PubMed Health⌕ Search

Biomedical subjects

K N Yu

Publications and source records attributed to K N Yu.

At least 55 records · Page 3Linked to original sources

Bronchial Rn dose survey for residences.

The bronchial dosimeter for Rn progeny proposed by Yu and Guan in 1998 was employed to survey the bronchial dose from Rn progeny in 30 residences in Hong Kong. An average bronchial deposition fraction of Rn progeny was obtained as 0.0334, which gave an average dose conversion factor (DCF) of 8.5 mSv WLM-1. The mean values of potential alpha energy concentration (PAEC) deposited in the tracheobronchial region (PAECT-B), total PAEC in air (PAECT), annual effective dose (E), concentration of Rn gas (RC) and annual dose conversion factor (ADCF) for all the residential sites combined were 0.11 +/- 0.05, 3.1 +/- 1.4 mWL, 1.2 +/- 0.5 mSv yr-1, 23 +/- 10 Bq m-3 and 0.055 +/- 0.020 (mSv yr-1 per Bqm-3), respectively, with air-conditioned sites (AC sites) and non-AC sites having significantly different mean ADCF values. The indoor relative humidity affected PAECT and RC with high confidence levels (> 95%).

Air Pollutants, Radioactive↗

Radon progeny dose conversion coefficients for Chinese males and females.

The airway dimensions for Caucasian males have been scaled by multiplying by factors 0.95 and 0.88 to give those for Chinese males and females, respectively. Employing the most recent data on physical and biological parameters, the radiation doses to the basal and secretory cells due to alpha particles from 218Po and 214Po, homogeneously distributed in the mucous layer, have been calculated. The emission of alpha particles has been simulated by a Monte Carlo method. For both basal and secretory cells, the dose conversion coefficients (DCCs) for physical conditions of sleep, rest, light and heavy exercise, have been obtained for Chinese males and females for unattached progeny, and for attached progeny of diameters 0.02, 0.15, 0.25, 0.30 and 0.50 micron. For basal cells, the coefficients lie in the range 0.69-6.82 mGy/(Js/m3) or 8.7-86 mGy/WLM for unattached progeny and in the range 0.045-1.98 mGy/(Js/m3) or 0.57-25 mGy/WLM for attached progeny. The corresponding ranges for Caucasian males are 1.27-8.81 mGy/(Js/m3) or 16-111 mGy/WLM-1 and 0.05-2.30 mGy/(Js/m3) or 0.64-29 mGy/WLM. For secretory cells, the coefficients lie in the range 0.095-16.82 mGy/(Js/m3) (1.2-212 mGy/WLM) for unattached progeny and in the range 0.095-6.67 mGy/(Js/m3) (1.2-84 mGy/WLM) for attached progeny. The corresponding ranges for Caucasian males are 0.34-21.51 mGy/(Js/m3) (4.3-271 mGy/WLM) and 0.1-7.78 mGy/(Js/m3) (1.3-98 mGy/WLM). The overall DCCs calculated for a typical home environment are 0.59 and 0.52 mSv/(Js/m3) (7.4 and 6.5 mSv/WLM) for Chinese males and females, respectively, which are 80 and 70% of the value, 0.73 mSv/(Js/m3) (9.2 mSv/WLM), for Caucasian males.

Activities of Daily Living↗

Dose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations.

The accuracy of the dose planning system (Leksell GammaPlan), used in Gamma Knife (type B) radiosurgery at extreme irradiation depths, was verified using the Monte Carlo technique. EGS4 Monte Carlo calculations were employed to calculate the dose distribution along the x, y and z axes for an irradiation relatively shallow in a spherical bony cavity water phantom. Two different sizes of the collimator helmets, 8 and 18 mm, of the Leksell Gamma Knife Unit were studied. The results of GammaPlan showed good consistency with the Monte Carlo results. Furthermore, small dose enhancements were observed in the skull bone where accurate dose measurements are difficult due to the presence of the air-phantom interface. Therefore, the results of this project can promote confidence to all Gamma Knife centres in the world when using the Leksell GammaPlan.

Humans↗

Theoretical foundation for a simple method for simultaneous measurements of the unattached fraction and activity median diameter of attached radon progeny.

Calculation of lung dose from established lung dosimetry models requires use of the unattached fraction of potential alpha energy concentration (PAEC) of radon progeny and the activity median diameter (AMD) of attached radon progeny, in addition to the total PAEC. In the present work, for indoor environments without the nucleation mode of aerosols, a method based on the wire screen penetration theory using two wire screens and a filter is proposed for simultaneous measurements of these two parameters. It is shown that the traditional wire screen method can overestimate or sometimes underestimate the unattached fraction, depending on the properties of the wire screen and the true unattached fraction. The present method eliminates such uncertainties.

Alpha Particles↗

Bronchial dosimeter for radon progeny.

A true bronchial dosimeter has been designed, consisting of four 400-mesh wire screens and a filter paper. With a face velocity of 3.3 cm s(-1) for home exposure and 4.6 cm s(-1) for mine exposure, the deposition pattern on the wire screens were found to satisfactorily match the variation of the dose conversion factor (in units of mSv WL M(-1)) with the size of radon progeny from 1 to 1000 nm. In this way, the bronchial dosimeter directly gives bronchial dose from the alpha counts recorded on the wire-screens and the filter paper. Calculations of the dose conversion coefficient (DCC) using the proposed bronchial dosimeter and the lung dosimetric model were performed for typical aerosol characteristics. Values obtained from the bronchial dosimeter yielded overestimates of the DCC by 11.1% and 2.4% for typical home and mine conditions, respectively.

Bronchi↗

Alpha hit frequency due to radon decay products in human lung cells.

PURPOSE: To calculate the hit probabilities by alpha-particles emitted by radon progeny for basal and secretory cell nuclei in the epithelium of the human tracheobronchial tree. MATERIALS AND METHODS: The equilibrium activities on the surface of airway tubes were calculated using the ICRP66 model. The stopping-power and ranges of alpha-particles in tissue were adopted from ICRU49. A semi-analytical method for determining the alpha-particle fluence rate in tissue was applied. The distributions of secretory and basal cells throughout the tracheobronchial tree were as given by Mercer et al. (1991). RESULTS: The probability to hit basal cell nuclei is three-to-four times smaller than for secretory cell nuclei in the bronchial region (BB). However, the total number of traversed basal cell nuclei is greater because of the larger volume abundance of basal cells in BB. The total number of secretory cell nuclei hit in the bronchiolar region (bb) is larger than that in BB because the volume abundance of secretory cells in bb is larger than that in BB. CONCLUSIONS: Basal cells are more sensitive to alpha-radiation than secretory cells. This finding is based on the analysis of the relative number of cell hits and the relative frequencies of lung cancer induction in BB and bb.

Aerosols↗

Absorbed fraction and dose conversion coefficients of alpha particles for radon dosimetry.

The sensitivity to different relevant parameters of the absorbed fraction of alpha particles emitted from the 222Rn chain in sensitive cells of the tracheo-bronchial tree have been investigated. The structure of the airway wall given by ICRP (ICRP66) has been adopted and employed in the present calculations. The source thickness (mucous gel and sol + cilia), target layer thickness and the depth of the sensitive layers have been varied within reasonable ranges around the default values recommended by ICRP66. The results have shown that the depth of the sensitive layers is the most important parameter in calculating the absorbed fraction. In addition, dose conversion coefficients were calculated and presented along with the absorbed fractions.

Alpha Particles↗

Stereotactic dose planning system used in Leksell Gamma Knife model-B: EGS4 Monte Carlo versus GafChromic films MD-55.

The accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (model-B) radiosurgery was verified using both the GafChromic films MD-55 (improved) and the EGS4 Monte Carlo technique. The Monte Carlo technique was employed to calculate the dose distribution along the x-, y- and z-axes when a single shot with opening of all 201 sources was delivered at the centre of a simulated water phantom with a diameter of 160 mm. Collimator helmets with different size of the Gamma Knife unit were verified. Good consistency (typical discrepancy less than 2%) was obtained between the results of Monte Carlo and GammaPlan. Small discrepancies, however, were obtained by GafChromic films. Discrepancies, as great as 10% when using the 4 mm collimator helmet, at the low percentage isodose curve along the z-axis of the measurement results were probably due to the small energy dependency of the GafChromic films. Significant discrepancies were not observed along x- and y-axes because such small discrepancies were easily over-washed by other gamma beams coming from the x- and y-directions. Similar results showing the discrepancies between the GafChromic films and GammaPlan were obtained when using the 8, 14 and 18 mm collimator helmets. However, the discrepancies along the z-axis became smaller as scattering effect increased when using larger collimator sizes. We suggest that the Monte Carlo technique should also be applied in stereotactic dose planning system verification as it is an ideal and reliable computational technique.

Film Dosimetry↗

Monte Carlo calculations of LR115 detector response to 222Rn in the presence of 220Rn.

The sensitivities (in m) of bare LR115 detectors and detectors in diffusion chambers to 222Rn and 220Rn chains are calculated by the Monte Carlo method. The partial sensitivities of bare detectors to the 222Rn chain are larger than those to the 220Rn chain, which is due to the higher energies of alpha particles in the 220Rn chain and the upper energy limit for detection for the LR115 detector. However, the total sensitivities are approximately equal because 220Rn is always in equilibrium with its first progeny, which is not the case for the 222Rn chain. The total sensitivity of bare LR115 detectors to 222Rn chain depends linearly on the equilibrium factor. The overestimation in 222Rn measurements with bare detectors caused by 220Rn in air can reach 10% in normal environmental conditions. An analytical relationship between the equilibrium factor and the ratio between track densities on the bare detector and the detector enclosed in chamber is given in the last part of the paper. This ratio is also affected by 220Rn, which can disturb the determination of the equilibrium factor.

Environmental Monitoring↗

Monte Carlo calculated output factors of a Leksell Gamma Knife unit.

The Leksell Gamma Knife is a standard radiosurgical tool for treating brain lesions by directing beams of gamma radiation to a specific region. The diameter of the gamma beams is confined by collimator systems and available collimator sizes are 4, 8, 14 and 18 mm. The reduction in dose rate for each collimator helmet is called the output factor (OPF). Experimental determination of OPFs is difficult due to the extremely narrow beams for which the dose is determined. In the present work, the PRESTA version of the EGS4 Monte Carlo code was used to obtain relative OPFs for the Leksell Gamma Knife for collimator sizes of 14, 8 and 4 mm (relative to that of the 18 mm collimator). A spherical probe with a radius of 1 mm was utilized in this computer experiment. Our Monte Carlo results gave OPFs of 0.974, 0.951 and 0.872 for the 14 mm, 8 mm and 4 mm collimators respectively, relative to the 18 mm collimator. Our calculated OPF for the 4 mm collimator helmet was more than 8% higher than the value currently used, but in good agreement with the average of experimental values obtained by various Gamma Knife centres throughout the world and with the value now recommended by the manufacturer, Elekta (Elekta Instrument AB, Skeppargatan 8, S-114 52 Stockholm, Sweden).

Brain Diseases↗

Assessment of radionuclide contents in food in Hong Kong.

Baseline values of concentrations of the natural radionuclides (238U, 226Ra, 228Ra/232Th, 210Pb) and artificial radionuclides (137Cs, 60Co) in food and drinks (tap water, milk, and water-based drinks) were determined by gamma spectroscopy. All food and drinks were found to contain detectable 40K contents: 0.1 to 160 Bq kg(-1) (fresh mass) for food and 0.006 to 61 Bq L(-1) for drinks. Most of the other natural radionuclides in solid food were found to have contents below the minimum detectable activities (MDA). More samples in the leafy vegetable, tomato, carrot and potato categories contained detectable amounts of 228Ra than the meat, cereal, and fish categories, with concentrations up to 1.2 Bq kg(-1) for the former categories and 0.35 Bq kg(-1) for the latter categories. The 238U and 226Ra radionuclides were detectable in most of the water-based drink samples (reaching 0.22 and 0.015 Bq kg(-1), respectively), and the 228Ra and 210Pb radionuclides were detectable in fewer water-based drink samples. The 137Cs contents in solid food were detectable in most of the solid food samples (reaching 0.59 Bq kg(-1)), but in drinks the 137Cs contents were very low (the maximum value is 0.23 Bq L(-1)) and normally lower than the MDA values. Nearly all the 60Co contents in food and drinks were below the MDA values and their contents were below those of 137Cs. The results indicate that drinks provide higher intake of natural radionuclides than solid food, but the solid food provides higher intake of 137Cs than drinks. From the measured concentrations, estimates were made on the consumption rate of radionuclides from food and drinks. The health effects due to the ingestion of the radionuclides were evaluated by calculating the committed effective dose. The committed effective dose due to the ingestion of natural radionuclides was estimated to be 69 microSv and 280 microSv for an adult male and female, respectively. The committed effective dose due to the ingestion of 137Cs and 60Co was estimated to be 0.5 microSv for both an adult male and female. The contributions from these two artificial radionuclides were less than those from the natural radionuclides by a factor of more than 100 and were also below the 1 mSv limit set in the new ICRP recommendations.

Adult↗

Monte Carlo calculations and GafChromic film measurements for plugged collimator helmets of Leksell Gamma Knife unit.

The Monte Carlo technique and GafChromic films were employed to verify the accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (type B) radiosurgery when plugged collimator helmets were used. The EGS4 Monte Carlo code was used to calculate the dose distribution along the x, y, and z axes when a single shot was delivered at the center point (unit center point: x = 100, y = 100, z = 100) of a spherical polystyrene phantom, with gamma angle of 90 degrees. Two different sizes of the plugged collimator helmets, 4 and 18 mm, were studied. Two typical plugged patterns, 51 plugs and 99 plugs along the y direction, were examined. The results of our Monte Carlo trials showed good consistency with GammaPlan calculations and GafChromic film measurements. Furthermore, the Monte Carlo results showed that radiation leakage from the plugs was too small to affect the overall isodose curve distribution even when the heavily plugged pattern of up to 99 plugs was employed. The results of this project provide confidence to all Gamma Knife centers using the Leksell GammaPlan treatment planning system.

Computer Simulation↗

Assessment of the transfer of 137Cs in three types of vegetables consumed in Hong Kong.

A dynamic food chain model has been built for the modeling of the transfer of 137Cs in three types of vegetables consumed in Hong Kong, namely, white flowering cabbage (Brassica chinensis), head lettuce (Lactuca sativa) and celery (Apium graveolens). Some parameters have been estimated from the experimental data obtained in this work. The experimental data include the transfer factors of 137Cs from soil to the different vegetable species which are determined through high resolution gamma spectrometry, maximum crop biomasses for the vegetable species, the dry-to-fresh ratios for the vegetable species, the bulk density of soil layers and the average concentration of 137Cs in air. The derived parameters include the deposition rate and the root uptake rate, information for tillage, the logistic growth model and radionuclide concentrations in vegetables. The dynamic food chain model is solved by the Birchall-James algorithm to give the 137Cs concentration in subsurface soil, from the 0.1-25 cm soil layer, and the 137Cs concentration in harvested and unwashed vegetables. As validation of the model and parameters, the concentrations obtained experimentally and from the model are compared and are found to be in good agreement.

Apiaceae↗

Active measurements of indoor concentrations of radon and thoron gas using charcoal canisters.

Standardized charcoal canisters with diameters of 4 inch, of a type recommended by the USEPA for passive measurement of radon gas concentrations, have been modified for active air sampling. Simultaneous measurement of the concentrations of radon (Rn) and thoron (Tn) in air can be obtained by counting the areas under gamma-ray peaks. Sample results obtained in a laboratory and in a residence with different conditions are also given. The largest uncertainties are about 2% and 3% for Rn and Tn respectively. The minimum detection limits are around 2.0 Bq/m3 for both gases. If only Rn concentration is required, the measurement time can be significantly shortened.

Air Pollution, Indoor↗

A portable bronchial dosimeter for radon progenies.

A dosimeter for radon progeny has been proposed consisting of a single sampler with one 400-mesh wire screen and one filter, which is considered as a model for a portable bronchial dosimeter. During the sampling, air is drawn through the screen and the filter at a face velocity of 12.0 cm s(-1). After sampling, measurements of the screen and the filter are made at the same time through gross alpha counting. The annual effective dose (E, in mSv y(-1)) is calculated employing the exposure to radon progenies in the tracheobronchial (T-B) region. The dosimeter can be used in conjunction with an activated charcoal canister for the measurement of the radon gas concentration to yield the effective dose conversion factor (DCF, in mSv y(-1) per Bq m(-3)). These have laid the foundation to the design of a portable bronchial dosimeter. The validity of the dosimeter has been tested through measurements of annual effective dose and the effective dose conversion factor in different environments.

Bronchi↗

Measurement of tracheobronchial dose from simultaneous exposure to environmental radon and thoron progeny.

According to the theory and idea of Hopke et al., a bronchial dosimeter consisting of multiple metal screens has been developed to measure the deposition fractions of radon and thoron progeny in the nasal (N) and tracheobronchial (T-B) regions of the human respiratory tract and to give the dose conversion factors in the T-B region in units of mGy WLM(-1) and mSv y(-1) per Bq m(-3). Different air treatments have been performed in a closed laboratory, which include the use of air conditioning and the application of positive and negative ions for the investigation of the change of the dose conversion factors. At the same time, the radon and thoron gas concentrations have also been measured in the laboratory by active sampling using newly designed activated charcoal canisters connected in series with the bronchial dosimeter for the calculation of the resulted annual effective dose under different air treatments. It is observed that the calculated dose conversion factors derived from the bronchial dosimeter have large discrepancies with those computed using existing lung models. It has also been found that the application of negative ions cannot reduce the annual effective dose in the T-B region; the application of positive ions can lead to a reduction, but not as much as the use of air conditioning. The mitigation of radon effects by air conditioning demonstrated using the bronchial dosimeter is more prominent than that shown by using lung models.

Air Pollutants, Radioactive↗

Radon properties in offices.

The radon concentration (RC), total potential alpha energy concentration of radon decay products (PAEC), equilibrium factor (F), and the fraction of unattached radon decay products (fp) were measured for 94 offices in Hong Kong. The mean values for RC, PAEC, F, and fp were 51 Bq m(-3), 1.19x10(-7) J m(-3) (5.7 mWL), 0.43, and 0.13, respectively. The first three are much higher than the corresponding values for dwellings. The radon properties vary significantly for different sites. The time for measurements, cumulative time since the air conditioning system was turned on, and whether smoking is allowed in the office have been identified from the available data as possible factors affecting the radon characteristics in offices. The mean contribution of the lung exposure to the annual effective dose equivalent due to radon in offices has been calculated to be 0.35 mSv y(-1). Considering other sources of natural radiation, a rough estimate of the total annual equivalent dose of about 2.7 mSv for a person living in Hong Kong is obtained. Two simple methods are proposed to mitigate the radon hazard in offices: (1) the provision of smoke-free environments and (2) switching on the air conditioners earlier. The first method reduces the equivalent dose by about 0.13 mSv y(-1) while the second reduces by about 0.1 mSv y(-1), which can be regarded as significant.

Air Conditioning↗

Monte Carlo calculation of single-beam dose profiles used in a gamma knife treatment planning system.

The accuracy of single-beam dose profiles used in the algorithm of the Gamma Knife treatment planning system (Leksell GammaPlan) is verified. EGS4 Monte Carlo calculation was employed to calculate the dose distributions of single-beams in a spherical water phantom with diameter 160 mm. The beams were directed to the center of the phantom. Collimators of 4, 8, 14, and 18 mm sizes were studied. The single-beam dose profiles provided by Elekta (Manufacturer of Leksell Gamma Knife) were excellently consistent with the results of Monte Carlo for the 4, 14, and 18 mm collimators. The maximum discrepancy was less than 3% at all radial distances. For the 8 mm collimator, the maximum discrepancy was 8% in the relative dose in the radial distance range from 4.3 mm to 5.2 mm. Excellent agreement in dose profiles along x, y, and z axes for all collimator helmets by summing over all 201 sources was observed between the cases using the default single-beam dose profiles and the calculated Monte Carlo results, except for the 8 mm collimator helmet along z axis. Such difference may however be too small to give a clinical significance.

Algorithms↗