Human albumin administration in critically ill patients. Some patients may benefit.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to K H Shwe.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We have investigated the prevalence of a recently reported genetic variation in the prothrombin gene (G20210A) in patients with an objectively confirmed history of venous thrombosis, 12/219 patients (5.5%) were found to be heterozygous carriers of the 20210A allele. The incidence of the 20210A allele in a group of 164 healthy controls was 1.2% (allele frequency 0.61%, 95% CI 0.08-2.19). When patients with a known alternative hereditary risk factor for venous thrombosis (factor V Leiden mutation or deficiency of antithrombin, protein C or protein S) were excluded, the G20210A variant was found to increase the risk for venous thrombosis by approximately 5-fold (odds ratio 5.4, 95% CI 1.16-25.0). This prothrombin gene sequence variation adds further to the list of recognized genetic risk factors for thrombophilia.
Anti-c is an important Rh antibody that causes haemolytic disease of the newborn (HDN). We have carried out a retrospective analysis of the clinical outcome of pregnancy in 120 mothers with anti-c. Of these, 100 gave birth to c-positive infants, of whom 14 had severe HDN requiring exchange transfusion. In all of these, the maternal level was 9.5 iu/ml or greater. Of the 29 women with anti-c levels of 9.5 iu/ml or above, in addition to the 14 with severely affected infants, 15 had infants requiring only phototherapy or no treatment. Our observations suggest that when the anti-c level is below 7.5 iu/ml, the fetus is unlikely to be seriously affected and invasive obstetric intervention is unnecessary. Of the 120 women studied, 50% had had a blood transfusion, in most cases for obstetric complications in a previous pregnancy. Although it was not possible to attribute alloimmunization to blood transfusion rather than previous pregnancy in any individual case, this observation points to the value of routine c typing as part of antenatal screening, so that c-negative blood can be selected.
AIMS: To evaluate an indirect immunofluorescence flow cytometry technique in a series of patients with large fetomaternal haemorrhage (FMH). METHODS: Patient samples identified by Kleihauer testing in local laboratories as having FMH > 4 ml were sent for flow cytometric analysis. In a proportion of cases the mothers received anti-D immunoglobulin prophylaxis according to the flow cytometer estimate of FMH volume. RESULTS: Forty three cases of FMH were studied prospectively. The correlation between Kleihauer and flow cytometry results was poor. In 38 (88%) cases the size of FMH quantitated by flow cytometry was lower than that estimated using the Kleihauer technique. In 13 (30%) cases no Rh D immunoglobulin positive cells were detected by flow cytometry. Centralised review of the original Kleihauer films using a calibrated microscope resulted in improved, but still suboptimal correlation with flow cytometry results. In 15 cases anti-D immunoglobulin was given according to the flow cytometer estimation of FMH size, resulting in a 58% reduction in the amount of anti-D immunoglobulin given. None of the patients were immunised when tested six months later. CONCLUSIONS: Flow cytometry is helpful for the accurate quantitation and management of patients with large FMH and in cases where the presence of maternal haemoglobin F containing cells renders the Kleihauer technique inaccurate. Worthwhile reductions in the use of anti-D immunoglobulin can be achieved.
Explore the source record for details and available documents.
Blood samples from 9,215 blood donors in three U.K. centres (North London, Bristol and Manchester) were tested for their alanine aminotransferase (ALT) level and the presence of anti-HBc and anti-HCV. This paper presents the results of the ALT and anti-HBc tests. The prevalence of ALT > 45 IU/l was 3.1% overall (North London 3.06%, Bristol 4.56% and Manchester 1.97%). Manchester results were skewed by the methodology used for ALT measurement, highlighting the need for standard test methods. Anti-HBc was detected using the Wellcome enzyme-immunosorbent assay (EIA) and confirmatory testing was performed using a radioimmunoassay (RIA) and the Corecell haemagglutination assay. Repeat reactive rates were 0.9, 0.79 and 0.94% for North London, Bristol and Manchester, respectively, with an overall rate of 0.9%. The confirmed positive rate was 0.73, 0.53 and 0.65% for the three centres with an overall rate of 0.63%. Donors with an ALT > 45 IU/l, or with confirmed anti-HBc, were interviewed with a medical questionnaire for risk factors. The major contributing factors in donors with a raised ALT were alcohol consumption and obesity.
Explore the source record for details and available documents.