PubMed Health⌕ Search

Biomedical subjects

K Marten

Publications and source records attributed to K Marten.

At least 19 recordsLinked to original sources

Suspected and incidental pulmonary embolism on multidetector-row CT: analysis of technical and morphological factors influencing the diagnosis in a cross-sectional cancer centre patient cohort.

AIM: To assess technical and computed tomography (CT) predictors of true-positive (TP) and false-negative (FN) radiological diagnoses in a retrospective patient cohort with pulmonary embolism (PE) in the setting of a cancer centre. MATERIALS AND METHODS: Two thousand, four hundred and twelve consecutive chest multidetector-row CT images from 1869 patients were reviewed for presence of PE. CT protocols and TP and FN radiological reports were determined and the clinical files reviewed for suspicion of PE. The severity of PE was assessed by an arterial obstruction index. Ancillary pulmonary findings were scored qualitatively and on a lobar basis. Statistical tests included analysis of variance and univariate and multivariate logistic regressions. RESULTS: Ninety-one out of a total of 111 PE-positive images were included. Thirty-five patients had clinically suspected PE; 56 were not suspected of having PE. Forty-eight patients had TP diagnoses; 43 (39 of whom were not suspected of having PE) had FN radiological diagnoses. FN diagnoses were most frequent in oesophageal (17/19; 89.5%) and standard chest CT (19/35; 54.3%). Pulmonary CT angiography was associated with TP diagnosis (p<0.0001), whereas oesophageal CT was associated with FN diagnosis (p=0.001). Artefacts and arterial attenuation did not influence PE detection (p=0.017 and 0.066 for artefacts and arterial attenuation, respectively). However, the arterial obstruction index strongly predicted PE diagnosis (p=0.001). This was confirmed on multivariate analysis (p=0.041, 0.027 and 0.020 for pulmonary CT angiography, oesophageal protocols and arterial obstruction index, respectively). When stratified for clinically unsuspected cases, the arterial obstruction index remained the only predictor of PE diagnosis (p=0.009). CONCLUSION: Predictors of PE diagnosis were PE severity and technical factors; the latter were linked to clinical suspicion of PE. Arterial enhancement appears unlikely to contribute to missed diagnoses, if judged adequate for diagnosis of PE, and ancillary chest findings are unlikely to improve embolus detection.

Adult↗

[Acute pulmonary embolism: prediction of cor pulmonale and short-term patient survival from assessment of cardiac dimensions in routine multidetector-row CT].

PURPOSE: Evaluation of the prognostic value of morphological cardiac parameters in patients with suspected and incidental acute pulmonary embolism (PE) using multidetector-row chest CT (MSCT). MATERIALS AND METHODS: 2335 consecutive MSCT scans were evaluated for the presence of PE. The arterial enhancement and analysability of pulmonary arteries and the heart were assessed as parameters of the scan quality. The diastolic right and left ventricular short axes (RV (D), LV (D)) and the interventricular septal deviation (ISD) were measured in all PE-positive patients and the echocardiography reports were reviewed. The clinical data assessment included cardio-respiratory and other co-morbidities, systemic anticoagulant therapy (ACT), and the 30-day outcome. Predictors of acute cor pulmonale and the short-term outcome were calculated by univariate and multivariate logistic regressions including odds ratios (OR) and ROC analyses using positive (PPV) and negative predictive values (NPV). RESULTS: 90 patients with acute PE were included (36 with clinically suspected PE, 54 with incidental PE). 26 patients had cardio-respiratory co-morbidities. Four patients underwent systemic thrombolysis, 43 underwent anticoagulation in therapeutic doses, 19 underwent anticoagulation in prophylactic doses, and 24 patients did not undergo ACT. 15 of 41 patients had echocardiographic evidence of acute cor pulmonale. 8 patients died within 30 days. The RV (D) was the best independent predictor of acute cor pulmonale (p = 0,002, OR = 9.16, PPV = 0.68, NPV = 1 at 4.49 cm cut off) and short-term outcome (p = 0,0005, OR = 2.82, PPV = 0.23, NPV = 0.98 at 4.75 cm cut off). The RV (D)/LV (D) ratio had a PPV of 0.85 for cor pulmonale. CONCLUSION: The RV (D) and RV (D)/LV (D) ratio were suitable for identifying patients with acute cor pulmonale and for benign short-term prognosis. Further studies should prospectively address the combined use of CT-morphological and clinical parameters for the prediction of patient outcome.

Adult↗

Lateralized visual behavior in bottlenose dolphins (Tursiops truncatus) performing audio-visual tasks: the right visual field advantage.

Analyzing cerebral asymmetries in various species helps in understanding brain organization. The left and right sides of the brain (lateralization) are involved in different cognitive and sensory functions. This study focuses on dolphin visual lateralization as expressed by spontaneous eye preference when performing a complex cognitive task; we examine lateralization when processing different visual stimuli displayed on an underwater touch-screen (two-dimensional figures, three-dimensional figures and dolphin/human video sequences). Three female bottlenose dolphins (Tursiops truncatus) were submitted to a 2-, 3- or 4-, choice visual/auditory discrimination problem, without any food reward: the subjects had to correctly match visual and acoustic stimuli together. In order to visualize and to touch the underwater target, the dolphins had to come close to the touch-screen and to position themselves using monocular vision (left or right eye) and/or binocular naso-ventral vision. The results showed an ability to associate simple visual forms and auditory information using an underwater touch-screen. Moreover, the subjects showed a spontaneous tendency to use monocular vision. Contrary to previous findings, our results did not clearly demonstrate right eye preference in spontaneous choice. However, the individuals' scores of correct answers were correlated with right eye vision, demonstrating the advantage of this visual field in visual information processing and suggesting a left hemispheric dominance. We also demonstrated that the nature of the presented visual stimulus does not seem to have any influence on the animals' monocular vision choice.

Acoustic Stimulation↗

Electrocardiographic assistance in multidetector CT of thoracic disorders.

ECG-synchronized multislice spiral CT (MSCT) allows a significant reduction of cardiac motion artefacts and as a result a virtually artefact-free display of intrathoracic structures. With their advantages in imaging geometry and continuous spiral image acquisition multislice CT scanners provide superior image quality and spatial resolution in these patients. Possible clinical applications for ECG assistance in MSCT include CT angiography of the coronary arteries, functional cardiac CT imaging and imaging of the cardiac valves, CT angiography of the aorta or pulmonary vascular tree as well as ECG-gated imaging of the lung parenchyma. Prospective ECG triggering and retrospectively ECG-gated image reconstruction comprise the technical corsage for reduction of pulsation artefacts in cardiac and other thoracic CT applications. In addition the development of time-optimised reconstruction algorithms for retrospective cardiac gating in 8- and 16 slice spiral CT scanners have enabled further improvements in temporal resolution. This overview describes the technique, its clinical indications and the merits of electrocardiographic assistance in MSCT of chest disorders.

Calcinosis↗

Computer-aided detection of pulmonary nodules: influence of nodule characteristics on detection performance.

AIM: To evaluate prospectively the influence of pulmonary nodule characteristics on detection performances of a computer-aided diagnosis (CAD) tool and experienced chest radiologists using multislice CT (MSCT). MATERIALS AND METHODS: MSCT scans of 20 consecutive patients were evaluated by a CAD system and two independent chest radiologists for presence of pulmonary nodules. Nodule size, position, margin, matrix characteristics, vascular and pleural attachments and reader confidence were recorded and data compared with an independent standard of reference. Statistical analysis for predictors influencing nodule detection or reader performance included chi-squared, retrograde stepwise conditional logistic regression with odds ratios and nodule detection proportion estimates (DPE), and ROC analysis. RESULTS: For 135 nodules, detection rates for CAD and readers were 76.3, 52.6 and 52.6%, respectively; false-positive rates were 0.55, 0.25 and 0.15 per examination, respectively. In consensus with CAD the reader detection rate increased to 93.3%, and the false-positive rate dropped to 0.1/scan. DPEs for nodules < or = 5 mm were significantly higher for ICAD than for the readers (p < 0.05). Absence of vascular attachment was the only significant predictor of nodule detection by CAD (p = 0.0006-0.008). There were no predictors of nodule detection for reader consensus with CAD. In contrast, vascular attachment predicted nodule detection by the readers (p = 0.0001-0.003). Reader sensitivity was higher for nodules with vascular attachment than for unattached nodules (sensitivities 0.768 and 0.369; 95% confidence intervals = 0.651-0.861 and 0.253-0.498, respectively). CONCLUSION: CAD increases nodule detection rates, decreases false-positive rates and compensates for deficient reader performance in detection of smallest lesions and of nodules without vascular attachment.

Adult↗

[Computer-aided diagnosis and volumetry of pulmonary nodules: current concepts and future perspectives].

For computer-aided detection (CAD) and volumetry of small pulmonary nodules, a number of algorithms have been developed for multislice CT data sets in recent years, with the goal of improving the diagnostic work-up and the follow-up of findings. Recent data show that the detection of small lesions may improve with CAD, suggesting that especially experienced readers may benefit from using CAD systems. This has lead to the recommendation of CAD as a replacement of the second reader in clinical practice. Furthermore, computer-aided volumetry of pulmonary nodules allows a precise determination of nodular growth rates as a prerequisite for a better classification of nodules as benign or malignant. In this article, we review recent developments of CAD and volumetry tools for pulmonary nodules, and address open questions regarding the use of these software tools in clinical routine.

Diagnosis, Computer-Assisted↗

Case report: Fatal acute exacerbation of usual interstitial pneumonia in ulcerative colitis.

Pulmonary involvement in ulcerative colitis may manifest as a variety of disorders. Ulcerative colitis-related interstitial lung disease is exceedingly rare and has been reported to be steroid-responsive. We describe the first case of a patient with acute exacerbation of ulcerative colitis-induced usual interstitial pneumonia, who did not respond to corticosteroid therapy and died 12 weeks after the onset of pulmonary symptoms. Early recognition of pulmonary disease in patients with ulcerative colitis is necessary to initiate further diagnostic work-up and may aid treatment decisions.

Acute Disease↗

[Flat-panel detector-based computed tomography: accuracy of experimental growth rate assessment in pulmonary nodules].

PURPOSE: To determine the performance of an a-Si/CsJ flat-panel detector-based volumetric computed tomography (VCT) prototype in volumetry of synthetic nodules in a pulmonary phantom, and to assess VCT accuracy in the assessment of hypothetic tumor growth rates based on predefined tumor doubling times. METHODS: The true volumes of 50 synthetic nodules (diameter range = 1.36 - 5.34 mm) were determined and VCT volumetry was performed before and after isovolumetric deformation of the nodules. The percent measurement error (PMF) was calculated as the percent difference of the measured from the true volume. Based on the PMF, the minimum interval between two scans was determined that would be needed to depict tumor growth corresponding to the minimum number of required follow-up days (FUDs). Based on predefined tumor doubling times (VDT) FUDs were determined before and after nodule deformation. RESULTS: Measured volumes of undeformed and deformed nodules of 0.99 - 20.05 mm (3) differed significantly from corresponding true volumes (p = 0.002 - 0.004). The PMFs of these nodules significantly exceeded the values measured in larger nodules (p = 0.0001 - 0.0029). In addition, PMFs were significantly lower before than after deformation (1.33 - 7.14 % and 0.61 - 11.09 %, respectively; p = 0.002). For theoretical VDTs of 177 and 396 days, the calculated FUDs for detection of tumor growth were 19.1 and 42.7 days before deformation, and 30.2 and 67.6 days after deformation for nodules < 2 mm, respectively. CONCLUSION: VCT allows for accurate volumetry of smallest pulmonary nodules and may become a valuable clinical tool for depiction of tumor growth of even small lesions within very short scan intervals.

Data Interpretation, Statistical↗

The CT halo: a new sign in active pulmonary sarcoidosis.

A case of pulmonary sarcoidosis is presented characterized by multiple coalescent nodules and peripheral ground glass halos, which were fully reversible under repeat systemic glucocorticoid treatment. The differential diagnostic aspects of the pulmonary CT halo sign and its potential for indicating active reversible disease in patients with sarcoidosis is discussed.

Adult↗

Pulmonary haemangiosarcoma with main pulmonary artery thrombosis imitating subacute pulmonary embolism with infarction.

We report a patient with subacute pulmonary hypertension caused by unilateral massive pulmonary artery thrombosis due to a pulmonary haemangiosarcoma of the lower lobe with pulmonary arterial and bronchial invasion. The patient was misdiagnosed as having subacute pulmonary embolism and underwent thrombolytic therapy complicated by severe pulmonary haemorrhage. The imaging features of pulmonary artery thrombosis with underlying malignancy and their differential diagnosis are discussed.

Aged↗

ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism.

AIM: The purpose of this study was to determine the feasibility of echocardiogram (ECG)-gated multi-slice CT angiography (MCTA) in patients with clinical suspicion of acute venous thromboembolism (VTE), to investigate the effect of ECG-gating on cardiac motion artefacts, and to determine the diagnostic reader agreement of ECG-gated MCTA in comparison with conventional MCTA. MATERIALS AND METHODS: Forty-eight consecutive patients were prospectively enrolled and randomly underwent ECG-gated (n=25, group 1) or non-ECG-gated (n=23, group 2) eight-slice pulmonary MCTA. Image data were evaluated by three independent chest radiologists with respect to the presence or absence of emboli at different arterial levels (main, lobar, segmental, and subsegmental arteries), and with regard to cardiac motion artefacts. Statistical tests used to calculate inter-observer agreement were weighted kappa statistics, extended kappa statistics and confidence indices indicating three-reader agreement accuracy. RESULTS: Twenty-seven patients (56.3%) were diagnosed to have pulmonary embolism (13 from group 1, 14 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70% in group 2 versus 13% in group 1, p=0.0001). The overall diagnostic agreement was excellent with both MCTA techniques (three-reader confidence index for all vascular territories: 0.76 and 0.84 for groups 1 and 2, respectively (extended kappa=0.69 and 0.78, respectively); three-reader confidence index for diagnosis of VTE: 0.94 and 0.85 for groups 1 and 2, respectively (extended kappa=0.91 and 0.73, respectively), weighted kappa=0.81-0.83 and 0.92-0.95 for groups 1 and 2, respectively, and did not differ significantly between the two groups. In addition there was no significant difference of inter-observer agreement in either group at any assessed pulmonary arterial level. CONCLUSION: ECG-gated pulmonary MCTA is feasible in patients with clinical suspicion of VTE. However, ECG-gated image acquisition did not influence the diagnostic reader agreement accuracy and inter-observer agreement of MCTA. Hence, it does not appear to be advantageous for the MCTA diagnosis of pulmonary embolism.

Acute Disease↗

[The contribution of different postprocessing methods for multislice spiral CT in acute pulmonary embolism].

PURPOSE: To investigate the value of different postprocessing algorithms for multislice spiral CT (MSCT) in diagnosing acute pulmonary embolism. MATERIALS AND METHODS: Forty-eight patients with suspected pulmonary embolism prospectively underwent MSCT using an 8-slice spiral CT. Using a confidence level on a three-point scale, three radiologists reviewed 2-mm and 5-mm axial slices, 5-mm and 10-mm axial maximum intensity projections (MIP) and 2-mm coronal slices as well as interactively generated multiplanar reformatted images. A subsequent consensus reading of the primary 1.25-mm axial slices served as gold standard. ROC analysis was applied to the various vascular sections. RESULTS: The ROC analysis revealed a higher diagnostic accuracy of the 2-mm axial sections as compared to the 5-mm axial slices (Az = [0.988;0.976] vs. Az = [0.988;0.802]). Coronal and multiplanar reformations also showed excellent diagnostic accuracy (Az = [0.972;0.949] and Az = [0.997;0.951], respectively) and were significantly superior to the 5-mm axial slices through the segmental and subsegmental arteries (p=0.05). MIP showed the weakest diagnostic accuracy (Az = [0.967;0.802] for 5-mm MIP; Az = [0.879;0.781] for 10-mm MIP). CONCLUSION: Thin axial slices as well as coronal and multiplanar reformations are superior to thick axial slices in the diagnosis of acute pulmonary embolism. MIP is not suited for accurate diagnosis of pulmonary embolic disease.

Acute Disease↗

[Diagnostic performance of retrospectively ECG-gated multislice CT of acute pulmonary embolism].

AIM: This study determined the diagnostic performance of ECG-gated MSCT in comparison with conventional MSCT. MATERIALS AND METHODS: Forty-five consecutive patients prospectively underwent ECG-gated (group 1, n = 23) or non-ECG-gated (group 2, n = 22) 8-slice MSCT of the pulmonary arteries. Image data were interactively evaluated by three independent chest radiologists with respect to the presence of emboli at different arterial levels, and with regard to cardiac motion artefacts. Consensus reading by two experienced chest radiologists served as diagnostic gold standard. ROC analysis was carried out for the different vascular sections. RESULTS: Twenty-five patients (56 %) were diagnosed to have pulmonary embolism (13 from group 1, 12 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70 % in group 2 versus 13 % in group 1, p < 0.05). There was no significant difference between the two groups in the overall sensitivities (0.92 vs. 0.95) and specificities (0.92 vs. 0.98) or in sensitivities and specificities at any assessed pulmonary arterial level. CONCLUSION: ECG-gated MSCT pulmonary angiography does not significantly influence the diagnostic performance of MSCT in these patients. Therefore no recommendation for routine clinical practice can be given.

Adolescent↗

Average glandular dose with amorphous silicon full-field digital mammography - Clinical results.

PURPOSE: Determination of average glandular dose with a full-field digital mammography system using a flat-panel X-ray detector based on amorphous silicon technology for a large group of patients. MATERIAL AND METHODS: The patient group includes women who were examined in a 4-month period with the digital mammographic system Senographe 2000D. The number of women was 591 and the number of exposures was 1116; only cranio-caudal projections were considered. Various quantities, including entrance surface air kerma, tube loading, and compressed breast thickness, were determined during actual mammography. Average glandular dose was determined using conversion factors g for standard breast composition. RESULTS: The mean average glandular dose was 1.51 mGy (0.66 - 4.05 mGy) for a single view. The mean compressed breast thickness was 55.7 mm. The mean age of patients was 55 years (34 - 81 years). CONCLUSION: The results demonstrate that full-field digital mammography with a flat-panel detector based on amorphous silicon needs about 25 % less dose in comparison with conventional screen-film mammography.

Adult↗

Mirror image processing in three marine mammal species: killer whales (Orcinus orca), false killer whales (Pseudorca crassidens) and California sea lions (Zalophus californianus).

Dolphins (Tursiops truncatus) and their relatives might be expected to show mirror-induced contingency checking, a prerequisite to self-recognition, because of their high brain development, their complex social life and their demonstrated abilities in bodily imitation. A study of killer whales'(Orcinus orca) behaviour in front of a mirror is presented, including a mark test. Shorter investigations of mirror behaviour are also described in false killer whales (Pseudorca crassidens) and California sea lions (Zalophus californianus). Contingency checking was present in killer whales and possibly also in false killer whales, but no clear contingency checking was observed in sea lions. The mark test on killer whales suggested that the marked animal anticipated that its image would look different. This study shows that killer whales and false killer whales, like bottlenose dolphins, appear to possess the cognitive abilities required for self-recognition.

Journal Article↗

Efficient radiological assessment of the internal snapping hip syndrome.

The aim of this study was to evaluate the diagnostic value/significance of various imaging techniques for demonstrating the underlying causative pathology of clinically suspected internal snapping hip syndrome. We intended to define the most efficient diagnostic imaging algorithm that leads to a specific definite therapy for this rare hip disorder. The imaging studies of 54 patients (43 women, 11 men, average age 58 years) with the clinical suspicion of internal snapping hip syndrome were compared for their diagnostic value/significance for finding the underlying pathology. Radiological workup included plain radiographs of the pelvis and hip joints (n=54), ultrasound (US) of the hip joints (n=29), computed tomography (CT) of the pelvis and proximal femur (n=17), and magnetic resonance imaging (MRI) of the pelvis/hip joint (n=21). In order to establish an efficient diagnostic algorithm we compared the diagnostic value of each imaging technique alone and in combination with the other methods. The underlying causative pathology could be established in 37% of patients (n=20) by the use of conventional radiographs alone and in 46% of the patients (n=25) by US alone, and in combination in 83% of the patients (n=45). By adding CT to the radiological workup, we established final diagnosis in 88% (in combination with X-ray; n=15/17) and 94% (together with X-ray and US; n=16/17) of the patients. Whenever MR imaging was used a causative pathology was found in all patients (100%; n=21). The most efficient radiological algorithm in the assessment of patients with internal snapping hip syndrome is the combination of plain radiography and US. MR imaging can be retained for unresolved and difficult cases.

Adult↗