PubMed HealthSearch

Biomedical subjects

K L Wedding

Publications and source records attributed to K L Wedding.

2 recordsLinked to original sources

Coronary flow and flow reserve in canines using MR phase difference and complex difference processing.

Coronary artery disease continues to be the leading cause of death for adults in the United States. Magnetic resonance imaging (MR) has the potential to dramatically impact the diagnosis of heart disease by noninvasively providing a wide range of anatomic and physiologic information. Previous research has shown that coronary flow, one component of a complete examination, can be accurately measured in the left anterior descending artery in vivo. The current work validates MR flow measurements in canine circumflex arteries using transit time ultrasound as a standard. The circumflex artery experiences greater in-plane motion and is a more stringent test for flow measurement accuracy. This work also compares two methods of processing MR velocity data, phase difference and complex difference techniques, and examines the sources of error present in the animal validation model. Phase difference processing with a 30% magnitude threshold best matched the mean ultrasound flow values (30% PD = 1.04 x US + 1.49, r = 0.94), but it was very sensitive to vessel boundary identification. The complex difference process was less sensitive to vessel boundary identification and correlated well with the transit time ultrasound despite systematic underestimations. The reasons for the discrepancies are shown to stem from a number of possible sources including variability of the ultrasound standard, low signal-to-noise ratios in the MR images, sensitivity of the MR technique to vessel boundary identification, and motion artifacts in the images.

Animals

Effects of through-plane myocardial motion on phase-difference and complex-difference measurements of absolute coronary artery flow.

We have previously reported on a complex-difference (CD) flow measurement technique that produces more accurate results than the phase-difference (PD) flow measurement technique due to the greater immunity of the former method to partial volume effects. We report here on some of the ways in which through-plane myocardial motion affects the accuracy of absolute coronary artery flow measurements obtained using the PD and CD techniques. We also discuss motion correction schemes that can be applied to the PD and CD processing methods to improve their accuracy. Computer simulations have been performed to assess the magnitude of the errors associated with these flow measurement techniques when they are applied to small vessels that are attached to a moving background. Laminar and plug flow, with and without complete background suppression, have been considered. Experiments with a moving vessel phantom have been conducted to test the performance of the PD and CD flow measurement techniques in circumstances similar to those simulated. The simulations and the experiments showed that, after corrections for through-plane motion are made, the CD method generally yields more accurate flow results than the PD method. As shown by the simulations, however, both methods yield compromised results due to subtle saturation effects that occur when the direction of myocardial motion is opposite the direction of blood flow. Unvalidated PD and CD measurements of coronary artery flow waveforms in human volunteers are presented to illustrate the magnitude of the proposed through-plane motion effects in vivo.

Blood Flow Velocity