PubMed Health⌕ Search

Biomedical subjects

K J Jepsen

Publications and source records attributed to K J Jepsen.

12 recordsLinked to original sources

The mechanical consequences of mineralization in embryonic bone.

The purpose of this study was to examine the effect of mineralization on the mechanical properties of embryonic bone rudiments. For this purpose, four-point bending experiments were performed on unmineralized and mineralized embryonic mouse ribs at 16 and 17 days of gestational age. Young's modulus was calculated using force-displacement data from the experiment in combination with finite element analysis (FEA). For the unmineralized specimens, a calculated average for the Young's modulus of 1.11 (+/- 0.62) MPa was established after corrections for sticking to the four-point bending device and aspect ratio, which is the ratio between the length of the bone and its diameter. For the mineralized specimens, the value was 117 (+/- 62) MPa after corrections. Hence, Young's moduli of embryonic bone rudiments increase by two orders of magnitude within 1 day, during endochondral ossification. As an effect, the hypertrophic chondrocytes in the calcifying cartilage experience a significant change in their mechanical environment. The chondrocytes are effectively stress shielded, which means that they do not carry stresses since stresses are supported by the stiffest parts of the tissue, which are in this case the diaphyseal cortex and the calcified matrix. The deformability of the hypertrophic chondrocytes is, therefore, severely reduced. Since the transition is so sudden and enormous, it can be seen as a process of 'catastrophic' proportion for the hypertrophic chondrocytes. The subsequent resorption of calcified cartilage and the expansion of the marrow cavity could be consequential to stress shielding.

Animals↗

Cyclic hydrostatic pressure enhances the chondrogenic phenotype of human mesenchymal progenitor cells differentiated in vitro.

Much attention has been given to the influences of bioactive factors on mesenchymal progenitor cell differentiation and proliferation, but few studies have examined the effect of mechanical factors on these cells. This study examined the effects of cyclic hydrostatic pressure on human bone marrow-derived mesenchymal progenitor cells undergoing chondrogenic differentiation. Aggregates of bone marrow-derived mesenchymal progenitor cells were cultured in a defined chondrogenic medium and were subjected to cyclic hydrostatic pressure. Aggregates were loaded at various time points: single (day 1 or 3) or multiple (days 1-7). At 14 and 28 days, aggregates were harvested for histology, immunohistochemistry, and quantitative DNA and matrix macromolecule analysis. The aggregates loaded for a single day did not demonstrate significant changes in proteoglycan and collagen contents compared with the non-loaded controls. In contrast, for the multi-day loaded aggregates, statistically significant increases in proteoglycan and collagen contents were found on both day 14 and day 28. Aggregates loaded for seven days were larger and histological staining indicated a greater matrix/cell ratio. This study indicates that hydrostatic pressure enhances the cartilaginous matrix formation of mesenchymal progenitor cells differentiated in vitro, and suggests that mechanical forces may play an important role in cartilage repair and regeneration in vivo.

Bone Marrow Cells↗

Bone brittleness varies with genetic background in A/J and C57BL/6J inbred mice.

The contribution of genetic and environmental factors to variations in bone quality are understood poorly. We tested whether bone brittleness varies with genetic background using the A/J and C57BL/6J inbred mouse strains. Whole bone four-point bending tests revealed a 70% decrease in postyield deflection of A/J femurs compared with C57BL/6J, indicating that A/J femurs failed in a significantly more brittle manner. Cyclic loading studies indicated that A/J femurs accumulated damage differently than C57BL/6J femurs, consistent with their increased brittleness. Differences in matrix composition also were observed between the two mouse strains. A/J femurs had a 4.5% increase in ash content and an 11.8% decrease in collagen content. Interestingly, a reciprocal relationship was observed between femoral geometry and material stiffness; this relationship may have contributed to the brittle phenotype of A/J femurs. A/J femurs are more slender than those of C57BL/6J femurs; however, their 47% smaller moment of inertia appeared to be compensated by an increased tissue stiffness at the expense of altered tissue damageability. Importantly, these differences in whole bone mechanical properties between A/J and C57BL/6J femurs could not have been predicted from bone mass or density measures alone. The results indicated that bone brittleness is a genetically influenced trait and that it is associated with genetically determined differences in whole bone architecture, bone matrix composition, and mechanisms of cyclical damage accumulation.

Animals↗

The role of the lamellar interface during torsional yielding of human cortical bone.

Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsional yielding in normal bone. Samples of human femoral cortical bone were loaded in torsion and damaged at a post-yield twist level. The number of microcracks within osteons, interstitial tissue, and along cement lines were assessed using basic fuchsin staining. Damage density measures (number of cracks/mm2) were correlated with stiffness degradation and changes in relaxation. Damaged samples exhibited a wide variation in total microcrack density, ranging from 1.1 to 43.3 cracks/mm2 with a mean density of 19.7 +/- 9.8 cracks/mm2. Lamellar interface cracks comprised more than 75% of the total damage, indicating that the lamellar interface is weak in shear and is a principal site of shear damage accumulation. Damage density was positively correlated with secant stiffness degradation, but only explained 22% of the variability in degradation. In contrast, damage density was uncorrelated with the changes in relaxation, indicating that a simple crack counting measure such as microcrack density was not an appropriate measure of relaxation degradation. Finally, a nonuniform microcrack density distribution was observed, suggesting that internal shear stresses were redistributed within the torsion samples during post-yield loading. The results suggested that the lamellar interface in human cortical bone plays an important role in torsional yielding by keeping cracks physically isolated from each other and delaying microcrack coalescence in order to postpone the inevitable formation of the fatal crack.

Adult↗

Lumican regulates collagen fibril assembly: skin fragility and corneal opacity in the absence of lumican.

Lumican, a prototypic leucine-rich proteoglycan with keratan sulfate side chains, is a major component of the cornea, dermal, and muscle connective tissues. Mice homozygous for a null mutation in lumican display skin laxity and fragility resembling certain types of Ehlers-Danlos syndrome. In addition, the mutant mice develop bilateral corneal opacification. The underlying connective tissue defect in the homozygous mutants is deregulated growth of collagen fibrils with a significant proportion of abnormally thick collagen fibrils in the skin and cornea as indicated by transmission electron microscopy. A highly organized and regularly spaced collagen fibril matrix typical of the normal cornea is also missing in these mutant mice. This study establishes a crucial role for lumican in the regulation of collagen assembly into fibrils in various connective tissues. Most importantly, these results provide a definitive link between a necessity for lumican in the development of a highly organized collagenous matrix and corneal transparency.

Animals↗

Comparison of damage accumulation measures in human cortical bone.

Elastic modulus degradation, strength reduction, and energy dissipation have traditionally been the properties of choice to monitor the damage process in cortical bone. However, these properties only provide limited insight into the damage process given the complex mechanical nature of bone. In the current study, alternative measures of the damage process were investigated for machined human cortical bone specimens loaded under torsion. Seventy-two bone specimens from 6 human femurs were subjected to a series of torsional relaxation cycles in which damage was induced during a single relaxation cycle and the effects of damage on the elastic, yield, viscous, and failure properties were determined from pre- and post-damage relaxation cycles. The results revealed that degradation of all torsion properties exhibited a significant twist magnitude effect. However, the yield stress and strain, the relaxation rate, and the total relaxation exhibited 5-10 fold greater degradation than both strength and modulus, when residual strength tests were conducted at high shear strain rates. For the loading conditions examined in this study, the results indicated that the relaxation and yield properties of cortical bone are more sensitive to shear damage accumulation and better measures of the damage process than either strength or modulus. Further, the results reveal an important interaction between damage and the viscous behavior of bone which provides new insight into the effects of damage on bone mechanical properties.

Adult↗

Type-I collagen mutation compromises the post-yield behavior of Mov13 long bone.

Despite recent advances in our understanding of the molecular basis of skeletal fragility, little is known about how these molecular alterations lead to whole bone brittleness. In the current study, we investigated the relationship between a type-I collagen mutation and post-yield behavior of whole bone in Mov13 transgenic mice by considering tissue-level organizational issues known to be important for normal bone fracture. Mechanical assays revealed that the post-yield deflection of Mov13 femurs was reduced by 61% relative to littermate controls. Fractographic images revealed that lamellar interfaces which were important for dissipating energy during the failure process of control femurs, were not effective in Mov13 mice. Further investigation revealed that a 22% reduction in bone collagen content, a 2-fold increase in tissue porosity, and significant alterations in collagen organization interfered with normal energy dissipation mechanisms of Mov13 microstructure. Collectively, the results provided the first evidence that the reduced ductility associated with a type-I collagen mutation was mediated by alterations in intermediate structures that normally contribute to the post-yield behavior of cortical bone. The results suggest that, to better understand the pathogenesis of skeletal fragility, it is important to consider the effects of molecular alterations on higher-level structures, particularly those structures that contribute to the failure mechanisms in normal bone.

Animals↗

Osteoporosis induced in mice by overproduction of interleukin 4.

Osteoporosis is a common disease in which loss of bone mass results in skeletal fragility. The development of therapies for this disorder has been hampered by the lack of a convenient animal model. Here we describe a disorder in bone homeostasis in transgenic mice that inappropriately express the cytokine interleukin 4 (IL-4) under the direction of the lymphocyte-specific proximal promoter for the lck gene. Bone disease in lck-IL-4 mice appeared to result from markedly decreased bone formation by osteoblasts, features strikingly similar to those observed in cases of severe low-turnover human involutional osteoporosis. By 2 months of age, female and male lck-IL-4 mice invariably developed severe osteoporosis of both cortical and trabecular bone. Osteoporosis was observed in two independently derived founder animals, indicating that this phenotype was directly mediated by the IL-4 transgene.

Actins↗

A murine skeletal adaptation that significantly increases cortical bone mechanical properties. Implications for human skeletal fragility.

Mov13 mice carry a provirus that prevents transcription initiation of the alpha 1(I) collagen gene. Mutant mice homozygous for the null mutation produce no type I collagen and die at mid-gestation, whereas heterozygotes survive to adulthood. Dermal fibroblasts from heterozygous mice produce approximately 50% less type I collagen than normal littermates, and the partial deficiency in collagen production results in a phenotype similar to osteogenesis imperfecta type I (an inherited form of skeletal fragility). In this study, we have identified an adaptation of Mov13 skeletal tissue that significantly improves the bending strength of long bone. The adaptive response occurred over a 2-mo period, during which time a small number of newly proliferated osteogenic cells produced a significant amount of matrix components and thus generated new bone along periosteal surfaces. New bone deposition resulted in a measurable increase in cross-sectional geometry which, in turn, led to a dramatic increase in long bone bending strength.

Aging↗

Application of homogenization theory to the study of trabecular bone mechanics.

It is generally accepted that the strength and stiffness of trabecular bone is strongly affected by trabecular microstructure. It has also been hypothesized that stress induced adaptation of trabecular bone is affected by trabecular tissue level stress and/or strain. At this time, however, there is no generally accepted (or easily accomplished) technique for predicting the effect of microstructure on trabecular bone apparent stiffness and strength or estimating tissue level stress or strain. In this paper, a recently developed mechanics theory specifically designed to analyze microstructured materials, called the homogenization theory, is presented and applied to analyze trabecular bone mechanics. Using the homogenization theory it is possible to perform microstructural and continuum analyses separately and then combine them in a systematic manner. Stiffness predictions from two different microstructural models of trabecular bone show reasonable agreement with experimental results, depending on metaphyseal region, (R2 greater than 0.5 for proximal humerus specimens, R2 less than 0.5 for distal femur and proximal tibia specimens). Estimates of both microstructural strain energy density (SED) and apparent SED show that there are large differences (up to 30 times) between apparent SED (as calculated by standard continuum finite element analyses) and the maximum microstructural or tissue SED. Furthermore, a strut and spherical void microstructure gave very different estimates of maximum tissue SED for the same bone volume fraction (BV/TV). The estimates from the spherical void microstructure are between 2 and 20 times greater than the strut microstructure at 10-20% BV/TV.

Biomechanical Phenomena↗

Type I collagen mutation alters the strength and fatigue behavior of Mov13 cortical tissue.

Despite advances in understanding the molecular basis of Osteogenesis Imperfecta, the mechanisms by which type I collagen mutations compromise whole bone function are not well understood. Previously, we have shown that a heterozygous type I collagen mutation is associated with increased brittleness of long bones from Mov13 transgenic mice, a model of the mild form of Osteogenesis Imperfecta. In the current study, we investigated tissue-level damage processes by testing the hypothesis that the fatigue properties of Mov13 tissue were significantly compromised relative to littermate controls. We also quantified tissue structure and mineral content to explain variations in the fatigue behavior. Micro-beam specimens were machined from the anterior and posterior quadrants of Mov13 and control femurs and subjected to cyclic bending at one of four stress levels. Mov13 tissue exhibited a 22-25% reduction in tissue bending strength and a similar reductions in fatigue life and the stress level at which damage was apparent. These results provided tissue-level evidence that damage accumulation mechanisms were significantly compromised in Mov13 cortical tissue. Given that significant alterations in tissue structure were observed in Mov13 femurs, the results of this study support the idea that Mov13 femurs were brittle because alterations in tissue structure associated with the mutation interfered with normal damage processes. These results provide new insight into the pathogenesis of Osteogenesis Imperfecta and are consistent with bone behaving as a damaging composite material, where damage accumulation is central to bone fracture.

Absorptiometry, Photon↗