Design and modeling of inversion layer ultrasonic transducers using LiNbO3 single crystal.

Using inversion domain engineering controlled by heating temperature, the LiNbO(3) (LNO) piezoelectric plate with both odd and even-order thickness-extensional modes can be excited simultaneously. Therefore, the inversion layer ultrasound transducer is expected to be capable of operating over a wider frequency range. In this paper, the electrical impedance and the acoustic characteristics of LiNbO(3) (LNO) inversion layer transducer have been studied by finite element modeling (FEM). The transducer designed for this study uses a 36 degrees rotated Y-cut LiNbO(3) thin plate with an active element thickness of approximately 100 microm. First the electrical and elastic properties of the 36 degrees rotated Y-cut LNO were obtained by transforming a basic piezoelectric matrix for Z-cut LNO. In order to validate the FEM using the transformed properties several pieces of pure and 50% inversion layer LNO were tested on the electrical impedance analyzer. The modeled impedance characteristics were consistent with the measured data. Next the model was used to design 50-60 MHz transducers using pure and 30% inversion LNO. Two lambda/4 matching layers and a Tungsten loaded epoxy backing were used in these designs. The modeled results show that an over 90% bandwidth transducer can be made with proper matching and 30% inversion layer.

Computer Simulation↗

Coded excitation using biphase-coded pulse with mismatched filters for high-frequency ultrasound imaging.

A scheme of using phase-coded excitation and mismatched filter compression for high-frequency ultrasound imaging is presented in this paper. Biphase-coded pulses were constructed to excite the transducer. Received signals were compressed with mismatched filters optimized by minimizing peak-sidelobe-level (PSL). Both simulation and experiments were carried out to demonstrate the advantage of this technique. The simulation results demonstrated a possible sidelobe reduction (<-90 dB) with a slightly decrease of the signal-to-noise ratio of less than 1 dB compared with the compression using matched filters alone. The experimental results showed about 14 dB SNR improvement as well as -40 dB sidelobe level when the Barker-13 code excitation with 3-cycle sinusoidal wave carrier was used.

Acoustics↗

Effect of ultrasonic attenuation on the feasibility of acoustic tweezers.

A modified mathematical formulation for the calculation of axial radiation force was developed to incorporate the effect of ultrasonic attenuation. Axial forces, Fresnel coefficients, average internal attenuation factors and effective internal reflection coefficients were calculated. Thermal and mechanical indices were also computed to address the safety issues in the implementation of acoustic tweezers and were found to be negligible. The results show that the overall distribution of axial forces is barely affected by attenuation. Furthermore, it is found that attenuation actually works against the scattering force and may therefore reinforce the axial trapping force. For a particle size of 180 microm, the maximum trapping force increases from 29.8 x 10(-11) N to 30.3 x 10(-11) N by 1.7% when attenuation is included. In light of these results, it appears that acoustic tweezers may still be feasible beyond the focal point even under the influence of attenuation.

Animals↗

Development of a 35-MHz piezo-composite ultrasound array for medical imaging.

This paper discusses the development of a 64-element 35-MHz composite ultrasonic array. This array was designed primarily for ocular imaging applications, and features 2-2 composite elements mechanically diced out of a fine-grain high-density Navy Type VI ceramic. Array elements were spaced at a 50-micron pitch, interconnected via a custom flexible circuit and matched to the 50-ohm system electronics via a 75-ohm transmission line coaxial cable. Elevation focusing was achieved using a cylindrically shaped epoxy lens. One functional 64-element array was fabricated and tested. Bandwidths averaging 55%, 23-dB insertion loss, and crosstalk less than -24 dB were measured. An image of a tungsten wire target phantom was acquired using a synthetic aperture reconstruction algorithm. The results from this imaging test demonstrate resolution exceeding 50 microm axially and 100 microm laterally.

Ceramics↗

High-frequency ultrasound annular-array imaging. Part I: array design and fabrication.

This is Part I of a series of two papers describing the development of a digital high-frequency, annular-array, ultrasonic imaging system. In this paper, the design and fabrication of a high-frequency annular array as well as its performance will be reported. A six-element, 50 MHz array, which incorporated an acoustic lens to provide an initial focal point, was designed and fabricated. A submicron size grain lead titanate piezoelectric ceramic was used to both reduce lateral coupling and keep the electrical impedance matched close to the 50 ohm receive electronics. The array elements were isolated using laser micromachining to fully separate the annuli, and electrical interconnection was achieved by directly soldering thin wires to the elements. The resulting array attained an average impulse response that exhibited a 43 MHz center frequency, 30% relative bandwidth, and an average insertion loss of 31 dB at 45 MHz. Maximum next-element crosstalk was -27 dB in water.

Computer-Aided Design↗

High-frequency ultrasound annular array imaging. Part II: digital beamformer design and imaging.

This is the second part of a two-paper series reporting a recent effort in the development of a high-frequency annular array ultrasound imaging system. In this paper an imaging system composed of a six-element, 43 MHz annular array transducer, a six-channel analog front-end, a field programmable gate array (FPGA)-based beamformer, and a digital signal processor (DSP) microprocessor-based scan converter will be described. A computer is used as the interface for image display. The beamformer that applies delays to the echoes for each channel is implemented with the strategy of combining the coarse and fine delays. The coarse delays that are integer multiples of the clock periods are achieved by using a first-in-first-out (FIFO) structure, and the fine delays are obtained with a fractional delay (FD) filter. Using this principle, dynamic receiving focusing is achieved. The image from a wire phantom obtained with the imaging system was compared to that from a prototype ultrasonic backscatter microscope with a 45 MHz single-element transducer. The improved lateral resolution and depth of field from the wire phantom image were observed. Images from an excised rabbit eye sample also were obtained, and fine anatomical structures were discerned.

Animals↗

Development of a real-time, high-frequency ultrasound digital beamformer for high-frequency linear array transducers.

A real-time digital beamformer for high-frequency (>20 MHz) linear ultrasonic arrays has been developed. The system can handle up to 64-element linear array transducers and excite 16 channels and receive simultaneously at 100 MHz sampling frequency with 8-bit precision. Radio frequency (RF) signals are digitized, delayed, and summed through a real-time digital beamformer, which is implemented using a field programmable gate array (FPGA). Using fractional delay filters, fine delays as small as 2 ns can be implemented. A frame rate of 30 frames per second is achieved. Wire phantom (20 microm tungsten) images were obtained and -6 dB axial and lateral widths were measured. The results showed that, using a 30 MHz, 48-element array with a pitch of 100 microm produced a -6 dB width of 68 microm in the axial and 370 microm in the lateral direction at 6.4 mm range. Images from an excised rabbit eye sample also were acquired, and fine anatomical structures, such as the cornea and lens, were resolved.

Computer Systems↗

Development of a high-frequency (> 50 mhz) copolymer annular-array, ultrasound transducer.

The development of a high frequency (> 50 MHz) annular array ultrasonic transducer is presented. The array was constructed by bonding a 9 microm P(VDF-TrFE) film to a two-sided polyimide flexible circuit with annuli electrodes on the top layer. Each annulus was separated by a 30 microm kerf and had several electroplated microvias that connected to electrode traces on the bottom side of the flex circuit. In order to improve device sensitivity, each element was electrically matched to an impedance magnitude of 50 omega and 0 degrees phase at resonance using a serial inductor and high impedance coaxial cable. The array's performance was evaluated by measuring the electrical impedance, pulse echo response, and cross talk between elements. The average round trip insertion loss was -33.5 dB after compensating for diffractive and attenuative losses. The measured average center frequency and bandwidth for an element was 55 MHz and 47%, respectively. The measured cross talk between adjacent elements remained below -29 dB at the center frequency in water. A vertical wire phantom was imaged using a single focus transmit beamformer and dynamic focusing receive beamformer. This image showed a significant improvement in lateral resolution over a range of 9 mm after the dynamic focusing receive algorithm was applied. These results correlated well with predictions from a Field II simulation. After beamforming, the minimum lateral resolution achieved by the array (-6 dB) was 108 microm at the focus.

Journal Article↗

Radiation forces exerted on arbitrarily located sphere by acoustic tweezer.

In a previous paper acoustic radiation force on a lipid sphere in a 100-MHz focused Gaussian field was calculated to demonstrate the acoustic tweezer effect near the focus. The theoretical formulation was based on the situation where the sphere is centered along the beam axis. Given intensity distribution independent of the x axis, it was then approximated by a cylindrical model for the sake of simplicity. Only the axial forces were considered because no lateral forces exist due to an object's symmetry. However, it was difficult to employ the same technique to the more general case when it is off the beam axis. To overcome the limitation, in this paper the previous model is modified to compute two additional lateral forces by carrying out the projection over arbitrary incident planes to restrict the integration limits. For different sizes of the sphere, the magnitudes of the net forces in three orthogonal directions are computed. The results show that the acoustic tweezer can be realized more easily in the lateral directions than in the axial directions. Differing from the axisymmetric case, the spheres of small sizes tend to be more strongly attracted than the larger ones in the lateral directions.

Acoustics↗

75 MHz ultrasound biomicroscopy of anterior segment of eye.

Very high frequency ultrasound (35-50 MHz) has had a significant impact upon clinical imaging of the anterior segment of the eye, offering an axial resolution as small as 30 microm. Higher frequencies, while potentially offering even finer resolution, are more affected by absorption in ocular tissues and even in the fluid coupling medium. Our aim was to develop and apply improved transducer technology utilizing frequencies beyond those routinely used for ultrasound biomicroscopy of the eye. A 75-MHz lithium niobate transducer with 2 mm aperture and 6 mm focal length was fabricated. We scanned the ciliary body and cornea of a human eye six years post-LASIK. Spectral parameter images were produced from the midband fit to local calibrated power spectra. Images were compared with those produced using a 35 MHz lithium niobate transducer of similar fractional bandwidth and focal ratio. The 75-MHz transducer was found to have a fractional bandwidth (-6 dB) of 61%. Images of the post-LASIK cornea showed higher stromal backscatter at 75 MHz than at 35 MHz. The improved lateral resolution resulted in better visualization of discontinuities in Bowman's layer, indicative of microfolds or breaks occurring at the time of surgery. The LASIK surface was evident as a discontinuity in stromal backscatter between the stromal component of the flap and the residual stroma. The iris and ciliary body were visualized despite attenuation by the overlying sclera. Very high frequency ultrasound imaging of the anterior segment of the eye has been restricted to the 35-50 MHz band for over a decade. We showed that higher frequencies can be used in vivo to image the cornea and anterior segment. This improvement in resolution and high sensitivity to backscatter from the corneal stroma will provide benefits in clinical diagnostic imaging of the anterior segment.

Adult↗

Boundary element simulation of backscattering properties for red blood with high frequency ultrasonic transducers.

High frequency ultrasonic imaging (e.g. >30 MHz) from blood is difficult due to its tenuous backscattered pressure and the interference from adjacent tissues as well. To increase the sensitivity focused transducer has to be used, thus raising the complexity of interpreting the received signals. A numerical simulation of the ultrasonic scattering property from erythrocyte and rouleaux based on boundary element method was performed with experimental results based on a modified substitution method. The results (proportional relationship between backscattered pressure and frequency and the frequency limit for Rayleigh scattering) closely coincide with experimental data for erythrocyte. Rouleaux model results also show the dependence of degree of red cell aggregation on backscattering properties. The boundary element method serves as a good means to calculate the acoustic scattering from blood cells under arbitrary incident waves.

Blood↗

Half-thickness inversion layer high-frequency ultrasonic transducers using LiNbO3 single crystal.

Half-thickness inversion layer high-frequency ultrasonic transducers were fabricated using lithium niobate (LiNbO3) single crystal plate. The transducers developed for this study used a 36 degrees rotated Y-cut LiNbO3 thin plate with an active element thickness of 115 microm. The designed center frequency was in the range of 30 to 60 MHz. Half-thickness inversion layer was formed after the sample was annealed at a high temperature, and it is shown that the inversion layer thickness can be controlled by the temperature. Silver powder/epoxy composite and parylene were used as acoustic matching layers. A lossy silver epoxy was used as the backing material. Using an analytical method, the electrical impedance for different inversion layer ratios was determined. The measured resonant frequency was consistent with the modeled data. Even-order higher frequency broadband ultrasonic transducers with a center frequency at 60 MHz was obtained using half-thickness inversion layer of LiNbO3 single crystal.

Journal Article↗

Fabrication and characterization of micromachined high-frequency tonpilz transducers derived by PZT thick films.

Miniaturized tonpilz transducers are potentially useful for ultrasonic imaging in the 10 to 100 MHz frequency range due to their higher efficiency and output capabilities. In this work, 4 to 10-microm thick piezoelectric thin films were used as the active element in the construction of miniaturized tonpilz structures. The tonpilz stack consisted of silver/lead zirconate titanate (PZT)/lanthanum nickelate (LaNiO3)/silicon on insulator (SOI) substrates. First, conductive LaNiO3 thin films, approximately 300 nm in thickness, were grown on SOI substrates by a metalorganic decomposition (MOD) method. The room temperature resistivity of the LaNiO3 was 6.5 x 10(-6) omega x m. Randomly oriented PZT (52/48) films up to 7-microm thick were then deposited using a sol-gel process on the LaNiO3-coated SOI substrates. The PZT films with LaNiO3 bottom electrodes showed good dielectric and ferroelectric properties. The relative dielectric permittivity (at 1 kHz) was about 1030. The remanent polarization of PZT films was larger than 26 microC/cm2. The effective transverse piezoelectric e31,f coefficient of PZT thick films was about -6.5 C/m2 when poled at -75 kV/cm for 15 minutes at room temperature. Enhanced piezoelectric properties were obtained on poling the PZT films at higher temperatures. A silver layer about 40-microm thick was prepared by silver powder dispersed in epoxy and deposited onto the PZT film to form the tail mass of the tonpilz structure. The top layers of this wafer were subsequently diced with a saw, and the structure was bonded to a second wafer. The original silicon carrier wafer was polished and etched using a Xenon difluoride (XeF2) etching system. The resulting structures showed good piezoelectric activity. This process flow should enable integration of the piezoelectric elements with drive/receive electronics.

Journal Article↗

An analytical model of multilayer ultrasonic transducers with an inversion layer.

Inversion layer ultrasonic transducers have been investigated recently as an interesting approach in wideband transducer design. In this paper we present an analytical model of multilayer ultrasonic transducers with an inversion layer. Our analysis of the wave propagation problem of an inversion layer transducer includes a functional decomposition of the electrical input impedance. It becomes clear from this decomposition that an inversion layer transducer can be modeled as three elements in series connection, i.e., a clamped capacitance, a classical motional impedance, and a coupled motional impedance. The first two elements make up the classical model of a single element transducer. The coupled motional impedance describes the coupled interaction between the regular and the inverted piezoelectric sublayers, and thus reflects the effect of an inversion layer. We present examples which show that inversion layer transducers are advantageous in achieving such useful features as dual-frequency operation mode as used in harmonic imaging or broadband performance desired in most ultrasonic applications.

Journal Article↗

Characterization of high-frequency, single-element focused transducers with wire target and hydrophone.

In this paper, a wire-target technique was used for lateral beam profile measurements for a single-element, focused transducers in the very high-frequency range (35-60 MHz). Two wire targets made from 9-cm long tungsten wires with diameters of 8 microm and 20 microm were used as the pulse-echo targets to measure the lateral beam profiles at the focal plane of two single-element, focused transducers, a spherically focused 40 MHz transducer and a lens-focused in-house lithium niobate (LiNbO3) 60 MHz transducer. For comparison, measurements on the same transducers were performed by three small-aperture hydrophones with geometrical diameters varying from 37 microm to 150 microm. Tomographic reconstruction of the acoustic field from the spherically focused transducer also was conducted. Results obtained with the wire-target technique are comparable to those obtained with small-aperture hydrophones in characterizing lateral radiation patterns of a single-element, focused transducer in the high-frequency range (35-60 MHz). However, the wire-target method may overestimate pulse length because of the additional attenuation caused by the return path. Compared to small-aperture hydrophones, the wire-target technique is simpler and more cost effective. Its major advantage, however, is in the frequency range above 100 MHz in which commercial hydrophones are not yet available.

Letter↗

Design and fabrication of broadband graded ultrasonic transducers with rectangular kerfs.

Broadband ultrasound imaging is capable of achieving superior resolution in clinical applications. An effective and easy way of manufacturing broadband transducers is desired for these applications. In this work, a graded material in which the piezoelectric plate is mechanically graded with rectangular grooves is introduced. Finite element analysis (FEA) demonstrated that the graded piezoelectric material could achieve a broadband, time-domain response resulting from multiple resonant modes. Experimental tests were carried out to validate these theoretical results. Based upon the FEA designs, several single-element transducers were fabricated using either a nondiced ceramic or a diced, graded ceramics. A superior bandwidth of 92% was achieved by the graded transducer when compared to a bandwidth of 56% produced by the nondiced ceramic transducer at the expense of a reduced sensitivity.

Ceramics↗

A theoretical study of the feasibility of acoustical tweezers: ray acoustics approach.

The optical tweezer has been found to have many biomedical applications in trapping macromolecules and cells. For the trapping mechanism, there has to be a sharp spatial change in axial optical intensity and the particle size must be much greater than the wavelength. Similar phenomenon may exist in acoustics. This work was undertaken to demonstrate theoretically that it is possible to acoustically trap particles near the focal point where most of the acoustic energy is concentrated if certain conditions are met. Acoustic force exerted on a fluid particle in ultrasonic fields is analyzed in a ray acoustics regime where the wavelength of acoustic beam is much smaller than the size of the particle. In order to apply the acoustical tweezer to manipulating macromolecules and cells whose size is in the order of a few microns or less, a prerequisite is that the ultrasound wavelength has to be much smaller than a few microns. In this paper, the analysis is therefore based on the field pattern produced by a strongly focused 100 MHz ultrasonic transducer with Gaussian intensity distribution. For the realization of acoustic trapping, negative axial radiation force has to be generated to pull a particle towards a focus. The fat particle considered for acoustic trapping in this paper has an acoustic impedance of 1.4 MRayls. The magnitude of the acoustic axial radiation force that has been calculated as the size of the fat particle is varied from 8lambda to 14lambda. In addition, both Fresnel coefficients at various positions are also calculated to assess the interaction of reflection and refraction and their relative contribution to the effect of the acoustical tweezer. The simulation results show that the feasibility of the acoustical tweezer depends on both the degree of acoustic impedance mismatch and the degree of focusing relative to the particle size.

Acoustics↗

Interlaboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz.

OBJECTIVE: As are the attenuation coefficient and sound speed, the backscatter coefficient is a fundamental ultrasonic property that has been used to characterize many tissues. Unfortunately, there is currently far less standardization for the ultrasonic backscatter measurement than for the other two, as evidenced by a previous American Institute of Ultrasound in Medicine (AIUM)-sponsored interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements (J Ultrasound Med 1999; 18:615-631). To explore reasons for these disparities, the AIUM Endowment for Education and Research recently supported this second interlaboratory comparison, which extends the upper limit of the frequency range from 7 to 9 MHz. METHODS: Eleven laboratories were provided with standard test objects designed and manufactured at the University of Wisconsin (Madison, WI). Each laboratory was asked to perform ultrasonic measurements of sound speed, attenuation coefficients, and backscatter coefficients. Each laboratory was blinded to the values of the ultrasonic properties of the test objects at the time the measurements were performed. RESULTS: Eight of the 11 laboratories submitted results. The range of variation of absolute magnitude of backscatter coefficient measurements was about 2 orders of magnitude. If the results of 1 outlier laboratory are excluded, then the range is reduced to about 1 order of magnitude. Agreement regarding frequency dependence of backscatter was better than reported in the previous interlaboratory comparison. For example, when scatterers were small compared with the ultrasonic wavelength, experimental frequency-dependent backscatter coefficient data obtained by the participating laboratories were usually consistent with the expected Rayleigh scattering behavior (proportional to frequency to the fourth power). CONCLUSIONS: Greater standardization of backscatter measurement methods is needed. Measurements of frequency dependence of backscatter are more consistent than measurements of absolute magnitude.

1-Propanol↗