PubMed Health⌕ Search

Biomedical subjects

K M Stein

Publications and source records attributed to K M Stein.

At least 19 recordsLinked to original sources

Nonlinear-dynamical arrhythmia control in humans.

Nonlinear-dynamical control techniques, also known as chaos control, have been used with great success to control a wide range of physical systems. Such techniques have been used to control the behavior of in vitro excitable biological tissue, suggesting their potential for clinical utility. However, the feasibility of using such techniques to control physiological processes has not been demonstrated in humans. Here we show that nonlinear-dynamical control can modulate human cardiac electrophysiological dynamics by rapidly stabilizing an unstable target rhythm. Specifically, in 52/54 control attempts in five patients, we successfully terminated pacing-induced period-2 atrioventricular-nodal conduction alternans by stabilizing the underlying unstable steady-state conduction. This proof-of-concept demonstration shows that nonlinear-dynamical control techniques are clinically feasible and provides a foundation for developing such techniques for more complex forms of clinical arrhythmia.

Adult↗

Significance of inducible ventricular fibrillation in patients with coronary artery disease and unexplained syncope.

OBJECTIVES: This study was designed to determine the incidence and prognostic significance of inducible ventricular fibrillation (VF) in patients with coronary artery disease (CAD) and unexplained syncope. BACKGROUND: Current American College of Cardiology/American Heart Association practice guidelines recommend implantation of internal cardioverter-defibrillators (ICDs) in patients with unexplained syncope in whom either ventricular tachycardia (VT) or VF is inducible during electrophysiologic (EP) testing. Although the prognostic significance of inducible monomorphic VT is known, the significance of inducible VF remains undefined. METHODS: We evaluated 118 consecutive patients with CAD and unexplained syncope who underwent EP testing. Sustained monomorphic VT was inducible in 53 (45%) patients; in 20 (17%) patients, VF was the only inducible arrhythmia; and no sustained ventricular arrhythmia was inducible in the remaining 45 (38%) patients. The latter two groups of 65 (55%) patients make up the study population. RESULTS: There were 16 deaths among the study population during a follow-up period of 25.3 +/- 19.6 months. The overall one- and two-year survival in these patients was 89% and 81%, respectively. No significant difference in survival was observed between patients with and without inducible VF (80% power to detect a fourfold survival difference). CONCLUSIONS: In 17% of patients with CAD and unexplained syncope, VF is the only inducible ventricular arrhythmia. Within the limits of this pilot study, long-term follow-up of patients with and without inducible VF demonstrates no difference in survival between the two groups. Therefore, the practice of ICD implantation in patients with CAD, unexplained syncope and inducible VF, especially with triple ventricular extrastimuli, may merit reconsideration.

Aged↗

Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator system.

INTRODUCTION: Management of atrial tachyarrhythmias represents a significant challenge in patients with implantable cardioverter defibrillators (ICDs). Drug therapy of these arrhythmias is limited by moderate efficacy, ventricular proarrhythmia, and drug-device interactions. This study tested the safety and efficacy of a new dual-chamber ICD to detect and treat atrial as well as ventricular tachyarrhythmias. METHODS AND RESULTS: A dual-chamber ICD (Medtronic 7250 Jewel AF) was implanted in 293 of 303 patients at 49 centers in Europe, Canada, and North America. Specific data were collected at implant and during a mean follow-up period of 7.9+/-4.7 months. There were no clinically evident failures to detect and treat ventricular arrhythmias. In patients with at least one of the dual-chamber detection criteria activated, 1,056 of 1,192 episodes of ventricular tachycardia or fibrillation detected were judged to be appropriate (89% positive predictive accuracy). Therapy efficacy was 100% in the ventricular fibrillation zone and 98% in the ventricular tachycardia zone. Positive predictive accuracy for detection of atrial episodes was 95% (1,052/1,107). For episodes classified as atrial tachycardia by the device, the efficacy of atrial antitachycardia pacing and high-frequency (50-Hz) burst pacing was 55% and 17%, respectively. High-frequency burst pacing terminated 16.8% of episodes classified as atrial fibrillation, and atrial defibrillation had an estimated efficacy of 76%. The actuarial estimates of 6-month complication-free survival and total survival were 88% and 94%, respectively. CONCLUSION: This novel dual-chamber ICD is capable of safely and effectively discriminating atrial from ventricular tachyarrhythmias and of treating atrial tachyarrhythmias without compromising detection and treatment of ventricular tachyarrhythmias.

Aged↗

Formal analysis of the optimal duration of tilt testing for the diagnosis of neurally mediated syncope.

BACKGROUND: Although tilt testing has emerged as the test of choice for assessing patients with suspected neurally mediated syncope, the optimum duration of tilt testing is poorly defined. This in part relates to the absence of a gold standard to assess test performance. OBJECTIVE: Our purpose was to formally estimate the effects of varying duration of drug-free tilt testing on test performance in diagnosing neurally mediated syncope. DESIGN: If a test's specificity is known, then in the absence of a gold standard an imputed (estimated) sensitivity may be calculated on the basis of the observed diagnostic yield in a given population as a function of assumed population prevalence. We determined the relationship of specificity to drug-free tilt test duration by use of data from 11 previous studies reporting the results of drug-free tilt testing in a total of 435 control subjects (60 to 80 degrees of tilt, footboard support, 15- to 60-minute duration). Data (weighted for study size) were fit to an exponential function relating specificity to tilt duration. Test yield was evaluated as a function of tilt duration in 213 consecutive patients referred to our laboratory for the evaluation of suspected neurally mediated syncope who underwent passive tilt testing for up to 30 to 60 minutes. RESULTS: The estimated specificity of tilt testing was 94% at 30 minutes, 92% at 40 minutes, and 88% after 60 minutes of passive tilt. The cumulative yield of tilt testing was only 17% at 30 minutes, 22% at 40 minutes, and 28% after 60 minutes. On the basis of an estimated population prevalence of 25% to 50% in this referral population, imputed sensitivity is 27% to 48% at 30 minutes, 36% to 64% at 40 minutes, and 43% to 74% after 60 minutes of passive tilt. The overall diagnostic accuracy was not strongly influenced by tilt duration beyond 30 minutes and ranged from 60% to 84%. CONCLUSIONS: Passive tilt testing (ie, tilt testing without pharmacologic provocation) for durations of up to 60 minutes has limited sensitivity for diagnosing neurally mediated syncope. For populations with a pretest likelihood of 25% to 50%, test results are inaccurate in one to two fifths of patients.

Data Interpretation, Statistical↗

Complex AV nodal dynamics during ventricular-triggered atrial pacing in humans.

In vitro experiments have shown that the complexity of atrioventricular nodal (AVN) conduction dynamics increases with heart rate. Although complex AVN dynamics (e.g., alternans) have been observed clinically, human AVN dynamics during rapid pacing have not been systematically investigated. We studied such dynamics during ventricular-triggered atrial pacing in 37 patients with normal AVN function (18 patients with dual AVN pathway physiology and 19 patients without). Alternans, which always resulted from single pathway conduction, occurred in 18 patients. In 16 patients (3 of whom also had alternans), quasisinusoidal AVN conduction oscillations occurred (mean frequency 0.02 Hz); such oscillations have not been previously reported. There were no significant differences in the dynamics for patients with or without dual AVN pathways. To illuminate the governing dynamic mechanism, a second atrial pacing trial was performed on 12 patients after autonomic blockade. Blockade facilitated alternans but inhibited oscillations. This study suggests that rapid AVN excitation in vivo can lead to autonomically mediated AVN conduction oscillations or single pathway alternans that are a function of inherent nonlinear dynamic AVN tissue properties.

Atrioventricular Node↗

Electrophysiologic effects of a novel selective adenosine A1 agonist (CVT-510) on atrioventricular nodal conduction in humans.

BACKGROUND: CVT-510, N-(3(R)-tetrahydrofuranyl)-6-aminopurine riboside, is a selective A(1)-adenosine receptor agonist with potential potent antiarrhythmic effects in tachycardias involving the atrioventricular (AV) node. This study, the first in humans, was designed to determine the effects of CVT-510 on AV nodal conduction and hemodynamics. METHODS AND RESULTS: Patients in sinus rhythm with normal AV nodal function at electrophysiologic study (n = 32) received a single intravenous bolus of CVT-510. AH and HV intervals were measured during sinus rhythm and during atrial pacing at 1, 5, 10, 15, 20, 30, 45, and 60 minutes after the bolus. Increasing doses of CVT-510 (0.3 to 10 microg/kg) caused a dose-dependent increase in the AH interval. At 1 minute, a dose of 10 microg/kg increased the AH interval during sinus rhythm from 93 +/- 23 msec to 114 +/- 37 msec, p = 0.01 and from 114 +/- 31 msec to 146 +/- 44 msec during atrial pacing at 600 msec, p = 0.003). The AH interval returned to baseline by 20 minutes. CVT-510 at doses of 0.3 to 10 microg/kg had no effect on sinus rate, HV interval, or systemic blood pressure, and was not associated with serious adverse effects. At doses of 15 and 30 microg/kg, CVT-510 produced transient second/third degree AV heart block in all four patients treated. One of these patients also had a prolonged sedative effect that was reversed with aminophylline. CONCLUSIONS: CVT-510 promptly prolongs AV nodal conduction and does not affect sinus rate or blood pressure. Selective stimulation of the A(1)-adenosine receptor by CVT-510 may be useful for immediate control of heart rate in atrial fibrillation/flutter and to convert paroxysmal supraventricular tachycardia to sinus rhythm, while avoiding vasodilatation mediated by the A(2)-adenosine receptor, as well as the vasodepressor and negative inotropic effects associated with beta-adrenergic receptor blockade and/or calcium channel blockers.

Adenosine↗

Transthoracic cardioversion of atrial fibrillation: comparison of rectilinear biphasic versus damped sine wave monophasic shocks.

BACKGROUND: Clinical studies have shown that biphasic shocks are more effective than monophasic shocks for ventricular defibrillation. The purpose of this study was to compare the efficacy of a rectilinear biphasic waveform with a standard damped sine wave monophasic waveform for the transthoracic cardioversion of atrial fibrillation. METHODS AND RESULTS: In this prospective, randomized, multicenter trial, patients undergoing transthoracic cardioversion of atrial fibrillation were randomized to receive either damped sine wave monophasic or rectilinear biphasic shocks. Patients randomized to the monophasic protocol (n=77) received sequential shocks of 100, 200, 300, and 360 J. Patients randomized to the biphasic protocol (n=88) received sequential shocks of 70, 120, 150, and 170 J. First-shock efficacy with the 70-J biphasic waveform (60 of 88 patients, 68%) was significantly greater than that with the 100-J monophasic waveform (16 of 77 patients, 21%, P<0.0001), and it was achieved with 50% less delivered current (11+/-1 versus 22+/-4 A, P<0.0001). Similarly, the cumulative efficacy with the biphasic waveform (83 of 88 patients, 94%) was significantly greater than that with the monophasic waveform (61 of 77 patients, 79%; P=0.005). The following 3 variables were independently associated with successful cardioversion: use of a biphasic waveform (relative risk, 4.2; 95% confidence intervals, 1.3 to 13.9; P=0.02), transthoracic impedance (relative risk, 0.64 per 10-Omega increase in impedance; 95% confidence intervals, 0.46 to 0.90; P=0.005), and duration of atrial fibrillation (relative risk, 0.97 per 30 days of atrial fibrillation; 95% confidence intervals, 0.96 to 0.99; P=0.02). CONCLUSIONS: For transthoracic cardioversion of atrial fibrillation, rectilinear biphasic shocks have greater efficacy (and require less energy) than damped sine wave monophasic shocks.

Aged↗

Left ventricular geometry and function preceding neurally mediated syncope.

BACKGROUND: Neurally mediated syncope has been associated with increased left ventricular (LV) fractional shortening (FS) during tilt testing, which is consistent with the hypothesis that the stimulation of LV mechanoreceptors leads to reflex hypotension and/or bradycardia. However, FS does not represent true LV contractility because of its dependence on afterload and preload. METHODS AND RESULTS: To elucidate the role of increased contractility in the mediation of neurally mediated syncope, we compared echocardiographic measures of LV performance corrected for end-systolic stress (ESS) in 21 patients (13 women and 8 men) with unexplained syncope who had either positive (n=10) or negative (n=11) responses to a tilt-table test. Two-dimensional echocardiographic LV imaging was performed at baseline and during the initial 5 minutes of upright tilt. In the supine position, both groups had similar LV end-diastolic volume indexes, stroke volumes, FS, circumferential ESS, and afterload-independent measures of LV performance (stress-corrected midwall and FS). However, after 5 minutes of upright tilt, patients who subsequently had a positive test had a lower stroke volume, lower stress-corrected midwall shortening, and endocardial FS. The tilt-positive group also had a greater fall in ESS and FS early during upright tilt. CONCLUSIONS: Reduced ESS, LV volume, and chamber function during initial upright tilt are associated with a subsequent positive tilt response in patients with unexplained syncope. These data suggest that if paradoxic activation of LV mechanoreceptors has a role in mediating neurally mediated syncope, it is not triggered by LV hypercontractility or increased systolic wall stress during the initial period of upright tilt.

Adolescent↗

[Blindness caused by an airbag in a minor accident].

PURPOSE: Installation of airbags has reduced the rate of fatal injuries in severe automobile accidents. We report, however, severe ocular injuries in a minor accident as the result of an airbag. CASE REPORT: A front passenger suffered a blunt ocular trauma of her right eye during a collision. The approaching speed was about 31 km/h. The maximum change of velocity in direction of the impact was 19 km/h. Color traces were found on the upper rim of the airbag, apparently from the patient's eye shadow. RESULTS: In the emergency room, visual acuity was reduced to light perception. There was endothelial contusion, traumatic mydriasis, and lens subluxation. A sclopetarian retinopathy developed with a chorioretinal scar. Eight months after the accident visual acuity remained at light projection only. CONCLUSIONS: The eye injuries had very probably been caused by the deploying airbag. Improvements are a better geometry of deployment (e.g., tethered airbags), release at higher impacts only, and "intelligent systems" with additional sensors to avoid potentially hazardous airbag inflation in minor accidents.

Accidents, Traffic↗

Detection of gunshot residues in routine CTs.

The forensic assessment of non-fatal gunshot wounds often proves to be difficult as wounds have usually been cleaned and protected with a sterile bandage by the time of the examination. The aim of our investigation was to test the possible application of computed tomography (CT) for the forensic assessment. Doing so raised the questions whether gunshot residues in the soft tissues, detected by means of 3-dimensional CT, can be used as evidence of a close-range shot and whether conclusions can be drawn pertaining to the range of the shot or the type of bullet used based on the distribution of the radiologically detectable material? In this experimental study 39 shots were fired at fresh pig skin and it was possible to distinguish shots fired from distances of more than 10 cm and contact shots independent of the type of bullet. For unjacketed lead bullets, radiopaque material could be seen in the depth of the entrance would for firing distances up to 10 cm. In individual cases, CT data and the 3-D reconstruction could provide valuable information in the forensic assessment of patients with gunshot wounds.

Animals↗

Ventricular arrhythmias in normal hearts.

Idiopathic ventricular tachycardia (VT) is characterized by two predominant forms. The most common form originates from the right ventricular outflow tract and presents as repetitive monomorphic VT or exercise-induced VT. The tachycardia is adenosine sensitive and is thought to be because of cAMP-mediated triggered activity. The other major form of idiopathic VT is owing to verapamil-sensitive intrafascicular re-entrant tachycardia, which most often originates in the region of the left posterior fascicle. Both forms of idiopathic VT can be readily treated with radiofrequency catheter ablation.

Catheter Ablation↗

Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation. ZOLL Investigators.

OBJECTIVES: We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND: Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential biphasic waveform was shown to have equivalent efficacy to a 200-J damped sine wave monophasic waveform for transthoracic ventricular defibrillation. However, the optimal type of biphasic waveform is unknown. METHODS: In this prospective, randomized, multicenter trial, 184 patients who underwent ventricular defibrillation were randomized to receive a 200-J damped sine wave monophasic or 120-J rectilinear biphasic shock. RESULTS: First-shock efficacy of the biphasic waveform was significantly greater than that of the monophasic waveform (99% vs. 93%, p = 0.05) and was achieved with nearly 60% less delivered current (14 +/- 1 vs. 33 +/- 7 A, p < 0.0001). Although the efficacy of the biphasic and monophasic waveforms was comparable in patients with an impedance < 70 ohms (100% [biphasic] vs. 95% [monophasic], p = NS), the biphasic waveform was significantly more effective in patients with an impedance > or = 70 ohms (99% [biphasic] vs. 86% [monophasic], p = 0.02). CONCLUSIONS: This study demonstrates a superior efficacy of rectilinear biphasic shocks as compared with monophasic shocks for transthoracic ventricular defibrillation, particularly in patients with a high transthoracic impedance. More important, biphasic shocks defibrillated with nearly 60% less current. The combination of increased efficacy and decreased current requirements suggests that biphasic shocks as compared with monophasic shocks are advantageous for transthoracic ventricular defibrillation.

Aged↗

Induction of neurally mediated syncope with adenosine.

BACKGROUND: Tilt testing is used to establish the diagnosis of neurally mediated syncope. However, applicability of the tilt test is limited by test sensitivity and length of time required to perform the test. We hypothesized that adenosine could facilitate the induction of neurally mediated syncope through its sympathomimetic effects and therefore could be used as an alternative to routine tilt testing. METHODS AND RESULTS: In protocol 1, the yield of adenosine tilt testing (12 mg while upright, followed by 60 degrees tilt for 5 minutes) and a 15-minute isoproterenol tilt test were compared in 84 patients with a negative 30-minute drug-free tilt test. In protocol 2, 100 patients underwent an initial adenosine tilt test followed by our routine tilt test (30-minute drug-free tilt followed by a 15-minute isoproterenol tilt). Six additional control patients underwent microneurography of the peroneal nerve to compare the sympathomimetic effects during bolus administration of adenosine and continuous infusion of isoproterenol. In protocol 1, the yields of adenosine (8 of 84, 10%) and isoproterenol (7 of 84, 8%) tilt testing were comparable (P=NS). In protocol 2, the yields of adenosine (19 of 100, 19%) and routine (22 of 100, 22%) tilt testing were also comparable (P=NS). Although the yield of adenosine tilt testing was comparable in both protocols, patients with a negative adenosine tilt test but a positive routine tilt test usually required isoproterenol to elicit the positive response. Microneurography confirmed discordant sympathetic activation after adenosine and isoproterenol administration. CONCLUSIONS: Adenosine is effective for the induction of neurally mediated syncope, with a diagnostic yield comparable to routine tilt testing. However, the discordant results obtained with adenosine and the isoproterenol phase of routine tilt testing suggest that adenosine and isoproterenol tilt testing may have complementary roles in eliciting a positive response. Therefore, a tilt protocol that uses an initial adenosine tilt followed, if necessary, by an isoproterenol tilt would be expected to increase the overall yield and reduce the duration of tilt testing.

Adenosine↗

Long-term outcome of patients with unexplained syncope treated with an electrophysiologic-guided approach in the implantable cardioverter-defibrillator era.

OBJECTIVES: We evaluated the long-term outcome of patients with coronary artery disease and unexplained syncope who were treated with an electrophysiologic (EP)-guided approach. BACKGROUND: Electrophysiologic studies are frequently performed to evaluate unexplained syncope in patients with coronary artery disease. Patients with this profile who have inducible ventricular tachycardia are considered at high risk for sudden death and increased overall mortality, and therefore are often treated with an implantable cardioverter-defibrillator (ICD). The impact of this EP-guided strategy is unknown because there are no data comparing the long-term outcome of ICD recipients with that of noninducible patients. METHODS: We evaluated 67 consecutive patients with coronary artery disease and unexplained syncope. All patients were treated with an EP-guided approach that included ICD implantation in patients with inducible ventricular tachycardia. RESULTS: Electrophysiologic testing suggested a plausible diagnosis in 32 (48%) of these patients. Inducible monomorphic ventricular tachycardia was the most common abnormality. Despite frequent appropriate therapy with ICDs, the total mortality for patients with inducible monomorphic ventricular tachycardia was significantly higher than for noninducible patients. The respective one- and two-year survival rates were 94% and 84% in noninducible patients and 77% and 45% in inducible patients (p = 0.02). CONCLUSIONS: Electrophysiologic testing suggests an etiology for unexplained syncope in approximately 50% of patients and risk stratifies these patients with regard to long-term outcome. Patients who receive an ICD for the management of inducible ventricular tachycardia have a high incidence of spontaneous ventricular arrhythmias requiring ICD therapy. However, despite ICD implantation and frequent appropriate delivery of ICD therapies, patients with inducible ventricular tachycardia have a significantly worse prognosis than do those who are noninducible.

Aged↗

Catecholamine facilitated reentrant ventricular tachycardia: uncoupling of adenosine's antiadrenergic effects.

INTRODUCTION: Adenosine has no direct electrophysiologic function in ventricular tissue, but in the presence of cyclic adenosine monophosphate (cAMP), stimulation exerts a potent antiadrenergic effect. This effect has been exploited in the recognition and treatment of ventricular tachycardia (VT) due to cAMP-mediated triggered activity and automaticity, which are respectively terminated and suppressed by adenosine. However, the effects of adenosine on catecholamine-facilitated reentrant VT are unknown. A pivotal issue is whether termination of VT with adenosine is mechanism specific, or whether it represents a nonspecific antiadrenergic effect. The purpose of this study, therefore, was to define the effects of adenosine in a well-characterized group of patients with catecholamine-facilitated reentrant VT. METHODS AND RESULTS: Fourteen patients with catecholamine-facilitated reentry were studied. In the 12 patients with structural heart disease (including two with arrhythmogenic right ventricular dysplasia), adenosine (260 to 550 microg/kg) failed to slow or terminate VT. Two patients without structural heart disease had intrafascicular tachycardia confined to the left posterior fascicle, a calcium-dependent, verapamil-sensitive arrhythmia. In the absence of isoproterenol, verapamil terminated VT but adenosine did not. However, when isoproterenol was subsequently required for facilitation of tachycardia, adenosine terminated VT in both patients. CONCLUSION: Adenosine has no antiadrenergic (antiarrhythmic) effect in patients with catecholamine-facilitated VT due to structural heart disease. Patients with verapamil-sensitive, left posterior intrafascicular reentry have an unusual dual response to adenosine. In the unstimulated state, adenosine has no effect on basal inward calcium current and, therefore, no effect on VT. However, when induction of VT requires amplification of the inward calcium current through stimulation of cAMP, adenosine sensitivity of VT becomes manifest. These results indicate that with few exceptions, termination of VT with adenosine is strongly suggestive of a cAMP-mediated triggered mechanism rather than reentry.

Adenosine↗

Differential effects of adenosine on focal and macroreentrant atrial tachycardia.

INTRODUCTION: The effects of adenosine on atrial tachycardia (AT) remain controversial, and the mechanistic implications of adenosine termination have not been fully established. The purpose of this study was to elucidate the differential effects of adenosine on focal and macroreentrant AT and describe the characteristics of adenosine-sensitive AT. METHODS AND RESULTS: Thirty patients received adenosine during AT. Tachycardia origins were identified as focal or macroreentrant during invasive electrophysiologic studies. Responses to adenosine were analyzed and characterized as tachycardia termination, transient suppression, or no effect. Electrophysiologic studies demonstrated a focal origin of tachycardia in 17 patients. Adenosine terminated focal tachycardias in 14 patients (dose 7.3 +/- 4.0 mg) and transiently suppressed the arrhythmias in three others (dose 10.0 +/- 6.9 mg). A macroreentrant mechanism was demonstrated in 13 patients; adenosine terminated only one of these tachycardias and had no effect on the remaining 12 patients (dose 10.2 +/- 2.9 mg). Four classes of adenosine-sensitive AT were identified. Class I consisted of nine patients with tachycardia arising from the crista terminalis; these tachycardias also terminated with verapamil (4/4). Class II consisted of four patients with repetitive monomorphic AT arising from diverse sites in the right atrium; these either slowed or terminated in response to verapamil (2/2). Class III consisted of the three patients with transient suppression and demonstrated electropharmacologic characteristics consistent with an automatic mechanism, including insensitivity to verapamil (2/2). In the one patient with macroreentrant AT that was comprised of decremental atrial tissue, adenosine terminated tachycardia in a zone of decremental slow conduction (Class IV); this tachycardia slowed with verapamil. CONCLUSIONS: Adenosine-sensitive AT is usually focal in origin and arises either from the region of the crista terminalis (inclusive of the sinus node) or from diverse atrial sites with an incessant nonsustained repetitive pattern. Although most forms of macroreentrant AT are insensitive to adenosine, rarely macroreentrant AT with zones of decremental slow conduction can demonstrate adenosine sensitivity.

Adenosine↗

Ventricular response in atrial fibrillation: random or deterministic?

The ventricular response in atrial fibrillation is often described as "chaotic," but this has not been demonstrated in the strict mathematical sense. A defining feature of chaotic systems is sensitive dependence on initial conditions: similar sequences evolve similarly in the short term but then diverge exponentially. We developed a nonlinear predictive forecasting algorithm to search for predictability and sensitive dependence on initial conditions in the ventricular response during atrial fibrillation. The algorithm was tested for simulated R-R intervals from a linear oscillator with and without superimposed white noise, a chaotic signal (the logistic map) with and without superimposed white noise, and a pseudorandom signal and was then applied to R-R intervals from 16 chronic atrial fibrillation patients. Short-term predictability was demonstrated for the linear oscillators, without loss of predictive ability farther into the future. The chaotic system demonstrated high short-term predictability that declined rapidly further into the future. The pseudorandom signal was unpredictable. The ventricular response in atrial fibrillation was weakly predictable (statistically significant predictability in 8 of 16 patients), without sensitive dependence on initial conditions. Although the R-R interval sequence is not completely unpredictable, a low-dimensional chaotic attractor does not govern the irregular ventricular response during atrial fibrillation.

Aged↗