Interference of ascorbic acid with chemical analytes.

BACKGROUND: Ascorbic acid can interfere with methodologies involving redox reactions, while comprehensive studies on main chemistry analysers have not been reported. We therefore attempted to determine the interference of ascorbic acid with analytes on the Beckman Synchron LX20. METHODS: Various concentrations of ascorbic acid were added to serum, and the serum analytes were measured on the LX20. RESULTS: With a serum ascorbic acid concentration of 12.0 mmol/L, the values for sodium, potassium, calcium and creatinine increased by 43%, 58%, 103% and 26%, respectively (P<0.01). With a serum ascorbic acid concentration of 12.0 mmol/L, the values for chloride, total bilirubin and uric acid decreased by 33%, 62% and 83%, respectively (P<0.01), and were undetectable for total cholesterol, triglyceride, ammonia and lactate. There was no definite influence of ascorbic acid on analytical values for total CO(2), urea, glucose, phosphate, total protein, albumin, amylase, creatine kinase, creatine kinase-MB, aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, total iron, unbound iron-binding capacity or magnesium. CONCLUSIONS: Ascorbic acid causes a false increase in sodium, potassium, calcium and creatinine results and a false decrease in chloride, total bilirubin, uric acid, total cholesterol, triglyceride, ammonia and lactate results.

Ascorbic Acid↗

Vitreous humor biochemical constituents: evaluation of between-eye differences.

The present study was conducted to investigate the differences in the vitreous humor biochemical concentrations for vitreous electrolytes and calcium in the same pair of eyes at identical postmortem interval (PMI). The vitreous humor samples were collected independently in both eyes from 48 autopsies (PMI range, 4.5-84.3 hours) with documented time of death. The samples were analyzed for potassium, sodium, chloride, and calcium using a Beckman Coulter LX20 Automated Analyzer based on ion-selective electrode methodology. There were no statistically significant between-eye differences at identical postmortem interval. A significantly high correlation was observed between paired potassium concentrations of both the eyes. A highly significant linear correlation was observed between the individual eye and mean potassium concentrations of both the eyes with postmortem interval. The observed differences were not significantly correlated with postmortem interval. The results demonstrated that the between-eye differences for vitreous electrolytes and calcium are insignificant. Therefore, the utility of vitreous biochemistry, particularly potassium in postmortem interval estimation and other forensic applications, cannot be questioned solely on the basis of these differences.

Calcium↗