PubMed Health⌕ Search

Biomedical subjects

K Hittmair

Publications and source records attributed to K Hittmair.

At least 19 recordsLinked to original sources

Iliopsoas abscess with iliac and femoral vein thrombosis in an adult Siberian husky.

A nine-year-old, male Siberian husky was presented with fever, decreased appetite and activity, non-weightbearing lameness, and oedematous swelling of the right inguinal and preputial area and the right hindlimb. An abscess within the right iliopsoas muscle, with severe thrombosis of the iliac and femoral vein, was diagnosed by haematology and diagnostic imaging. The abscess and adjoining lymph node were removed surgically through a median coellotomy. The isolated pathogen was Staphylococcus intermedius. Clinical signs resolved completely after surgery. Antimicrobial therapy was continued for four weeks. Within the follow-up period of six months, no recurrence of the clinical signs was detected.

Animals↗

Creation of transjugular intrahepatic portosystemic shunts with stent-grafts: initial experiences with a polytetrafluoroethylene-covered nitinol endoprosthesis.

PURPOSE: To evaluate the safety and performance of a recently developed expanded polytetrafluoroethylene (ePTFE)-covered nitinol stent-graft to create transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and related complications. MATERIALS AND METHODS: The ePTFE-covered nitinol stent-graft was used to create TIPS in 16 patients with recurrent variceal bleeding (n = 13) or refractory ascites (n = 3). Follow-up was performed with duplex ultrasonography, clinical assessment, and venography at 6 months. Technical success and portosystemic pressure gradients (PPGs) before and after stent-graft implantation and at follow-up were assessed. Two patients died during follow-up. Histopathologic follow-up data were available for one patient at autopsy and for the other after liver transplantation. RESULTS: The implantation technical success rate was 100%. Mean (+/- SD) PPG was reduced from 24 mm Hg +/- 5 to 9 mm Hg +/- 2. Histopathologic analysis of the explanted endoprostheses revealed no inflammatory response or neointima formation. The venographic follow-up data available for 10 patients demonstrated 100% in-graft patency (mean follow-up, 289 days +/- 26). Revisions with implantation of a new ePTFE-covered nitinol stent-graft or another commercially available stent in 10 patients were necessary because of hepatic vein stenosis above the grafted portion and/or relative diameter mismatch causing TIPS dysfunction. CONCLUSION: The ePTFE-covered nitinol stent-graft was used successfully to create TIPS and has the potential to prolong TIPS patency upon complete coverage to the hepatocaval junction.

Adult↗

Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.

PURPOSE: To compare the uniformity of aortoiliac opacification obtained from uniphasic contrast medium injections versus individualized biphasic injections at computed tomographic (CT) angiography. MATERIALS AND METHODS: Thirty-two patients with an abdominal aortic aneurysm underwent CT angiography. In 16 patients (group 1), 120 mL of contrast material was administered at a flow rate of 4 mL/sec. In the other 16 patients (group 2), biphasic injection protocols were computed by using mathematic deconvolution of each patient's time-attenuation response to a standardized test injection. Attenuation uniformity was quantified as the "plateau deviation" of enhancement values, which were calculated as the SD of the time-contiguous attenuation values observed during the 30-second scanning period. RESULTS: Group 2 patients received between 77 and 165 mL (mean, 115 mL) of contrast medium. Initial flow rates ranged from 4.1 to 10.0 mL/sec (mean, 6.8 mL/sec) for the first 4-6 seconds; continuing flow rates ranged from 2.0 to 4.8 mL/sec (mean, 3.1 mL/sec) for the remaining 24-26 seconds. The plateau deviation was significantly smaller in group 2 patients (19 HU) versus group 1 patients (38 HU, P <.001). CONCLUSION: At CT angiography, tailored biphasic injections led to more uniform aortoiliac enhancement, compared with standard uniphasic injections of contrast medium.

Aged↗

[Contrast optimization in CT angiography].

This paper compares different contrast injection techniques for optimizing vessel contrast in CT angiography (CTA). The optimal vessel contrast shall be defined as constant strong enhancement confined to the scanning interval. This "plateau enhancement" guarantees high-quality CTA images and should therefore be approximated during every CTA examination by an appropriate contrast injection protocol. With well-established injection techniques such as the standard bolus technique (constant uniphasic contrast bolus for all patients) or adjustment of the scan delay, considerable individual differences in the arterial enhancement can be observed, and a nondiagnostic examination or an inefficient use of contrast agent might be the result in a particular patient. Therefore, two sophisticated mathematical models have recently been developed for analyzing the individual enhancement characteristics. These models can be exploited to predict the arterial enhancement for any given intravenous contrast bolus in any patient and to optimize the contrast bolus in order to approach the ideal "plateau enhancement." These techniques have to prove their effectiveness in larger clinical series.

Aged↗

Subjective differentiation of normal and pathological bronchi on thin-section CT: impact of observer training.

The effect of observer training on sensitivity, specificity and interobserver agreement in the differentiation between normal and pathological bronchi on computed tomography (CT) was studied. The wall thickness of bronchi with normal walls and with pathologically thickened walls were subjectively scored by three independent observers before and after a training period of 2 weeks. Sensitivity, specificity and interobserver agreement were calculated for reading sessions before and after training. Increase and decrease in agreement after training were determined. There was a statistically significant difference (p=0.001) between objectively measured wall thickness of normal and pathological bronchi, both for reference bronchi and for bronchi used for reading sessions. While training increased interobserver agreement, it had no effect on sensitivity (0.46 versus 0.44 after training) and specificity (0.71 versus 0.72 after training) in detecting pathological bronchi. Increased agreement after training was significantly (p=0.001) more frequent than decreased agreement. There is a discrepancy between the effect of training on interobserver agreement and on sensitivity and specificity in the subjective differentiation between normal and pathological bronchi. Interobserver agreement alone is not a reliable indicator of a beneficial effect of training in the evaluation of this parameter.

Bronchi↗

Vaccinations and steroids in MS: effects on disease progression and mood.

OBJECTIVE: To investigate the effects of vaccinations and steroids on disease progression and mood in patients with multiple sclerosis (MS). MATERIAL AND METHODS: Twenty-three patients with clinically definite MS were questioned with respect to vaccination history and the cumulative dose of steroids given during their life-time. EDSS scores and MRI scans of the brain were obtained and used to quantify clinical and MRI disease progression. Mood was assessed by using a self-estimated adjective mood scale. RESULTS: The number of vaccinations showed no effect on disease progression or mood. High cumulative steroid doses were associated with rapid MRI disease progression and the number of supratentorial MRI lesions. The absence of band-like MRI lesions was correlated with rapid clinical and MRI disease progression. Self-estimated mood tended to be worse in patients with chronic-progressive MS compared to those with relapsing-remitting MS. CONCLUSION: Neither clinical nor MRI-documented disease progression nor mood are influenced by the total number of vaccinations whereas high cumulative steroid doses and the absence of band-like MRI lesions indicate rapidly progressive MS. Self-estimated mood tends to be worse in patients with chronic-progressive MS compared to patients with relapsing-remitting MS.

Adult↗

Growing blood clot mimicking an aneurysm on postoperative computerized tomography and magnetic resonance imaging studies. Case report and review of the literature.

The authors describe the case of a 15-year-old boy who underwent resection of a large left temporal tumor. During a normal postoperative course, computerized tomography (CT) scanning demonstrated a spherically hyperdense structure near the internal carotid artery, enlarging on a control CT scan. A suspected false aneurysm was confirmed on magnetic resonance imaging; angiographic studies were negative. The authors believed they were dealing with a thrombosed false aneurysm and they performed operative revision. Intraoperatively the "aneurysm" could be dissected off the internal carotid artery and no lesion of the arterial wall was obvious. Histological findings showed a fresh blood clot. This case demonstrates that a blood clot may mimic an aneurysm on CT and magnetic resonance studies, which has not been described earlier. The origin of the blood clot remains unclear.

Adolescent↗

Imaging of the brain using the fast-spin-echo and gradient-spin-echo techniques.

The aim of our study was to compare gradient-spin-echo (GRASE) to fast-spin-echo (FSE) sequences for fast T2-weighted MR imaging of the brain. Thirty-one patients with high-signal-intensity lesions on T2-weighted images were examined on a 1.5-T MR system. The FSE and GRASE sequences with identical sequence parameters were obtained and compared side by side. Image assessment criteria included lesion conspicuity, contrast between different types of normal tissue, and image artifacts. In addition, signal-to-noise, contrast-to-noise, and contrast ratios and were determined. The FSE technique demonstrated more lesions than GRASE and with generally better conspicuity. Smaller lesions in particular were better demonstrated on FSE because of lower image noise and slightly weaker image artifacts. Gray-white differentiation was better on FSE. Ferritin and hemosiderin depositions appeared darker on GRASE, which resulted in better contrast. Fatty tissue was less bright on GRASE. With current standard hardware equipment, the FSE technique seems preferable to GRASE for fast T2-weighted routine MR imaging of the brain. For the assessment of hemosiderin or ferritin depositions, GRASE might be considered.

Adipose Tissue↗

Double inversion recovery imaging of the brain: initial experience and comparison with fluid attenuated inversion recovery imaging.

The purpose of this study was to evaluate the diagnostic efficacy of the double inversion recovery fast spin echo (DIR-FSE) sequence for brain imaging compared to the fluid-attenuated inversion recovery (FLAIR) sequence. DIR-FSE and FLAIR-FSE sequences were obtained and compared side by side. Image assessment criteria included lesion conspicuity, contrast between different types of normal tissue, image quality, and artifacts. In addition, contrast ratios and contrast-to-noise ratios were determined. Scan time of DIR-FSE was 33% longer than scan time of FLAIR-FSE. Overall lesion conspicuity was equal on DIR-FSE and FLAIR-FSE; however, DIR-FSE showed particular advantages for infratentorial lesions and lesions with only poor contrast on T2-weighted images, whereas FLAIR was slightly superior for small superficial cerebral abnormalities. Gray-white differentiation was better with DIR-FSE. Cerebrospinal fluid suppression was equal on both sequences; cerebrospinal fluid pulsation artifacts were more pronounced on DIR-FSE but did not cause diagnostic difficulties on these images. We conclude that DIR-FSE might be obtained if infratentorial lesions and abnormalities with only slightly prolonged T2 relaxation times are suspected. Otherwise, FLAIR-FSE seems preferable.

Adolescent↗

Impact of spinal degenerative changes on the evaluation of bone mineral density with dual energy X-ray absorptiometry (DXA).

The purpose of this study is to evaluate degenerative factors in a postmenopausal patient group and differentiate the influence on bone mineral density (BMD) measurements by dual-energy X-ray absorptiometry (DXA). The patients and methods included an investigation of 144 postmenopausal women (mean 63.3 years) with PA-DXA of the spine. Degenerative factors (osteophytes, osteochondrosis, scoliosis, and vascular calcification) were evaluated from plain lumbar radiographs, their estimated probability was analyzed as a function of age, and their influence on BMD measured by PA-DXA was determined. The results of the study revealed osteophytes in 45.8%, vascular calcifications in 24.3%, scoliosis in 22.2%, osteochondrosis in 21.5%. The estimated probability for degenerative factors increased from 35 to 80% in the 55- to 70- year age group. Osteophytes and osteochondrosis were associated with up to a 14% increase in BMD values (P < 0.001). Vascular calcifications showed a positive trend, whereas scoliosis did not show a discernible influence.We concluded that degenerative factors, except for scoliosis, showed an influence on BMD as measured by DXA. Their prevalence increased rapidly between 55 and 70 years of age. Interpretation of PA-DXA spine data for subjects of or above this age range should be complemented by plain film radiographs.

Absorptiometry, Photon↗

Fast flair imaging of the brain using the fast spin-echo and gradient spin-echo technique.

The purpose of this study was to compare the gradient spin-echo (GRASE) to the fast spin-echo (FSE) implementation of fast fluid-attenuated inversion recovery (FLAIR) sequences for brain imaging. Thirty patients with high signal intensity lesions on T2-weighted images were examined on a 1.5 T MR system. Scan time-minimized thin-section FLAIR-FSE and FLAIR-GRASE sequences were obtained and compared side by side. Image assessment criteria were lesion conspicuity, contrast between different types of normal tissue, image quality, and artifacts. In addition, contrast ratios and contrast-to-noise ratios were determined. Compared to FSF, the GRASE technique allowed a 17% reduction in scan time but conspicuity of small lesions in particular was significantly lower on FLAIR-GRASE images because of higher image noise and increased artifacts. Gray-white differentiation was slightly worse on FLAIR-GRASE. Physiological ferritin deposition appeared slightly darker on FLAIR-GRASE images and susceptibility artifacts were stronger. Fatty tissue was less bright with FLAIR-GRASE. With current standard hardware equipment, the GRASE technique is not an adequate alternative to FSE for the implementation of fast FLAIR sequences in routine clinical MR brain imaging.

Brain↗

Comparison of T2-weighted and fluid-attenuated inversion-recovery fast spin-echo MR sequences in intracerebral AIDS-associated disease.

PURPOSE: To compare the value of fast fluid-attenuated inversion-recovery (FLAIR) with T2-weighted fast spin-echo MR imaging in the detection of acquired immunodeficiency virus (AIDS)-related lesions of the brain. METHODS: Forty-four human immunodeficiency virus (HIV)-positive patients were examined with both sequences on either a 1.0-T or a 1.5-T MR system. The number, size, location, and conspicuity of the lesions were evaluated by two independent observers. Contrast ratios between lesions and normal brain/cerebrospinal fluid were determined, and contrast-to-noise ratios were calculated. RESULTS: FLAIR was found to be superior to T2-weighted fast spin-echo in detection of small lesions and of lesions located in cortical/subcortical regions and deep white matter. The two techniques were equal in delineation of lesions larger than 2 cm and for lesions located in the basal ganglia and posterior fossa. In 24 patients, more lesions were detected with the FLAIR fast spin-echo technique. Lesion/cerebrospinal fluid contrast ratios and contrast-to-noise ratios were significantly higher for the FLAIR fast spin-echo sequences than for the T2-weighted fast spin-echo sequences. CONCLUSION: FLAIR allows early detection of small lesions in subcortical and cortical locations, especially in HIV encephalitis. Because of its improved lesion detection rate and greater overall lesion conspicuity, we believe FLAIR is useful in the evaluation of subtle changes in the brains of AIDS patients with central nervous system disease, and could even replace the T2-weighted fast spin-echo technique.

AIDS Dementia Complex↗

Infratentorial brain maturation: a comparison of MRI at 0.5 and 1.5T.

Our purpose was to establish parameters for normal infratentorial brain maturation at 0.5 and 1.5 T and to evaluate the field strength criteria for the assessment of infratentorial brain maturation with MRI. We examined 27 children with normal psychomotor development (3 days to 24 months) with a 1.5 T system and 22 (4 days to 29 months) with a 0.5 T system; standard T2-weighted spin-echo sequences (TR/TE 2500/90 ms at 1.5 T and TR/TE 2200/90 ms at 0.5 T) were obtained. The signal intensity of infratentorial anatomical structures compared to their surroundings was classified as high, isointense or low by three neuroradiologists. For anatomical structures with age-related contrast changes, the time of these changes was determined statistically for the 0.5 T and 1.5 T system independently. The delineation of the structures without age-related contrast changes at the two field strengths was compared using a chi 2 test. Age-related contrast changed were found in the same anatomical structures ("marker sites") at 0.5 and 1.5 T. Generally, these changes were apparent in larger structures (pons, middle cerebellar peduncles, medulla, cerebellar folia, red nuclei, cerebral peduncles), with only slight field-strength-dependent differences in the time of the contrast changes. Contrast changes from high to isointense signal were observed slightly earlier at 0.5 T and changes from isointense to low signal slightly later at 0.5 T. The delineation of the smaller anatomical structures was significantly better at 1.5 T but these structures did not show age-related contrast changes. The differences in the assessment of infratentorial brain maturation between 0.5 and 1.5 T can be attributed to a lower signal-to-noise ratio at lower magnetic field strengths. These differences do not complicate temporal classification of the stage of infratentorial brain maturation using the same "marker sites" and the same temporal criteria at 0.5 or 1.5 T. However, higher field strengths are preferable for the assessment of smaller structures with physiological signal differences; this may imply better detection of small lesions at higher field strengths.

Age Factors↗

MRI in a case of Sandhoff's disease.

An 18-month-old girl was examined by MRI for progressive psychomotor retardation. T2-weighted images demonstrated abnormal high signal in the putamina and low signal in the thalamus (due probably to calcification). Although the cerebral cortex was markedly atrophic, there were signs of brain enlargement because of swelling of the extensively diseased white matter. The diagnosis of Sandhoff's disease was established by low serum levels of hexosaminidase A and B.

Basal Ganglia↗

Comparison between conventional and fast spin-echo stir sequences.

PURPOSE: To evaluate the common characteristics and differences in contrast behavior of short-TI-inversion-recovery (STIR) and short-TI-inversion-recovery fast spin-echo (TurboSTIR) sequences. MATERIAL AND METHODS: Phantoms doped with increasing doses of Gd-DTPA and a pork-fat phantom were used to evaluate the dependence of the STIR and TurboSTIR signals on the T1 relaxation time. Clinical TurboSTIR images were obtained from 30 patients with musculoskeletal abnormalities and compared to conventional STIR images in 15 cases and to postcontrast TurboSTIR images in another 15 cases. RESULTS: In the phantom measurements, a significantly shorter inversion time (TI) was needed to achieve fat suppression on TurboSTIR images, and, with an identical number of signal averages, contrast-to-noise ratios were lower on TurboSTIR images. These differences between STIR and TurboSTIR can be attributed to the contribution of stimulated echoes to overall TurboSTIR signal and can be compensated by a shorter TI and a higher number of signal averages for TurboSTIR, respectively. With these adaptations, clinical TurboSTIR and STIR images showed an identical contrast behavior with fat suppression and a high sensitivity to pathological lesions but TurboSTIR saved a significant amount of scan time and reduced some types of artifacts. Contrast uptake impaired lesion conspicuity on TurboSTIR images. CONCLUSION: TurboSTIR sequences should replace conventional STIR sequences and should be performed before contrast administration.

Adolescent↗

Field strength dependence of MRI contrast enhancement: phantom measurements and application to dynamic breast imaging.

Differences in MRI-measured contrast enhancement have been used for tissue characterization, particularly for the characterization of mammary tumours. T1 weighted spoiled gradient echo sequences have usually been acquired for this purpose and relative signal intensity increase (Srel) has been determined to quantify contrast uptake. The field strength dependence of this technique is evaluated in this paper by phantom measurements. Srel is compared with the recently introduced "enhancement factor" (EF) and "contrast uptake equivalent" (CE) as a quantitative assessment parameter for contrast uptake. Enhancing tissues were simulated with water phantoms doped with increasing concentrations of Gd-DTPA. Spoiled gradients echo images (FLASH-2D) were obtained on a 0.2 T and 1.5 T MR system. Srel, EF and CE were determined and the results of the phantom measurements were applied to typical types of breast tissues. Srel showed a strong dependence on the magnetic field strength and was greater at higher field strengths. This is because Srel correlates positively with the native T1 which is longer at higher field strengths. Conversely, the EF and CE almost eliminated the distorting influences of the magnetic field strength. CE provided a good approximation of the actual contrast uptake. In practice, the dependence of Srel on the magnetic field strength might cause malignant lesions to be misclassified as benign at low field strengths. Either Srel criteria should be adjusted to magnetic field strength or EF and CE should be used instead of Srel for tissue characterization with dynamic contrast-enhanced MRI.

Breast Neoplasms↗

Power Doppler versus color Doppler imaging in renal allograft evaluation.

The purpose of this study was to evaluate the impact of PDS compared to conventional CDI in the followup of 72 renal allograft patients. Renal allograft vascularization, assessed by PDS and CDI, was scored from 0 to 4, where 0 was the cortical "blush" and 4 was residual central perfusion. These scores were correlated with the resistive index, serum creatinine levels, hematocrit, and, in 35 cases, biopsy results. PDS scores of renal perfusion were one grade lower than CDI scores in 59 of 72 patients and two grades lower in two of 72 patients. A statistically significant correlation was found between PDS scores and the RI (r2 = 0.6, P < 0.05). However, no significant correlation was found between PDS scores and creatinine levels or hematocrit values. PDS scores are not related to histologic findings in renal allograft dysfunction. Overall, five biopsy-related arteriovenous fistulas were detected, two of which were missed on the initial PDS examination. In conclusion, PDS provides more complete visualization of the renal allograft vessel tree than CDI. However, biopsy-related arteriovenous fistulas are better seen by CDI.

Biopsy↗

Spinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.

PURPOSE: To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS: Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal images of T2-weighted and proton density-weighted CSE sequences, T2-weighted FSE sequences with two different sets of sequence parameters, STIR-FSE sequences, and FLAIR-FSE sequences were compared by two independent observers. In addition, contrast-to-noise measurements were obtained. RESULTS: Spinal multiple sclerosis plaques were seen best on STIR-FSE images, which yielded the highest lesion contrast. Among the T2-weighted sequences, the FSE technique provided better image quality than did the CSE technique, but lesion visibility was improved only with a repetition time/echo time of 2500/90; parameters of 3000/150 provided poor lesion contrast but the best myelographic effect and overall image quality. CSE images were degraded by prominent image noise; FLAIR-FSE images showed poor lesion contrast and strong cerebrospinal fluid pulsation artifacts. CONCLUSIONS: The STIR-FSE sequence is the best choice for assessment of spinal multiple sclerosis plaques. For T2-weighted FSE sequences, shorter echo times are advantageous for spinal cord imaging, long echo times are superior for extramedullary and extradural disease. FLAIR-FSE sequences do not contribute much to spinal imaging for multiple sclerosis detection.

Adult↗