PubMed HealthSearch

Biomedical subjects

K Hellsing

Publications and source records attributed to K Hellsing.

At least 37 records · Page 2Linked to original sources

Lipoprotein-lipase activity in subcutaneous, adipose tissue in healthy subjects: variation of activity in a population of 60-year-old men.

The lipoprotein-lipase activity (LPLA) in the abdominal, subcutaneous, adipose tissue was studied in a random sample (n = 69) of 60-year-old men. A new method for the quantification of LPLA was applied. The mean value was 67 mU/g when expressed per gram (wet weight) of adipose tissue. Several subjects within the lower part of the range of adipose-tissue LPLA values had low concentrations of serum-triglycerides (S-TG). There was no correlation between the LPLA and S-TG concentrations in the fasting state. Among the 69 subjects, four had newly detected diabetes mellitus and had significantly lower LPLA in the adipose tissue than the control group. The fat-cell size and the LPLA per gram of adipose tissue were not correlated. Thus, obesity without diabetes mellitus does not imply a low LPLA concentration in adipose tissue. The variation of the concentration of adipose-tissue LPLA in the fasting state in this population was explained only to a minor extent by the variation of S-insulin and blood-glucose parameters, when analysed statistically by a stepwise multiple-regression technique.

Abdominal Muscles

Pre-treatment of serum samples for immunonephelometric analysis by precipitation with polyethylene glycol.

A pre-treatment schedule for plasma samples to be analysed with immunonephelometry has been worked out using polyethylene glycol 6000 for precipitating the lipoproteins. The pre-treatment conditions have been studied in detail. By decreasing the blanks in immunonephelometric analysis a greater sensitivity of the method was gained. this was shown by performing analyses of S-beta2-microglobulin to concentrations below 1 mg/l. Another advantage with such a pretreatment is that blank determinations can be omitted for S-transferrin analysis and probably other analyses since the blanks in different samples are reduced to almost the same level.

Beta-Globulins

Calcium, phosphate and albumin in serum. A population study with special reference to renal stone formers and the prevalence of hyperparathyroidism in middle-aged men.

Serum valuse for calcium, phosphate and albumin have been determined in a population study of 2322 49-50-year-old men participating in a health examination survey. Calcium and albumin were significantly correlated (r = 0.34) but adjustment for albumin only caused minor effects on the distribution of calcium. No inverse relationship was found between calcium and phosphate. Seasonal variations over the three years of the health survey could not be established for either calcium or phosphate, whereas there was a slight tendency for albumin to decline during summer. The prevalence of hyperparathyroidism (HPT) in this population of men up to the age of 50 was 0.3% and among those with recurrent renal stones 5.3%. All subjects with verified HPT had a history of recurrent renal stones. One man on thiazide treatment had a slight elevation of calcium which returned to normal after cessation of the drug. No other case of hypercalcemia besides those caused by HPT was found. Mean values and frequency distributions for calcium, phosphate and albumin were almost identical in renal stone formers and matched controls. Hence it seems likely that other factors than those which markedly affect serum levels of calcium and phosphate are of major importance in common renal stone formation.

Age Factors

Pathophysiology in the acute afferent loop syndrome. A study in rats.

The afferent loop syndrome, i.e. occlusion of an afferent intestinal loop after a Billroth II partial gastrectomy, was induced in rats. After various time intervals the animals were killed and the haematocrit and serum osmolality were determined. The content of the occluded loop was analysed with respect to volume, bacterial flora and osmolality. In some cases a sample of the content was incubated at 37 degrees C and the osmolality determined at regular intervals. Groups of animals were studied in this way after 30 min or 1, 4, 8 or 12 h of occlusion. The haematocrit rose with time after the occlusion. The osmolality of the plasma and of the content of the occluded loop did not increase. The volume of fluid in the occluded loop increased continuously with time--from an average of 0.5 ml in the control cases to 6.1 ml after 12 h of occlusion. Experiments in vitro showed that the initial osmolality of the content of the loop was 300 mOsm. After incubation of the samples this increased by 43 to 146 percent. The bacterial content of the loop, including Clostridium perfringens, increased significantly. The results indicate that a marked breakdown of substances takes place in such an occluded intestinal loop, which increases the osmolality. As a result fluid is immediately attracted to the loop to keep the osmolality constant. A combination of this fluid increase due to osmosis and contractions of the intestinal wall leads to a pressure in the occluded loop which considerably exceeds the pressure in the common bile duct due to secretions from the pancreas and liver.

Acute Disease

Gemfibrozil as a lipid lowering compound in hyperlipoproteinaemia. A placebo-controlled cross-over trial.

The efficacy of gemfibrozil in lowering increased serum lipoprotein concentrations was tested in a placebo-controlled cross-over trial on 30 patients. Administered in a dose of 1200 mg daily, gemfibrozil reduced increased serum triglyceride levels by approximately 50% and reduced increased serum cholesterol concentrations by about 20%. Elevated VLDL triglyceride levels were reduced by 60%, and increased LDL cholesterol concentrations were reduced by approximately 20%. The mean HDL cholesterol concentration increased during gemfibrozil treatment. No adverse reactions attributable to gemfibrozil were recorded during the trial.

Adipose Tissue

Screening for cystic fibrosis by analysis of albumin in meconium.

A clinical study of the albumin content in meconium was performed on two categories of newborn infants: a screening series of 8,830 infants and a high-risk group for Cystic Fibrosis (CF) of 70 infants. A single radial immunodiffusion technique and test strips were used. Three CF infants were detected in the screening series (1:3,000) and 16 in the high-risk group. The diagnostic accuracy for CF was fairly good. The specificity was 99.8% for the immunodiffusion technique and 99.2% for test strips. A high concentration of albumin in meconium was found not only in CF but also in preterm babies and infants with gastrointestinal disturbances, such as atresias, malaena neonatorum and malabsorption syndromes. The sensitivity was 90% for the immunodiffusion technique and 78% for the test strip. False-negative results were probably due to proteolytic activity and might be avoided if the samples are stored at a low temperature before analysis. CF screening of all meconiums by the use of test strips followed by analysis of positive tests by the immunodiffusion technique is suggested.

Albumins

Electronic timing of a high-speed immunonephelometric continuous-flow system.

We describe a high-speed immunoephelometric continuous-flow system. The mechanical timing asembly and cams of the sampler were replaced by an external electronic control unit. Improved sampling precision, speeds of 2 to 900 samples per hour, and a wide variety of sample-to-wash ratios are the most important advantages of the unit. We analyzed albumin and fibrinogen at speeds of 150, 180, and 210 samples per hour. Carry-over studies showed that, in clinical practice, it should be possible to run the system at 150 samples per hour with an interaction of less than 5% and a precision (CV) of around 4%. Comparative studies with a previously described method, run at 60 samples per hour, showed correlation coefficients of 0.968 and 0.935 for albumin and fibrinogen, respectively. The electronic control unit can be used to increase speed and improve sampling precision of any continuous-flow system. An immunonephelometric system equipped with this device provided fast and reliable results, and required less antiserum than other systems described.

Animals

Cystic fibrosis detection by means of a test-strip.

The effectiveness of meconium screening for albumin as an indication of cystic fibrosis is examined. BM-Test Meconium was applied to 69,000 investigations. In 60 positive tests, cystic fibrosis was confirmed later. No increased albumin content was observed in four cases of cystic fibrosis.

Albumins