Publications and source records attributed to K L Kilgore.

At least 19 recordsLinked to original sources

A transducer to measure isometric elbow moments.

OBJECTIVE: The purpose of this study was to design and implement a transducer to measure accurately the isometric elbow moments produced by individuals with tetraplegia. DESIGN: The device needed to be insensitive to off-axis moments and proximal joint motions and be capable of being used over a wide range of elbow and shoulder positions in an outpatient clinic setting. BACKGROUND: Measurement of the smaller isometric moments produced by individuals with tetraplegia is especially sensitive to the errors that can be introduced by inaccurate lever arm determination, off-axis loads, and proximal joint motions. Devices traditionally utilized for quantifying isometric strength are difficult to implement for the spinal cord injured population. METHODS: The elbow moment transducer consists of two four-bar parallelogram linkages joined by a lockable pivot. Strain gauges mounted on one beam of the parallelogram produce an output proportional to the elbow moment. RESULTS: Calibration of the device indicates that it accurately quantifies isometric elbow moments over a range that is appropriate for evaluating elbow extension strength in individuals with tetraplegia. CONCLUSIONS: A device was developed and implemented that accurately quantifies isometric elbow moments over a range that is appropriate for evaluating elbow extension strength in individuals with tetraplegia. RELEVANCE: The ability to quantitatively evaluate elbow strength in persons with tetraplegia is useful for understanding and improving the clinical outcomes of rehabilitative interventions that involve the elbow.

Calibration↗

Implanted stimulators for restoration of function in spinal cord injury.

Neuroprostheses that electrically stimulate paralyzed muscles provide functional enhancements for individuals with spinal cord injury and stroke such as standing and stepping, reaching and grasping, and bladder and bowel function. For chronic applications, implanted neuroprostheses lead to reliable, low-maintenance and patient-acceptable systems. The advantages of such systems are discussed followed by a generic description of implantable stimulators. Features of current first and second generation neuroprostheses developed at our centre are discussed followed by our experience in the application of these devices in the rehabilitation of individuals with spinal cord injury.

Arm↗

Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study.

OBJECTIVE: To evaluate an implanted neuroprosthesis that allows tetraplegic users to control grasp and release in 1 hand. DESIGN: Multicenter cohort trial with at least 3 years of follow-up. Function for each participant was compared before and after implantation, and with and without the neuroprosthesis activated. SETTING: Tertiary spinal cord injury (SCI) care centers, 8 in the United States, 1 in the United Kingdom, and 1 in Australia. PARTICIPANTS: Fifty-one tetraplegic adults with C5 or C6 SCIs. INTERVENTION: An implanted neuroprosthetic system, in which electric stimulation of the grasping muscles of 1 arm are controlled by using contralateral shoulder movements, and concurrent tendon transfer surgery. Assessed participants' ability to grasp, move, and release standardized objects; degree of assistance required to perform activities of daily living (ADLs), device usage; and user satisfaction. MAIN OUTCOME MEASURES: Pinch force; grasp and release tests; ADL abilities test and ADL assessment test; and user satisfaction survey. RESULTS: Pinch force was significantly greater with the neuroprosthesis in all available 50 participants, and grasp-release abilities were improved in 49. All tested participants (49/49) were more independent in performing ADLs with the neuroprosthesis than they were without it. Home use of the device for regular function and exercise was reported by over 90% of the participants, and satisfaction with the neuroprosthesis was high. CONCLUSIONS: The grasping ability provided by the neuroprosthesis is substantial and lasting. The neuroprosthesis is safe, well accepted by users, and offers improved independence for a population without comparable alternatives.

Adult↗

Structured sleeve for repair of implantable in-line connectors.

A structured miniature repair sleeve has been designed for implantable in-line connectors that develop small current leaks post-implant. The repair sleeve has been successfully utilised in one subject following the development of current leakage in connectors on an implanted joint angle sensor.

Electric Stimulation Therapy↗

Intrinsic and extrinsic contributions to the passive moment at the metacarpophalangeal joint.

The purpose of this investigation was to determine whether the passive range of motion at the finger joints is restricted more by intrinsic tissues (cross a single joint) or by extrinsic tissues (cross multiple joints). The passive moment at the metacarpophalangeal (MP) joint of the index finger was modeled as the sum of intrinsic and extrinsic components. The intrinsic component was modeled only as a function of MP joint angle. The extrinsic component was modeled as a function of MP joint angle and wrist angle. With the wrist fixed in seven different positions the passive moment at the MP joint of eight subjects was recorded as the finger was rotated through its range at a constant rate. The moment-angle data were fit by the model and the extrinsic and intrinsic components were calculated for a range of MP joint angles and wrist positions. With the MP joint near its extension limit, the median percent extrinsic contribution was 94% with the wrist extended 60 degrees and 14% with the wrist flexed 60 degrees. These percentages were 40 and 88%, respectively, with the MP joint near its flexion limit. Our findings indicate that at most wrist angles the extrinsic tissues offer greater restraint at the limits of MP joint extension and flexion than the intrinsic tissues. The intrinsic tissues predominate when the wrist is flexed or extended enough to slacken the extrinsic tissues. Additional characteristics of intrinsic and extrinsic tissues can be deduced by examining the parameter values calculated by the model.

Adult↗

Reduction of costs of disability using neuroprostheses.

The lifetime costs associated with spinal cord injury are substantial. Assistive technology that reduces complications, increases independence, or decreases the need for attendant services can provide economic as well as medical or functional benefit. This study describes two approaches for estimating the economic consequences of implanted neuroprostheses utilizing functional electrical stimulation. Life care plan analysis was used to estimate the costs of bladder and bowel care with and without a device restoring bladder and bowel function and to compare these with the costs of implementing the device. For a neuroprosthesis restoring hand grasp, the costs of implementation were compared to the potential savings in attendant care costs that could be achieved by the use of the device. The results indicate that the costs of implementing the bladder and bowel system would be recovered in 5 years, primarily from reduced costs of supplies, medications, and procedures. The costs of the hand grasp neuroprosthesis would be recovered over the lifetime of the user if attendant time was reduced only 2 hours per day and in a shorter time if attendant care was further reduced. Neither analysis includes valuation of the quality of life, which is further enhanced by the neuroprostheses through restoration of greater independence and dignity. Our results demonstrate that implantable neuroprosthetic systems provide good health care value in addition to improved independence for the disabled individual.

Bionics↗

Applications of cortical signals to neuroprosthetic control: a critical review.

Cortical signals might provide a potential means of interfacing with a neuroprosthesis. Guidelines regarding the necessary control features in terms of both performance characteristics and user requirements are presented, and their implications for the design of a first generation cortical control interface for a neuroprosthesis are discussed.

Cerebral Cortex↗

EEG-based control of a hand grasp neuroprosthesis.

The feasibility of using the EEG signal to operate a hand grasp neuroprosthesis was investigated. Two able-bodied subjects and one neuroprosthesis user were trained to control the amplitude of the beta rhythm recorded over the frontal areas. After 6 months, all subjects exhibited a high level of control, being able to use this signal to move a cursor to targets on a computer screen with a high (>90%) accuracy rate. Control over the EEG signal was unaffected by upper extremity movement or electrical activation of the muscles, indicating that this signal would be adequate for neuroprosthetic use. To test this concept, the neuroprosthesis user operated his system with the cortical signal, and was able to effectively manipulate several objects.

Adult↗

Satisfaction with and usage of a hand neuroprosthesis.

OBJECTIVE: To measure the satisfaction with, clinical impact of, and use of an implantable hand neuroprosthesis. SETTING: Eight different medical centers. PARTICIPANTS: Thirty-four individuals with spinal cord injuries at the C5 or C6 motor level. INTERVENTIONS: Participants were implemented with a hand neuroprosthesis that provides grasp and release. The neuroprosthesis includes a surgically implanted stimulator, implanted electrodes sutured to the hand and forearm muscles, and an externally mounted controller. MAIN OUTCOME MEASURE: A survey was mailed to study participants, who were asked to respond to statements such as "If I had it to do over, I would have the hand system implanted again," using a 5-level Likert scale ("strongly agree" to "strongly disagree"). RESULTS: Eighty-seven percent of participants were very satisfied with the neuroprosthesis, 88% reported a positive impact on their life, 87% reported improvements in activities of daily living, and 81% reported improved independence. Participants reported using the neuroprosthesis a median of 5.5 days per week; 15 participants used the neuroprosthesis 7 days per week, and 5 participants reported not using the device. CONCLUSIONS: The neuroprosthesis was used by most participants. The neuroprosthesis performed satisfactorily, increased users' ability to perform activities of daily living and independence, and improved their quality of life.

Adolescent↗

The function of the finger intrinsic muscles in response to electrical stimulation.

The actions of the dorsal interosseous, volar interosseous, and lumbrical muscles were investigated using applied electrical stimulation and recording the moments that were generated across the metacarpophalangeal joint in flexion/extension and abduction/adduction, the proximal interphalangeal joint in flexion/extension, and the distal interphalangeal joint in flexion/extension. These measurements were made isometrically at various joint angles and levels of stimulation with both able bodied subjects and persons who had sustained tetraplegia. It was determined that the dorsal interossei, including the first, were strong abductors of the fingers and generated a significant moment in metacarpophalangeal (MP) joint flexion and interphalangeal (IP) joint extension. The volar interossei were the primary adductors of the fingers, as well as providing a significant moment in MP joint flexion and IP joint extension. The lumbrical muscles were found to be MP joint flexors and IP joint extensors, although the moments that were generated were on average 70% lower than the interossei. The role of the lumbricals as finger abductors or adductors could not be determined from the data. This information on the actions and moment generating capabilities of the intrinsic muscles led to the incorporation of the interossei into electrically induced hand grasp provided by an implanted neuroprosthesis. The evaluation of the intrinsic muscles in the neuroprosthesis was accomplished by recording the moment generating capabilities of these muscles across each of the joints of the finger. These muscles were capable of generating moments that were 80-90% of the average attained by the able bodied subjects, and have provided a substantial improvement to the electrically induced hand grasp.

Adult↗

Implantable transducer for two-degree of freedom joint angle sensing.

An implantable joint angle transducer (IJAT) was developed to provide command-control and feedback-control information for chronic use with functional neuromuscular stimulation (FNS) neuroprostheses. The IJAT uses Hall effect sensors to transduce joint angle. A titanium encapsulated array of Hall effect sensors and support circuitry is surgically implanted in one bone, and a similarly encapsulated permanent magnet in an opposing bone, across a joint. The IJAT provides consistent, reliable, high quality signals that reflect joint movement from midsized two-degree-of-freedom joints. IJAT's were implanted using a chronic in vivo dog model to demonstrate the feasibility of implantation and periodic measurement techniques, and to validate modeling techniques used for prediction of function and calibration. The flexion resolution ranged from 0.4 to 3.0 degrees over a range of 115 degrees. The maximum deviation from a linear response was 9 degrees. The resolution and linearity depend on several transducer and joint geometry parameters, and can be predicted prior to implantation and calibrated after implantation. The results of this study 1) defined the most appropriate hermetic capsule designs for the IJAT sensor and magnet, 2) defined the best orientation of the magnetic field to optimize device function, 3) provided a computer model of the IJAT to aid in placement, calibration, and evaluation of the device, 4) verified the surgical techniques used to implant the device, and 5) verified the long-term functionality and the biocompatibility of the device.

Animals↗

A comparison between control methods for implanted FES hand-grasp systems.

Implanted neuroprostheses employing functional electrical stimulation (FES) provide grasp and release to individuals with tetraplegia. This paper describes and compares three methods of controlling the stimulated hand movement: shoulder position, wrist position and myoelectric activity from the wrist extensors. Three experienced neuroprosthesis users were evaluated with each of the control methods by performing a grasp release test (GRT). A significant improvement was found between each functional electrical stimulation (FES) method and tenodesis without FES. No significant difference in overall performance was found between the three FES methods of control. Each method of control demonstrated advantages and disadvantages which depend upon characteristics of the individual patient. Factors which must be considered are injury level, voluntary wrist strength, proximal upper limb strength, the level of cognition of the patient, hand-grasp characteristics, cosmeses, importance of using both arms, and personal preference. Due to the unique characteristics of each controller type, it is advantageous to have each type available for the FES patients to adapt the system to the needs and desires of the individual patient.

Electric Stimulation Therapy↗

A transducer for the measurement of finger joint moments.

A device capable of simultaneously measuring the isometric moments generated about the metacarpophalangeal (MP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints of all four fingers has been developed. The design utilizes a four-bar linkage to transmit moments, but not forces, to the device. This linkage allows the same device to fit a wide range of hand sizes without recalibration. The device was constructed out of aluminum bars which are strapped to each joint segment and to the back of the hand. Strain gauges mounted to the aluminum bars measure the bending moment on the device, which is directly related to the moment applied about the joint center of rotation. Because of the unique design of the device, it is not necessary to have accurate measurements of the joint center of rotation in order to get accurate moment information. A single device is capable of generating independent measurement of MP extension/flexion, PIP extension/flexion, and DIP extension/flexion. Four of these devices can be used to make simultaneous measurements of all the moments generated by all four fingers. The device also acts as a splint, allowing each joint to be positioned and locked at any angle through the range of motion of the joint. The device is accurate to within +/- 5.6% of each reading for moments from 10 N x cm to 100 N x cm and within +/- 2.0 N x cm for moments of 10 N x cm or less. If the device configuration is constrained, the accuracy can be improved to +/- 0.8% of full scale (100 N x cm) and +/- 0.21 N x cm for moments of 10 N x cm or less. The device can measure both flexion and extension moments up to 100 N x cm, and can allow the joints to be fixed at any angle from approximately 10 to 80 degrees.

Biophysical Phenomena↗

Educational disabilities of neonatal intensive care graduates.

OBJECTIVE: To determine the relationship between perinatal and sociodemographic factors in low birth weight and sick infants hospitalized at regional neonatal intensive care units (NICUs) and subsequent educational disabilities. METHOD: NICU graduates born between 1980 and 1987 at nine statewide regionalized level III centers were located in Florida elementary schools (kindergarten through third grade) during academic year 1992-1993 (n = 9943). Educational disability was operationalized as placement into eight mutually exclusive types of special education (SE) classifications determined by statewide standardized eligibility criteria: physically impaired, sensory impaired (SI), profoundly mentally handicapped, trainable mentally handicapped, educable mentally handicapped, specific learning disabilities, emotionally handicapped, and speech and language impaired (SLI). Logistic regression was used to estimate the odds of placement in SE for selected perinatal and sociodemographic variables. RESULTS: Placement into SE ranged from .8% for SI to 9.9% for SLI. Placement was related to four perinatal factors (birth weight, transport, medical conditions [congenital anomalies, seizures or intraventricular hemorrhage] and ventilation), and five sociodemographic factors (child's sex, mother's marital status, mother's race, mother's educational level, and family income). Perinatal factors primarily were associated with placement in physically impaired, SI, profoundly mentally handicapped, and trainable mentally handicapped. Perinatal and sociodemographic factors both were associated with placement in educable mentally handicapped and specific learning disabilities whereas sociodemographic factors primarily were associated with placement in emotionally handicapped and SLI. CONCLUSIONS: Educational disabilities of NICU graduates are influenced differently by perinatal and sociodemographic variables. Researchers must take into account both sets of these variables to ascertain the long-term risk of educational disability for NICU graduates. Birth weight alone should not be used to assess NICU morbidity outcomes.

Birth Weight↗

The monitoring of tendon tension with an implantable intratendon probe and its use in the control of neuroprostheses.

The use of a probe measuring tendon tension for the purpose of controlling a neuroprosthesis suited to spinal cord injured persons is investigated. The implanted probe detected inwardly directed radial force exerted by the tendon as the result of longitudinal tension. Varying types of load were applied to the tendon in order to measure static and dynamic parameters of the probe within the tendon. The results are discussed with respect to the potential use of the probe, within an active muscle's tendon, as a hand grasp neuroprosthesis controller. In addition, use of the probe to monitor electrically stimulated paralyzed muscle for the augmentation of closed loop control schemes is discussed.

Achilles Tendon↗

An implanted upper-extremity neuroprosthesis. Follow-up of five patients.

An implanted neuroprosthesis supplying functional neuromuscular stimulation was used to provide grasp and release to tetraplegic individuals. This article describes the results, at a minimum of three years, for the first five patients to have operative implantation of an eight-channel stimulator-receiver. All of the patients had a clinically complete spinal cord injury with motor function remaining at the level of the fifth or sixth cervical nerve root. In addition to implantation of the stimulator system, each patient had augmentative operations on the hand to improve function. The procedures included tendon transfers, side-to-side tendon anastomoses, arthrodesis of the interphalangeal joint of the thumb, and rotational osteotomy of the radius. The neuroprosthesis provides two grasp patterns controlled by voluntary motion of the shoulder or wrist. Functional evaluations included measurement of pinch force, a grasp-release test, evaluation of the level of functional independence, and usage surveys. Pinch force ranged from eight to twenty-five newtons. All five patients demonstrated functional grasp patterns, had increased independence, and were able to use the neuroprosthesis at home on a regular basis. The implanted stimulator has proved to be safe and reliable, with seven years as the longest time in situ at the time of writing.

Activities of Daily Living↗

Tendon transfers and functional electrical stimulation for restoration of hand function in spinal cord injury.

Spinal cord injury at the C5 and C6 level results in loss of hand function. Electrical stimulation of paralyzed muscles is one approach that has demonstrated significant capacity for restoring grasp and release function. One potential limitation of this approach is that key muscles for stimulation may have lower motor neuron damage, rendering the muscles unexcitable. We have used surgical modification of the biomechanics of the hand to overcome this limitation. Tendon transfer of paralyzed but lower motor neuron intact muscles can compensate for potential function lost owing to muscles with lower motor neuron damage. Such procedures have been performed to provide finger extension, thumb extension, finger flexion, and wrist extension. Additional surgical procedures have been performed to enhance the function provided with electrical stimulation. These are side-to-side synchronization of the finger flexor and extensor tendons, the flexor digitorium superficialis Zancolli-lasso procedure, and thumb interphalangeal joint arthrodesis. These procedures have been performed in 11 patients with C5 and C6 level spinal injuries and functional electrical stimulation neuroprostheses. In these patients, 41 different functional electrical stimulation-related procedures were performed and 38 gave the desired result after surgery. One procedure resulted in no increase or decrease in function or muscle output, and two procedures resulted in a decrease in muscle force or joint range of motion. The issues that must be considered in performing functional electrical stimulation-related tendon transfers are discussed.

Electric Stimulation Therapy↗

Tri-state myoelectric control of bilateral upper extremity neuroprostheses for tetraplegic individuals.

For the purpose of bimanual control of tetraplegic hands that have useful movement restored by a neuroprosthetic device, the use of myoelectric signals from bilateral sternoclei-domastoid muscles is proposed. Three state control has been proposed where each sternocleidomastoid controls its ipsilateral hand. Demonstration was made with spinal-cord-injured and nonspinal-cord-injured subjects providing three levels of activation that can be repeatably made with each of these muscles. The agonist and antagonist sternocleidomastoids during this command control were differentiated so that the desired hand will respond to a command. Neither normal head movements nor head position within its comfortable range of motion were shown to interfere with the proposed command. The provision of feedback was shown as important to provide robustness in the operation for the users selection of the right or left hand. The performance of spinal cord injured and noninjured persons using this controller was quantitatively measured through the completion of precision tracking tasks by the manipulation of on-screen virtual hands. All subjects were able to operate the controller with a degree of skill acceptable for completion of functional tasks with bilateral stimulated hand grasps. The sensitivity of the subjects performance to variation in controller parameters was also measured.

Arm↗