Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study.

The control system for an implantable rotary blood pump is not clearly defined. A detection system is considered to be necessary for pump flow monitoring and abnormal conditions such as back flow or a sucking phenomenon where the septum or left ventricle wall is sucked into the cannula, etc. The ultrasound flowmeter is durable and reliable but the control system should not be totally dependent on the flowmeter. If the flowmeter breaks, the rotary blood pumps have no control mechanism. Therefore, the authors suggest controlling the pumps by an intrinsic parameter. One left ventricular assist device (LVAD) calf model was studied where the flow rate and waveform of the pump flow proved to identify the sucking phenomenon. Thus, the pump flow rate was calculated from the required power, motor speed, and heart rate. The value of the coefficient of determination (R2) between the measured and estimated pump flow rate was 0.796. To estimate this abnormal phenomenon, 2 methods were evaluated. One method was the total pressure head in which the pump flow rate and motor speed were estimated. During normal conditions the total pressure head is 79.5 +/- 7.0 mm Hg whereas in the abnormal condition, it is 180.0 +/- 2.8 mm Hg. There was a statistical difference (p < 0.01). Another method is using a current waveform. There is an association between the current and pump flow waves. The current was differentiated and squared to calculate the power of the differentiated current. The normal range of this value was 0.025 +/- 0.029; the abnormal condition was 11.25 +/- 15.13. There was a statistical difference (p < 0.01). The predicted flow estimation method and a sucking detection method were available from intrinsic parameters of the pump and need no sensors. These 2 methods are simple, yet effective and reliable control methods for a rotary blood pump.

Animals↗

Gyro pump wear and deformation analysis in vivo study: creep deformation.

The Gyro pump has a double pivot bearing system to support its impeller. In this study, the integrity of the bearing system was examined after ex vivo studies. The pumps were implanted into calves and evaluated for different periods as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to a test of 30 days, 1 for 15 days, 4 for 14 days, 1 for 10 days, 1 for 7 days, 2 for 4 days, and 4 for 2 days. One additional pump was subjected to percutaneous cardiopulmonary support (PCPS) condition for 6 days (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an achieved clotting time (ACT) of 200-250 s during the LVAD study and 250-300 s during the PCPS study. After the experiment, the pumps were disassembled, and the wear and deformation of male and female bearings were analyzed. There were no dimensional changes on male bearings but there were on female bearings. Wear and deformation of the female bearings were calculated as follows: wear and deformation = (depth of female before pumping) - (depth after pumping). Thirteen assembled Gyro pumps were disassembled to measure the depth of the female bearings before pumping. There was no statistical relationship between the wear and deformation and the motor speed x driving period. From these results, the deformation was not due to wear but to the creep or elastic deformation. This study suggested that the double pivot bearing system of the Gyro pump is highly durable.

Animals↗

Antithrombogenicity evaluation of a centrifugal blood pump.

The Gyro C1E3 pump was developed not only for cardiopulmonary bypass but also as a short-term assist device. The main purpose of this study was to examine the correlation between the thrombus formation factor and the Gyro C1E3 pumps. Seven pumps were implanted into 3 calves and evaluated for different periods of duration as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to percutaneous cardiopulmonary support condition (PCPS) (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an activated clotting time (ACT) of 200-250 during the LVAD study and 250-300 during the PCPS study. After the experiment, the pumps were disassembled and examined. In cases where there were any blood-derived deposits inside the pumps, the dry weight of these thrombi that adhered to the bearing area of the pump was measured. A multiple correlation was attempted to speculate possible thrombus formation. The estimated dry weight of thrombi was calculated from pump flow rate, pumping day, motor speed, and activated clotting time. This equation was estimated dry weight of thrombi = 1.140 x pump flow rate -0.001 motor speed + 1.652 pumping time -0.041 x ACT + 2.198 R2 = 0.944. This study suggested that there was a possibility to calculate the amount of adhered thrombus formation from pump flow rate, motor speed, pumping day, and ACT.

Animals↗

Particles released from the Gyro C1E3 during simulated extracorporeal circulation.

Evaluation of released particles from the blood pump during extracorporeal circulation is an important aspect because the particles may cause microembolism. The Gyro C1E3 is a centrifugal blood pump that has an impeller suspended by double pivot bearings inside the housing; therefore, it is important to evaluate the released particles. The C1E3 was driven for 14 days to simulate clinical left ventricular assist device (LVAD) and percutaneous cardiopulmonary support (PCPS). Also, a roller pump was driven for 2 days as a comparison. Released particles were weighed and examined by SEM. After 14 days of pumping, the particles from the C1E3 were 238.6 microg in an LVAD condition. The particles with the roller pump were 270.2 microg after only 2 days. Average particle sizes with the roller pump and C1E3 were 3.7 and 0.6 microm, respectively. These results suggest that the Gyro C1E3 substantially reduces the risk of microembolism from released particles.

Biocompatible Materials↗

Impeller design for a miniaturized centrifugal blood pump.

The impeller design for a miniature centrifugal blood pump is an important consideration since the small diameter impeller requires higher rotational speed, which may cause more blood trauma compared to the larger diameter impeller. Three different impeller vanes (straight vanes with a height of 4 mm and 8 mm, and 8 mm curved vanes) of which the diameter was 35 mm were subjected to hydraulic performance and hemolysis tests in the same pump housing. Both straight vane impellers attained left ventricular assist condition (5 L/min against 100 mm Hg) at 2,900 rpm while the curved vane required 3,280 rpm. There was no significant hemolysis difference between the tall and short vanes. The curved impeller vanes did not exhibit sufficient hydraulic performance when compared to the straight vanes. The straight vane impellers, even with different heights, were incorporated into the same pump housings, and the vane heights did not drastically change the hydraulic performance or hemolysis.

Equipment Design↗

Control system for an implantable rotary blood pump.

Rotary blood pumps can be used for long-term left ventricular assist devices. These pumps have several advantages over the conventional pulsatile pumps including smaller size, higher efficiency, and simple design and construction. However, one of the difficulties associated with the rotary blood pump is the proper control method to maintain an optimum flow rate in different physiological conditions. The rotary blood pump can be controlled by two methods. The first is to utilize the measured pump flow rate from its servo signal. The second is to detect and avoid abnormal pumping conditions such as; back flow and sudden increase in the pressure head. This abnormal situation typically occurs from excessive suction of blood when there is a functional or mechanical occlusion in the inflow cannula. The ultrasound flow meter is durable and reliable but it is difficult to continually monitor the blood flow rate of an implantable pump. Therefore, another method is needed instead of the continuous flow monitoring. One chronic calf having an LVAD was subjected for the development of this control system. This calf survived more than 6 months. Voltage, current, motor speed, heart rate and the pump flow rate were recorded and stored at 30-min intervals in a computer. Utilizing these parameters, attempts were made (1) to achieve indirect flow assessments and (2) to reveal abnormal operating parameters of the centrifugal pump (1). Indirect flow measurement, the predicted pump flow rate was calculated from these pump derived parameters (required power, motor speed and heart rate). The value of the coefficient of determination (R) between the measured and estimated pump flow rate was 0.796. (2) Abnormal operating indicator, there was an association between the required current and pump flow waves. The current was differentiated, and then calculated to the power of the differentiated current. The normal range of this value was 0.02+/-0.54. In abnormal conditions, this abnormal operating indicator increased 500 times. The predicted flow estimation method and abnormal operating indicator were available from intrinsic operating parameters of the pump and need no sensors. These two methods were simple, yet they are possibly effective and reliable servo control methods for a rotary blood pump.

Animals↗

A new control method that estimates the backflow in a centrifugal pump.

The rotary blood pump will be widely used in the near future as an implantable left ventricular assist device (LVAD). However, one obstacle for the centrifugal pump is a control method that can maintain an optimum flow rate in a physiological condition. Thus, the object of this study is to develop this optimum control system for the centrifugal pump. If the heart function and pump efficiency are stable, the ratio of the systole current to the the diastole current (S/D) will be a fixed value. However, if the heart function and pump efficiency are unstable, S/D will not be a fixed value. This control system was investigated with a calf that was subjected to an ex vivo LVAD study. The LVAD was a Gyro C1E3 centrifugal pump. The pump flow rate was changed to 1.5, 3.5, 5.2, and 6.2 L/min. According to the changes of the pump flow rates, the S/D values were 1.01 +/- 0.01, 1.06 +/- 0.05, 1.03 +/- 0.01, and 1.03 +/- 0.01, respectively. There was no statistical difference among the 3 groups. In a separate experiment, the backflow condition S/D was 1.88 +/- 0.6, and the normal condition S/D was 1.35 +/- 0.5. There was a statistical difference between the 2 groups. The results of this study suggest that S/D is not influenced by the pump flow rate. However, the S/D was changed when the pump was in a backflow condition. This method will be useful in controlling a centrifugal pump requiring only electrical current information.

Analysis of Variance↗

Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device.

The Gyro pumps were developed for long-term circulatory support. The first generation Gyro pump (C1E3) achieved 1 month paracorporeal circulatory support in chronic animal experiments; the second generation (PI702) implantable ventricular assist device (VAD) was successful for over 6 months. The objective of the next generation Gyro pump is for use as a long-term totally implantable VAD and for pediatric circulatory support. This tiny Gyro pump (KP101) was fabricated with the same design concept as the other Gyro pumps. The possibility of an implantable VAD was determined after performance and hemolysis test results were compared to those of the other Gyro pumps. The pump housing and impeller were fabricated from polycarbonate with an impeller diameter of 35 mm. The diameter and height of the pump housings are 52.3 mm and 29.9 mm, respectively. At this time, a DC brushless motor drives the KP101, which is the same as that for the C1E3. The pump performance was measured in 37% glycerin water at 37 degrees C. Hemolysis tests were performed utilizing a compact mock loop filled with fresh bovine blood in a left ventricular assist device (LVAD) condition at 37 degrees C. The KP101 achieved the LVAD conditions of 5 L/min and 100 mm Hg at 2,900 rpm; generated 10 L/min against 100 mm Hg at 3,200 rpm; 3 L/min against 90 mm Hg at 2,600 rpm; and 2 L/min against 80 mm Hg at 2,400 rpm. In addition, the pump efficiency during this experiment was 12.5%. The other Gyro pumps. that is, the C1E3, PI601, and PI701, in an LVAD condition require 1,600, 2,000, and 2,000 rpm, respectively. The KP101 produced a normalized index of hemolysis (NIH) value of 0.005 g/100 L. With regard to the NIH, the other Gyro pumps, namely the C1E3, PI601, and PI701 demonstrated 0.0007, 0.0028, and 0.004 g/100 L, respectively. The KP101 produced an acceptable pressure flow curve for a VAD. The NIH value was higher than that of other Gyro pumps, but is in an acceptable range.

Equipment Design↗

Protein adsorption onto ceramic surfaces.

Ceramics seldom have been used as blood-contacting materials. However, alumina ceramic (Al2O3) and polyethylene are incorporated into the pivot bearings of the Gyro centrifugal blood pump. This material combination was chosen based on the high durability of the materials. Due to the stagnant flow that often occurs in a continuous flow condition inside a centrifugal pump, pivot bearing system is extremely critical. To evaluate the thombogenicity of pivot bearings in the Gyro pump, this study sought to investigate protein adsorption, particularly albumin, IgG, fibrinogen, and fibronectin onto ceramic surfaces. Al2O3 and silicon carbide ceramic (SiC) were compared with polyethylene (PE) and polyvinylchloride (PVC). Bicinchoninic acid (BCA) protein assay revealed that the amount of adsorbed proteins onto Al2O3 and SiC was significantly less than that on PVC. The sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) indicated that numerous proteins adsorbed onto PVC compared to PE, Al2O3, and SiC. Identification of adsorbed proteins by Western immunoblotting revealed that the adsorption of albumin was similar on all four materials tested. Western immunoblotting also indicated lesser amounts of IgG, fibrinogen, and fibronectin on Al2O3 and SiC than on PE and PVC. In conclusion, ceramics (Al2O3 and SiC) are expected to be thromboresistant from the viewpoint of protein adsorption.

Adsorption↗

Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump.

A totally implantable centrifugal artificial heart has been developed in which a pivot bearing supported centrifugal pump is used as a blood pump. The following have been adopted as blood contacting materials in our pump: titanium alloy (Ti-6A1-4V) for the housing and impeller, alumina ceramic (Al2O3) for the male pivots, and ultrahigh molecular weight polyethylene (PE) for the female pivots. Greater antithrombogenicity is required for an implantable blood pump. To examine the thrombogenicity of these materials, we evaluated in vitro platelet adhesion and activation, which may play key roles in thrombogenesis on foreign surfaces. Ti-6A1-4V, Al2O3, and PE were compared with polycarbonate (PC), silicone carbide (SiC), and pure titanium (pTi). Platelet adhesion was assessed using monoclonal antibody (CD61) directed against glycoprotein IIIa. Platelet activation was evaluated by measuring P-selectin (GMP-140) released from irreversibly activated platelets. Each material with a surface area of 16.6 cm2 was incubated with 2.5 ml of plasma or 2.5 ml of heparinized fresh whole blood for 3 h at 37 degrees C. The optical density (OD) at a wavelength of 450 nm for CD61 was 0.93+/-0.35 in PC, 0.34+/-0.13 in PE, 0.27+/-0.13 in pTi, 0.26+/-0.01 in Al2O3, 0.21+/-0.04 in SiC, and 0.12+/-0.12 in Ti-6A1-4V. The GMP-140 levels of the tested materials were not significantly different from the control value (45.9+/-7.2 ng/ml). These results indicate that Al2O3, PE, and Ti-6A1-4V, which are incorporated into our implantable centrifugal pump, have satisfactory antithrombogenic properties in terms of platelet adhesion. However, platelet activation by any material was not observed under the static condition in this study.

Alloys↗

Biocompatibility of alumina ceramic and polyethylene as materials for pivot bearings of a centrifugal blood pump.

The double pivot bearings in the Gyro C1E3 centrifugal blood pump incorporate a high-purity alumina (Al2O3) ceramic and an ultra-high-molecular-weight polyethylene (UHMWPE). This centrifugal pump has been developed as a completely sealless pump for long-term usage. The combination of Al2O3 and UHMWPE are the materials of choice for the acetabular bearing in artificial joints, which have proven to be clinically reliable for over 10 years. Previous studies have examined the biocompatibility of Al2O3 and UHMWPE as bulky implant materials. The present study investigated this material as a blood-contacting material using a standard assessment in vitro and in vivo analysis. The examined items were systemic toxicity, sensitization (guinea pig maximization test), cytotoxicity (elution test), mutagenicity (Ames test), direct contact hemolysis, and thrombogenicity. The studies were performed according to the United States Pharmacopoeia and published previous studies. The samples of both Al2O3 and UHMWPE demonstrated no differences from the negative controls in all tests. These findings indicate that both Al2O3 and UHMWPE are biocompatible materials for double-pivot bearings in the centrifugal blood pump.

Aluminum Oxide↗

Mapping of pump efficiency on the pressure-flow curve of a centrifugal blood pump.

Because pump efficiency is closely related to heat generation and blood trauma in a centrifugal blood pump, it is quite important to study pump efficiencies in a variety of conditions. In the present study, pump efficiencies were mapped on the pressure head-flow rate curves of 4 different pumps; BioMedicus BioPump (BP-80), Nikkiso (NK), Gyro C1E3, and Gyro PI601 (diameter of the impeller, NK: 50 mm, C1Ee3: 65 mm, and PI601: 50 mm). The mapping of pump efficiency revealed the following findings. First, the cone type (BP-80) has less pump efficiency than the impeller type (NK and C1E3); second, the miniaturization of the C1E3 to the PI601 has resulted in an increase in pump efficiency; and third, the diameter of the impeller may contribute to the pump efficiency of an im peller type pump. The mapping of the pump efficiency, as demonstrated in this study, is useful for the analysis of hydraulic pump performance in a wide range of clinically applied conditions.

Blood Flow Velocity↗

Mechanical white blood cell damage in rotary blood pumps.

Mechanical trauma of white blood cells (WBC) due to the operation of a rotary blood pump was examined, using a simple method of trypan blue dye exclusion test for a cell viability measurement. The degree of WBC trauma was investigated using a roller pump (RP) and 3 commercially available centrifugal pumps (Bio-Medicus [BP], Capiox [CP], Nikkiso [NK]), and compared with the red blood cell (RBC) trauma. Each pump was operated 3 times at a flow rate of 5 L/min against the total pressure head of 350 mm Hg for 6 h in a mock circuit with 400 ml of fresh bovine blood. Blood was sampled at 2 h intervals measuring plasma free hemoglobin concentration and the percentage of damaged WBC in the trypan blue dye exclusion test. Each pump demonstrated a linear increase in the degree of WBC trauma, and there were differences among the tested pumps (RP > BP > CP > NK). These findings were similar to those of the free hemoglobin measurements. To compare the degree of RBC and WBC trauma, the probability (gamma, omega) of RBC and WBC to be damaged was calculated, respectively. gamma = delta DRBC/delta N, omega = delta DWBC/delta N where DRBC and DWBC are the ratios of the damaged RBC and WBC, respectively, and N is the passing number defined as Qt/V (Q, flow rate; t, time; V, circulating volume). The data of this study demonstrated that the omega value was approximately 20 times or more greater than the gamma equally in all the tested pumps. This suggests that a WBC is more vulnerable to mechanical damage by a rotary blood pump than a RBC.

Analysis of Variance↗

Material of the double pivot bearing system in the Gyro C1E3 centrifugal pump.

A double pivot bearing system is adopted for the Gyro C1E3 centrifugal blood pump to achieve a completely sealless structure that prevents blood leakage and thrombus formation around the shaft. The double pivot bearing system is also a critical factor for blood trauma and durability of the C1E3 pump. This study focuses on the double pivot bearing material. The pump with the male ceramic and female polyethylene pivots (PE) was compared with the pump with the male ceramic and female ceramic pivots (CRM), pertaining to stability of the impeller spinning motion, hemolysis, and durability. At first, the wear rate of the pivots was recorded after operating the pumps in various rotational speeds. As for hemolysis, in vitro tests were carried out using fresh bovine blood in 2 conditions (5 L/min, 350 mm Hg and 5 L/min, 100 mm Hg). Then, stability of the spinning motion was investigated by evaluating the vibration of the pump. The two pumps with different female pivots were operated identically at 2,700 rpm, and the vibration signals were measured using an accelerometer that was mounted on the top of the pump housing. The following findings were obtained in this study. The wear sites were different between the PE and CRM. Most of the wear occurred at the top female polyethylene pivot in the PE. In contrast, most of the wear occurred at the top male ceramic pivot in the CRM. In addition, the amount of the initial wear was less and the wear rate was lower in the PE than in the CRM. The hemolysis caused by the PE was less than the hemolysis caused by the CRM. The vibration signals of the PE had less amplitude and a narrower range of frequency than the vibration signals of the CRM. In conclusion, the combination of materials male ceramic-female polyethylene are superior to the male ceramic-female ceramic for the double pivot bearing system of the Gyro C1E3 centrifugal pump because of less vibration, less hemolysis, and less wear.

Animals↗

Eccentric inlet port of the pivot bearing supported Gyro centrifugal pump.

An eccentric inlet port is a unique feature of the pivot bearing supported Gyro Compact-1 Eccentric Inlet Port Model 3 (C1E3) centrifugal pump, a completely sealless centrifugal pump. The latest C1E3 has an eccentric inlet port with a 30 degree vertical angle. To investigate the adequacy of this 30 degree angle, flow visualization studies and in vitro hemolysis tests were performed, comparing 4 pumps, each with a different angle of the eccentric inlet port (0, 30, 60, and 90 degrees). The flow visualization study utilizing a tracer method focused on the flow pattern just distal to the inlet port of each pump, and each pump was operated at 5 L/min against 100 mm Hg and 5 L/min against 350 mm Hg. In the pumps with angles of 90 and 60 degrees, the flow direction changed horizontally, causing a vortex formation. In the pump with the 30 degree angle, the inflow did not change its course, resulting in minimal space for vortex formation. In the pump with the 0 degree angle, the inflow collided with the pump housing, resulting in a small vortex formation along the housing surface. The in vitro hemolysis tests at 5 L/min against 350 mm Hg revealed that the pump with the 30 degree angle was the least hemolytic and the pump with the 90 degree angle was the most hemolytic among the 4 pumps. These results suggest that the angle of the eccentric inlet port of the Gyro C1E3 pump should be 30 degrees to have less vortex formation and less red blood cell trauma.

Animals↗

Vibration assessment for thrombus formation in the centrifugal pump.

To clarify the correlation of vibration and thrombus formation inside a rotary blood pump, 40 preliminary vibration studies were performed on pivot bearing centrifugal pumps. No such studies were found in the literature. The primary data acquisition equipment included an accelerometer (Isotron PE accelerometer, ENDEVCO, San Juan Capistrano, CA, U.S.A.), digitizing oscilloscope (TDS 420, Tektronix Inc., Pittsfield, MA, U.S.A.), and pivot bearing centrifugal pumps. The pump impeller was coupled magnetically to the driver magnet. The accelerometer was mounted on the top of the pump casing to sense radial and axial accelerations. To simulate the 3 common areas of thrombus formation, a piece of silicone rubber was attached to each of the following 3 locations as described: a circular shape on the center bottom of the impeller (CI), an eccentric shape on the bottom of the impeller (EI), and a circular shape on the center bottom casing (CC). A fast Fourier transform (FFT) method at 5 L/min against 100 mm Hg, with a pump rotating speed of 1,600 rpm was used. The frequency response of the vibration sensors used spans of 40 Hz to 2 kHz. The frequency domain was already integrated into the oscilloscope, allowing for comparison of the vibration results. The area of frequency domain at a radial direction was 206 +/- 12.7 mVHz in CI, 239.5 +/- 12.1 mVHz in EI, 365 +/- 12.9 mVHz in CC, and 163 +/- 7.9 mVHz in the control (control vs. CI p = 0.07, control vs. EI p < 0.001, control vs. CC p < 0.001, EI vs. CC p < 0.001, CI vs. CC p < 0.001). Three types of imitation thrombus formations were roughly distinguishable. These results suggested the possibility of detecting thrombus formation using vibration signals, and these studies revealed the usefulness of vibration monitoring to detect thrombus formation in a centrifugal pump.

Analysis of Variance↗

Quantitative approach to control spinning stability of the impeller in the pivot bearing-supported centrifugal pump.

The Gyro C1E3 pump has been developed as a completely sealless centrifugal pump driven by a magnetic coupling system for long-term usage. The Gyro C1E3 pump is a pivot bearing-supported pump in which the impeller is supported with the top and bottom pivot bearings. In the Gyro C1E3 pump, the impeller spinning is affected by the force balance between the floating force (Ff[N]) of the hydrodynamic effect and the magnetic thrust force (Tf[N]). The authors quantitatively investigated the floating force of the impeller in vitro to determine the magnetic coupling distance (MCD[mm]) that would result in stable impeller spinning. In vitro tests were performed using a loop filled with 37% glycerin solution to obtain the relationship between the MCD and floating speed (Rf, rotational speed when the impeller starts floating [rpm]) and the relationship between the MCD and Tf. From the obtained relationships, we calculated Ff and determined the relationship between the Ff and the rotational speed (R). Furthermore, we determined the relationship between d (minimum required MCD [mm]) and R from the results of determining the relationship of the MCD and Tf and of the Ff and R. The following relationships were obtained: Rf = 6.24 x 10(4) x MCD-1.35; Tf = 5.27 x 10(3) x MCD-2.29; Ff = 4.71 x 10(-6) x RPM1.69; and d = 9.02 x RPM-0.85 where RPM is the rotational speed. It was demonstrated that the floating force of the impeller is a function only of the rotational speed in the pivot bearing-supported Gyro C1E3 pump. The floating force is estimated to be 10 N to 40 N at rotational speeds of 1,500 rpm to 3,000 rpm at which the Gyro pump may be used in most clinical situations. It would be possible to control the impeller position of the Gyro pump automatically at the stable spinning condition by controlling the adequate magnetic coupling distance based upon its relationship with the rotational speed which was obtained in this study.

Blood Viscosity↗

The simple in vitro thrombogenic test: modified methods for same priming pumps.

The improvement of antithrombogenicity is one of the major objectives for the development of blood pumps. Previously we reported that an in vitro thrombogenic test was useful as a pilot study, especially to predict thrombogenic areas. In this study we modified the method for testing pumps with identical priming volumes by eliminating the blood reservoir. Identical compact mock loops (priming volume of 53 ml, without pump) were constructed and tested with the same priming volume of Nikkiso centrifugal pumps, noncoated verus heparin-coated. Two pumps were run simultaneously using the same source of fresh heparinized human blood (activated clotting time [ACT] 150-250 s) for 4 or 6 h. Results indicated that the heparin-coated pump had a longer thrombus free period than the noncoated one. The thrombi location and forms were consistently in the same places the in vivo study had identified. It is suggested that this modified in vitro thrombogenic test is a feasible pilot study, as well as the one previously reported. The minimal priming volume will allow evaluation of multiple pumps simultaneously with the same source blood.

Anticoagulants↗