[Enzymes in human bile. II. Enzyme content of liver- and gallbladder bile].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to K Lorentz.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present the adaptation of an IFCC method for alpha-amylase using 2-chloro-4-nitro-phenyl-alpha-D-maltotrio-side as substrate (1) suited for routine work at 37 degrees C. In the assay, a constant proportion of substrate, i. e. 92%, is directly converted to 2-chloro-4-nitrophenol and maltotriose. The method is based on multi- and univariate optimization leading to following measurement conditions: substrate, 2.25 mmol/l; chloride, 310 mmol/l; calcium 5.0 mmol/l; 4-morpholinoethanesulphonic acid, 50 mmol/l; pH 6.28. The assay may be carried out manually or by mechanized procedures, with substrate or sample start, and it shows these analytical properties in measuring amylase activity of sera: no lag phase, detection limit 2.9 U/l, linear range < or = 820 U/l (for 300 s) or < or = 1450 U/l (for 120 s of measurement), and total manual imprecision 3.2% (CV) at 46 U/l. Bilirubin < or = 630 micromol/l, haemoglobin < or =6 g/l, triacylglycerols < or =30 mmol/l, heparin < or =100 kU/l, and glucose < or =120 mmol/l do not interfere. For adults, we established a preliminary 0.95-reference interval of 30-90 U/l not dependent on sex or age. A close association with the IFCC method demonstrates the reliable transfer of its measurement conditions to a robust routine method with minimal changes.