Effective dose in sentinel lymph node imaging.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to K Knesaurek.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We compared two correction methods for simultaneous 201Tl/99mTc dual-isotope single-photon emission computed tomography (SPECT). Both approaches use the information from the third energy window placed between the photopeak windows of the 201Tl and 99mTc. The first approach, described by Moore et al, corrects only for the contribution of the 99mTc to the 201Tl primary 70 keV window. We developed the three-window transformation dual isotope correction method, which is a simultaneous cross-talk correction. The two correction methods were compared in a simultaneous 201Tl/99mTc sestamibi cardiac dog study. Three separate acquisitions were performed in this dog study: two single-isotope and one dual-isotope acquisition. The 201Tl single-isotope images were used as references. The total number of counts, and the contrast between the left ventricular cavity (LVC) and the myocardium, were used in 70 keV short axis slices as parameters for evaluating the results of the dual-isotope correction methods. Three consecutive short-axis slices were used to calculate averaged contrast and the averaged total number of counts. The total number of the counts was 667000+/-500 and 414500+/-400 counts for the dual isotope (201Tl+/-99mTc) and single-isotope (201Tl-only) 70 keV images, respectively. The corrected dual-isotope images had 514700+/-700 and 368000+/-600 counts for Moore's correction and our approach, respectively. Moore's method improved contrast in the dual isotope 70 keV image to 0.14+/-0.03 from 0.11+/-0.02, which was the value in the 70 keV non-corrected dual-isotope image. Our method improved the same contrast to 0.22+/-0.03. The contrast in the 201Tl single-isotope 70 keV image was 0.28+/-0.02. Both methods improved the 70 keV dual-isotope images. However, our approach provided slightly better images than Moore's correction when compared with 201Tl-only 70 keV images.
Collimated F-18 FDG SPECT imaging has been shown to be an acceptable alternative to F-18 FDG PET imaging for evaluating injured but viable myocardium. Ultra-energy (UHE) imaging is usually performed in simultaneous F-18 FDG/Tc-99m MIBI studies. The main limitations of this technique are degradation of the Tc-99m MIBI images due to F-18 downscatter to the Tc-99m window, and loss of resolution in Tc-99m images caused by using a UHE rather than a low-energy collimator. The quality of F-18 images has not been addressed. In our clinical and phantom studies we have found that F-18 images are inferior to simultaneously acquired Tc-99m MIBI images. This paper compares two correction methods for F-18 FDG images in a realistic cardiac phantom study. One approach is subtractive scatter correction, which employs a third 410 keV energy window image to estimate scatter. The other approach is based on restoration. The phantom acquisition was performed with 7.2 MBq of F-18 and 22.2 MBq of Tc-99m injected into the left ventricular (LV) wall. Three inserts, 3 cm, 2 cm, and 1 cm in diameter, were placed in the LV wall to simulate infarcts. Circumferential profiles were drawn from three successive short-axis slices and compared with true phantom data. The differences were calculated as root-mean-square error (rmse). Scatter correction improved rmse only 4.5 +/- 0.3%, while restoration improved rmse 16.1 +/- 0.4%, when compared with raw data. The same differences, measured as rmse, were 9.5 +/- 0.5, 6.8 +/- 0.4, and 5.1 +/- 0.5 for raw, scatter corrected, and restored F-18 data, respectively, when compared with Tc-99m window 140 keV data. The amount of noise, measured as root-mean-square % (rms%) was 5.3 +/- 0.5% for the Tc-99m image, 4.9 +/- 0.7% for the F-18 restored image, 6.2 +/- 0.6% for the raw F-18 image, and 6.5 +/- 0.9% for the scatter corrected F-18 image. The contrast measured for 2 cm and 3 cm inserts was 0.17 +/- 0.07 and 0.26 +/- 0.06 for F-18 raw data, 0.19 +/- 0.08 and 0.29 +/- 0.06 for the scatter corrected F-18 image, and 0.28 +/- 0.06 and 0.43 +/- 0.07 for the restored F-18 image. The contrast was 0.20 +/- 0.07 and 0.46 +/- 0.05 for the Tc-99m 140 keV window image. The restoration approach provided F-18 images of better contrast and detectibility than uncorrected or scatter corrected F-18 images. Restored F-18 images match better with the simultaneously acquired Tc-99m images.
We have developed a novel transformation method for the correction of cross-talk in simultaneous dual radionuclide single photon emission CT (SPECT) imaging. It is based on the assumption that the transformations, which transform the primary energy window images into the scatter images as viewed in the other energy windows, are known. The method was tested on a dog model. These transformations were found by measuring the point response functions (prf) in different energy windows for both radionuclides in water. The dual radionuclide correction method described takes into account the different spatial distributions of the primary and scatter cross-talk photons in different energy windows. This method also includes the sequential application of restoration filters to the resulting cross-talk corrected images. We used a dog model in three separate studies: two single radionuclide studies used as references and one dual radionuclide study. Contrast between the left ventricular cavity (LVC) and the myocardium was used in horizontal long axis (HLA) slices as a parameter to evaluate the results of the dual radionuclide correction method with restoration. The increase of the contrast in the dual radionuclide corrected images in both energy windows, i.e. 201Tl primary window (70 keV) and 99Tcm primary window (140 keV), was significant. The cross-talk corrected 70 keV dual radionuclide HLA slice had a contrast of 0.62 compared with 0.35, which was the value in the non-corrected dual radionuclide HLA slice. Restoration improved the contrast to 0.68. In the single radionuclide 201Tl image, the same contrast was 0.59, improving to 0.70 after restoration. For the dual radionuclide 140 keV HLA slice, the contrast increased from 0.69 to 0.76 after cross-talk correction. Additional increase of the contrast to 0.83 resulted from restoration filtering. In the single radionuclide 99Tcm sestamibi 140 keV HLA slice the improvement of contrast was from 0.63 to 0.86 as a result of the restoration. The transformation three-window, dual radionuclide correction method with restoration improves the quality of the simultaneous rest 201Tl/stress 99Tcm sestamibi SPECT imaging.
BACKGROUND: Magnetic resonance imaging and positron emission tomography were used to study the size and metabolic rate of the caudate and the putamen in 18 patients with schizophrenia (n=16) or schizo-affective disorder (n=2) and 24 age- and sex-matched control subjects. METHODS: The patients were either never medicated (n=7) or drug free (n=11) for a median of 3 weeks. During uptake of fludeoxyglucose F 18, all patients performed a serial verbal learning test. Positron emission tomographic and magnetic resonance imaging scans were coregistered, and the caudate and the putamen were traced on the magnetic resonance image. RESULTS: The striatum had a significantly lower relative metabolic rate in schizophrenics than in controls. Never-medicated patients had lower metabolic rates in the right putamen (ventral part of the dorsal striatum) than previously medicated patients. The caudate was significantly smaller in never-medicated patients than in controls and largest in previously medicated patients. Patients with higher relative metabolic rates in the putamen scored higher on the Abnormal Involuntary Movements Scale. CONCLUSIONS: The findings are consistent with reports of striatal enlargement in previously medicated patients and size increases after neuroleptic treatment. Never-medicated patients, in contrast, had ventral striatal structures that were smaller and less active than those observed in controls and previously medicated patients.
We describe a non-uniform iterative attentuation correction method for single photon emission tomography (SPET) which uses transmission data. The method was derived using the general inverse problem theory. A cost functional which includes noise was derived and minimized using a weighted-least-square maximum a posteriori conjugate gradient (CG) method. The Hessian of the cost functional was modified by adding a noise term. The a priori value of the model data vector was neglected. The method was tested in a clinical cardiac SPET perfusion study. Prior to the emission scan, blank and transmission scans were acquired and used to obtain the non-uniform map of linear attenuation coefficients. The results of the study show that the new iterative method has a slightly better convergence rate than the standard CG method. Also, the corrected emission slices obtained by the new method were less noisy. Noise was measured as rms% and was reduced by a factor of 2.3 for the transmission scans and by a factor of 1.9 for the emission scans when reconstructed with the new method compared to the CG method. The new method provides a stable solution, whereas the standard CG method, for higher iterative steps, diverges. There is potential for improvement in the approach described here.
A newly developed cross-talk correction method for simultaneous dual-isotope SPECT imaging was tested in a canine model. The method is based on the assumption that the transformations, which modify the primary energy window images into the scatter images as viewed in the other energy windows, are known. These transformations were found by measuring the point spread functions (PSFs) in two different energy windows for both isotopes in water. The dual-isotope correction method is described by two convolution equations which were applied in frequency space. The equations take into account the different spatial distributions of the primary and scatter cross-talk photons. The new enhancement of the method was in applying restoration filters to the resulting corrected images. Three separate studies were acquired in our dog study: two single-isotope and one dual-isotope study. The single isotope images were used as references. The contrast between the left ventricle cavity (LVC) and the myocardium was used in transaxial and short-axis slices as a parameter to evaluate results of dual-isotope correction method with restoration. The change in contrast in the dual-isotope corrected images in both energy windows, i.e., Tc-99m primary window (140 keV) and Tl-201 primary window (70 keV), was significant. The only exception was for the short-axis Tc-99m window images. The corrected 140 keV dual-isotope short-axis slice had the contrast of 0.60 vs 0.58, which was the value in the noncorrected dual-isotope short-axis slice. For dual-isotope 140 keV transaxial slice, the contrast changed from 0.72 to 0.82 after correction. In comparison, for single-isotope Tc-99m 140 keV transaxial slice, contrast changed from 0.62 to 0.84 after restoration correction. There was less change in contrast in the short-axis Tc-99m 140 keV slice, i.e., from 0.56 to 0.61. In the Tl-201 primary window for the transaxial slices the improvement of contrast was from 0.38 to 0.64, and for short-axis slices from 0.22 to 0.32 after correction. In the same 70 keV energy window for single-isotope Tl-201 images, contrast improved from 0.61 to 0.69 and from 0.35 to 0.38 for transaxial and short-axis slice, respectively, after applying restoration correction. In conclusion, the presented dual-isotope correction method with restoration improves the quality of the simultaneous rest Tl-201/stress Tc-99m sestamibi SPECT imaging.
UNLABELLED: We developed and tested a new transformation cross-talk correction method for simultaneous dual-isotope SPECT imaging, which uses information from three energy windows in a simultaneous 18F/99mTc cardiac phantom study. METHODS: The method combines the previously reported "three-window" technique and transformation cross-talk correction methods. In the three-window technique, the images from the third energy "scatter" window are usually multiplied by a constant factor to obtain the estimates of the cross-talk. However, such an approach neglects differences in the spatial distribution between cross-talk photons in different energy windows. The transformation method is based on the assumption that the transformations, which convert the images from one energy window into the other energy windows, are known. These transformations were found by measuring the point-spread functions in different energy windows for both isotopes in water. The transformation method takes into account the different spatial distributions of the primary and scatter cross-talk photons in the different energy windows. Here, we are assuming that the imaging system and the image transformations between different energy windows are shift-invariant and linear. Thus, the new method is described by two convolution equations applied in frequency space. In addition to the cross-talk correction, the restoration filters were also applied to the resulting corrected images. The new method was performed on the simultaneous 18F/99mTc cardiac phantom study. Three separate studies were acquired in our phantom study: two single-isotope studies and one dual-isotope study. The single-isotope images were used as references. The contrast between the left ventricle cavity and the myocardium was used in transaxial slices as a parameter to evaluate results of the dual-isotope correction method with restoration. RESULTS: The contrast improvement in the dual-isotope corrected images in both energy windows, i.e., the 99mTc primary window (140 keV) and the 18F primary window (511 keV), was significant. The corrected 511-keV, dual-isotope image had a contrast of 0.74 compared to 0.60, which was the value in the noncorrected dual-isotope image. The improvement of the contrast in the corrected, dual-isotope 511-keV image was exclusively a result of the restoration correction. The restoration-corrected, 511-keV, single-isotope 18F image had the same contrast (0.74). For the dual-isotope, 140-keV transaxial slice, first, the contrast improved from 0.78 to 0.85 after cross-talk correction, and, then, it finally reached 0.92 after additional restoration correction. The contrast in the 140-keV, single-isotope 99mTc image after restoration correction improved from 0.87 to 0.95. CONCLUSION: The three-window transformation dual-isotope correction method with restoration significantly improves the contrast between the left ventricle cavity and the myocardium of the simultaneous 18F/99mTc SPECT imaging.
A new iterative reconstruction technique (NIRT) for positron emission computed tomography (PET), which uses transmission data for nonuniform attenuation correction, is described. Utilizing the general inverse problem theory, a cost functional which includes a noise term was derived. The cost functional was minimized using a weighted-least-square maximum a posteriori conjugate gradient (CG) method. The procedure involves a change in the Hessian of the cost function by adding an additional term. Two phantoms were used in a real data acquisition. The first was a cylinder phantom filled with uniformly distributed activity of 74 MBq of fluorine-18. Two different inserts were placed in the phantom. The second was a Hoffman brain phantom filled with uniformly distributed activity of 7.4 MBq of 18F. Resulting reconstructed images were used to test and compare a new iterative reconstruction technique with a standard filtered backprojection (FBP) method. The results confirmed that NIRT, based on the conjugate gradient method, converges rapidly and provides good reconstructed images. In comparison with standard results obtained by the FBP method, the images reconstructed by NIRT showed better noise properties. The noise was measured as rms% noise and was less, by a factor of 1.75, in images reconstructed by NIRT than in the same images reconstructed by FBP. The distance between the Hoffman brain slice reconstructed by FBP and the perfect PET Hoffman brain slice created from the MRI image was 0.526, while the same distance for the Hoffman brain slice reconstructed by NIRT was 0.328. The NIRT method suppressed the propagation of the noise without visible loss of resolution in the reconstructed PET images.
Simultaneous dual-isotope SPECT imaging provides a clear advantage in situations where two concurrent metabolic, anatomic, or background measurements are desired. It obviates the need for two separate imaging sessions, reduces patient motion problems, and provides exact image registration between images. However, a potential limitation of dual-isotope SPECT imaging is contribution of scattered and primary photons from one radionuclide into the second radionuclide's photopeak energy window, referred to here as cross-talk. Cross-talk in both photopeak energy windows can significantly degrade image quality, resolution, and quantitation to an unacceptable level. Simple cross-talk correction method used in dual-radionuclide in vitro counting, even applied on a pixel-by-pixel basis, does not account for the differences in spatial distribution of the photopeak and cross-talk photons. Here a new convolution cross-talk correction method is presented. The convolution filters are derived from point response functions (PRFs) for Tc-99m and Tl-201 point sources. Three separate acquisitions were performed, each with two 20% wide energy windows, one centered at 140 keV and another at 70 keV. The first acquisition was done with Tc-99m solution only, the second with Tl-201 solution only, and the third with a mixture of Tc-99m and Tl-201. The nonuniform RH-2 thorax-heart phantom was used to test a new correction technique. The main difficulty and limitation of the convolution correction approach is caused by the variation in PRF as a function of depth. Thus, average PRF should be used in the creation of an approximative filter.(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
To investigate geometric distortion when 180 degrees or 360 degrees angular sampling techniques are used in single photon emission computed tomography (SPECT), a study of point sources imaged at different positions in a water filled cylindrical phantom, and reconstructed using filtered back projection, was conducted. A simulation study, based upon a serial model of the system point spread function (PSF), was used to investigate the contributions of attenuation, spatial resolution and scatter on distortion of the reconstructed PSFs. To study the geometric distortion in transverse (x-y plane), coronal (x-z plane), and sagittal (y-z plane) sections, the ratios of the full widths at half maximum (FWHM) and full widths at tenth maximum (FWTM) in the x/y, x/z, and y/z directions were calculated for the real and simulated PSFs. These results showed that, in an attenuating medium, there is more distortion of point sources into ovals for 180 degrees than for 360 degrees sampling. The simulation study indicated that the primary cause of geometrical distortion in SPECT studies, is the inconsistency of projections due to variable attenuation and spatial resolution. The impact of scatter on geometric distortion was small as measured by the ratios of FWHMs and FWTMs for PSFs. Attenuation correction applied to acquired PSFs significantly reduced geometric distortion in both 180 degrees and 360 degrees studies. To investigate distortion in extended objects, an Iowa heart phantom was placed inside an Alderson body phantom and 201Tl heart SPECT studies acquired. The phantom images confirmed the conclusion that in transverse sections of 360 degrees studies with arithmetic averaging of opposite views, geometric distortion is reduced compared to 180 degrees. The coronal and sagittal sections were equally distorted in both, the 180 degrees and 360 degrees studies, and the 180 degrees studies yielded better contrast.
The problem of using 360 degrees or 180 degrees data sampling techniques in transaxial SPECT imaging is still to be solved. A theoretical point source study for an ideal response detector has shown, for objects which are close enough to the origin of the reconstructed area, that there are significant differences between sections obtained by different sampling methods. A computer simulation study of line sources in a homogeneous attenuated medium has confirmed the results of clinical studies in which significant image distortion has been observed in 180 degrees sections but not in 360 degrees reconstructed images.
Explore the source record for details and available documents.
The importance of comparing various deconvolution techniques on real patient data lies in the fact that there are two different approaches to that problem. One, which prefers general-purpose techniques, using a matrix algorithm (MA) and fast-Fourier transformation (FFT) with various smoothings, filters, etc., and another which prefers deconvolution techniques which have been modified for the particular application. The modification may be in requiring well defined input or assuming a smooth result of deconvolution. The aim of this paper is to compare the general-purpose deconvolution technique mostly used in analyzing patient data in nuclear medicine using MA and FFT with deconvolution based on Laplace transformation (LT). They have been compared on real patient data renograms in 36 cases. The comparison shows that although the LT technique requires a well defined input and for that reason needs more computing time than the FFT and MA technique, it gives impulse response functions (IRF) without negative values or with negligible ones. Even more, using LT, which has been incorporated in a model of distribution and transport of tracer, without taking blood samples one can assess some other useful clinical parameters such as inverse value of clearance time constant (ICTC) and effective renal plasma flow (ERPF).
Explore the source record for details and available documents.
The single compartment well-mixed model ( SCWMM ) which has been used in almost all dynamic studies in nuclear medicine is, in fact , strictly accurate only in the case of a steady state obtained by means of constant administration of long-lived isotopes. That is the reason why SCWMM is not a good predictor of the behaviour of short-lived isotopes and why the distribution and transport of short- and long-lived isotopes in various situations has not yet been discussed in general terms. The aim of this paper is to do that by means of a more general stochastic approach. This more general approach takes into account the distribution and transport of tracer in the system, not requiring a hypothesis of good mixing and providing a possibility of making corrections due to decay in the case of short-lived isotopes studies.