The use of megavoltage CT (MVCT) images for dose recomputations.

Megavoltage CT (MVCT) images of patients are acquired daily on a helical tomotherapy unit (TomoTherapy, Inc., Madison, WI). While these images are used primarily for patient alignment, they can also be used to recalculate the treatment plan for the patient anatomy of the day. The use of MVCT images for dose computations requires a reliable CT number to electron density calibration curve. In this work, we tested the stability of the MVCT numbers by determining the variation of this calibration with spatial arrangement of the phantom, time and MVCT acquisition parameters. The two calibration curves that represent the largest variations were applied to six clinical MVCT images for recalculations to test for dosimetric uncertainties. Among the six cases tested, the largest difference in any of the dosimetric endpoints was 3.1% but more typically the dosimetric endpoints varied by less than 2%. Using an average CT to electron density calibration and a thorax phantom, a series of end-to-end tests were run. Using a rigid phantom, recalculated dose volume histograms (DVHs) were compared with plan DVHs. Using a deformed phantom, recalculated point dose variations were compared with measurements. The MVCT field of view is limited and the image space outside this field of view can be filled in with information from the planning kVCT. This merging technique was tested for a rigid phantom. Finally, the influence of the MVCT slice thickness on the dose recalculation was investigated. The dosimetric differences observed in all phantom tests were within the range of dosimetric uncertainties observed due to variations in the calibration curve. The use of MVCT images allows the assessment of daily dose distributions with an accuracy that is similar to that of the initial kVCT dose calculation.

Algorithms↗

Evaluation of a diode array for QA measurements on a helical tomotherapy unit.

A helical tomotherapy system is used in our clinic to deliver intensity-modulated radiation therapy (IMRT) treatments. Since this machine is designed to deliver IMRT treatments, the traditional field flatness requirements are no longer applicable. This allows the unit to operate without a field flatness filter and consequently the 400 mm wide fan beam is highly inhomogeneous in intensity. The shape of this beam profile is mapped during machine commissioning and for quality assurance purposes the shape of the beam profile needs to be monitored. The use of a commercial diode array for quality assurance measurements is investigated. Central axis beam profiles were acquired at different depths using solid water built-up material. These profiles were compared with ion chamber scans taken in a water tank to test the accuracy of the diode array measurements. The sensitivity of the diode array to variations in the beam profile was checked. Over a seven week period, beam profiles were repeatedly measured. The observed variations are compared with those observed with an on-board beam profile monitor. The diode measurements were in agreement with the ion chamber scans. In the high dose, low gradient region the average ratio between the diode and ion chamber readings was 1.000 +/- 0.005 (+/- 1 standard deviation). In the penumbra region the agreement was poorer but all diodes passed the distance to agreement (DTA) requirement of 2 mm. The trend in the beam profile variations that was measured with the diode array device was in agreement with the on-board monitor. While the calculated amount of variation differs between the devices, both were sensitive to subtle variations in the beam profile. The diode array is a valuable tool to quickly and accurately monitor the beam profile on a helical tomotherapy unit.

Evaluation Studies as Topic↗

Prostate movement during simulation resulting from retrograde urethrogram compared with "natural" prostate movement.

PURPOSE: Retrograde urethrography (UG) is commonly used at the time of simulation to assist in defining the prostate apex. Some investigators have reported that performing the UG introduces error by causing prostate displacement. We investigate the movement of the prostate caused by the retrograde UG. METHODS AND MATERIALS: Twenty-four patients treated with three-dimensional conformal radiotherapy for prostate cancer who had gold marker seeds placed into their prostates were studied. Marker seed locations at the time of simulation and on the portal images acquired just before the treatment were compared with the locations on digitally reconstructed radiographs (DRR). Movement in the superior-inferior and anteroposterior directions as seen on lateral images was measured from 402 portal images by offline customized imaging software and evaluated using analysis of variance methods for continuous variables and chi-square statistics for categoric variables. RESULTS: "Natural" nonrandom movement of the prostate around an "origin" as defined by markers on DRR was observed. This movement tends to be in a superior and anterior direction, with the average shift being 1 mm and 0.82 mm, respectively. The magnitude of movement in the superior direction averaged 2.88 mm compared with 1.64 mm in the inferior direction (p = 0.04). There was slightly greater movement after the UG compared with mean "natural" movement but the difference was less than 3 mm in either direction on average (difference: superior-inferior = 2.64 mm, p = 0.004; anteroposterior = 2.24, p = 0.035). CONCLUSIONS: Use of the UG induces a small but clinically insignificant displacement of the prostate when "natural" movement is taken into account.

Humans↗

Evaluation of ultrasound-based prostate localization for image-guided radiotherapy.

To evaluate the use of the ultrasound-based BAT system for daily prostate alignment. Prostate alignments using the BAT system were compared with alignments using radiographic images of implanted radiopaque markers. The latter alignments were used as a reference. The difference between the BAT and marker alignments represents the displacements that would remain if the alignments were done using ultrasonography. The inter-user variability of the contour alignment process was assessed. On the basis of the marker alignments, the initial displacement of the prostate in the AP, superoinferior, and lateral direction was -0.9 +/- 3.9, 0.1 +/- 3.9, and 0.2 +/- 3.4 mm respectively. The directed differences between the BAT and marker alignments in the respective directions were 0.2 +/- 3.7, 2.7 +/- 3.9, and 1.6 +/- 3.1 mm. The occurrence of displacements >/=5 mm was reduced by a factor of two in the AP direction after the BAT system was used. Among eight users, the average range of couch shifts due to contour alignment variability was 7, 7, and 5 mm in the antero-posterior (AP), superoinferior, and lateral direction, respectively. In our study, the BAT alignments were systematically different from the marker alignments in the superoinferior, and lateral directions. The remaining random variability of the prostate position after the ultrasound-based alignment was similar to the initial variability. However, the occurrence of displacements >/=5 mm was reduced in the AP direction. The inter-user variation of the contour alignment process was significant.

Humans↗

Measurement of the tissue to A-150 tissue equivalent plastic kerma ratio at two p(66)Be neutron therapy facilities.

The ICRU tissue to A-150 tissue equivalent plastic kerma ratio is needed for neutron therapy dosimetry. The current ICRU protocol for neutron dosimetry recommends using a common conversion factor of 0.95 at all high-energy neutron therapy facilities. In an effort to determine facility specific ICRU tissue to A-150 plastic kerma ratios, an experimental approach was pursued. Four low pressure proportional counters that differed in wall materials (i.e. A-150, carbon, zirconium and zirconium-oxide) were used as dosimeters and integral kerma ratios were determined directly in the clinical beam. Measurements were performed at two p(66)Be facilities: iThemba LABS near Cape Town and Fermilab near Chicago. At the iThemba facility the clinical neutron beam is routinely filtered by a flattening and hardening filter combination. The influence of beam filtration on the kerma ratio was evaluated. Using two recent gas-to-wall dose conversion factor (r(m,g) value) evaluations a mean ICRU tissue to A-150 plastic kerma ratio of 0.93 +/- 0.05 was determined for the clinical beam at iThemba LABS. The respective value for the Fermilab beam is 0.95 +/- 0.05. The experimentally determined ICRU tissue to A-150 plastic kerma ratios for the two clinical beams are in agreement with theoretical evaluations. Beam filtration reduces the kerma ratio by 3 +/- 2%.

Biophysical Phenomena↗

Organ motion and its management.

PURPOSE: To compile and review data on the topic of organ motion and its management. METHODS AND MATERIALS: Data were classified into three categories: (a) patient position-related organ motion, (b) interfraction organ motion, and (c) intrafraction organ motion. Data on interfraction motion of gynecological tumors, the prostate, bladder, and rectum are reviewed. Literature pertaining to the intrafraction movement of the liver, diaphragm, kidneys, pancreas, lung tumors, and prostate is compiled. Methods for managing interfraction and intrafraction organ motion in radiation therapy are also reviewed.

Female↗