PubMed Health⌕ Search

Biomedical subjects

K Markstaller

Publications and source records attributed to K Markstaller.

At least 19 recordsLinked to original sources

Radiological imaging as the basis for a simulation software of ventilation in the tracheo-bronchial tree.

The inhaled route is a promising new way for administering drugs to the human body. Flow and particle deposition in the human respiratory tract depends on the individual's anatomy as well as on the drug composition. A European Framework V Program supported project is currently developing a simulation tool for assessment of drug distribution and deposition. This tool relies heavily on the input of radiological data sets, which are obtained in humans. Both high temporal and spatial resolutions are required, and CT and MRI (including hyperpolarized helium-3 MRI) are applied. The radiological data are integrated into computation fluid dynamics software, which is capable of assessing air-flow profiles and compartmental behaviours. This is complemented by pharmacokinetic models, which should result in a simulation tool that will be of use for the theoretical design of new inhaled therapies. This article describes the special imaging requirements of each region of the respiratory tract and the feasibility of these sophisticated radiological techniques with a view of using these data in a simulation model of the lung.

Administration, Inhalation↗

Assessment of a single-acquisition imaging sequence for oxygen-sensitive (3)He-MRI.

MRI of the lungs using hyperpolarized helium-3 ((3)He) allows the determination of intrapulmonary oxygen partial pressures (p(O2)). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure p(O2) by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary p(O2) are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of (3)He hyperpolarization within the lungs were performed to evaluate the accuracy of this measurement technique, and its limitations.

Computer Simulation↗

3He-MRI-based vs. conventional determination of lung volumes in patients after unilateral lung transplantation: a new approach to regional spirometry.

BACKGROUND: To use 3Helium (3He)-MRI in patients with unilateral lung grafts to assess the contributions of graft and native lung to total ventilated lung volume, and second to compare conventional measurements of intrapulmonary gas volume (spirometry, body plethysmography) with image-based volumetry of ventilated lung parenchyma visualized by hyperpolarized 3He-MRI. METHODS: With Ethics Committee approval, five patients with single lung transplantation (SLTX) for idiopathic pulmonary fibrosis (IPF) underwent both conventional pulmonary function testing (PFT) and 3He-MRI of the lung. Intrapulmonary gas volume (GV) during the inspiratory breathhold for 3He-MRI was calculated from measured functional residual capacity (corrected for supine position) and inspired tidal volume. Image-based global and regional lung volumetries (LV) were performed in three-dimensionally reconstructed 3He-MR images (corrected for the fraction of tissue and blood). RESULTS: Transplanted lungs were characterized by a homogeneous distribution of signal intensity, whereas the native lungs of the patients suffering from IPF displayed an inhomogeneous signal distribution pattern with numerous round or wedge-shaped ventilation defects. Total ventilated lung volume determined by 3He-MRI correlated well with PFT-based measurements, but with a systematic overestimation of the 3He-based lung volumetry of approximately 20%. Functioning lung grafts contributed 66+/-6% and their corresponding native IPF lungs 34+/-6% to total ventilated volume (P<0.05; mean+/-SD). CONCLUSION: 3Helium-MRI of the lung offers a novel approach to regional determination of ventilated lung volume, including its blood and tissue compartments. The advantage of this technique over computed tomography or ventilation scintigraphy is the lack of radiation exposure, and hence its repeatability. Follow up of SLTX patients with this new technique may allow the monitoring of functional and structural developments of grafted lungs with better sensitivity and specificity than PFT.

Female↗

[Pulmonary structure and function].

Computed tomography (CT) is the method of choice for the morphological assessment of pulmonary structure. Airways. pulmonary parenchyma and their pathologies are shown with high spatial resolution. Airway diseases exhibit bronchial dilatation, wall thickening and an increased visibility in the lung periphery. CT is also the imaging gold standard for the detection and the characterisation of emphysema because a high degree of concordance with histopathological studies. Centrilobular, panlobular and paraseptal emphysema can be differentiated. CT can also provide functional information. Paired inspiratory and expiratory scans with or without spirometric triggering allow to evaluate obstruction of the small airways (airtrapping). On the basis of CT-data lung volumes can be semented. Cine-CT allows to visualise motion of the central airways. e.g. in tracheomalacia, to assess regional ventilation to calculate pulmonary time constants. and to display the co-ordinated or dissociated motion of the thoracic wall and the diaphragm. Beyond the mere high-resolution visualisation of the structure of the lung the application of these CT-strategies makes a regional assessment of pulmonary function possible.

Humans↗

[Determination of the distribution volume of contrast media solutions injected intrahepatically: pre-pilot studies for intratumoral gene therapy].

PURPOSE: Determination of the intrahepatic distribution volume of two contrast media (CM) by CT-guided application in an ex-vivo and an in-vivo model (pig liver). MATERIAL AND METHODS: In pig livers ex-vivo and in-vivo, 131 CT-guided injections of two different CM (Imagopaque(R), Visipaque(R)) were performed using catheters and cannula with and without side-holes and documented by spiral CT. The distribution pattern was assessed visually: interstitial, subcapsular, vascular/tubular, the distribution volume was quantified using a density mask (thresholds 70/400 HE). RESULTS: Purely interstitial applications were achieved more frequently in-vivo than ex-vivo (p = 0.001). There were no relevant differences between the two CM. Catheters without side-holes led to more interstitial CM depots than catheters with side-holes (p = 0.005). The mean distribution volume was larger with catheters with side-holes (ex-vivo 103 cm(3), in-vivo 19 cm(3)) than with catheters without side-holes (ex-vivo 67 cm(3), in-vivo 13 cm(3)) (p = 0,01). At the same time, the mean density with catheters with side-holes (102 HE) was lower than with catheters without side-holes (115 HE) (p = 0.005). CONCLUSION: Marked differences of the CM distribution volumes were observed between ex-vivo and in-vivo studies in the pig model. Catheters with side-holes are far superior to catheters without.

Animals↗

Hyperpolarised gases in magnetic resonance: a new tool for functional imaging of the lung.

In magnetic resonance imaging (MRI), nuclear spins are the source of the image signal. In the lung, low-proton spin density in alveolar gas and abundant gas-tissue interfaces substantially impair conventional native 1H-MRI. Spin polarisation can be increased in two non-radioactive noble gas isotopes, 3He and 129Xe, by exposure to polarised laser light. When inhaled, such "magnetized" gases provide high-intensity MR images of the pulmonary airspaces. Thus, hyperpolarised gas (HPG) MRI opens up new routes to a) morphologic imaging of airways and alveolar spaces, and b) analysis of the intrapulmonary distribution of inhaled aliquots of these tracer gases; c) diffusion-sensitive MRI-techniques allow mapping of the "apparent diffusion coefficient" (ADC) of 3He within lung airspaces, where ADC is physically related to local bronchoalveolar dimensions; d) also, 3He magnetisation decays in an oxygen-containing atmosphere at a rate proportional to ambient PO2. This property allows image-based determination of regional broncho-alveolar PO2 and its decrease during a breathhold. Currently, these modalities of functional lung imaging are being assessed by several European and American research groups in animal models, human volunteers and patients. First results show good imaging quality with excellent spatial and unprecedented temporal resolution, and attest to the reproducibility, feasibility and safety of the technique. Regionally impaired ventilation of both structural and functional origin is detected with high sensitivity, e.g. in smokers, asthmatics, patients with COPD or after lung transplantation. Studies into regional ADC and PO2 measurement demonstrate good agreement with reference methods and physiological predictions. The present limitations of HPG-MRI include the HPG production rate and the US and EU health authorities' still pending final approval for clinical use.

Adult↗

Dynamic (19)F-MRI of pulmonary ventilation using sulfur hexafluoride (SF(6)) gas.

A new method for dynamic imaging of pulmonary wash-in and wash-out kinetics of inhaled sulfur hexafluoride (SF(6)) gas was developed. Measurements at the fluorine-19 Larmor frequency were performed in pigs using a gradient echo pulse sequence with 0.5 ms echo time and a measurement time of 9.1 s per image. Dynamic MRI was performed during wash-in and wash-out of SF(6) gas in mechanically ventilated porcine lungs. A postprocessing strategy was developed for quantitative determination of wash-out time constants in the presence of noise. Mean wash-out constants were 4.78 +/- 0.48 breaths vs. 4.33 +/- 0.76 breaths for left and right lung when ventilation was performed with low tidal volume, and 1.73 +/- 0.16 breaths vs. 1.85 +/- 0.11 breaths with high tidal volume ventilation. In conclusion, breath-hold MRI of SF(6) gas is feasible in large animals. Moreover, regional wash-in and wash-out kinetics of SF(6) can be determined noninvasively with this new method. Potential human applications are discussed. Magn Reson Med 45:605-613, 2001.

Animals↗

[Multi-rotation CT and acute respiratory distress syndrome. Animal experiment studies].

PURPOSE: Aim of the study was to investigate alveolar inspiration and expiration using multiscan CT. Results of a visual assessment using a scoring system were compared with density ranges known to represent alveolar ventilation best. METHOD: Pigs were examined before and after lavage-induced ARDS. All animals were examined using dynamic multiscan CT. The visual assessment was done by a scoring system proposed by Gattinoni. The results were compared with planimetric determination of defined density ranges. RESULTS: In the healthy lung, the visual analysis showed higher scores at lower airway pressures with a marked gradient, whereas at higher pressures neither opacities nor gradients were observed. In ARDS-lungs, the scores were double as high as in healthy lungs at low pressures. At the same time the differences between inspiration and expiration were minor. There was good correlation between lung density measurements and lung opacities under different airway pressures. In healthy lungs, the greatest area increase is found between -910 and -700 HU. The biggest area growth in the ARDS-model is observed between -910 and -300 HU. CONCLUSION: Dynamic multiscan CT allows for determining different ventilation-relevant lung compartments and lung density ranges.

Animals↗

[A software tool for automatic image-based ventilation analysis using dynamic chest CT-scanning in healthy and in ARDS lungs].

PURPOSE: Density measurements in dynamic CT image series of the lungs allow one to quantify ventilated, hyperinflated, and atelectatic pulmonary compartments with high temporal resolution. Fast automatic segmentation of lung parenchyma and a subsequent evaluation of it's respective density values are a prerequisite for any clinical application of this technique. MATERIAL AND METHODS: For automatic lung segmentation in thoracic CT scans, an algorithm was developed which uses (a) different density masks, and (b) anatomic knowledge to differentiate heart, diaphragm and chest wall from ventilated and atelectatic lung parenchyma. With Animal Care Committee approval, the automated technique was tested in 8 anaesthetized ventilated pigs undergoing dynamic CT before and after induction of lavage-ARDS. Images were acquired in one supradiaphragmatic, cross-sectional slice (temporal resolution of 100 ms; slice thickness of 1 mm, high resolution reconstruction algorithm). In 120 CT images the total pixel number and the calculated MLD from the automatically segmentated lung were compared to the values obtained from an interactive lung segmentation. RESULTS: The software tool was able to read all image series (DICOM standard). Automatic and interactive segmentation were in high agreement (R(2) = 0.99 for the total number of pixels and the MLD). Originally, the most frequent error was misclassification of atelectasis as extrapulmonary solid tissue. CONCLUSION: An automatic software tool is presented for lung segmentation in healthy lungs and in ARDS. Aerated lung and atelectasis were identified with high accuracy. This post-processing tool allows for a quantitative, CT based assessment of ventilation and recruitment processes in the lung. Thus, it may help to optimize ventilation patterns in patients with ARDS.

Animals↗

[Dynamic imaging of the nasal cavity and the paranasal sinuses with polarized 3helium MRI].

PURPOSE: Reduced or blocked ventilation of the paranasal sinuses is probably the most important factor in the development of sinusitis. Recently, the use of optically polarized noble gas isotopes has attracted increasing interest for use in a variety of promising MR applications. The aim of this study was to test the feasibility of imaging and visualization ventilation of the nasal cavity and paranasal sinus in MR by inhalation of hyperpolarized (3)helium. The goal was to evaluate ventilation defects of the paranasal sinuses. VOLUNTEERS AND METHODS: Three volunteers were enrolled in the study. (3)Helium was polarized to 40 - 50 % by direct optical pumping. 300 ml of 100 % (3)helium were administered in the left nasal vestibule through a glass tube. With a closed contralateral nasal vestibule, the Valsalva maneuver was performed twice. Using a dedicated application unit, which is also used in MR imaging of the lung, an exact amount of (3)helium gas was administered at the beginning of inspiration. Measurements were carried out on a clinical 1.5 T scanner. Coronal images of the nasal cavity and paranasal sinuses were acquired using ultrafast gradient-echo pulse sequence (TR = 2 ms, TE = 0.7 ms, FA < 2 degrees, 75 x 128, FOV = 500) with an image aquisition time of 130 ms. RESULTS: The oral cavity and nasal cavities display a very high signal intensity after inhalation of polarized (3)helium gas. The signal intensity in the left maxillary sinus was higher compared to the right one. The mean signal intensity on the left side was 526 +/- 86 and on the right side 336 +/- 102. The left and right frontal sinus and ethmoid sinus only show signal of hyperpolarized (3)helium after two Valsalva maneuvers. Because of the low signal intensity of the frontal and ethmoid cells their visualization was incomplete. The signal to noise ratio was 14.1 for the left maxillary sinus, 8.9 for the right side, 6.3 for the left ethmoid sinus, 5.8 for the right side and 6.6 for the left frontal sinus and 7.8 for the right side. CONCLUSION: (3)Helium MR allows imaging of the nasal cavity and the paranasal sinuses. Perhaps this method could be a new tool to visualize the ventilation of the maxillary sinus without ionizing radiation. Interpretations about the ventilation of the frontal and ethmoid cells remain speculative.

Administration, Inhalation↗

Temporal dynamics of lung aeration determined by dynamic CT in a porcine model of ARDS.

We used dynamic CT to identify two different time constants of lung aeration and their individual contribution to the total increase in cross-sectional lung area in healthy and experimentally damaged lungs. In five healthy pigs, inflation and deflation between 0 and 50 cm H2O was imposed during dynamic (250 ms/image) CT acquisition, and repeated after experimental lung injury by saline lavage. The fractional areas of density ranges, which represent aerated lung parenchyma, were determined planimetrically, and their time for expansion during the manoeuvre was fitted using a bi-exponential model. Thus, two compartments, their sizes, i.e. their relative contributions to lung area aerated by the manoeuvre, and their specific time constants (tau) were sought. Healthy lungs were characterized best by a one-compartmental behaviour with one tau only, both during inflation (median tau=0.5 s; range 0.4-0.6 s) and deflation (1.2 s; 1.1-1.3 s). In damaged lungs two compartments were found both during inspiration and expiration, with 86% (78-87%) of the recruitable lung area following a short tau of 0.5 s (0.5-0.6), and 14% (13-22%) following a longer tau of 9.1 s (8-16.8 s) during inflation. During expiration, damaged lungs had a short tau of 0.8 s (0.5-1.0 s) for 94% (84-100%) of deflated lung area, and a longer tau of 26.5 s (7.1-34.3 s) for 6% (0-16%). We conclude that dynamic CT indicates the relative size and temporal behaviour of functional compartments in normal and abnormal lungs. Our findings suggest that after lung damage, cyclic ventilation with inspiratory periods of <10 s duration will not achieve maximum recruitment for a chosen inspiratory pressure. In ARDS, the short expiratory tau predisposes to atelectasis formation if expiratory times are >1 s.

Animals↗

Volumetry of ventilated airspaces by 3He MRI: preliminary results.

RATIONALE AND OBJECTIVES: To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI. METHODS: 3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated. RESULTS: Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,348 +/- 744 mL and mean FRC was 3,422 +/- 817 mL, with the mean difference down to -74 mL (r = 0.9). Comparison on an individual basis confirmed an improvement in the estimation of absolute lung volume. CONCLUSIONS: Volumetry of ventilated lung from 3He MRI shows high correlation and good agreement with the results of pulmonary function tests.

Adult↗

(3)He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes.

MRI with hyperpolarized helium-3 ((3)He) provides high-resolution imaging of ventilated airspaces. The first aim of this (3)He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired (3)He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/alpha = 11 ms/4.2 ms/<10 degrees ). Known amounts of (3)He were inhaled from a microprocessor-controlled delivery device and imaged during single breath-holds. Images were evaluated visually, and scored using a prospectively defined 'defect-index'. Signal-to-noise ratio of the images were correlated with localization, (3)He volumes and static lung volumes. Due to poor image quality studies of two smokers were not eligible for the evaluation. Smokers differed from non-smokers in total number and size of defects: the 'defect-index' of smokers ranged between 0.8 and 6.0 (median = 1.1), that of non-smokers between 0.1 and 0.8 (median = 0.4). Intraindividually, an anteroposterior gradient of signal-to-noise ratio was apparent. Signal-to-noise ratio correlated with the estimated amount of hyperpolarization administered (r = 0. 77), but not with static lung volumes. We conclude that (3)He MRI is a sensitive measure to detect regional abnormalities in the distribution of ventilation in clinically healthy persons with normal pulmonary function tests.

Adult↗

Flip angle considerations in (3)helium-MRI.

3Helium-MRI ((3)He-MRI) can be used for analysis of lung function, e. g. dynamic imaging of ventilation and gas diffusion within the lung, assessment of intrapulmonary oxygen concentrations and their time course. During imaging, the irreversible signal loss due to depolarizing radio frequency excitations can be described using the flip angle (FA) alpha. This parameter has to be quantified in order to account for it during quantitative assessment of the (3)helium signal intensity and its temporal development. This technical report reviews two different methods to determine alpha. Limitations and possible error sources of each method are discussed.

Computer Simulation↗

(3)he-MRI-based measurements of intrapulmonary p(O2) and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations.

We applied a recently developed method of following the time course of the intrapulmonary oxygen partial pressure p(O2)(t) during apnea by (3)He MRI to healthy volunteers. Using two imaging series with different interscan times during two breathholds (double acquisition technique), relaxation of (3)He due to paramagnetic oxygen and depolarization by RF pulses were discriminated. In all four subjects, the temporal evolution of p(O2) was found to be linear, and was described by an initial partial pressure p(0) and a decrease rate R. Also, regional differences of both p(0) and R were observed. A correlation between p(0) and R was apparent. Finally, we discuss limitations of the double acquisition approach.

Adult↗

[Ultrafast MRI of lung ventilation using hyperpolarized helium-3].

OBJECTIVE: Assessment of the temporal and spatial dynamics of hyperpolarized Helium-3 (3He) distribution in the lung with ultrafast gradient-echo magnetic-resonance imaging. MATERIAL AND METHODS: Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE = 3.3 ms/1.3 ms (slice thickness, 40 mm) and TR/TE = 2.0 ms/0.7 ms (without slice selection). A series of 80 or 160 projection images was obtained with 210 ms or 130 ms temporal resolution, respectively. Imaging was performed during several respiratory cycles after application of a single bolus of 300 mL hyperpolarized 3He. Measurements were performed in six healthy volunteers (spontaneous breathing). RESULTS: Different phases of in- and expiration could be visualized. During the course of consecutive respiratory cycles the 3He signal decreased due to dilution of 3He in residual alveolar gas and by inspired air, relaxation due to oxygen and the RF pulses, and due to Helium-3 washout. The signal of a single bolus of 3He was detected in the lung for up to four respiratory cycles. Anatomical structures were better visualized on slice selective images than on images without slice selection. CONCLUSION: Distribution of inspired 3He within the tracheobronchial tree and alveolar space and its washout can be visualized by ultrafast imaging of a single bolus of hyperpolarized 3He gas. This method may allow for regional analysis of lung function with temporal and spatial resolution superior to conventional methods.

Helium↗

[19F-MRT of pulmonary ventilation in the breath-hold technic using SF6 gas].

OBJECTIVE: Development of a method to analyze lung ventilation by 19F-magnetic resonance imaging (MRI) of inspired SF6 gas during breath hold. MATERIAL AND METHODS: Measurements were performed with a Siemens Magnetom Vision 1.5 T scanner using the conventional gradient overdrive. Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE/alpha = 1.4 ms/0.48 ms/40 degrees without slice selection. With NEX = 200 averages and MA = 32 x 64 raw data matrix, the acquisition time was 9 s/image. Higher spatial resolution of 4.7 x 6.3 x 15 mm3 was obtained with a three-dimensional pulse sequence (TR/TE/alpha = 1.6 ms/0.48 ms/65 degrees, NEX = 20) running for 49 s. Measurements wer performed in three anesthetized and ventilated pigs (18 kg). RESULTS: A nearly linear relation between SF6 concentration and 19F signal intensity was observed. The signal-to-noise ratio in images obtained without slice selection was 30.9, with slice selection it was 14.9. No differences between SF6 distribution to both lungs were observed in the animals. CONCLUSION: Breath-hold MRI of SF6 gas distribution in the lung was demonstrated for the first time. The low spin-density was compensated for by highly repetitive signal averaging. Breath-hold 19F-MR imaging of ventilated airspaces to assess SF6 distribution in the human lung appears to be an interesting new method, which can be implemented with little technical efforts, and does not rely on radioactive isotopes.

Animals↗

Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI.

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional input parameters. The time course of p(O(2)) during short periods of breathholding is found to be linear in a pig as well as in a human volunteer. We also measured the wall relaxation time in the lung and deduced a lower limit of 4.3 min.

Adult↗