PubMed Health⌕ Search

Biomedical subjects

K Homma

Publications and source records attributed to K Homma.

At least 19 recordsLinked to original sources

Beneficial action of candesartan cilexetil plus amlodipine or ACE inhibitors in chronic nondiabetic renal disease.

Although multiple antihypertensive agents are required to control blood pressure (BP) in chronic renal disease, it remains undetermined whether the combination therapy with angiotensin receptor blockers (ARB) plus calcium antagonists or angiotensin-converting enzyme inhibitors (ACEI) confers more preferable action on renal disease than the ARB monotherapy. In the present study, we compared the effect of the combination therapy with ARB plus calcium antagonists/ACEI on proteinuria with that of the ARB monotherapy in chronic nondiabetic renal disease. At 1 month of the drug treatment, the candesartan monotherapy (n=19) reduced BP from 154+/-3/93+/-2 to 146+/-3/88+/-2 mmHg (P<0.05), and a similar magnitude of BP reductions was observed with the combination therapy with candesartan plus ACEI/amlodipine (from 153+/-2/95+/-2 to 144+/-2/88+/-2 mmHg, P<0.05, n=39). The depressor action of these therapies was sustained throughout the 12-month treatment. In contrast, the reduction in proteinuria was greater with the combination therapy (-52+/-3% at 12 months, n=39) than with the candesartan monotherapy (-25+/-3%, n=19), although the baseline values of proteinuria were nearly the same in the candesartan monotherapy group (1.74+/-0.22 g/day) and the combination therapy group (2.10+/-0.19 g/day, P>0.2). Of note, the proteinuria-sparing effect did not differ between the candesartan+ACEI group and the candesartan+amlodipine group. In conclusion, the present study suggests more beneficial action of the combination therapy with ARB plus ACEI/amlodipine than the ARB monotherapy in nondiabetic renal disease. Since the reduction in BP was achieved to the same level, the distinct proteinuria-sparing action of these therapies is attributed to BP-independent mechanisms, which should vary depending on the agents used.

Adult↗

Flow measurements via two-particle azimuthal correlations in Au + Au collisions at sqrt [s(NN)]=130 GeV.

Two-particle azimuthal correlation functions are presented for charged hadrons produced in Au+Au collisions at the Relativistic Heavy Ion Collider (sqrt [s(NN)]=130 GeV). The measurements permit determination of elliptic flow without event-by-event estimation of the reaction plane. The extracted elliptic flow values (v2) show significant sensitivity to both the collision centrality and the transverse momenta of emitted hadrons, suggesting rapid thermalization and relatively strong velocity fields. When scaled by the eccentricity of the collision zone epsilon, the scaled elliptic flow shows little or no dependence on centrality for charged hadrons with relatively low p(T). A breakdown of this epsilon scaling is observed for charged hadrons with pT >1.0 GeV/c.

Journal Article↗

Measurement of Lambda and Lambda(macro) particles in Au+Au collisions at the square root of S(NN) = 130 GeV.

We present results on the measurement of Lambda and Lambda(macro) production in Au+Au collisions at square root of (S (NN) = 130 GeV with the PHENIX detector at the Relativistic Heavy Ion Collider. The transverse momentum spectra were measured for minimum bias and for the 5% most central events. The Lambda;/Lambda ratios are constant as a function of p(T) and the number of participants. The measured net Lambda density is significantly larger than predicted by models based on hadronic strings (e.g., HIJING) but in approximate agreement with models which include the gluon-junction mechanism.

Journal Article↗

Net charge fluctuations in Au + Au interactions at sqrt[s(NN)]=130 GeV.

Data from Au + Au interactions at sqrt[s(NN)]=130 GeV, obtained with the PHENIX detector at the Relativistic Heavy-Ion Collider, are used to investigate local net charge fluctuations among particles produced near midrapidity. According to recent suggestions, such fluctuations may carry information from the quark-gluon plasma. This analysis shows that the fluctuations are dominated by a stochastic distribution of particles, but are also sensitive to other effects, like global charge conservation and resonance decays.

Journal Article↗

Centrality dependence of pi(+/-), K(+/-), p, and (-)p production from sqrt[s(NN)] = 130 GeV Au + Au collisions at RHIC.

Identified pi(+/-), K(+/-), p, and (-)p transverse momentum spectra at midrapidity in sqrt[s(NN)] = 130 GeV Au+Au collisions were measured by the PHENIX experiment at RHIC as a function of collision centrality. Average transverse momenta increase with the number of participating nucleons in a similar way for all particle species. Within errors, all midrapidity particle yields per participant are found to be increasing with the number of participating nucleons. There is an indication that K(+/-), p, and (-)p yields per participant increase faster than the pi(+/-) yields. In central collisions at high transverse momenta (p(T) > or =2 GeV/c), (-)p and p yields are comparable to the pi(+/-) yields.

Journal Article↗

Transverse-mass dependence of two-pion correlations in Au+Au collisions at square root[s(NN)] = 130 GeV.

Two-pion correlations in square root[s(NN)] = 130 GeV Au+Au collisions at RHIC have been measured over a broad range of pair transverse momentum k(T) by the PHENIX experiment at RHIC. The k(T) dependent transverse radii are similar to results from heavy-ion collisions at square root[s(NN)] = 4.1, 4.9, and 17.3 GeV, whereas the longitudinal radius increases monotonically with beam energy. The ratio of the outwards to sidewards transverse radii (R(out)/R(side)) is consistent with unity and independent of k(T).

Journal Article↗

Measurement of single electrons and implications for charm production in Au+Au collisions at square root[s(NN)] = 130 GeV.

Transverse momentum spectra of electrons from Au+Au collisions at square root[s(NN)] = 130 GeV have been measured at midrapidity by the PHENIX experiment at the Relativistic Heavy Ion Collider. The spectra show an excess above the background from photon conversions and light hadron decays. The electron signal is consistent with that expected from semileptonic decays of charm. The yield of the electron signal dN(e)/dy for p(T) > 0.8 GeV/c is 0.025+/-0.004(stat)+/-0.010(syst) in central collisions, and the corresponding charm cross section is 380+/-60(stat)+/-200(syst) microb per binary nucleon-nucleon collision.

Journal Article↗

Impact of calcium antagonists on bleeding time in patients with chronic renal failure.

Haemorrhagic diathesis develops in chronic renal failure, in which calcium antagonists are used widely as antihypertensive agents. Although calcium antagonists are reported to impair platelet function, it has not been examined whether calcium antagonists alter bleeding time. The present study was conducted to clarify whether calcium antagonists affect bleeding time in chronic renal failure. Patients with chronic renal failure without and with calcium antagonists were enrolled (n = 156), and bleeding time (Ivy's method) as well as blood parameters (BUN, creatinine, platelet counts, and haemoglobin) were compared in patients with normal and prolonged bleeding time. Among patients not taking calcium antagonists (n = 34), three cases manifested prolonged bleeding time, whereas abnormal bleeding time was observed in 31 patients out of 122. Positive correlations were observed between bleeding time and BUN in both calcium antagonist-untreated (r = 0.46) and -treated groups (r = 0.25). The odds ratio for prolongation of bleeding time in patients taking calcium antagonists was 3.52 (95% CI, 1.01-12.33). In 12 calcium antagonist-treated patients with prolonged bleeding time, the withdrawal of calcium antagonists markedly shortened bleeding time (from 11.3 +/- 0.8 to 5.4 +/- 0.8 min, P < 0.05, n = 12). In contrast, in the additional group (n = 9), the continued treatment with calcium antagonists had no effect on bleeding time (from 11.7 +/- 0.9 to 10.0 +/- 1.0 min). Despite the inhibitory effect of calcium antagonists on bleeding time, no clinically serious events associated with haemorrhagic diathesis developed. In conclusion, calcium antagonists prolong bleeding time in patients with chronic renal failure. The subclinical (laboratory) effect of calcium antagonists however is not necessarily associated with haemorrhagic events of clinical significance.

Aged↗

Comparison between high-resolution helical CT and pathology in breast examination.

PURPOSE: To determine whether high-resolution helical CT can show the architectural features of breast carcinomas of non-limited extent (non-BCLE) and to establish the CT characteristic morphology of non-BCLE. MATERIAL AND METHODS: We prospectively studied high-resolution helical CT of 136 invasive breast carcinomas before breast-conserving surgery. Non-BCLE were defined as ductal carcinomas in situ and invasive carcinomas beyond 1 cm from the edge of the dominant mass. Non-BCLE were defined as positive if enhanced beyond 1 cm from the edge of the focal enhancement on CT. After surgical resection, specimens were sliced in serial sections at 5-mm intervals, and the gross morphology and histology were correlated with the appearance of the preoperative CT lesion images. RESULTS: Non-BCLE were present in 47 invasive carcinomas. The sensitivity and specificity of non-BCLE evaluation by high-resolution helical CT were 70% and 89%, respectively. The morphology of non-BCLE on CT agreed with histologic findings. The morphological pattern on CT significantly correlated with intraductal tumor density adjacent to invasive tumor. CONCLUSION: Comparison of high-resolution helical CT with histologic data suggests that demonstration of a non-BCLE morphology can make the CT breast carcinoma local staging more accurate.

Breast↗

Suppression of hadrons with large transverse momentum in central Au+Au collisions at root square[s(NN)] = 130 GeV.

Transverse momentum spectra for charged hadrons and for neutral pions in the range 1 GeV/c<p(T)<5 GeV/c have been measured by the PHENIX experiment at RHIC in Au+Au collisions at root square[s(NN)] = 130 GeV. At high p(T) the spectra from peripheral nuclear collisions are consistent with scaling the spectra from p+p collisions by the average number of binary nucleon-nucleon collisions. The spectra from central collisions are significantly suppressed when compared to the binary-scaled p+p expectation, and also when compared to similarly binary-scaled peripheral collisions, indicating a novel nuclear-medium effect in central nuclear collisions at RHIC energies.

Journal Article↗

The core of the motor domain determines the direction of myosin movement.

Myosins constitute a superfamily of at least 18 known classes of molecular motors that move along actin filaments. Myosins move towards the plus end of F-actin filaments; however, it was shown recently that a certain class of myosin, class VI myosin, moves towards the opposite end of F-actin, that is, in the minus direction. As there is a large, unique insertion in the myosin VI head domain between the motor domain and the light-chain-binding domain (the lever arm), it was thought that this insertion alters the angle of the lever-arm switch movement, thereby changing the direction of motility. Here we determine the direction of motility of chimaeric myosins that comprise the motor domain and the lever-arm domain (containing an insert) from myosins that have movement in the opposite direction. The results show that the motor core domain, but neither the large insert nor the converter domain, determines the direction of myosin motility.

Animals↗

Dual regulation of mammalian myosin VI motor function.

Myosin VI is expressed in a variety of cell types and is thought to play a role in membrane trafficking and endocytosis, yet its motor function and regulation are not understood. The present study clarified mammalian myosin VI motor function and regulation at a molecular level. Myosin VI ATPase activity was highly activated by actin with K(actin) of 9 microm. A predominant amount of myosin VI bound to actin in the presence of ATP unlike conventional myosins. K(ATP) was much higher than those of other known myosins, suggesting that myosin VI has a weak affinity or slow binding for ATP. On the other hand, ADP markedly inhibited the actin-activated ATPase activity, suggesting a high affinity for ADP. These results suggested that myosin VI is predominantly in a strong actin binding state during the ATPase cycle. p21-activated kinase 3 phosphorylated myosin VI, and the site was identified as Thr(406). The phosphorylation of myosin VI significantly facilitated the actin-translocating activity of myosin VI. On the other hand, Ca(2+) diminished the actin-translocating activity of myosin VI although the actin-activated ATPase activity was not affected by Ca(2+). Calmodulin was not dissociated from the heavy chain at high Ca(2+), suggesting that a conformational change of calmodulin upon Ca(2+) binding, but not its physical dissociation, determines the inhibition of the motility activity. The present results revealed the dual regulation of myosin VI by phosphorylation and Ca(2+) binding to calmodulin light chain.

Actin Cytoskeleton↗

Measurement of the midrapidity transverse energy distribution from square root of [(s)NN] = 130 GeV Au + Au collisions at RHIC.

The first measurement of energy produced transverse to the beam direction at the Relativistic Heavy-Ion Collider at Brookhaven National Laboratory is presented. The midrapidity transverse energy density per participating nucleon rises steadily with the number of participants, closely paralleling the rise in charged-particle density, such that / remains relatively constant as a function of centrality. The energy density calculated via Bjorken's prescription for the 2% most central Au+Au collisions at square root[s(NN)] = 130 GeV is at least epsilon(Bj) = 4.6 GeV/fm(3), which is a factor of 1.6 larger than found at sqrt[s(NN)] = 17.2 GeV ( Pb+Pb at CERN).

Journal Article↗

Motor function and regulation of myosin X.

Myosin X is a member of the diverse myosin superfamily that is ubiquitously expressed in various mammalian tissues. Although its association with actin in cells has been shown, little is known about its biochemical and mechanoenzymatic function at the molecular level. We expressed bovine myosin X containing the entire head, neck, and coiled-coil domain and purified bovine myosin X in Sf9 cells. The Mg(2+)-ATPase activity of myosin X was significantly activated by actin with low K(ATP). The actin-activated ATPase activity was reduced at Ca(2+) concentrations above pCa 5 in which 1 mol of calmodulin light chain dissociates from the heavy chain. Myosin X translocates F-actin filaments with the velocity of 0.3 microm/s with the direction toward the barbed end. The actin translocating activity was inhibited at concentrations of Ca(2+) at pCa 6 in which no calmodulin dissociation takes place, suggesting that the calmodulin dissociation is not required for the inhibition of the motility. Unlike class V myosin, which shows a high affinity for F-actin in the presence of ATP, the K(actin) of the myosin X ATPase was much higher than that of myosin V. Consistently nearly all actin dissociated from myosin X in the presence of ATP. ADP did not significantly inhibit the actin-activated ATPase activity of myosin X, suggesting that the ADP release step is not rate-limiting. These results suggest that myosin X is a nonprocessive motor. Consistently myosin X failed to support the actin translocation at low density in an in vitro motility assay where myosin V, a processive motor, supports the actin filament movement.

Actins↗

Centrality dependence of charged particle multiplicity in Au-Au collisions at square root of (s)NN = 130 GeV.

We present results for the charged-particle multiplicity distribution at midrapidity in Au-Au collisions at square root of [s(NN)] = 130 GeV measured with the PHENIX detector at RHIC. For the 5% most central collisions we find dN(ch)/d eta(vertical line eta = 0) = 622+/-1(stat)+/-41(syst). The results, analyzed as a function of centrality, show a steady rise of the particle density per participating nucleon with centrality.

Journal Article↗

Staging of palpable T1-2 invasive breast cancer with helical CT.

BACKGROUND: The purpose of this study was to evaluate the accuracy of contrast-enhanced high resolution helical computed tomography (CT) for assessing locoregional staging of palpable T1-2 invasive breast cancer. METHODS: Helical CT studies of 156 lesions from 156 patients with invasive breast cancer before breast-conserving surgery were examined. A lesion was defined as positive if focal enhancement was detected by CT within 100 seconds after contrast material administration. After resection, tumors were histopathologically mapped and comparison made with the extent of contrast enhancement. RESULTS: Helical CT enabled detection of all 156 index tumors. CT enabled detection of 28 of 43 multifocal lesions (65%) and five of five multicentric lesions (100%). In 24 of 33 lesions (73%), CT revealed additional cancers not seen on mammography. The extent of tumor significantly correlated with CT measurements (r=0.76, p<0.0001). CONCLUSION: Helical CT of the breast is an accurate preoperative imaging modality for assessing the locoregional staging of T1-2 invasive breast cancer.

Adult↗

Morphometrical study of the arterial perforators of the deep inferior epigastric perforator flap.

Although abdominal perforator flaps based on a cutaneous branch of the deep inferior epigastric artery (DIEP flaps) have many advantages, preparing these flaps is technically difficult and requires great skill, especially as the portion of the artery running under the anterior rectus abdominis sheath must be operated upon "blind". To allow easier preparation and elevation of a DIEP flap pedicle, we propose that the arterial perforator should: 1) be more than 1.0 mm large; 2) run a straight intramuscular course, parallel to the rectus abdominis m. fibers, with no large muscular branches; and 3) have only a short portion running immediately under the anterior rectus abdominis sheath. We examined 329 perforators (more than 0.5 mm in diameter at the anterior sheath) in 66 rectus abdominis mm. from 33 cadavers among them: 1) 52 "large" perforators were over 1.0 mm in diameter; 2) 107 "suitable" perforators ran parallel to the muscle fibers without giving off large muscular branches; and 3) 35 "ideal" perforators combined these characteristics. The ideal perforators were usually located in the mid-abdominal region, 10-30 mm lateral to the umbilicus. The suitable perforators were usually present, often in combination with the ideal perforator(s), in a restricted area 20 mm cranial and 40-50 mm lateral to the umbilicus. We classified the course and ramification pattern of the deep inferior epigastric a. into six patterns, depending on whether the anastomosis was sited in the medial or lateral branch and the level at which the branches originated.

Aged↗