the subcutaneous hyposensitization regime demonstrated a decreased specific cutaneous reactivity, a rise in specific IgG antibodies and a reduction in symptoms. This study suggests that oral hyposensitization, even with enterosoluble grass pollen capsules, is ineffective.