Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system.

In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To speed up the calculations, a number of calculation techniques were implemented, including separate primary and scatter dose calculation, the FFT technique which assumes kernel invariance for the convolution calculation and a multigrid (MG) acceleration technique for the superposition calculation. Timing results show that the FFTC model is faster than MGS by a factor of 4 and 8 for small and large field sizes, respectively. Comparisons with measured data and BEAM MC results for a wide range of clinical beam setups show that (a) FFTC and MGS doses match measurements to better than 2% or 2 mm in homogeneous media; (b) MGS is more accurate than FFTC in lung phantoms where MGS doses are within 3% or 3 mm of BEAM results and (c) FFTC overestimates the dose in lung by a maximum of 9% compared to BEAM.

Algorithms↗

Three-dimensional photon treatment planning for carcinoma of the nasopharynx.

The role of 3-D treatment planning for carcinoma of the nasopharynx was assessed in a four institution study. Two patients were worked up and had an extensive number of CT scans on which target volumes and normal tissues were defined. Treatment planning was then performed using state of the art dose planning systems for these patients to assess the value of the new technology. In general, it was demonstrated that multi-field conformal plans could achieve good tumor dose coverage, while at the same time reducing normal tissue doses, compared to standard treatment planning techniques. The role of inhomogeneity corrections, beam energy, and the use of CT vs. simulation films for defining target volumes were also discussed. In addition, techniques to evaluate 3-D plans for the nasopharynx were considered, and some analysis of this problem is presented in this paper.

Adult↗