PubMed Health⌕ Search

Biomedical subjects

K Jordan

Publications and source records attributed to K Jordan.

At least 37 records · Page 2Linked to original sources

A brief screening tool for knee pain in primary care (KNEST). 2. Results from a survey in the general population aged 50 and over.

OBJECTIVE: To use a brief screening tool to identify knee pain (all knee pain, non-chronic and chronic knee pain) and associated health-care use in the general population aged 50 yr and over. METHODS: A cross-sectional survey was mailed to 8995 individuals registered with three general practices in North Staffordshire, UK. The questionnaire included a Knee Pain Screening Tool (KNEST), the Short Form 36 (SF36), demographic questions and, for those who reported knee pain, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). RESULTS: The survey achieved a 77% response. The 12-month period prevalence of all knee pain was 46.8% [95% confidence interval (CI) 45.6%, 48.0%]. Figures for non-chronic knee pain (pain of less than 3 months duration) and chronic knee pain (pain of more than 3 months duration) were 21.5% (95% CI 20.5%, 22.5%) and 25.3% (95% CI 24.3%, 26.4%) respectively. An estimated 6% of the older population had non-chronic but severe knee pain or disability. Thirty-three per cent of all knee pain sufferers had consulted their general practitioner (GP) about their symptom in the last year. This included 34% of those with non-chronic but severe knee pain or disability and 56% of those with chronic and severe knee pain or disability. The use of private treatments or services for knee pain was minimal. A third of those with chronic and severe knee pain or disability had not used any services (including GP) in the last year. CONCLUSIONS: The KNEST is a simple tool for the identification of individuals with knee pain and their health-care use. Focusing only on chronic knee pain will underestimate the total need and demand for health-care in knee pain sufferers in the general older population, as non-chronic as well as chronic knee pain has a significant impact on people's lives and on their use of primary health-care. The KNEST, when combined with the WOMAC, identifies population groups who have potentially diverse health-care needs and who might benefit from effective health-care. These data can be used alongside evidence on effective treatments by service planners when considering needs for the care of older adults in primary care.

Aged↗

Describing three-dimensional cervical spine movement in a diseased and a non-diseased group using multilevel modelling.

Clinicians often request patients to perform movements of joints as an aid to assessment and diagnosis of many diseases. However, patients may perform abnormal secondary movements where their primary movement is limited. A new measuring system, the FASTRAK, has the potential to measure movement in three dimensions, and to measure movements of the body away from the primary movement. This paper explores the use of multilevel modelling to describe the patterns of movement where subjects are measured on several occasions for both a non-diseased group and for a group of subjects suffering from ankylosing spondylitis. Three-level multilevel models are described with level 3 being the subjects, level 2 being the measurement occasions (up to three) and level 1 being the measurements (three) on each occasion. The models highlight which are the most important secondary movements during the primary movement and show clinically interpretable patterns of movement that can highlight differences between diseased and non-diseased groups.

Adult↗

[Physiological and technical limitations of functional magnetic resonance imaging (fMRI)--consequences for clinical use].

Functional magnetic resonance imaging (fMRI) is the most common noninvasive technique in functional neuroanatomy. The capabilities and limitations of the method will be discussed based on a short review of the current knowledge about the neurovascular relationship. The focus of this article is on current methodical and technical problems regarding fMRI-based detection and localization of neuronal activity. Main error sources and their influence on the reliability and validity of fMRI-methods are presented. Appropriate solution strategies will be proposed and evaluated. Finally, the clinical relevance of MR-based diagnostic methods are discussed.

Brain Diseases↗

Is screening with digital imaging using one retinal view adequate?

PURPOSE: To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &<5% technical failure). METHODS: Diabetics referred for screening were studied in a prospective fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. RESULTS: A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). CONCLUSION: The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.

Diabetic Retinopathy↗

Increased vaginal bleeding: the reasons women give for consulting primary care.

A previous study identified interference with life as the main reason for consultation with increased vaginal bleeding. The purpose of this study was to determine the reasons why the heaviness of periods interferes with life and how this may be related to consultation. The design was a case-control study in which questionnaires were sent to women who consulted primary care with new episodes of increased vaginal bleeding and two groups of controls: consulting controls with another illness and non-consulting community controls. Of the 186 women who reported that heaviness of periods interfered with life the most common reason given was 'mood' (87%). There was no difference in the reporting of 'mood' interfering with life or general health questionnaire score between cases, consulting controls and non-consulting controls. Women who report heavy periods interfering with life complain most commonly of mood as one of the reasons. This does not distinguish consulters and non-consulters and is not reflected in objective measures of psychological distress. Clinicians should focus initially on treating the presenting physical symptoms.

Adolescent↗

How do GPs use x rays to manage chronic knee pain in the elderly? A case study.

OBJECTIVES: To determine whether clinical signs and symptoms of osteoarthritis influence general practitioners' (GPs) decisions about x raying older patients with knee pain and whether x ray reports alter their initial treatment or referral plan. METHODS: A cross sectional survey of 1000 GPs in England and Wales using "paper cases" in three questionnaires mailed at two-weekly intervals. The first questionnaire assessed GPs' management of patients with knee pain using four case scenarios, two with features of clinical knee osteoarthritis. The second questionnaire contained the same scenarios with information on x ray findings added. The third questionnaire considered management of knee pain in general. RESULTS: 447 GPs responded to questionnaire 1, 316 (71%) to questionnaire 2, 287 (64%) to questionnaire 3. 106 responders (25%) would have x rayed all four patients and 64 (15%) none. Choosing to carry out an x ray examination was not influenced by the presence of clinical signs and symptoms of osteoarthritis but was linked to other management choices, such as referral to orthopaedics (odds ratio (OR) 2.13; 95% confidence interval (CI) 1.62 to 2.81). The strongest predictor in questionnaire 2 of a treatment or referral was whether it had been chosen in the first survey. However, the x ray report was associated with a significant change in treatment and referrals. Where radiographic osteoarthritis was present, GPs were less likely to refer to a physiotherapist (OR 0.64; 95% CI 0.50 to 0.83) or rheumatologist (OR 0.15; 95% CI 0.08 to 0.28), and more likely to refer to an orthopaedic surgeon (OR 31.34; 95% CI 21.51 to 45.66). Questionnaire 3 showed that GPs' general views on the use of x rays correlated with the frequency of their choosing to x ray in the four individual case scenarios. CONCLUSIONS: A GP's choice to x ray older people with knee symptoms is linked with decisions on treatment and referral even before the x ray result is known, but it does not appear to be influenced by clinical features of osteoarthritis. The presence of radiographic osteoarthritis has a marked impact on the decision to refer to secondary care. More evidence on the outcome of management without x rays is needed to help GPs in decision making.

Adrenal Cortex Hormones↗

Previous consultation and self reported health status as predictors of future demand for primary care.

STUDY OBJECTIVE: There has been little prospective investigation of what predicts general practice consultation. The objective of this study was to investigate the extent to which previous primary care consultation and self reported health status are predictors of future primary care consultation. DESIGN: Population based cohort study in two phases. Firstly, a baseline survey (1995/96) to identify the cohort and to obtain self reported health status using the UK census limiting long term illness (LLI) question and the Short Form-36 (SF-36) health profile. Secondly, analysis of general practice medical records for two years (1994/1995) before the survey and for two years (1997/1998) after the survey. Analysis was performed on: (a) all contacts coded by the GP, (b) the subgroup of contacts given a diagnostic morbidity code by the GP. SETTING: One general practice in North Staffordshire, UK. PARTICIPANTS: 738 survey respondents who had consented to viewing of medical records including all those who reported LLI together with an age-gender matched control group of those who reported no LLI. MAIN RESULTS: High frequency consulters in 1994/95 were more likely than non-consulters or average consulters in that year to be high consulters in 1997/98 (odds ratio 5.6, 95% confidence interval 3.82 to 8.25, for all contacts; 4.4 for diagnostic coded consultations). Self reported role disability and physical limitation from the SF-36 at baseline increased the probability of being a future high consulter but the effects were weaker than for previous consultation. Previous consultation within a diagnostic group was the main predictor for future consultation within that group with weaker but significant prediction by self reported health status. CONCLUSIONS: Reliable morbidity coding in general practice provides the best available basis for predicting future demand in primary care. Self reported health status survey instruments add to this information but on their own are weaker predictors of future consultation.

Adult↗

High-power terahertz radiation from relativistic electrons.

Terahertz (THz) radiation, which lies in the far-infrared region, is at the interface of electronics and photonics. Narrow-band THz radiation can be produced by free-electron lasers and fast diodes. Broadband THz radiation can be produced by thermal sources and, more recently, by table-top laser-driven sources and by short electron bunches in accelerators, but so far only with low power. Here we report calculations and measurements that confirm the production of high-power broadband THz radiation from subpicosecond electron bunches in an accelerator. The average power is nearly 20 watts, several orders of magnitude higher than any existing source, which could enable various new applications. In particular, many materials have distinct absorptive and dispersive properties in this spectral range, so that THz imaging could reveal interesting features. For example, it would be possible to image the distribution of specific proteins or water in tissue, or buried metal layers in semiconductors; the present source would allow full-field, real-time capture of such images. High peak and average power THz sources are also critical in driving new nonlinear phenomena and for pump-probe studies of dynamical properties of materials.

Journal Article↗

Very high power THz radiation at Jefferson Lab.

We report the production of high power (20 W average, approximately 1 MW peak) broadband THz light based on coherent emission from relativistic electrons. We describe the source, presenting theoretical calculations and their experimental verification. For clarity we compare this source with that based on ultrafast laser techniques, and in fact the radiation has qualities closely analogous to those produced by such sources, namely that it is spatially coherent, and comprises short duration pulses with transform-limited spectral content. In contrast to conventional THz radiation, however, the intensity is many orders of magnitude greater due to the relativistic enhancement.

Computer Simulation↗

Disease-specific, patient-assessed measures of health outcome in ankylosing spondylitis: reliability, validity and responsiveness.

OBJECTIVE: To assess the acceptability and measurement properties of four ankylosing spondylitis (AS)-specific, patient-assessed measures of health outcome: AS Quality of Life Questionnaire (ASQoL), Bath AS Disease Activity Index (BASDAI), the Body Chart and the Revised Leeds Disability Questionnaire (RLDQ). METHODS: Instruments were administered by means of a self-completed questionnaire to patients recruited from across the United Kingdom (UK). Instruments were assessed for data quality and scaling assumptions. Where appropriate, dimensionality was assessed using principle component analysis (PCA). Internal consistency reliability was tested using Cronbach's alpha. Test-retest reliability was assessed in those patients reporting no change in AS-specific health at 2 weeks. The convergent validity of the instruments was assessed and scores were correlated with responses to the health transition questions. Responsiveness was assessed for patients reporting change in health at 6 months. RESULTS: The BASDAI and Body Chart have low self-completion rates. Item responses for the RLDQ were skewed towards higher levels of functional ability. PCA supported instrument unidimensionality. Cronbach's alpha ranged from 0.87 (BASDAI) to 0.93 (RLDQ). Test-retest reliability estimates support the use of the ASQoL and RLDQ in individual evaluation (>0.90). Correlations between instruments were in the hypothesized direction; the largest was between the ASQoL and BASDAI (0.79). The BASDAI had the strongest linear relationship, with responses to both specific and general health transition questions (P<0.01). With the exception of the Body Chart, instruments had a stronger relationship with general health transition. The BASDAI was the most responsive instrument. The Body Chart and RLDQ had low levels of responsiveness. CONCLUSION: The instruments have undergone a comprehensive comparative evaluation to assess the measurement properties required for patient-assessed measures of health outcome. Adequate levels of reliability and validity were found for all instruments. The BASDAI and the ASQoL were the most responsive to self-perceived change in health, but the BASDAI had low levels of self-completion.

Adaptation, Physiological↗

Second harmonic FEL oscillation.

We have produced and measured for the first time second harmonic oscillation in the infrared region by a free electron laser. Although such lasing is ideally forbidden, since the gain of a plane wave is zero on axis for an electron beam perfectly aligned with a wiggler, a transverse mode antisymmetry allows sufficient gain in this experiment for lasing to occur. We lased at pulse rates up to 74.85 MHz and could produce over 4.5 W average and 40 kW peak of IR power in a 40 nm FWHM bandwidth at 2925 nm. In agreement with predictions, the source preferentially lased in a TEM01 mode.

Journal Article↗

Technique charts for EC film: direct optical measurements to account for the effects of X-ray scatter.

PURPOSE: To develop a method of measuring technique charts for enhanced contrast (EC) film, to demonstrate how X-ray scatter changes the response of EC film, and to generate technique charts for general use. METHODS AND MATERIALS: We have developed a "digital cassette"-consisting of a metal plate/phosphor screen, a light guide, a photodiode sensor, and an electrometer-that can be used to measure the light generated in the phosphor screen of the film cassette. In turn, these measurements can be used to generate technique charts for EC film. The digital cassette has been used to measure technique charts for 4-MV and 6-MV X-ray beams for a variety of different phantom thicknesses, field sizes, and phantom-to-cassette air gaps. RESULTS AND DISCUSSION: We have observed that the signals generated in an ionization chamber located 9.4 cm behind a 30-cm-thick water-equivalent phantom increase by a factor of 1.9 when the field size is increased from 4 x 4 cm(2) to 40 x 40 cm(2) when irradiated by a 6-MV X-ray beam. However, the change in EC film response is a factor of 3.5 under the same conditions. Irradiations to optimally expose the EC film predicted by the digital cassette differ by up to 82% compared to those predicted by ion chamber measurements. Nevertheless, the technique charts measured using the digital cassette predict the response of the EC film to +/- 0.2 optical density. The overresponse of the EC film is most likely due to low-energy scattered photons, which interact with the high atomic number (Z = 64) phosphor screen of the enhanced contrast localization cassette. Therefore, simple solutions, such as placing a high atomic number material above the enhanced contrast localization cassette, can reduce this contribution by scattered photons to the signal generated in the cassettes. CONCLUSIONS: We have developed a digital cassette that can make more accurate measurements of the technique charts for EC films. Our measurements show that under some conditions, X-ray scatter can generate a large fraction of the signals recorded by the EC film. Technique charts have been generated at 4 MV and 6 MV, and these charts should have universal applicability.

Film Dosimetry↗

Comparative analysis and application of fluorescent protein-tagged connexins.

In order to examine connexin transport, assembly, and turnover in living cells, we tagged green fluorescent protein or its color variants to several members of the connexin family of proteins. When green fluorescent protein was tagged to the carboxyl terminal end of connexin43 (Cx43-GFP), the resulting fusion protein was transported and assembled into functional gap junctions. However, when GFP was tagged to the amino terminal end of Cx43 (GFP-Cx43), this chimera was biosynthesized, transported to the plasma membrane, but failed to form gap junction channels that could transfer Lucifer yellow. Single cells that expressed Cx43-GFP were capable of transporting this fusion protein to the cell surface in the absence of cell-cell contact. Imaging of Cx43-yellow (Y)FP (Cx43-YFP) was quite efficient; however, the low quantum yield Cx43-BFP and the requirement for ultraviolet excitation made this chimera less suitable for time-lapse imaging. Cx43-cyan C(FP) (Cx43-CFP) was more suitable for imaging than Cx43-blue (B)FP and could be effectively separated from Cx43-YFP. The versatility of tagging GFP to the carboxyl terminal end of other members of the connexin family was established when Cx32-GFP and Cx26-YFP were found to assemble into gap junctions capable of transferring Lucifer yellow. Finally, we are examining the effectiveness of using a new red fluorescent protein (DsRed) fused to connexins in combination with Cx-GFP to simultaneously examine the kinetics, transport and turnover of two connexins. Together, our studies suggest that tagging fluorescent proteins to the carboxyl terminal end of connexins is an effective and valuable approach for studying the life cycle and dynamics of connexins in living cells.

Animals↗

Cortical activations during the mental rotation of different visual objects.

Whole-head functional magnetic resonance imaging was applied to nine healthy right-handed subjects while they were performing three different mental rotation tasks and two visual control tasks. The mental rotation tasks comprised stimuli pairs derived from the "classical" 3D cube figures first used by R. N. Shepard and J. Metzler (1971, Science 171, 701-703), pairs of letters, and pairs of abstract figures developed by J. Hochberg and L. Gellmann (1977, Memory Cognit. 5, 23-26). In some cases, the paired objects were identical except that they were rotated in a certain plane. In other cases, the two objects were incongruent. Subjects were shown one pair of objects at a time and asked to judge whether the two were the same. In line with previous studies we found that decision times increased linearly with the degree of separation between the two objects. Cortical activation converged to demonstrate bilateral core regions in the superior and inferior parietal lobe (centered on the intraparietal sulcus), which were similarly activated during all three mental rotation tasks. Thus, our results suggest that different kinds of stimuli used for mental rotation tasks did not inevitably evoke activations outside the parietal core regions. For example we did not find any activation in brain areas known to be involved in lexical or verbal processing nor activations in cortical regions known to be involved in object identification or classification.

Adult↗

The origin of annular junctions: a mechanism of gap junction internalization.

Gap junctional intercellular communication is established when connexin proteins oligomerize into connexon hemichannels, which then pair at the cell surface with connexons from neighboring cells to form functional gap junction channels. Gap junction channels routinely cluster into gap junction plaques, which can exhibit dynamic characteristics while under the frequent processes of formation and removal from the cell surface. We have three lines of evidence to suggest that one mechanism of gap junction removal occurs when one of two contacting cells internalizes the gap junction contribution from both cells. First, in coculture experiments, green fluorescent protein-tagged connexin43 (Cx43-GFP) expressed in normal rat kidney (NRK) cells can be internalized into contacting cells that do not express Cx43-GFP, and the incidences of identifying these internalized structures increase in the presence of lysosomal inhibitors. Secondly, time-lapse imaging of live NRK cells revealed that large areas of gap junction plaques containing Cx43-GFP were internalized as vesicular-like structures into one of two adjacent cells. Finally, when live NRK cells that express endogenous Cx43 were microinjected with anti-Cx43 antibodies, antibody-tagged gap junctions were visualized in cells that contacted the microinjected cell within 3-6.5 hours. Together our results strongly suggest that one mechanism of gap junction removal from the cell surface involves a unique process in which the entire gap junction or a fragment of it is internalized into one of the two contacting cells as an annular junction.

Animals↗