PubMed HealthSearch

Biomedical subjects

K M Millan

Publications and source records attributed to K M Millan.

2 recordsLinked to original sources

Voltammetric DNA biosensor for cystic fibrosis based on a modified carbon paste electrode.

Carbon paste electrodes modified by the inclusion of either octadecylamine or stearic acid were used as solid phases to which DNA was covalently bound. Immobilized DNA was detected by voltammetry of solutions containing submillimolar quantities of Co(bpy)3(ClO4)3, Co(phen)3(ClO4)3, and Os(bpy)3-Cl2 (bpy = 2,2'-bipyridine; phen = 1,10-phenanthroline), all of which associate reversibly with immobilized DNA and yield increased peak currents at DNA-modified electrodes. Immobilization onto octadecylamine-modified electrodes was performed using a water-soluble carbodiimide, and at high DNA concentrations in the reaction mixture, it resulted in visible polymerization of DNA on the surface. Optimization of the deoxyguanosine- (dG-) selective immobilization reaction for stearic acid-modified electrodes, using water-soluble carbodiimide and N-hydroxysulfosuccinimide reagents to activate carboxylate groups on the surface, yielded conditions of 4.5% (w/w) stearic acid and 10 micrograms/mL DNA. Polythymidylic acid of 4000-base average length (poly(dT)4000) was immobilized at stearic acid-modified electrodes following enzymatic elongation with dG residues at the 3'-end. These DNA-modified electrodes were used to study hybridization with analyte poly(dA)4000 by in situ voltammetry of 60 microM Co(bpy)3(ClO4)3 at low ionic strength (20 mM NaCl), and by voltammetry of the same complex, following exposure of the electrode to poly(dA)4000 in a separate hybridization step conducted at high ionic strength (0.5 M NaCl). Results indicate slow (> or = 1 h) hybridization at low ionic strength and fast (< or = 10 min) hybridization at high ionic strength.(ABSTRACT TRUNCATED AT 250 WORDS)

Base Sequence

Sequence-selective biosensor for DNA based on electroactive hybridization indicators.

Deoxyribonucleic acid was covalently immobilized onto oxidized glassy carbon electrode surfaces that had been activated using 1-[3-(dimethylamino)-propyl]-3-ethylcarbodimide hydrochloride and N-hydroxysulfosuccinimide. This reaction is selective for immobilization through deoxyguanosine (dG) residues. Immobilized DNA was detected voltammetrically, using tris (2,2'-bipyridyl)cobalt(III) perchlorate and tris (1,10-phenanthroline)cobalt(III) perchlorate (Co(bpy)3(3+) and Co(phen)3(3+). These complexes are reversibly electroactive (1e-) and preconcentrate at the electrode surface through association with double-stranded DNA. Voltammetric peak currents obtained with a poly(dG)poly(dC)-modified electrode depend on [Co(bpy)3(3+)] and [Co(phen)3(3+)] in a nonlinear fashion and indicate saturation binding with immobilized DNA. Voltammetric peak currents for Co(phen)3(3+) reduction were used to estimate the (constant) local DNA concentration at the modified electrode surface; a binding site size of 5 base pairs and an association constant of 1.74 x 10(3) M(-1) yield 8.6 +/- 0.2 mM base pairs. Cyclic voltammetric peak separations indicate that heterogeneous electron transfer is slower at DNA-modified electrodes than at unmodified glassy carbon electrodes. A prototype sequence-selective DNA sensor was constructed by immobilizing a 20-mer oligo (deoxythymidylic acid) (oligo(dT)20), following its enzymatic elongation with dG residues, which yielded the species oligo(dT)20(dG)98. Cyclic voltammograms of 0.12 mM Co(bpy)3(3+) obtained before and after hybridization with poly-(dA) and oligo(dA)20 show increased cathodic peaks after hybridization. The single-stranded form is regenerated on the electrode surface by rinsing with hot deionized water. These results demonstrate the use of electroactive hybridization indicators in a reusable sequence-selective biosensor for DNA.

Animals