Method of reduction of the number of driving system channels for phased-array transducers using isolation transformers.

Phased-array technology offers an incredible advantage to therapeutic ultrasound due to the ability to electronically steer foci, create multiple foci, or to create an enlarged focal region by using phase cancellation. However, to take advantage of this flexibility, the phased-arrays generally consist of many elements. Each of these elements requires its own radio-frequency generator with independent amplitude and phase control, resulting in a large, complex, and expensive driving system. A method is presented here where in certain cases the number of amplifier channels can be reduced to a fraction of the number of transducer elements, thereby simplifying the driving system and reducing the overall system complexity and cost, by using isolation transformers to produce 180 degrees phase shifts.

Electric Impedance↗

Field characterization of therapeutic ultrasound phased arrays through forward and backward planar projection

Spatial planar projection techniques propagate field measurements from a single plane in front of a transmitter to arbitrary new planes closer to or further away from the source. A linear wave vector frequency-domain projection algorithm is applied to the acoustic fields measured from several focused transducer arrays designed for ultrasound therapy. A polyvinylidene difluoride hydrophone is first scanned in a water tank over a plane using a three-dimensional positioning system to measure the complex pressure field as a function of position. The field is then projected to a series of new planes using the algorithm. Results of the projected fields are compared with direct measurements taken at corresponding distances. Excellent correlation is found between the projected and measured data. The method is shown to be accurate for use with phase-controlled field patterns, providing a rapid and accurate method for obtaining field information over a large spatial volume. This method can significantly simplify the characterization procedure required for phased-array application used for therapy. Most significantly, the wavefront propagated back to a phased array can be used to predict the field produced by different phase and amplitude settings of the array elements. A field back-projected to the source could be used as an improved source function in acoustic modeling.

Journal Article↗

Transrectal ultrasound applicator for prostate heating monitored using MRI thermometry.

PURPOSE: For potential localized hyperthermia treatment of tumors within the prostate, an ultrasound applicator consisting entirely of nonmagnetic materials for use with magnetic resonance imaging (MRI) has been developed and tested on muscle tissue ex vivo and in vivo. METHODS AND MATERIALS: A partial-cylindrical intracavitary transducer consisting of 16 elements in a 4 x 4 pattern was constructed. It produced a radially propagating acoustic pressure field. Each element of this array (1.5 x 0.75 cm), operating at 1.5 MHz, could be separately powered to produce a desired energy deposition pattern within a target volume. Spatial and temporal temperature elevations were determined using the temperature-dependent proton resonant frequency (PRF) shift and phase subtraction of MR images acquired during ultrasonic heating. Four rabbits were exposed to the ultrasound to raise the local tissue temperature to 45 degrees C for 25 minutes. Six experiments compared thermocouple temperature results to PRF shift temperature results. RESULTS: The tests showed that the multi-element ultrasound applicator was MRI-compatible and allowed imaging during sonication. The induced temperature distribution could be controlled by monitoring the RF power to each transducer element. Therapeutic temperature elevations were easily achieved in vivo at power levels that were about 16% of the maximum system power. From the six thermocouple experiments, comparison between the thermocouple temperature and the PRF temperature yielded an average error of 0.34+/-0.36 degrees C. CONCLUSIONS: The MRI-compatible intracavitary applicator and driving system was able to control the ultrasound field and temperature pattern in vivo. MRI thermometry using the PRF shift can provide adequate temperature accuracy and stability for controlling the temperature distribution.

Animals↗

Ultrasound technology for hyperthermia.

Hyperthermia (HT) is used in the clinical management of cancer and benign disease. Numerous biological and clinical investigations have demonstrated that HT in the 41-45 degrees C range can significantly enhance clinical responses to radiation therapy, and has potential for enhancing other therapies, such as chemotherapy, immunotherapy and gene therapy. Furthermore, high-temperature hyperthermia (greater than 50 degrees C) alone is being used for selective tissue destruction as an alternative to conventional invasive surgery. The degree of thermal enhancement of these therapies is strongly dependent on the ability to localize and maintain therapeutic temperature elevations. Due to the often heterogeneous and dynamic properties of tissues, most notably blood perfusion and the presence of thermally significant blood vessels, therapeutic temperature elevations are difficult to spatially and temporally control during these forms of HT therapy. However, ultrasound technology has significant advantages that allow for a higher degree of spatial and dynamic control of the heating compared to other commonly utilized heating modalities. These advantages include a favorable range of energy penetration characteristics in soft tissue and the ability to shape the energy deposition patterns. Thus, heating systems have been developed for interstitial, intracavitary, or external approaches that utilize properties such as multiple transducer arrays, phased arrays, focused beams, mechanical and/or electrical scanning, dynamic frequency control and transducers of various shapes and sizes. This article provides a general review of a selection of ultrasound hyperthermia systems that are either in clinical use or currently under development, that utilize these advantages as a means to better localize and control HT for the aforementioned therapies.

Equipment Design↗

In vivo demonstration of noninvasive thermal surgery of the liver and kidney using an ultrasonic phased array.

A 256-element, continuous-wave ultrasonic phased array has been used to thermally coagulate deep-seated liver and kidney tissue. The array elements were formed on a 1-3 piezocomposite bowl with a 10-cm radius of curvature and 12-cm diameter. The 0.65 x 0.65 cm2 projection elements were driven at 1.1 MHz by a custom-built amplifier system. A series of in vivo porcine experiments demonstrated the ability to coagulate liver and kidney tissue using the large-scale phased array. The temperature response of the treatment was guided and monitored using magnetic resonance (MR) images. Focal lesion volumes greater than 0.5 cm3 in kidney and 2 cm3 in liver were formed from a single 20-s sonication.

Animals↗

Theoretical design of a spherically sectioned phased array for ultrasound surgery of the liver.

GOAL: The theoretical explanation of the limits of an array transducer to coagulate large tissues volumes. METHODS: A theoretical model is used to illustrate the focal limitations of a spherically sectioned array designed for the treatment of deep seated tissue, e.g. liver. The design optimizes the acoustic dose as a function of the focal depth and available acoustic aperture with the goal of coagulating large volumes in a single sonication period. A quantitative measure of the possible region of focal necrosis is modeled as a function of array parameters with the limiting criteria being near field heating and patient pain. RESULTS: Acoustic simulations show that the maximum distance to produce continuous necrosis between foci in a multiple focus pattern and in a temporally multiplexed pattern is approximately 50% larger than the distance needed between sequential foci. CONCLUSION: Multiple focus patterns or rapidly scanned single foci are significantly advantageous to sequential sonications of a single focus transducer.

Algorithms↗

Magnetic resonance imaging-guided focused ultrasound synovectomy.

OBJECTIVE: To investigate the feasibility of magnetic resonance imaging (MRI)-guided high power focused ultrasound (FUS) to perform synovectomy noninvasively. METHODS: Five New Zealand white male rabbit knees with experimentally induced arthritis underwent MRI-guided thermal surgery by high power (60 W/10 s) sonication. Evidence of tissue coagulation was monitored during the procedure and confirmed by gross and microscopic evaluation and MRI. RESULTS: Partial synovectomy was performed in five animals. Necrotized synovial tissue was observed on gross and microscopic evaluation. Visible signal intensity alterations including high signal intensity on T2-weighted (T2W) images and lack of contrast-enhancement on T1-weighted (T1W) post-contrast, post-sonication images were characteristic and reproducible. CONCLUSION: Our results demonstrate the ability of high power sonication to destroy synovial tissue in vivo.

Animals↗

Low-profile lenses for ultrasound surgery.

Several flat lens designs have been simulated that focus a planar transducer at various depths and angular deflections. The use of flat lenses with planar phased arrays to create multiple focus patterns has also been explored. The simulations have shown that the discrete element size is practical to machine. Simulations predict that a flat polystyrene lens with an f number of 1.0 can produce a focal peak intensity that is 80% that of a geometrically focused transducer with the same focal depth, including the attenuation through the lens, by utilizing four discrete phase steps. These predictions were verified with a simplified experimental lens utilizing only two phase steps. Simulations predicted an attenuation within the lens of 18% and a focal peak intensity of 38%. Measurements resulted in an attenuation of 30% and a focal peak intensity of 30%. Experimental lens studies have indicated that sufficient power can be transmitted through the lenses for these designs to be feasible for use in ultrasound surgery.

Computer Simulation↗

Arrays of multielement ultrasound applicators for interstitial hyperthermia.

Arrays of multielement ultrasound applicators for interstitial hyperthermia have been developed and tested both in vitro and in vivo. The system includes multielement applicators, a 64 channel RF driving unit, a power measuring unit, a 112 channel multisensor temperature measuring unit, and a water cooling unit. Ninety-five arrays of single-element and nine arrays of three-element ultrasound applicators were designed, built, and characterized by measuring transducer efficiency and ultrasound field distribution. Improved uniformity in the azimuthal direction was achieved by using multiple driving frequencies. In addition, production of ultrasound in a desired sector of the transducer was possible by selecting a suitable frequency. Both in vitro and in vivo experiments showed that 92% of monitored temperature points within the target volume of 30 mm x 30 mm x 35 mm achieved a therapeutic temperature rise (above 5 degrees C) when an array of five three-element applicators were used. These results indicated that the arrays of multielement ultrasound applicators have distinct advantages over present interstitial hyperthermia modalities in terms of the capability to control the temperature distribution with a large catheter spacing. As a conclusion, the feasibility of a practical arrays of multielement ultrasound applicators for interstitial hyperthermia was demonstrated.

Animals↗

Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging.

Magnetic resonance imaging (MRI) thermometry has been utilized for in vivo evaluation of thermal exposure induced by a focused ultrasound beam. A simulation study of the focused ultrasound beam was conducted to select imaging parameters for reducing the error due to the spatial and temporal averaging of MRI. Temperature imaging based on the proton resonance frequency shift was utilized to obtain the temperature distribution during sonication in the skeletal muscle of eight rabbits. MRI-derived temperature information was then used to calculate the thermal dose distribution induced by the sonication and to estimate the coagulated tissue volume. The tissue changes were also evaluated directly by taking the T2-weighted and the contrast agent enhanced T1-weighted MR images. Errors in the temperature and thermal dose measurements were found to be minimal using the following parameters: slice thickness = 3 mm, voxel dimension = 0.6 mm, and scan time per image = 3.4 s. The estimated dimensions of the coagulated tissue volume were in good agreement with the tissue damages seen on the contrast agent enhanced T1-weighted images. The tissue damage seen on the histology was closely matched to the ones seen on the T2-weighted images. This study showed that MRI thermometry has significant potential for both monitoring the thermal exposure and evaluating the tissue damage. This would allow real-time control of the sonication parameters to optimize clinical treatments.

Animals↗

The potential of transskull ultrasound therapy and surgery using the maximum available skull surface area.

Based on previous studies, the transskull ultrasound field is re-examined by utilizing the maximum available skull surface area. The source is assumed to be in direct contact with the skull outer surface, and phase correction is adopted to obtain a sharp focus at a desired location. A digitized skull profile was obtained from Magnetic Resonance (MR) scan images of a volunteer. Two driving frequencies (0.5 and 1.0 MHz) within the appropriate frequency range for transskull ultrasound therapy and surgery are investigated. With no phase correction, there is no apparent transskull focus. With phase correction, a sharp transskull focus is obtained at the desired location. Both pressure and specific absorption rate (SAR) gains (ratios of pressure amplitude and SAR at the focal point compared to those on the outer skull surface) are examined, and it is shown that the skull heating problem can be overcome by utilizing the maximum available skull surface area. By specifying the phase correction for different locations, the focus can be successfully moved inside the deep brain volume without significantly compromising the pressure and SAR gains; however, the sidelobes may be of concern at superficial sites.

Humans↗

Open-configuration MR imaging, intervention, and surgery of the urinary tract.

The open-configuration MR imaging system provides new applications both in diagnosis and in therapy of conditions in the urinary tract. In addition to conventional imaging, the open configuration permits MR imaging of patients in many positions. This has already been shown to be useful in imaging the pelvis during voiding, where a sitting position allows urodynamic evaluation. The lithotomy position can be used for imaging the prostate, which also permits procedural access. The ultimate purpose of the interventional MR imaging suite is to integrate therapeutic tools and techniques with MR imaging. From surgical planning through specialized imaging systems with minimally invasive surgical applications, new methods are being developed and implemented. This new field of image-guided therapy will require extensive clinical development and evaluation for applications in the urinary tract. This will require a large concentrated interdisciplinary effort of surgeons, radiologists, computer scientists, engineers, and physicists. Successful integration of basic research and clinical work will result in a number of cutting-edge technologies with direct clinical application in the urinary tract. Initial projects have included biopsies, endoscopies, and real-time procedural control of high-temperature and cryogenic ablations. It is anticipated that the current surge in image-guided interventions will motivate even more research activity in this field, and will ultimately define the role of MR imaging guidance in urologic intervention and surgery.

Animals↗

Demonstration of potential noninvasive ultrasound brain therapy through an intact skull.

Utilization of therapeutic ultrasound in the brain has been seriously limited by the commonly accepted view that these exposures would require that a piece of the skull bone be removed to allow the ultrasound beam to propagate into the brain. In this paper, the feasibility of delivering ultrasound therapy through the intact skull was studied. Sonications were performed through a piece of human skull with focused transducers at 0.248, 0.559, 1.0 and 1.68 MHz. The skull attenuated and distorted the field; however, a sharp focal spot was created at frequencies of 1 MHz or lower. At the higher frequency, the focus was destroyed. To investigate the feasibility of compensating for the ultrasound field distortion caused by the bone, phased array experiments were performed. Two arrays with 64 elements, operating at 0.6 MHz and 1.58 MHz, were used in these experiments. The phase shifts caused by the skull were measured for each element of the arrays and then compensated for by phase-control circuitry. These phase corrections allowed a sharp focus to be generated at both frequencies. Finally, tissue destruction was induced by using pulsed sonication through a piece of human skull in a rabbit brain in vivo at the frequency of 0.559 MHz. In summary, the results showed that transcranial delivery of therapeutic ultrasound into the brain may be feasible.

Animals↗

The feasibility of using focused ultrasound for transmyocardial revascularization.

Transmyocardial laser revascularization (TMR) is used for improving the blood supply to damaged myocardium due to advanced heart disease. We hypothesize that focused ultrasound can be used to generate channels through the cardiac muscle by vaporizing the tissue at the focal spot. The purpose of this study was to evaluate the effects of varying the ultrasound exposure parameters (frequency, amplitude, pulse period, duty cycle, focal depth and exposure time) on the vaporized tissue size and to determine the feasibility of using ultrasound for creating cavities and/or channels in the left ventricular wall for transmyocardial revascularization. Based on in vitro experiments using bovine myocardium, the experiments indicate that a 1 mm diameter channel could be created by using, for example, a focused transducer with a diameter of 10 cm and a radius of curvature of 8 cm operating at a frequency of 2.52 MHz. The required spatial peak intensity during the 0.5-s sonications was found to be 2300 W/cm2 with a pulse repetition period of 40 ms and a 50% duty cycle. These parameters have been used to create cavities during in vivo tests using canine myocardium. The results demonstrated that ultrasound could be used to create small channels through myocardium. The most important potential for ultrasound is its ability to generate these channels completely noninvasively.

Animals↗

Intracavitary ultrasound phased arrays for prostate thermal therapies: MRI compatibility and in vivo testing.

A 62 element MRI-compatible linear phased array was designed and constructed to investigate the feasibility of using transrectal ultrasound for the thermal therapeutic treatment of prostate cancer and benign prostatic hyperplasia. An aperiodic design technique developed in a previous study was used in the design of this array, which resulted in reduced grating lobe levels by using an optimized random distribution of unequally sized elements. The element sizes used in this array were selected to be favorable for both grating lobe levels as determined by array aperiodicity and array efficiency as determined by width to thickness ratios. The heating capabilities and MRI compatibility of the array were tested with in vivo rabbit thigh muscle heating experiments using MRI temperature monitoring. The array produced therapeutic temperature elevations in vivo at depths of 3-6 cm and axial locations up to 3 cm off the central axis and increased the size of the heated volume with electronic scanning of a single focus. The ability of this array to be used for ultrasound surgery was demonstrated by creating necrosed tissue lesions in vivo using short high-power sonications. The ability of the array to be used for hyperthermia was demonstrated by inducing therapeutic temperature elevations for longer exposures. Based on the acoustic and heating performance of this array, it has the potential to be clinically useful for delivering thermal therapies to the prostate and other target volumes close to body cavities.

Acoustics↗

Focusing of therapeutic ultrasound through a human skull: a numerical study.

A numerical model was developed which can use digitized layer interfaces to calculate ultrasound wave absorption, diffraction, reflection, and refraction. This model was used to evaluate the feasibility of ultrasound therapy and surgery through a human skull. A digitized human skull profile was obtained from magnetic resonance (MR) images and used to calculate the ultrasound field in the brain of a volunteer from a spherically curved phased array. With no phase correction, the focus of the array was shifted and defocused. The phased array technique was used to correct focal shift, reduce side lobes, and enhance focal amplitude. The optimum source element width was estimated for each frequency to obtain a near optimium focus, and an appropriate frequency range for transskull ultrasound therapy and surgery was determined. Acoustic pressure amplitude on the skull surfaces was examined, and it was shown that the skull heating problem could be overcome. Despite high attenuation, complex interface shape, and nonuniform thickness of a human skull, a sharply focused transskull ultrasound field can be generated for noninvasive ultrasound therapy and surgery in the brain.

Humans↗

Temperature mapping using the water proton chemical shift: a chemical shift selective phase mapping method.

A proton-chemical-shift-based temperature imaging method, called chemical shift selective phase mapping, is proposed. The technique uses frequency-selective suppression to provide frequency selectivity to the phase mapping method. Separate imaging of the phase distributions of the water and nonwater signals reduced the error due to the presence of a nonwater signal in measuring the water proton chemical shift change in two-component samples. Imaging of the phase difference between water and oil yielded an internally referenced water proton chemical shift measurement to visualize the temperature change distribution, which was unaffected by motion-induced susceptibility changes.

Animals↗

Design and experimental verification of thin acoustic lenses for the coagulation of large tissue volumes.

Large focal volumes are desired in ultrasound surgery to reduce the total treatment time when large tumours are thermally coagulated. Phased arrays are capable of producing enlarged focal volumes in addition to providing the ability for on-line modification of focal shape and location. Although phased arrays have several advantages over their non-phased counterparts, the complexity of these arrays also presents some disadvantages regarding cost and complexity. One less costly alternative is the use of thin acoustic lenses to alter the field shape of a single-focus transducer. Four polystyrene lenses have been designed using the sector-vortex principle developed for phased arrays by Cain and Umemura. Measurements of the acoustic fields produced with the lenses are in good agreement with the simulated fields. The transmission measurements through each of the four lenses ranged from 76% to 84%, and over 52 W of total acoustic power has been delivered through each of the lenses during in vivo experiments without any damage to the lenses or the transducer. The in vivo results showed an increase in rate of necrosis to 10.1 +/- 1.4 cm3 h-1 using the mode 4 lens, or 5.2 +/- 0.7 times higher than the focused transducer alone.

Acoustic Stimulation↗