K J Anusavice

Publications and source records attributed to K J Anusavice.

At least 19 recordsLinked to original sources

Influence of pH and oxygen-inhibited layer on fluoride release properties of fluoride sealant.

OBJECTIVES: This study tested the hypothesis that the oxygen-inhibited layer on a light-cured methacrylate based resin and the pH of the storage medium would increase significantly the initial fluoride release and long-term release rate from fluoride dental sealant. METHODS: Forty-eight discs (16-mm diameter x 1-mm thick) were made from FluroShield (<5 wt% NaF) and Helioseal F (<30 wt% fluorosilicate glass) sealants. For each sealant, 24 discs were cured through a Mylar strip that covered the surface and the remaining 24 discs were cured in air allowing formation of the oxygen-inhibited surface. Each specimen in the 24-disc groups was stored individually in 25-mL vials, and divided into four six-vial groups to receive 10 mL of pH4-pH7 (designation of pH 4-7) lactate buffer solutions. The buffer solutions were replaced periodically up to 121 days. The cumulative fluoride release over time was used to determine the coefficients for short-term and long-term release. RESULTS: Two-way ANOVA showed that the mean coefficient values for either sealant were significantly influenced by the curing condition (p<0.0001) and pH (p<0.0001), except for short-term release from NaF sealant. The duration of short-term release was much longer for the fluorosilicate glass sealant. CONCLUSIONS: Both pH and the source of fluoride source incorporated in the sealant play significant roles in fluoride release.

Bisphenol A-Glycidyl Methacrylate↗

Fracture surface analysis of clinically failed fixed partial dentures.

Ceramic systems have limited long-term fracture resistance, especially when they are used in posterior areas or for fixed partial dentures. The objective of this study was to determine the site of crack initiation and the causes of fracture of clinically failed ceramic fixed partial dentures. Six Empress 2 lithia-disilicate (Li(2)O x 2SiO(2))-based veneered bridges and 7 experimental lithia-disilicate-based non-veneered ceramic bridges were retrieved and analyzed. Fractography and fracture mechanics methods were used to estimate the stresses at failure in 6 bridges (50%) whose fracture initiated from the occlusal surface of the connectors. Fracture of 1 non-veneered bridge (8%) initiated within the gingival surface of the connector. Three veneered bridges fractured within the veneer layers. Failure stresses of the all-core fixed partial dentures ranged from 107 to 161 MPa. Failure stresses of the veneered fixed partial dentures ranged from 19 to 68 MPa. We conclude that fracture initiation sites are controlled primarily by contact damage.

Compressive Strength↗

Controlled release of chlorhexidine from UDMA-TEGDMA resin.

Chlorhexidine salts are available in various formulations for dental applications. This study tested the hypothesis that the release of chlorhexidine from a urethane dimethacrylate and triethylene glycol dimethacrylate resin system can be effectively controlled by the chlorhexidine diacetate content and pH. The filler concentrations were 9.1, 23.1, or 33.3 wt%, and the filled resins were exposed to pH 4 and pH 6 acetate buffers. The results showed that Fickian diffusion was the dominant release mechanism. The rates of release were significantly higher in pH 4 buffer, which was attributed to the increase of chlorhexidine diacetate solubility at lower pH. The higher level of filler loading reduced the degree of polymerization, leading to a greater loss of organic components and higher chlorhexidine release rates.

Chlorhexidine↗

Apparent interfacial fracture toughness of resin/ceramic systems.

We suggest that the apparent interfacial fracture toughness (K(A)) may be estimated by fracture mechanics and fractography. This study tested the hypothesis that the K(A) of the adhesion zone of resin/ceramic systems is affected by the ceramic microstructure. Lithia disilicate-based (Empress2-E2) and leucite-based (Empress-E1) ceramics were surface-treated with hydrofluoric acid (HF) and/or silane (S), followed by an adhesive resin. Microtensile test specimens (n = 30; area of 1 +/- 0.01 mm(2)) were indented (9.8 N) at the interface and loaded to failure in tension. We used tensile strength (sigma) and the critical crack size (c) to calculate K(A) (K(A) = Ysigmac(1/2)) (Y = 1.65). ANOVA and Weibull analyses were used for statistical analyses. Mean K(A) (MPa.m(1/2)) values were: (E1HF) 0.26 +/- 0.06; (E1S) 0.23 +/- 0.06; (E1HFS) 0.30 +/- 0.06; (E2HF) 0.31 +/- 0.06; (E2S) 0.13 +/- 0.05; and (E2HFS) 0.41 +/- 0.07. All fractures originated from indentation sites. Estimation of interfacial toughness was feasible by fracture mechanics and fractography. The K(A) for the systems tested was affected by the ceramic microstructure and surface treatment.

Acid Etching, Dental↗

Effect of CaF2 content on rate of fluoride release from filled resins.

Information on the time-dependent release of fluoride from filled resins containing fluoride particles as a function of particle content and solution pH is limited. This study characterized the fluoride ion release from filled resins containing CaF2 particles as a function of filler content and pH. Urethane dimethacrylate and triethylene glycol dimethacrylate resins were used to make filled-resin disks containing 9.09, 23.08, or 33.33 mass% CaF2 filler. Fluoride ion release for the 9.09 mass% concentration was independent of pH. Increasing the filler content from 9.09 to 33.33 mass% increased the fluoride release rate in pH 4.0 buffer solution, because of greater surface degradation. Fluoride ion release from disks stored in pH 6.0 buffer solutions occurred mainly by diffusion from disk surfaces, while fluoride release from disks in pH 4.0 buffers was controlled by diffusion from disk surfaces and degeneration of the resin matrix, which exposed more CaF2 particle surface area.

Calcium Fluoride↗

Informatics systems to assess and apply clinical research on dental restorative materials.

Dental biomaterials are used clinically for one or more of the following purposes: to restore function, to enhance esthetics, and to prevent or arrest demineralization of tooth structure. Studies of the clinical performance of restorations and prostheses made from these materials have generally focused on quality assessment and survival statistics. Data from these studies should provide probabilities of specific treatment outcomes that are useful for practicing dentists. However, the utility of these data is limited by the lack of national and international standards for assessing these clinical outcomes. Standardized approaches toward clinical informatics and treatment-decision analysis are urgently needed to minimize the variability of clinical outcomes reported in publications associated with direct and indirect restorative materials used for dental restorations and prostheses.

Clinical Trials as Topic↗

Influence of connector design on fracture probability of ceramic fixed-partial dentures.

Fracture of ceramic fixed-partial dentures (FPDs) tends to occur in the connector area because of stress concentrations. The objective of this study was to test the hypothesis that the radius of curvature at the gingival embrasure of the FPD connector significantly affects the fracture resistance of three-unit FPDs. Two three-dimensional finite element models (FEMs), representing two FPD connector designs, were created in a manner corresponding to that described in a previous experimental study (Oh, 2002). We performed fractographic analysis and FEM analyses based on CARES (NASA) post-processing software to determine the crack initiation site as well as to predict the characteristic strength, the location of peak stress concentrations, and the risk-of-rupture intensities. A good correlation was found between the experimentally measured failure loads and those predicted by FEM simulation analyses. Fractography revealed fracture initiation at the gingival embrasure, which confirms the numerically predicted fracture initiation site. For the designs tested, the radius of curvature at the gingival embrasure strongly affects the fracture resistance of FPDs.

Ceramics↗

Is it time to change state and regional dental licensure board exams in response to evidence from caries research?

State and regional board exams represent the final gateway to dental licensure. One would expect that the requirements for licensure would reflect procedures that are beneficial to each patient's oral health and that are consistent with the teachings of most dental schools. We conducted an Internet survey to determine whether Class 2 tooth preparations based on caries lesions whose radiolucencies were confined to enamel were allowed for state and regional exams. Information obtained for 46 of the 50 states revealed that 33 of the states (72%) allowed teeth with either an E1 or E2 lesion to be restored. Seventeen of these states allowed teeth with an E1 lesion to be restored. Only 12 of the 46 states (26%) covered by these boards did not allow teeth with E1 or E2 lesions to be surgically treated. In contrast, a recent report indicates that only 30% of dental schools permit teeth with enamel lesions to be restored to satisfy clinical requirements and competencies.

Clinical Competence↗

Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics.

OBJECTIVES: The objective of this study was to test the hypothesis that industrially manufactured ceramic materials, such as Cerec Mark II and Zirconia-TZP, have a smaller range of fracture strength variation and therefore greater structural reliability than laboratory-processed dental ceramic materials. METHODS: Thirty bar specimens per material were prepared and tested. The four-point bend test was used to determine the flexure strength of all ceramic materials. The fracture stress values were analyzed by Weibull analysis to determine the Weibull modulus values (m) and the 1 and 5% probabilities of failure. RESULTS: The mean strength and standard deviation values for these ceramics are as follows: (MPa+/-SD) were: Cerec Mark II, 86.3+/-4.3; Dicor, 70.3+/-12.2; In-Ceram Alumina, 429. 3+/-87.2; IPS Empress, 83.9+/-11.3; Vitadur Alpha Core, 131.0+/-9.5; Vitadur Alpha Dentin, 60.7+/-6.8; Vita VMK 68, 82.7+/-10.0; and Zirconia-TZP, 913.0+/-50.2. There was no statistically significant difference among the flexure strength of Cerec Mark II, Dicor, IPS Empress, Vitadur Alpha Dentin, and Vita VMK 68 ceramics (p>0.05). The highest Weibull moduli were associated with Cerec Mark II and Zirconia-TZP ceramics (23.6 and 18.4). Dicor glass-ceramic and In-Ceram Alumina had the lowest m values (5.5 and 5.7), whereas intermediate values were observed for IPS-Empress, Vita VMK 68, Vitadur Alpha Dentin and Vitadur Alpha Core ceramics (8.6, 8.9, 10.0 and 13.0, respectively). CONCLUSIONS: Except for In-Ceram Alumina, Vitadur Alpha and Zirconia-TZP core ceramics, most of the investigated ceramic materials fabricated under the condition of a dental laboratory were not stronger or more structurally reliable than Vita VMK 68 veneering porcelain. Only Cerec Mark II and Zirconia-TZP specimens, which were prepared from an industrially optimized ceramic material, exhibited m values greater than 18. Hence, we conclude that industrially prepared ceramics are more structurally reliable materials for dental applications although CAD-CAM procedures may induce surface and subsurface flaws that may adversely affect this property.

Aluminum Oxide↗

Minimal intervention dentistry--a review. FDI Commission Project 1-97.

The concept of minimal intervention dentistry has evolved as a consequence of our increased understanding of the caries process and the development of adhesive restorative materials. It is now recognised that demineralised but noncavitated enamel and dentine can be 'healed', and that the surgical approach to the treatment of a caries lesion along with 'extension for prevention' as proposed by G V Black is no longer tenable. This paper gives an overview of the concepts of minimal intervention dentistry, describes suggested techniques for a minimally invasive operative approach, and reviews clinical studies which have been carried out in this area.

Composite Resins↗

Crack initiation modes in bilayered alumina/porcelain disks as a function of core/veneer thickness ratio and supporting substrate stiffness.

We hypothesize that the fracture resistance of alumina core/porcelain veneer disks increases and that crack initiation shifts from veneer to core as the core/veneer thickness ratio (t(C)/t(V)) increases from 0.5/1.0 to 1.3/0.2, or as the elastic modulus of the supporting substrate (E(S)) to which it is resin-bonded increases from 5.1 to 226 GPa. When supported by a low-modulus substrate, disks with low t(C)/t(V) ratios exhibited cracks in the veneer and within the core, while those with high t(C)/t(V) ratios demonstrated core cracks, but not veneer cracks. None of the disks supported by Ni-Cr alloy (E = 226 GPa) exhibited core cracks. These results support the hypothesis that the crack initiation site shifts as the t(C)/t(V) ratio increases, but the increase in E(S) did not affect the crack initiation site. This study suggests that the t(C)/t(V) ratio is the dominant factor that controls the failure initiation site in bilayered ceramic disks.

Aluminum Oxide↗

Ceramic design concepts based on stress distribution analysis.

This article discusses general design concepts involved in fabricating ceramic and metal-ceramic restorations based on scientific stress distribution data. These include the effects of ceramic layer thickness, modulus of elasticity of supporting substrates, direction of applied loads, intraoral stress, and crown geometry on the susceptibility of certain restoration designs to fracture.

Ceramics↗

Microtensile strength of composite bonded to hot-pressed ceramics.

PURPOSE: The objective of this in vitro study employing the microtensile test was to test the hypothesis that the tensile bond strength of hot-pressed ceramics to composite is controlled by the ceramic microstructure and the ceramic surface treatment. MATERIALS AND METHODS: Hot-pressed IPS Empress (E1) and IPS Empress 2 (E2) ceramic blocks were polished with 1-micron alumina abrasive and treated as follows: group 1: 9.6% hydrofluoric acid (HF) on E1; group 2: 4% acidulated phosphate fluoride (APF) on E1; group 3: silane (S) on E1; group 4: HF + S on E1; group 5: APF + S on E1; group 6: HF on E2; group 7: APF on E2; group 8: S on E2; group 9: HF + S on E2; group 10: APF + S on E2. The surfaces as described above were then treated with Scotchbond Multi-Purpose Plus and covered with composite (Z-100). From the blocks obtained in this manner, specimens for microtensile testing were created by sectioning. Twenty bar specimens for each group were loaded to failure under tension using an Instron testing machine. RESULTS: Mean tensile bond strength (MPa) and standard deviation values are as follows: (1) 9.9 +/- 1.2; (2) 0; (3) 27.2 +/- 4.8; (4) 20.6 +/- 3.0; (5) 13.6 +/- 4.5; (6) 41.7 +/- 6.7; (7) 19.1 +/- 2.6; (8) 30.1 +/- 5.3; (9) 56.1 +/- 4.1; (10) 36.9 +/- 3.9. All fractures occurred within the adhesion zone. SEM images of chemically etched specimens revealed that HF produced greater surface degradation and greater bond strength than APF for both E1 and E2 ceramics. The mean bond strength of groups 6 through 10 (E2) was significantly greater than that of groups 1 through 5 (E1) for each treatment condition. CONCLUSION: The tensile fracture resistance of the composite-ceramic adhesion zones is controlled primarily by ceramic microstructure and ceramic surface treatment.

Acid Etching, Dental↗

Does ART have a place in preservative dentistry?

The ART technique consists of hand excavating carious tissue and placing a highly viscous glass ionomer cement as a restoration material and as a sealant. Although the results of several studies are promising, the retention rates of these restorations for primary teeth are not impressive. Materials and methods that yield greater success rates are needed to improve long-term caries management outcomes. In principle, ART should yield outcomes similar to those associated with preservative dentistry, including the potential for minimal surgical intervention, conservation of sound tooth structure, avoidance of pain and need for local anesthetic injections, reduced risk for subsequent endodontics and tooth extraction, and increased survival time of the affected teeth. The ideal direct-filling ART material would be biocompatible and tooth colored; "forgiving" in its handling properties; insensitive to moisture or desiccation; hardenable without special equipment; able to form stable bonds to enamel and dentin; able to seal marginal gaps against bacteria; capable of releasing fluoride or remineralization and antibacterial agents when demineralization is most likely; and resistant to chemical attack. The highly viscous glass ionomer materials currently used for ART meet several of this criteria, though they may be deficient in their ability to seal marginal gaps against bacteria and in their sensitivity to desiccation. Furthermore, although they release fluoride over the lifetime of the restoration, this fluoride release alone may not prevent caries progression in all cases. It is necessary for cases of high caries risk to use chlorhexidine in conjunction with fluoride to achieve caries arrest and remineralization of adjacent areas of the affected teeth. Thus, while the ART technique offers some benefits in restoring function and reducing the rate of caries progression, it is unlikely that current materials will be able to arrest caries progression completely in high-risk persons.

Dental Caries↗

Thermal incompatibility analysis of metal-ceramic systems based on flexural displacement data.

The feasibility of simple tests or analytical methods for prediction of residual stress states in metal-ceramic (MC) prostheses has not been demonstrated. Biomaterial metal-ceramic strips have been proposed to provide sensitive measures of transient and residual stress states through the measurement of midpoint deflection after cooling from the ceramic sintering temperature. The objective of this study was to apply the elastic-viscoelastic analogy to calculate transient and residual midpoint deflections in MC biomaterial strips and to compare these values with deflections measured with a beam-bending viscometer (BBV). Calculations and measurements were made for five MC systems that were found from a clinical study to be "thermally compatible" systems. Metal strips, 64 mm in length, 3 mm wide, and either 0.5 mm, 1.0 mm, or 2.0 mm in thickness, were veneered with four 0.25-mm thick layers of opaque porcelain. Midpoint deflection of the MC strips (ceramic oriented in the posterior position) was measured during cooling from an initial temperature of 700 degrees C. In general, the directions of the measured residual deflections did not agree with the "textbook" convention that negative deflections are associated with positive thermal contraction mismatch (alpha(M) - alpha(c) > 0) regardless of metal thickness. For a metal thickness of 0.5 mm, the residual midpoint deflection for all thermal contraction mismatch cases, except one, was positive (upward deflection) whereas the residual midpoint deflections were all negative when the metal thickness was increased to 1 or 2 mm, independent of the thermal contraction mismatch. The best agreement between calculated and measured values of residual midpoint deflection (+16 microns vs. +14 +/- 2.3 microns, respectively was obtained for MC biomaterial strips with a Ni-Cr alloy (0.5 mm thick) while the largest difference (+346 microns vs. +61 +/- 43.8 microns) was obtained for MC bimaterial strips with a Au-Pd allow (0.5 mm thick). In all but one case, changes in deflection direction as a function of metal thickness were correctly predicted by the viscoelastic analysis. The results of this study indicate that a viscoelastic model is useful for estimating thermal compatibility conditions of MC systems.

Biocompatible Materials↗

Viscoelastic stress analysis of thermally compatible and incompatible metal-ceramic systems.

OBJECTIVE: The purpose of this study was to analyze transient and residual midpoint deflections and stresses in metal-opaque porcelain-body porcelain systems with matched and mismatched thermal contraction coefficients. METHODS: Calculations and measurements were made for seven trimaterial strips that covered a wide range of thermal contraction mismatches among constituent materials. Midpoint deflections were measured in a beam-bending viscometer during slow cooling from an initial temperature of 700 degrees C. Linear regression analysis with a correlation coefficient of 0.950 was used to compare measured and calculated residual midpoint deflections. Stress relaxation data were fit to a three-term exponential series by nonlinear regression analyses with correlation ratios ranging from 0.9972 to 0.9999. RESULTS: While finite element analyses correctly predicted the general shape of the deflection behavior as a function of temperature for all combinations, the best agreement between measured mean residual midpoint deflections and calculated values (+250 microns vs. +268 microns) was obtained for strips composed of a Au-Pd alloy (alpha m = 13.5 ppm/ degree C) with a medium expansion opaque porcelain (alpha o = 13.3 ppm/degree C) and a high expansion body porcelain (alpha B = 14.4 ppm/degree C). The highest calculated residual tensile stress of +26 MPa at the surface of body porcelain was associated with the 0.5-mm-thick Ni-Cr-Be alloy strip (alpha m = 15.1 ppm/degree C) with medium expansion porcelains (alpha o = 13.5 ppm/degree C and alpha B = 13.9 ppm/degree C). The smallest measured residual deflection (+10 microns) was also associated with this combination. The results of this study indicated that metal-ceramic strips are sensitive indicators of stress development caused by a thermal contraction mismatch; however, the magnitudes of the residual deflections do not necessarily correlate with the stress magnitudes in the ceramic. SIGNIFICANCE: Currently there are no U.S. or international standards that define the maximum difference in thermal contraction coefficients that can exist between a metal and its ceramic veneer without causing transient failures of ceramic during cooling or delayed failures in ceramic because of high residual tensile stresses. The present research represents a major step in understanding the various factors that influence the development of transient and residual stresses. A knowledge of the effects of process variables on stress development is necessary for selection of potentially successful metal-ceramic systems and for optimizing the design of dental prostheses.

Aluminum Oxide↗

Chemical durability of Dicor and fluorocanasite-based glass-ceramics.

Fluorocanasite (Al2O3-CaO-F-K2O-Na2O-SiO2) glass-ceramics exhibit fracture toughness values of up to 5.0 MPa x m1/2. However, their chemical durability is not adequate for dental applications. The objective of this study was to test the hypothesis that an increased concentration of Al2O3 can increase the chemical durability of fluorocanasite-based glass-ceramics. Glass frits containing 2 wt% (CAN2), 5 wt% (CAN5), and 10 wt% Al2O3 (CAN10) were melted individually, poured into a graphite mold, and cut into 16-mm-diam. x 2-mm-thick disks. Each disk was crystallized at 850 degrees C for 6 hrs. The disks were immersed in a solution of de-ionized-distilled water, 4% acetic acid, or a pH 1 buffer solution, and sealed in 90-mL Teflon containers. Corrosion testing was performed by means of vibrational motion at 60 cycles per min in a shaker-bath at 80 degrees C for 15 days. Solution analyses were performed by means of a pH meter, an atomic absorption spectrophotometer, and an inductively coupled plasma spectrometer. Samples exposed to 4% acetic acid solution exhibited a mean weight loss rate (WLR) for the control group (Dicor) of 0.04+/-0.01 mg/cm2 day, which was significantly lower (p < or = 0.0001) than the mean WLR of the CAN2 (1.08+/-0.02 mg/cm2 x day), CAN5 (1.31+/-0.02 mg/cm2 x day), and CAN10(1.51+/-0.05 mg/cm2 x day) groups. The reduced durability of fluorocanasite-based glass-ceramics with increasing Al2O3 concentration is most likely associated with a more uniform distribution of smaller crystals during heat treatment of the glass.

Acetic Acid↗