PubMed Health⌕ Search

Biomedical subjects

K J Lehmann

Publications and source records attributed to K J Lehmann.

At least 37 records · Page 2Linked to original sources

Pancreatic cancer: value of dual-phase helical CT in assessing resectability.

PURPOSE: To evaluate the use of dual-phase helical computed tomography (CT) (with or without CT angiography) to assess resectability in patients suspected to have pancreatic cancer. MATERIALS AND METHODS: Tumor resectability was prospectively evaluated in 89 patients who later underwent surgery for suspected pancreatic cancer. Helical CT scans were obtained in the vascular phase and a phase of maximal hepatic enhancement. CT angiograms were produced with multiprojection volume reconstruction and maximum-intensity projection. CT results were correlated with surgical and histopathologic results. RESULTS: Helical CT allowed detection of pancreatic cancer in 74 of 76 cases (97%). There were six false-positive results (positive predictive value, 92%). For prediction of irresectability, helical CT had an accuracy of 91%, negative predictive value of 79%, and sensitivity of 91%. Helical CT allowed detection of liver metastases in 21 of 28 cases (75%), nodal involvement in 13 of 24 cases (54%), and vascular invasion in 35 of 40 cases (88%). CT angiography demonstrated 30 of the 35 cases of vascular invasion detected with helical CT (86%). CONCLUSION: Use of dual-phase helical CT improves prediction of resectability in patients with pancreatic cancer. CT angiography cannot show all of the findings seen on helical scans.

Adenocarcinoma↗

Teleradiology: results of a questionnaire of German radiologists.

A questionnaire was sent by mail to 4400 radiologists (i.e. to at least 1000 radiological institutions). The response rate was about 5%. The results showed that 47% of respondents felt well informed about teleradiology, 49% not enough and 3% not at all. Image and report transfer as well as interfaces to reference databases, educational applications, technical quality surveillance and product support (maintenance) were considered to be increasingly important areas. Smaller institutions (1-3 doctors) judged expert consultation as more important than bigger institutions. Standardization, system stability and data security were demanded as well as guidelines, for example concerning the linking of report and image, correct documentation and required image quality. Technically most demands can be fulfilled today but this technology is not yet commonly included in teleradiology systems.

Attitude of Health Personnel↗

Radiation dose and image quality in spiral computed tomography: multicentre evaluation at six institutions.

The purpose of this study was to evaluate the correlation of radiation dose with image quality in spiral CT. Seven clinical protocols were measured in six different radiological departments provided with four different types of high specification spiral CT scanners. Central and surface absorbed doses were measured in acrylic. The practical CT dose index (PCTDI) was calculated for seven clinical examination protocols and one standardized protocol using identical parameters on four different spiral CT scanners with a dedicated ionization chamber inserted into PMMA phantoms. For low contrast measurements, a cylindrical three-dimensional (3D) phantom (different sized spheres of defined contrast) was used. Image noise was measured with a cylindrical water phantom and high contrast resolution with a Perspex hole phantom. Image quality phantoms were scanned using the parameters of the clinical protocols. Images were randomized, blinded and read by six radiologists (one from each institution). PCTDI values for four different scanners varied up to a factor between 1.5 (centre) and 2.2 (surface) for the standardized protocol. A greater degree of variation was observed for seven clinical examination protocols of the six radiological departments. For example, PCTDI varied up to a factor between 1.7 (cerebrum protocol) and 8.3 (abdomen paediatric protocol). Low contrast resolution correlates closely with dose. An improvement in detection from 8 mm to 4 mm sized spheres needs approximately a ten-fold increase in dose. Noise shows a moderate correlation with PCTDI. High contrast resolution of clinical protocols is independent of PCTDI within a certain range. Differences in modern CT scanner technology seem to be of less importance for radiation exposure than selection of protocol parameters in different radiological institutes. Future discussion on guidelines regarding optimal (patient adapted) tube current for clinical protocols is desirable.

Brain↗

[Clinical use of a new analytical method for the determination of bone density by means of quantitative computer tomography].

AIM: Evaluation of the clinical suitability of a new analytical method for the determination of bone mineral density (BMD) by means of SEQCT as well as a comparison with the established method. METHODS: In order to verify the stability of both systems, phantom measurements were performed on a lumbal spine torso as well as on 78 patients. 44 patients were examined by means of the established method and 34 according to the new method. Parallel measurements were possible in 15 patients. RESULTS: The phantom measurements proved a high stability of both methods. Regarding the absolute BMD the new method resulted in higher BMD values. This result was confirmed by parallel measurements in 15 patients. The new method demonstrated increased suitability due to less time consuming preparations. Dose reduced scan parameters could not be achieved in all patients, so that the time saving effect could not be considered. In these cases manual settings were required. CONCLUSION: A substitution of the established method for BMD measurement by means of SEQCT with the new method seems to be possible. However, the results will have to be corrected by the percentage of deviation from the default value of the quality phantom.

Absorptiometry, Photon↗

[Possible applications of the KAMEDIN teleradiology system with special reference to an economic analysis].

INTRODUCTION: Different concepts and applications of teleradiology systems have been realised. However, their cost-effectiveness is still questionable. Therefore, a cost-benefit analysis of three different scenarios of the new teleradiology system Kamedin (Kooperatives Arbeiten und rechnergestützte Medizinische Diagnostik auf innovativen Netzen der Deutschen Telekom) was performed. METHODS: CT examinations were transmitted from an Advantage Windows (GE) workstation to a Kamedin workstation using DICOM 3 protocol. Afterwards a teleconference was established with a Kamedin workstation in the intensive care unit within the hospital via FDDI/Ethernet, with an external workstation in a radiology department 6 km away via ISDN and with a Kamedin PC located with radiologist on duty 22 km away via ISDN. On average, 36 CT slices per patient were transferred. A break-even analysis was performed with respect to costs of hardware, software, support, use of ISDN and staff, as well as benefits like the decrease in transportation or film documentation costs. RESULTS: Owing to the different reductions in transportation costs, two applications (intensive care unit and external PC) showed a break-even of 1817 and 528 teleconferences/year, respectively. Further optimisation of cost-effectiveness is possible on condition that existing hardware can be used and an automatic data transfer without staff control is available. When all optimisation factors were combined, the break-even decreased to a minimum of 167 and 77 teleconferences/ year, respectively. CONCLUSION: Teleconferences with high image quality can be set up between workstations and PCs using the Kamedin system. Depending on the possible decrease in transportation costs, teleconferencing is cost-effective under certain conditions. Teleradiology has additional advantages, such as the acceleration and optimisation of patient management.

Computer Communication Networks↗

[Value of high-resolution CT of the lungs in acute pulmonary symptoms of patients with HIV infections].

PURPOSE: The purpose of this study was to assess the clinical value of HRCT of the lung in patients with known HIV-infection and acute lung disease. In a prospective study a HRCT was performed in 31 patients infected with the HIV-1 virus, mainly stage C (CDC), who had acute pulmonary symptoms. Precondition for the HRCT examination was a normal or non-specific chest radiograph. A provoked sputum as well as bronchoscopy with bronchoalveolar lavage and/or transbronchial biopsy were performed concurrently. In 24 out of 31 cases a pathogenic organism was identified. 19 of these 24 patients showed abnormal HRCT findings. The most frequent pathogenic organism was Pneumocystis carinii (n = 12). 9 out of these 12 patients (75%) showed pathological HRCT findings consisting of ground-glass opacity. Specific patterns of attenuation could not be worked out except for Pneumocystis carinii infection. Compared to bronchoalveolar lavage, the diagnostic value of HRCT is inferior; it is however helpful in the early stage of disease, when the pathogenic organism has not yet been identified, HRCT may demonstrate parenchymal abnormalities in patients with normal radiographic findings. Compared to bronchoalveolar lavage and induced sputum, HRCT can provide conclusive results within a short time.

AIDS-Related Opportunistic Infections↗

[Bolus tracking and NaCl bolus in biphasic spiral CT of the abdomen].

PURPOSE: To optimise injection parameters in helical CT of the abdomen with individual bolus tracking and subsequent NaCl bolus injection. To investigate the effect of bolus tracking on image quality in the abdomen. METHODS: Patients were randomised into three examination protocols and underwent biphasic helical CT (Hi-Speed Advantage, GE). The effect of NaCl bolus on duration of aortic enhancement was investigated. Contrast enhancement in parenchyma and vessels was examined. The influence of body mass index, injection flow and contrast material volume on enhancement was evaluated. RESULTS: Subsequent injection of NaCl provided significant extension of contrast enhancement in the aorta. Optimal image quality for pancreas and abdominal arteries was achieved in the arterial phase and for liver, spleen, kidneys and abdominal veins in the portal venous phase. Body mass index, injection flow and contrast material volume showed a significant influence on the time intervals resulting from bolus tracking. CONCLUSION: Individual bolus tracking with subsequent injection of 20 ml NaCl bolus optimises intravenous contrast application.

Aorta, Abdominal↗

Ultrafast magnetic resonance imaging improves the staging of pancreatic tumors.

OBJECTIVE: This prospective study was undertaken to evaluate the accuracy of a noninvasive "all-in-one" staging method in predicting surgical resectability in patients with pancreatic or periampullary tumors. SUMMARY BACKGROUND DATA: Despite progress in imaging techniques, accurate staging and correct prediction of resectability remains one of the chief problems in the management of pancreatic tumors. Staging algorithms designed to separate operable from inoperable patients to save the latter an unnecessary laparotomy are becoming increasingly complex, expensive, time-consuming, invasive, and not without risks for the patient. METHODS: Between August 1996 and February 1997, 58 consecutive patients referred for operation of a pancreatic or periampullary tumor were examined clinically and by 5 staging methods: 1) percutaneous ultrasonography (US); 2) ultrafast magnetic resonance imaging (UMRI); 3) dual-phase helical computed tomography (CT); 4) selective visceral angiography; and 5) endoscopic cholangiopancreatography (ERCP). The assessment of resectability by each procedure was verified by surgical exploration and histologic examination. RESULTS: The study comprised 40 male and 18 female patients with a median age of 63 years. Thirty-five lesions were located in the pancreatic head (60%), 11 in the body (19%), and 1 in the tail of the gland (2%); there were 9 tumors of the ampulla (16%) and 2 of the distal common duct (3%). All five staging methods were completed in 36 patients. For reasons ranging from metallic implants to contrast medium allergy or because investigations already had been performed elsewhere, US was completed in 57 (98%), UMRI in 54 (93%), CT in 49 (84%), angiography in 48 (83%), and ERCP in 49 (84%) of these 58 patients. Signs of unresectability found were vascular involvement in 22 (38%), extrapancreatic tumor spread in 16 (26%), liver metastases in 10 (17%), lymph node involvement in 6 (10%), and peritoneal nodules in only 2 patients (3%). These findings were collated with those of surgical exploration in 47 patients (81 %) and percutaneous biopsy in 5 (9%); such invasive verification was deemed unnecessary and therefore unethical in 6 clearly inoperable patients (10%). In assessing the four main signs of unresectability (extrapancreatic tumor spread, liver metastases, lymph node involvement, and vascular invasion), the overall accuracy of UMRI was 95.7%, 93.5%, 80.4%, as compared to 85.1%, 87.2%, 76.6% for US and 74.4%, 87.2%, 69.2% for CT. In assessing vascular invasion, the sensitivity, specificity, and overall accuracy of angiography were 42.9%, 100%, and 68.8%, respectively. There were 3 complications (12.5%) after 24 resections, 5 in 17 palliative procedures, and none after 6 explorations only. The hospital stay was 14 days after resection, 13 after palliative bypass, and 6 after exploration alone. There was no operative or hospital mortality in these 58 cases. CONCLUSIONS: Although it is by no means 100% accurate, UMRI is equal or even superior to all other staging methods. It probably will replace most of these, because it provides an "all-in-one" investigation avoiding endoscopy, vascular cannulation, allergic reactions, and x-radiation. But because even UMRI is not perfect, the final verdict on resectability of a tumor still will depend on surgical exploration in some cases.

Adult↗

[Goals, requirements and prerequisites of teleradiology. An assessment of current status].

Specific radiological requirements have to be considered for the realization of telemedicine. In this article the goals and requirements for an extensive introduction of teleradiology will be defined from the radiological user's point of view. Necessary medical, legal and professional prerequisites for teleradiology are presented. Essential requirements, such as data security, maintenance of personal rights and standardization, must be realized. Application-specific requirements, e.g. quality and extent of teleradiological functions, as well as technological alternatives, are discussed. Each project must be carefully planned in relation to one's own needs, extent of functions and system selection. Topics, such as acknowledgement of electronic documentation, reimbursement of teleradiology and liability, must be clarified. Legal advice and the observance of quality guidelines are recommended.

Forecasting↗

[Clinical use of software-controlled x-ray tube modulation with "Smart-Scan" in spiral CT].

PURPOSE: The modulation of tube current during 360 degree-rotation for equalization of local differences in absorption is able to reduce patient exposure in spiral-CT. The impact on CT investigations of thorax, abdomen and pelvis and the influence of patient geometry within the slice on the decrease of tube current are evaluated. METHODS: 300 spiral-CT's were performed on a HiSpeed Advantage scanner (GE) using a software-triggered modulation of tube current ("Smart-Scan"). The local absorption was measured in the 100 central channels of 2 scoutiviews (lateral and a.p.) and used for anatomical adapted modulation. The reduction of exposure as well as the height and width of the body cross-section were measured in reference slices of 100 thorax, 100 abdomen and 100 pelvis examinations. RESULTS: The use of "Smart-Scar" enables a decrease of tube current of 7% in thorax, 6% in abdomen and 11% pelvis. There is a significant correlation between the height and width of body cross-section and the reduction of exposure for examinations of thorax and abdomen, but not of the pelvis. CONCLUSION: Independent of patient geometry the clinical use of "Smart-Scan" achieves the pelvis. Anatomical regions with an oval body cross-section show a decrease of x-ray tube current, too.

Adult↗

[Spiral CT angiography in stenoses of the middle cerebral artery].

INTRODUCTION: Transcranial Doppler ultrasonography (TCD) and magnetic resonance angiography (MRA) are well-established techniques for ascertaining intracranial obstructive artery disease. The short examination time required for additional helical CT angiography (CTA) allows quick management of emergency patients already undergoing native CT. However, today the ability of CTA to detect stenoses of the middle cerebral artery (MCA) has not been proven. To analyse the value of CTA in the classification of atherosclerotic disease 23 MCA stenoses confirmed by TCD and MRA were investigated. METHODS: CTA was performed on a Hispeed advantage scanner (GE) using a bolus injection of 70 ml KM and 40 ml NaCl with a flow rate of 2.5 ml/s, a thickness of 1 mm, a pitch of 1.5 and a 1 mm increment. CTA was presented as maximum intensity projection (MIP) and as multi-projection volume reconstruction (MPVR). A three-step classification of stenosis was compared with the results of TCD and MRA. RESULTS: Good opacification of the MCA was achieved in M1 and M2 segments in all patients. Classification of stenosis by CTA agreed with MRA and TCD in 14 cases; 7 stenoses were assigned to a lower classification by CTA. Two low-grade stenoses could not be proven by CTA. Although MIP and MPVR yield the same result in stenosis classification MPVR showed a sharper image quality. In contrast to MRA, veins were highly opacified in CTA. Artery and vein were sometimes superimposed, which had to be avoided by changing the projection angle. CONCLUSION: Medium- and high-grade MCA stenoses can be demonstrated by CTA quickly and reliably. Compared to MRA and TCD, CTA provides lower grading of stenosis.

Blood Flow Velocity↗

[Development of a clinical-radiological CD-ROM database for focal lesions of the liver].

PURPOSE: The development of a CD-ROM database for continuous acquisition and archiving of interesting radiologic cases is described. As a pilot study radiologic images of focal lesions of the liver were collected. METHODS: The database runs on a PC (80486 DX2, 66 MHz, 16 MB RAM), which is connected to the clinic network, a high quality x-ray scanner and a CD-ROM writer. Radiologic images can be inserted into the database either by scanner or by image transfer via network. The database is designed using Access 2.0. Well documented cases were chosen retrospectively, manipulated and archived. RESULTS: 308 images of 12 focal lesions with a capacity of 802 MB were stored on CD-ROM. Per case a storage capacity of 40-75 MB is necessary for image raw material, 15-25 MB are necessary for the postprocessed data. Spatial resolution is 190 dpi (3000 pixel/40 cm). Clinical data, radiological diagnosis coded by modified ACR index and a compressed icon of the images are stored on PC, the image data are stored on CD-ROM. 2.5 hours per case are needed for the complete acquisition, manipulation and archiving procedure, but improved hardware configuration can reduce the time significantly. CONCLUSION: The described database allows continuous archiving of interesting radiologic cases on PC. ACR index is suited for a quick search of a specific combination of radiologic images and diagnosis from different modalities.

Angiography↗

[Septic portal vein thrombosis as a rare complication of Crohn disease with retroperitoneal abscess].

Portal vein thrombosis is a rare complication of inflammatory bowel disease and occurs particularly in patients with ulcerative colitis. This report describes a patient with known Crohn's disease since 1980 who developed retroperitoneal abscesses and subsequently a septic portal vein thrombosis. After 10 years of remission, clinical deterioration, jaundice, and fever occurred. An abdominal CT-study confirmed the ultrasonic presumptive diagnosis of two retroperitoneal abscesses close to the pancreas tail. Another CT, one week later, showed furthermore a portal vein thrombosis. Only by intensive care treatment was it possible to control the critical situation.

Abdominal Abscess↗

[Radiologic medical desktop conferences--clinical evaluation of the KAMEDIN teleradiology system in routine practice of a radiologic institute].

KAMEDIN is a teleradiology project of "Deutsche Telekom". ISDN based image transfer, visualisation and online-presentation of digital radiological images is performed. In this study the suitability of the KAMEDIN-system has been tested in a clinical environment. The software has been adapted to the requirements of radiological image visualisation. During 6 months over 50 conferences took place with an average of 36 CT-slices per patient. The amount of time was approximately 10 min for conference preparation, 20 min for image transfer and 8 min for conferencing. Software problems occurred and were solved. Image quality on the monitor as well as online presentation including "simultaneous cursors" showed high performance and achieved high acceptance by the clinicians. Thus KAMEDIN is a useful teleradiology system, especially if the system is adapted to the requirements of radiology departments.

Computer Systems↗