PubMed Health⌕ Search

Biomedical subjects

K J Rogers

Publications and source records attributed to K J Rogers.

At least 19 recordsLinked to original sources

A high-capacity LC/MS system for the bioanalysis of samples generated from plate-based metabolic screening.

HPLC/MS is a linear technique characterized by serial injection and analysis of individual samples. Parallel-format high-throughput screens for druglike properties present a significant analytical challenge. Analysis speed and system ruggedness are key requirements for bioanalysis of thousands of samples per day. The tasks involved in LC/MS analysis are readily divided into three areas, sample preparation/liquid handling, LC/MS method building/sample analysis, and data processing. Several automation and multitasking strategies were developed and implemented to minimize plating and liquid handling errors, reduce dead times within the analysis cycle, and allow for comprehensive review of data. Delivering multiple samples to multiple injectors allows the autosampler time to complete its wash cycles and aspirate the next set of samples while the previous set is being analyzed. A dual-column chromatography system provides column cycling and peak stacking and allows rapid throughput using conventional LC equipment. Collecting all data for a compound into a single file greatly reduces the number of data files collected, increases the speed of data collection, allows rugged and complete review of all data, and provides facile data management. The described systems have analyzed over 40 000 samples per month for two years and have the capacity for over 2000 samples per instrument per day.

Automation↗

AutoScan: an automated workstation for rapid determination of mass and tandem mass spectrometry conditions for quantitative bioanalytical mass spectrometry.

An automated flow injection analysis (FIA) mass spectrometry system (AutoScan) was developed to allow rapid unattended determination of optimal conditions during mass (ms) and tandem mass spectrometry (ms/ms) on new chemical entities (NCEs) arranged in 96-well plates. The 96-well plate is placed on the deck of a modified Gilson Multiprobe autosampler for injection into a PE Sciex API 2000 triple quadrupole mass spectrometer. A customized software interface is used to create the necessary scan experiments by associating each 96-well plate of NCEs to be scanned with an index file containing data on the identity of each analyte and its expected molecular weight. Analytes are injected four at a time into a custom injection manifold and conventional mass spectra are acquired in both polarities (+/-) using an alternating positive/negative Q1 scan function. The software determines the optimal polarity and definitive precursor ion for all analytes and uses the results to build the injection sequence for product ion scanning. The samples are automatically re-injected under MS/MS conditions, and product ion scans that loop among different collision energies are collected for each analyte. The resulting data are processed automatically and the optimal MS/MS transitions for each analyte are selected. A color-coded graphical interface facilitates data review. Any unusual ion transitions or transposition errors made during plate preparation are noted and corrected. Complete MS and MS/MS conditions are obtained for 96 compounds in about one hour and the resulting data are available for download as sample control injection sequence files.

Automation↗

Arterial hypoxaemia in endurance athletes is greater during running than cycling.

The effect of both training discipline and exercise modality on exercise-induced hypoxaemia (EIH) was examined in seven runners and six cyclists during 5 min high intensity treadmill and cycle exercise. There were no significant interactions between training discipline, exercise modality and arterial P(O(2)) (Pa(O(2))) when subject groups were considered separately but when pooled there were significant differences between exercise modalities. After min 2 of exercise arterial hydrogen ion concentration, minute ventilation, alveolar P(O(2)) (PA(O(2))) and Pa(O(2)) were all lower with treadmill running with the largest differential for the latter occurring at min 5 (treadmill, 80.8+/-1.8; cycle, 90.2+/-2.5, mmHg, N=13, P< or = 0.05). At every min of exercise, the differences in Pa(O(2)) between the ergometers were strongly associated with similar differences in PA(O(2)) and alveolar to arterial P(O(2)) (PA(O(2))-Pa(O(2))). It is concluded that the greater EIH with treadmill running is a consequence of the combined effect of a reduced lactic acidosis-induced hyperventilation and greater ventilation-perfusion inequality with this exercise mode.

Acidosis, Lactic↗

A phase II trial of murine monoclonal antibody 17-1A and interferon-gamma: clinical and immunological data.

A group of 15 patients with metastatic colorectal adenocarcinoma received a combination of interferon gamma (0.1 mg/m2, days 1-15) and the murine monoclonal antibody 17-1A (400 mg, days 5, 7, 9 and 12). The treatment was tolerated with minimal toxicity. Of the 14 evaluable patients, 13 developed human antibody to murine 17-1A, with 11 patients demonstrating antibody to the variable region of 17-1A (anti-idiotype). Antibody to the variable region was inhibited by 17-1A but not by mouse immunoglobulin. Sera from patients with substantial anti-idiotype reactivity were capable of inhibiting the binding of murine 17-1A to antigen expressing LS174-T cells thus indicating the presence of antibody directed against the 17-1A combining site (mirror-image anti-idiotype). The median survival of the whole group was 56 weeks and there was no correlation between clinical response/survival and the development of anti-idiotype antibody.

Adenocarcinoma↗

Quantitative assay of a human monoclonal IgM antibody (HA-1A) in human serum.

A rapid, specific and sensitive radiometric assay was developed capable of quantitating serum levels of HA-1A, a human IgM monoclonal antibody to endotoxin. 'Private' anti-idiotypic murine monoclonal antibodies were produced and utilized in the assay to avoid cross-reactivity with normal human IgG, IgM, IgA, IgE or IgD. The presence of E. coli or gram-negative lipopolysaccharide in the sera did not affect the ability of the assay to detect HA-1A. The sensitivity of the assay was calculated to be 25 ng/ml with an interassay coefficient of variation of less than 10%. In one patient given 100 mg of HA-1A, peak serum concentration was 101.5% of the predicted value with a mean plasma half life of 24.5 h. This assay will be useful in establishing the pharmacokinetics of HA-1A and in monitoring serum levels during phase II and phase III clinical trials.

Animals↗

Development and characterization of a monoclonal antibody to human embryonal carcinoma.

A monoclonal anti-testicular carcinoma antibody was obtained via the somatic cell fusion technique by immunization of BALB/c mice with freshly prepared single cell suspension from a patient with testicular embryonal carcinoma with choriocarcinoma components. The hybridoma supernates were screened against the testicular carcinoma cells used in the immunization as well as normal mononuclear white blood cells isolated from the same patient. An antibody (5F9) was selected which bound to fresh tumor cells from two patients with embryonal testicular carcinoma and failed to bind to fresh tumor cells from 24 patients (2 seminoma, 2 melanoma, 3 neck, 2 esophageal, 1 ovarian, 3 colon, 1 prostate, 2 breast, 1 liposarcoma, 3 endometrial, 1 kidney, 1 adrenal, 1 larynx and 1 bladder tumors) or cell suspensions prepared from normal liver, lung, spleen, ovary, testes, kidney, red blood cells or white blood cells. The antibody was tested for its binding to several well established cancer cell lines, and was found to bind to the BeWo human choriocarcinoma and two human embryonal carcinoma cell lines. The antibody did not react with 22 other cell lines or with hCG. The antibody was labeled with 131I and injected into nude mice bearing BeWo tumors and evaluated for tumor localization by performing whole body scans with a gamma camera 5 days later. Six mice injected with the antibody showed positive tumor localization without the need for background subtraction while six mice injected with MOPC-21, a murine myeloma immunoglobulin, demonstrated much less tumor localization. Tissue distribution studies performed after scanning showed specific tumor localization (8:1 tumor: muscle) for the monoclonal antibody and no specific localization for MOPC-21. This antibody thus has selective reactivity with the surface of tumor cells from embryonal carcinoma (testicle) and choriocarcinoma both in vitro and in vivo.

Animals↗

Sonographic detection of fibromatosis: a rare tumor in the retroperitoneum.

Abdominal sonography for the detection and evaluation of mass lesions is a common investigative modality. The authors wish to report a case of an unusual retroperitoneal tumor that was detected by ultrasound. The lesion, fibromatosis, was symptomatic but went undiagnosed for over a year, despite two evaluations which included multiple standard roentgenographic studies. Fibromatosis is discussed.

Child, Preschool↗

Effect of hypophysectomy on persistence of methylated purines in rat liver deoxyribonucleic acid after administration of dimethylnitrosamine.

The formation of methylated purines in DNA following dimethylnitrosamine administration was studied in control and hypophysectomized rats. When given the same dose of this carcinogen (in mg/kg body weight) the formation of the major product 7-methylguanine and of the minor products 1-, 3- and 7-methyladenine and 3-methylguanine was slightly greater in the livers of hypophysectomized rats than in controls. The rate of loss of these products from the DNA was not affected by hypophysectomy. O6-Methylguanine levels were significantly greater in the hepatic DNA of hypophysectomized rats compared to controls after doses of dimethylnitrosamine ranging from 1 to 20 mg/kg. This difference was due to a slower rate of loss of this purine from the DNA in the hypothysectomized rats. Growth hormone treatment increased the rate of removal of O6-methylguanine in the hypophysectomized rats but did not restore the activity to that found in controls. The possible significance of these results in the induction of tumors by dimethylnitrosamine is discussed.

Adenine↗

Studies in vivo on the effects of parathyroid hormone upon kidney cyclic adenosine 3',5'-monophosphate content using rapid tissue fixation by microwave irradiation.

Microwave irradiation is shown to be a useful method for simultaneously killing chicks and fixing tissues. Renal adenylate cyclase and phosphodiesterase activities were rapidly abolished by microwaving. The increase in chick kidney cyclic adenosine 3',5'-monophosphate (cyclic AMP) content produced by intravenous bovine parathyroid hormone (PTH) injection was much greater in microwaved birds than in those killed by cervical dislocation with subsequent tissue fixation in liquid nitrogen. After PTH injection there was a prolonged elevation of renal cyclic AMP content. At the time of maximum response (2 minutes), log. dose-response curves were linear in the dose range 0.1-10 U. The responses to three different bovine PTH preparations were indistinguishable. Arginine vasopressin, arginine vasotocin, salmon calcitonin and prostaglandin E1 did not affect kidney cyclic AMP content within 2 minutes. Because of its specificity and precision, the method is of use for the in vivo bioassay of PTH. Injection of CaCl2 (20 mumoles) 1 minute before, or conjointly with, bovine PTH inhibited the subsequent increase in kidney cyclic AMP content. The synthetic bovine PTH peptide fragments BPTH (1-34) and BPTH (2-34) both increased chick kidney cyclic AMP content. The use of such fragments allows investigation of the structural requirements of PTH for interaction with the systems regulating cyclic AMP metabolism in the kidney in vivo.

Animals↗