A comparative evaluation of two head and neck immobilization devices using electronic portal imaging.

A study was performed to compare the positioning reproducibility and the cost efficiency for two head and neck immobilization devices: the Uvex (Uvex Safety, Smithfield, USA) plastic mask system and the Finesse Frame with Ultraplast System (PLANET Medical, Svendborg, Denmark). 20 patients treated with 3D conformal radiation therapy for head and neck cancers were randomly selected (10 for each of the two different immobilization systems) and electronic portal images acquired during their course of treatment were saved and used in this study. The anatomical landmark coordinates and their shifts in the anteroposterior (AP) and craniocaudal (CC) directions with respect to the digitized simulator films for lateral fields were analysed using an in-house developed portal image registration system. Statistically, no evidence was found to indicate that the systematic components of the displacement for the Uvex system and the Finesse Frame with Ultraplast System were different from each other or from zero. The random component of displacement was slightly smaller in the AP direction for the Uvex than the Ultraplast system (sigma = 1.9 mm and 2.9 mm, respectively, p = 0.007), but larger in the CC direction (sigma = 3.8 mm and 2.2 mm, respectively, p<10(-9)). Production time and required materials for a radiation therapy department were also quantified to assess costs for each system. The overall costs per patient were estimated at 141.50 dollars (CAD) and 82.10 dollars for the Uvex and Ultraplast systems, respectively. The Finesse Frame with Ultraplast System of immobilization for head and neck cancer treatment provides a field placement reproducibility that is equal to, or greater than, that of the Uvex plastic mask immobilization system and, while it requires more expensive materials, the workload and consequently overall cost is greatly reduced.

Aged↗

The characterization of a promising new optical source for use with a radiotherapy treatment simulator.

We report on an experimental examination of a new powerful optical source with potential application in radiotherapy treatment simulation. The illuminance, effective source position, and source size have been measured for this new source and, for comparison, for conventional sources on a simulator and a linear accelerator. This new source is considerably brighter than those in common use in radiotherapy. Its effective optical source size is larger than that on the linear accelerator tested but comparable with that on a conventional simulator.

Phantoms, Imaging↗

Computer-assisted decision making in portal verification--optimization of the neural network approach.

PURPOSE: Conventional portal verification requires that a qualified radiation oncologist make decisions as to the set-up acceptability. This scheme is no longer sustainable with the large numbers of images available on-line and stringent time constraints. Therefore the objective of this study was to develop, optimize, and evaluate on clinical data an artificial intelligence decision-making tool for portal verification. The tool, based on the artificial neural network (ANN) approach, should approximate, as closely as possible, portal verification assessments made by a radiation oncologist expert. METHODS AND MATERIALS: A total of 328 electronic portal images of tangential breast irradiations were included in the study. A radiation oncologist expert evaluated these images and rated the treatment set-up acceptability on a scale from 0 to 10. Translational and rotational errors in the placement of the radiation field boundaries formed seven-dimensional feature vectors that represented each of the 328 portal images/treatments. The feature vectors were used as inputs to a three-layer, feedforward ANN. The neural network was trained on the oncologist's ratings. RESULTS: The rms discrepancy between the ANN and the expert's ratings was 1.05 rating points. Using the decision threshold equal to 5 for both sets of ratings, the ANN classifier was capable of detecting 100% of the portals classified as "unacceptable" by the expert. Only 6.5% of portals acceptable to the oncologist were misclassified as "unacceptable" by the ANN. CONCLUSION: The results of this study indicate the feasibility of using the ANN portal image classifier as an automated assistant to the radiation oncologist. Its role would be to recommend an appropriate decision as to the acceptability or otherwise of a given treatment set-up depicted in a portal image.

Breast Neoplasms↗

Application of a fuzzy pattern classifier to decision making in portal verification of radiotherapy.

With the large volume of electronic portal images acquired and stringent time constraints, it is no longer feasible to follow the convention whereby the radiation oncologist reviews and approves or rejects all portals. For that purpose we have developed a portal image classifier based on the fuzzy k-nearest neighbour (k-NN) algorithm. Each portal image is represented by a feature vector that consists of translational and rotational errors in the placement of radiation field borders that were measured in the portal image. Memberships in the acceptable portal class for the reference portal images within a training dataset were defined by a radiation oncologist expert. The fuzzy k-NN portal image classifier was trained and tested on a dataset of 328 portal images acquired during tangential irradiations of the breast. The memberships in the acceptable portal class produced by the fuzzy k-NN algorithm agreed very well with those defined by the expert. The linear correlation coefficient was equal to 0.89. Performance of the fuzzy k-NN classifier was also evaluated from the portal decision-making point of view using the measures of accuracy, sensitivity and specificity. The fuzzy k-NN portal classifier was capable of identifying almost all the truly unacceptable portals with an acceptably low false alarm rate.

Artificial Intelligence↗

A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device.

We describe the design and evaluation of a simple test tool which can be used in conjunction with either film or an electronic portal imaging device (EPID) to verify light and radiation fields and their congruence. The precision of the technique is better than 0.5 mm under all conditions tested. When used with film the accuracy or offset of the technique (the difference between test tool observations and a scanned conventional film) is better than 0.5 mm but, with an EPID as the image receptor, the accuracy dropped to, in one trial, 0.86 mm. The offset may be due to a systematic observer bias in determining the 50% O.D. level on the image, compounded, in the case of EPID measurements, by image acquisition and display parameters. Thus, when used with an EPID, calibration of the system will be required if absolute field dimensions are required. When used with film, the test tool method described here is of sufficient accuracy and precision to confirm the compliance of light and radiation field parameters with currently accepted quality control protocols.

Absorptiometry, Photon↗

On the controversies surrounding the origins of radiation therapy.

In this study the authors analyze the documentation regarding the earliest known X-ray treatments with the objective of identifying the true origin of radiation therapy. The four most often quoted events, including X-ray treatments allegedly performed in 1896 are analyzed in the light of available published reports. From this it is concluded that Despeignes of Lyon, who in July of 1896 irradiated a patient with cancer of the stomach, is in all likelihood the first person to perform documented radiation therapy treatments with a scientific and logical basis.

History, 19th Century↗

The Siemens virtual wedge.

A Siemens Virtual Wedge has recently been installed and commissioned at the Northeastern Ontario Regional Cancer Centre. Measurements reported below show that 1) Virtual Wedge factors are within 1.5% of 1; 2) percentage depth doses down to 15 cm for open and virtually wedged fields are identical to within 0.7%; 3) relative cross beam profiles for 60 degrees virtual and physical wedges are very similar except at the toe end where a 5% difference in relative dose has been observed and 4) the peripheral dose from the 60 degrees Virtual Wedge is about half of that from the 60 degrees physical wedge. A clinical protocol requiring combined open and 60 degrees wedged fields has been developed and validated. This protocol, which does not impair the utility of the Virtual Wedge, facilitates the use of on-line portal imaging and significantly reduces the effort required to commission the system.

Humans↗

Urocanic acid concentration and photoisomerization in Caucasian skin phototypes.

To investigate the relationship between erythemal sensitivity of the skin to UV radiation and epidermal urocanic acid (UCA) concentration, 45 healthy volunteers of anamnestic skin phototypes (ASP) 1-IV were studied. In 16 of the subjects, we analyzed UCA photoisomerization after graded UVB exposures. The median and mean total UCA concentration in unirradiated skin was 22.4 and 35.3 nmol/cm2, and no statistically significant difference in total UCA concentrations was detectable either between ASP I through II and III through IV or between the phototested skin type (PSP) groups 1 through 2 and 3 through 4. The relative amount of the cis-isomer varied between 3 and 35%, with median and mean values of 7 and 12%, respectively. No statistically significant difference in absolute or relative cis-UCA concentrations was detectable between ASP I through II and III through IV, but a significantly lower absolute (P < 0.009) and relative (P < 0.002) cis-UCA concentration in unirradiated skin was recorded in PSP groups 1 through 2, compared to types 3 through 4. In all tested subjects, an erythemally weighted dose of 1 mJ/cm2 sufficed to cause trans- to cis-UCA isomerization. When comparing photosensitive (skin phototype I) and phototolerant (phototypes III and IV) individuals, who were irradiated with a reference 5 mJ/cm2 UV dose or with fractions of 0.1-1.0 of their individual minimal erythema dose values, no skin phototype-dependent difference in ability to photoisomerize was discernible.

Adult↗

Quantitative vs. subjective portal verification using digital portal images.

PURPOSE: Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. METHODS AND MATERIALS: Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamfer matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. RESULTS: All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 degrees. For all four oncologists, the portals classified as unacceptable, in terms of the field placement, exhibited significantly higher (p < 0.03) translational errors in the transverse direction. The field coverages were significantly lower (p < 0.05) and the translational errors in the cranio-caudal direction were significantly higher (p < 0.05) for the portals rated as unacceptable by two of the oncologists. CONCLUSIONS: From the parameters that were used to quantify the degree of conformity between the prescription and treatment fields, the translational error in the transverse direction correlated best with the oncologists' assessments on the field placement. Field coverage and translational error in the cranio-caudal direction correlated well with assessments of only two out of the four participating oncologists. This can be explained by the fact that for the majority of treatment sites included in the study the positioning of field borders was more critical for the transverse direction. A conclusion for the design of future quantitative and automated on-line portal verification systems is that they will have to model different perceived significances of different types of localization errors intrinsic to oncologist evaluation of portal images.

Algorithms↗

The effects of the broadband UVA radiation on myeloid leukemia cells: the possible role of protein kinase C in mediation of UVA-induced effects.

We examined the effects of broadband UVA radiation (320-400 nm) on a rat myeloid leukemia cell line-chloroma (ChL). A Phillips face tanner model HB 171/A was used as a light source. Chloroma were irradiated through a 5 mm thick glass filter that cut off all of the UVB contamination. The irradiances were measured, from 250 to 400 nm, with a well-characterized and calibrated double-grating spectroradiometer Optronic 742. The overall uncertainty of dose evaluation was estimated to be +/-15% (2 sigma). The cells were irradiated with UVA doses of 4 and 8 J/cm2 and cultured thereafter for 24 h. After this period of time, a marked decline up to 50% was observed in cell proliferation in UVA-irradiated ChL cultures. The cell proliferation decline was found to be caused by simultaneously occurring G2/M phase cell cycle arrest and apoptosis in part of the UVA-irradiated ChL population. Concomitantly, with the decline in cell proliferation, an increase was observed in the expression of the major histocompatibility (MHC) class I and II antigens. Because protein kinase C (PKC) is known to regulate cell proliferation, apoptosis and expression of MHC antigens, and because UVA was shown to regulate PKC activity/expression, we therefore examined whether UVA irradiation has any effect on the expression of isozymes of PKC. Western blots revealed that ChL express alpha, beta I, delta, epsilon, eta, and zeta/iota isozymes of PKC and that expression of all isozymes declined 24 h after UVA irradiation (8 J/cm2). Finally, PKC activation in ChL by exposure to phorbol ester caused cell cycle arrest in G1 phase but did not induce apoptosis. This suggests that the previously shown UVA-induced PKC activation in ChL might be responsible for the induction of MHC antigens but the simultaneously observed ChL apoptosis is likely to be mediated by PKC down-regulation. All together, our results suggest that UVA, at irradiance levels that resemble the outdoor exposure, may have profound effects on the immune-related properties of leukocytes. Thus, we speculate that in vivo the immune functions of leukocytes passing through dermal capillaries might be altered by exposure to solar UVA radiation.

Animals↗

A polygon matching algorithm and its applications to verification of radiation field placement in radiotherapy.

An automated method for quantitative evaluation of geometric accuracy of radiation field placement during radiation therapy treatments has been developed and is presented in this article. The method is based on matching polygons representing the boundaries of the prescribed and treated radiation fields. An efficient algorithm for finding the intersection of two arbitrary simple polygons has been developed for that purpose. The process of polygon matching is performed by iterative optimization of the goodness-of-match measure derived from the area of the intersection between the two polygons to be matched. The optimization is done with respect to the translation and rotation in the plane that are applied to the polygon representing the treated field. The optimum translation and rotation define the adjustments in the position of the treated field, relative to the patients anatomy, which are necessary in order to bring the treated field into the best possible agreement with the prescription. The radiation field matching scheme was applied to a clinical dataset consisting of prescription-treatment field pairs extracted from simulation and portal images for 40 patients. It is concluded that the observed accuracy and efficiency of the method make it very suitable for applications in radiation therapy verification.

Algorithms↗

Segmented chamfer matching for the registration of field borders in radiotherapy images.

Optimum conformity between treated and prescribed radiotherapy fields is likely to be achieved when the full versatility of modern therapy equipment is reflected in the field registration method. To allow for independent jaws and custom shielding, chamfer matching has been used to register selected segments of field borders independently. In a study involving 50 clinical prescription-treatment field pairs it is shown that segmented chamfer matching is superior not only to conventional unsegmented chamfer matching but also to several other methods. An example of the clinical value of segmented chamfer matching applied to electronic portal images is given.

Algorithms↗

Long-wave ultraviolet radiation causes increase of membrane-bound fraction of protein kinase C in rat myeloid leukemia cells.

We examined the effect of long-wave ultraviolet radiation (UVA) on protein kinase C (PKC) and on the proliferation of rat myeloid leukemia cell line (ChL). Exposure of cells to a single dose of UVA (8 J/cm2 at 372 +/- 10 nm) caused a rapid increase in the quantity of the membrane-bound PKC, as assessed by 3H-phorbol ester (3H-PMA) binding assay (performed at 4 degrees C). Within 2 h of UVA irradiation, three peaks of increased 3H-PMA binding to the ChL cells (by 70-100%) were observed at ca. 20, 60 and 95 min post-irradiation. The exposure of ChL to UVA caused also a rapid, but transient, decline in the cell proliferation rate (by 18% within 24 h). However, the statistically significant decrease in cell numbers was observed only 3 days later (down by 22%). The inhibition of ChL proliferation was not due to alteration of cell viability as determined by trypan blue exclusion assay, and neither was it caused by cell cycle arrest or apoptosis, as determined by flow cytometry analysis of propidium iodide-labelled cells and cell morphology in May-Grünvald-Giemsa-stained cell smears. Phorbol-ester-induced activation of PKC (performed at 37 degrees C) caused inhibition of ChL proliferation similar to that caused by UVA. This suggests that a UVA-induced increase of the membrane-bound fraction of PKC may be responsible for the UVA-induced inhibition of ChL proliferation.

Animals↗

Increased UV exposure in Finland in 1993.

Exceptionally low total ozone, up to 40% below the normal level, was measured over Northern Europe during winter and spring in 1992 and 1993. In 1993 the depletion persisted up to the end of May, resulting in a significant increase of biologically effective UV radiation. The increases were significantly smaller in 1992 and 1993 than in 1993. The UV exposure of the Finnish population was evaluated through measurements and theoretical calculations. The increase in measured erythemal (International Lighting Commission) UV falling onto horizontal surfaces on clear day was determined relative to model calculations for an average ozone amount. The increase was on average 10% from April to May 1993, and the maximal measured increase was 34%. Theoretical calculations for both erythemal and carcinogenic (Skin Cancer Utrecht--Philadelphia) UV indicated that in 1993 the theoretical annual increase to a vertical (cylinder) surface ranged from 8 to 13% in Finland. The reflection of UV from snow considerably increases facial UV doses in Northern Finland.

Animals↗

Ultraviolet erythema sensitivity in anamnestic (I-IV) and phototested (1-4) Caucasian skin phototypes: the need for a new classification system.

The anamnestic skin phototypes (ASP) I-IV of 22 Caucasian volunteers wee compared with their phototested skin phototypes (PSP) using solar simulating, broadband UV radiation. The Commission Internationale de l'Eclairage (CIE)-weighted (i.e. erythemally effective) minimal erythema doses (MED) for solar simulating radiation varied from 20 mJ/cm2 (PSP type 1) to 57 mJ/cm2 (PSP type 4). In only 11 of 21 volunteers did the ASP (I-IV) and PSP (1-4) classifications coincide, and the MED values of the volunteers within the different ASP groups (I-IV) overlapped considerably. To compare the reactivity to erythematogenic radiation of different wavelengths, narrowband monochromator irradiations were performed at 298 nm, 310 nm and 330 nm. The CIE-weighted MED values at these wavelengths (20-80 mJ/cm2) corresponded well with those obtained in the broadband testing. Our results indicate that, with classification by interrogation, Caucasian skin can reliably be classified into only two subtypes, corresponding to Fitzpatrick phototypes I-III and phototype IV, respectively. A classification into four sensitivity types can be achieved by phototesting, only. We propose that the concept of ASP should be used with caution. The concept of PSP 1-4 should be favored.

Classification↗

Radiotherapy portal verification: an observer study.

In many radiotherapy facilities radiotherapy portal verification is currently a subjective process based on the visual comparison of a treatment or portal image with a prescription or simulation image. The reliability of this process is unknown. We describe here a study in which 16 observers (oncologists, physicists and therapists) independently evaluated the geometric accuracy of 530 treatment fields on 45 patients. The treatment images were acquired by the BEAMVIEW on-line portal imaging system (Siemens Medical Laboratories, Concord, CA, USA). Illustrative examples of the large variation in observers' assessments of the same field are given. The kappa statistic is used to evaluate the degree of agreement between observers and between on-line (at the treatment unit) and off-line (in a quiet viewing room) assessments. The best interobserver agreement was between the four oncologists contributing to the study although this level of agreement was rated only as "fair". Comparison of on-line and off-line decisions made by therapists exhibited "poor" agreement. This study has provided statistical confirmation of the suspicions of many workers in the field of radiotherapy portal verification, viz that the subjective evaluation of field accuracy is unreliable. However, the degree of unreliability is surprisingly large. The inconsistencies between observers documented in this study need to be clearly acknowledged in the development of protocols for the clinical use of on-line portal imaging systems. Acceptable reliability in radiotherapy portal verification will only be achieved when subjective decision making is eliminated.

Humans↗

Technical note: an aid to radiation therapy simulation.

We have mounted a transmission liquid crystal display unit on the head of a radiotherapy simulator and projected, using the field light, a digitized fluoroscopic image with treatment prescription overlay. It is suggested that this approach (i) can aid visualization on the patient of complex field borders including those defined by multileaf collimators; (ii) could play a role in computed tomography or magnetic resonance based treatment planning and (iii) contributes to configuring non-coplanar beams.

Computer Simulation↗

The investigation and rectification of field placement errors in the delivery of complex head and neck fields.

PURPOSE: To evaluate a novel technique for resolving field placement errors into their components and to quantify the improvement in accuracy potentially achievable by translation and rotation of the radiation beam. METHODS AND MATERIALS: One hundred and eighty-five films (both simulator and portal) from seventeen patients receiving radiotherapy to the head and neck region were analyzed in pairs. The computer based comparisons of complex fields with curved edges employed the intersections of perpendiculars from two reference points with the field periphery to define field match points. Field placement errors were resolved into those due to patient motion within the immobilization shell and those due to incorrect beam position, orientation, or shape. RESULTS: The median and the 95 percentile of the distribution of differences between prescribed (simulator) fields and treated (portal) fields referenced to the patients anatomy were 4.4 mm and 8.9 mm, respectively. The analysis suggests that with appropriate translation and rotation of the beam with respect to the immobilization shell these figures could be reduced to 3.1 mm and 8.2 mm, respectively, confirming the large contribution of patient motion within the shell to field placement accuracy. Comparisons between treated fields indicated smaller variability during treatment than between simulation and treatment. CONCLUSION: The perpendicular intersection method described here was found appropriate for the identification of field match points. The distributions of field placement errors were similar to those in a published study of straight edged fields. Translation and rotation of the applied field with respect to the immobilization shell would generally result in only a small improvement in field placement accuracy.

Head and Neck Neoplasms↗