Voltage dependence of ICD lead polarization and the effect of iridium oxide coating.

Nonthoracotomy leads (NTLs) with an iridium oxide (IROX) coating exhibit lower defibrillation thresholds (DFTs) than uncoated NTLs. We tested whether adding an IROX coating to an active pectoral can would influence defibrillation efficacy. However, the primary purpose of this study was to examine the impedance changes that occur at different voltages for uncoated titanium NTLs and identical NTLs with an IROX coating. We studied anesthetized pigs with an NTL placed in the right ventricle and coupled this to an active pectoral can. Biphasic waveform DFTs were obtained for the four NTLs and can combinations: uncoated NTL and uncoated can, uncoated NTL and IROX can, IROX NTL and uncoated can, and IROX NTL and IROX can. The respective energy DFTs were: 23.6 +/- 6.9, 24.1 +/- 6.7, 21.3 +/- 6.0, and 21.4 +/- 7.0 J. The IROX NTL DFTs were significantly lower (P < 0.05) than the uncoated NTL DFTs (either can), confirming our previous study. We then used a low tilt monophasic waveform to assess impedance changes. The impedance rise for each NTL/can combination was measured at 50, 100, 300, and 700 V. Comparisons of impedance changes between voltage levels showed that the impedance rise was inversely related to voltage and was greatest with uncoated NTLs. The IROX coating of the NTL reduced the impedance rise at all shock voltages, but was particularly beneficial at the lower voltages. No advantage was seen when the pectoral can was coated with IROX regardless of which NTL was used. Our results suggest that low voltage applications, such as atrial defibrillation, would benefit most from the IROX-coated NTL, and further studies are warranted in this area.

Animals↗

Iridium oxide-coated defibrillation electrode: reduced shock polarization and improved defibrillation efficacy.

BACKGROUND: Transvenous implantable cardioverter-defibrillator (ICD) leads are designed to deliver electric shocks to the heart for termination of ventricular dysrhythmias. However, the efficiency of different lead materials has not been well studied. This study compares an ICD lead coated with iridium oxide (IROX), a material that reduces shock-induced polarization, with an otherwise identical, uncoated lead. METHODS AND RESULTS: The defibrillation threshold (DFT) was determined in 13 swine with both IROX-coated and uncoated ICD leads paired with an uncoated "can" electrode. The leads were exchanged through a Teflon sheath to reproduce the intracardiac position. The delivered energy DFT of the IROX-coated lead was 15.9+/-5.4 J and was significantly lower than the delivered energy DFT of the uncoated lead (19.1+/-5.1 J; P<.006). The initial lead impedance was equivalent in both leads (IROX, 41.7+/-5.8 omega; uncoated, 41.3+/-4.7 omega; P=NS) at DFT. However, the impedance rose by 7.3+/-2.0 omega during the first phase and by 3.7+/-2 omega during the second phase with the uncoated lead, whereas the corresponding impedance change was 1.0+/-0.3 omega during phase 1 and 1.6+/-0.5 omega during phase 2 (P<.01 each phase) when the IROX-coated lead was used. CONCLUSIONS: This study shows that an IROX coating of this lead system significantly lowers the DFT energy in the swine model. The blunting of the impedance rise by the IROX coating that is seen is consistent with a reduction in electrode polarization.

Animals↗

Effects of 2,3-butanedione monoxime on atrial-atrioventricular nodal conduction in isolated rabbit heart.

INTRODUCTION: 2,3-Butanedione monoxime (BDM) has been found to reversibly block cardiac contraction, without blocking electrical conduction. This study characterizes the dose-dependent effects of BDM on the conduction through the atrioventricular node (AVN) of rabbit heart. METHODS AND RESULTS: Thirteen isolated atrial-AVN preparations were used in control, during and after exposure to 5, 10, and 20 mM BDM. Anterograde and retrograde pacing protocols were used to obtain the Wenckebach cycle length, effective and functional refractory periods of the AVN, index of AVN conduction delay (the area under the AVN conduction curve), as well as index of intra-atrial conduction delay between the AVN inputs. Compared to control, 5 and 10 mM BDM produced either shortening or no effect on all of the above parameters except a slight (6% and 14%, respectively) increase in the intra-atrial delay. At 20 mM, BDM produced a further increase in the intra-atrial delay (up to 50%) as well as in the retrograde AVN conduction delay (up to 16%), while the characteristics of the anterograde conduction were still improved. The effects of perfusion with BDM on these parameters were reversible after washout. CONCLUSIONS: Aside from its known effect as an electromechanical uncoupler, BDM reversibly altered some of the electrical responses of the AVN. Most of these alterations, however, did not impede but rather improved AVN conduction. Since a dose of 10 mM is sufficient to fully eliminate undesirable motion, BDM should be considered a safe and valuable tool in AVN studies in vitro requiring a mechanically quiescent preparation.

Action Potentials↗

Relation of the atrial input sites to the dual atrioventricular nodal pathways: crossing of conduction curves generated with posterior and anterior pacing.

INTRODUCTION: The usually accepted definition of the dual pathway electrophysiology requires the presence of conduction curves with a discontinuity ("jump"). However, AV nodal reentrant tachycardia has been observed in patients with "smooth" conduction curves, whereas discontinuity of the conduction curve does not guarantee induction of stable reentry. We hypothesize that the duality of AV nodal conduction can be revealed by careful choice of stimulation sites during the generation of AV nodal conduction curves. METHODS AND RESULTS: In 21 rabbit heart atrial-AV nodal preparations, programmed electrical stimulation with S1-S2-S3 pacing protocol was applied either posteriorly at the crista terminalis input site (CrT) or anteriorly at the lower interatrial septum input site (IAS), or (in 8 preparations with surgically divided input sites) at both. We found that in intact preparations with "smooth" conduction curves, pacing at long coupling intervals produced shorter AV nodal conduction times from the IAS (56 +/- 9.8 msec vs 69 +/- 10.1 msec; P < 0.01). At short coupling intervals, in contrast, shorter conduction times were obtained from the CrT (173 +/- 21.8 msec vs 188 +/- 22.8 msec; P < 0.01). This resulted in a characteristic crossing of the superimposed IAS and CrT conduction curves. After division of the inputs, the IAS site had rapid conduction to the His bundle but a longer refractory period, whereas the CrT site had long conduction times and shorter refractory periods. Wavefronts entering the AV node from these two inputs can summate, resulting in improved conduction. CONCLUSION: Pacing protocols designed to accentuate the asymmetry between the AV nodal inputs can help to reveal the functional difference between the dual pathways and thus to better assess the properties of AV nodal conduction.

Animals↗

Mechanism of atrioventricular nodal facilitation in rabbit heart: role of proximal AV node.

The phenomenon of atrioventricular (AV) nodal "facilitation," described in traditional "black box"-functional studies, implies enhanced AV nodal dromotropic function. We investigated the role of atrial prematurities in the modulation of the nodal cellular responses in the mechanism of AV nodal facilitation. Atrial and His (H) bundle electrograms and microelectrode recordings from proximal AV nodal cells were analyzed in 15 superfused rabbit AV node preparations. The pacing protocol consisted of 30 basic beats (S1; coupling interval S1-S1 = 300 ms) followed by a facilitating prematurity (S2; coupling intervals S1-S2 of 300, 200, 150, and 130 ms) followed by the test beat (S3; coupling interval S2-S3 scanned in 5-ms steps). Conduction curves (S2-H2 vs. S1-S2, S3-H3 vs. S2-S3, and S3-H3 vs. H2-S3) were constructed. Facilitation (i.e., shortening of S3-H3 when S1-S2 was shortened) was demonstrated in all preparations using the H2-S3 (P < 0.001) but not the S2-S3 format. Microelectrode recordings revealed a causal relationship between the improved proximal AV nodal cellular responses in facilitation and the prolonged S2-S3 interval. There was no evidence for enhanced nodal dromotropic function directly resulting from the introduction of the facilitating beats. Thus facilitation is based on inherent cycle-length-dependent properties of the AV node during application of a complex pacing protocol and primarily reflects the uncontrolled modulation of the proximal cellular response.

Animals↗

Smaller capacitors improve the biphasic waveform.

INTRODUCTION: Current implantable cardioverter defibrillators (ICDs) use relatively large capacitance values. Theoretical considerations suggest, however, that improved defibrillation energy requirements may be obtained with smaller capacitance values. METHODS AND RESULTS: We compared the energy requirement for defibrillation in a porcine model using a biphasic waveform generated from two capacitance values of 140 microF and 85 microF. Phase 1 reversal of the shock waveform occurred at 65% tilt. Phase 2 pulse width was equal to phase 1. Shocks were delivered through epicardial patch electrodes after 10 seconds of induced ventricular fibrillation. The defibrillation threshold (DFT) was determined by a "down-up" technique requiring three reversals of defibrillation success or failure. The DFT was defined as the average of the values obtained with all trials starting from the successful shock prior to the first failure to defibrillate to the last successful defibrillation. In eight experiments, the measured parameters at DFT were as follows. The average stored and delivered DFT energies for the 85 microF capacitor were 6.1 +/- 2.1 and 6.0 +/- 2.0 J, respectively, compared to 7.5 +/- 1.3 and 7.4 +/- 1.3 J for the 140 microF capacitor (P < 0.04). The phase 1 pulse widths were significantly shorter for the 85 microF capacitor (5.1 +/- 0.8 msec vs 9.2 +/- 1.3 msec) and the impedances were lower (54.4 +/- 5.8 omega vs 59.9 +/- 6.3 omega). The mean leading edge voltage was trending higher for the 85 microF capacitor, but this difference did not reach statistical significance (374 +/- 63 V vs 326 +/- 30 V; P = 0.055). CONCLUSION: Smaller capacitance values do result in lower energy requirements for the biphasic waveform, at a possibly higher leading edge voltage and a much shorter pulse width. Smaller capacitance values could represent a significant enhancement of well-established benefits demonstrated with the biphasic waveform.

Animals↗

Model studies of extracellular electrograms arising from an excitation wave propagating in a thin layer.

Extracellular potentials were calculated for a wave of activation propagating through a thin layer of tissue. Sources were represented on the basis of the bidomain model, with the observation point at the tissue surface. Calculated potentials were found to be insensitive to the length of the wavefront if it passed under the recording electrode provided its length exceeded 1 mm, but to decrease rapidly when the wave passed to a side of the electrode. Contributions of source regions with a lateral displacement from the electrode greater than about 0.3 mm were substantially diminished. The effects of the thickness of the layer and velocity of propagation on amplitude was investigated.

Action Potentials↗