PubMed Health⌕ Search

Biomedical subjects

K Omari

Publications and source records attributed to K Omari.

3 recordsLinked to original sources

Hydrocarbon removal in an experimental gravel bed constructed wetland.

Two outdoor subsurface flow beds (control and experimental, 10 m x 1 m) were filled with a substrate of pea gravel (3-6 mm) to a depth of 60 cm. The experimental bed or small-scale constructed wetland was originally planted with Typha seedlings at a density of 7.5 plants/m2. Both beds (experimental and control) were treated with the same aqueous concentrations of diesel oil under identical dosing conditions. The average overall hydrocarbon removal efficiencies at the three monitored depths (top, middle and bottom) in the subsurface systems were 80.1 +/- 9.8%, 78.0 +/- 9.1% and 71.6 +/- 10.0% in the experimental bed and 72.3 +/- 11.9%, 69.1 +/- 10.3% and 63.4 +/- 9.4% in the control bed. The differences in the hydrocarbon removal efficiencies between corresponding months in 1999 and 2000 were statistically analysed and are generally not significant. The individual hydrocarbon removal efficiencies exceeded 60% in the top sections of both beds except for C-11 and C-25 with C-23 and C-26 also reduced in the control bed. Overall differences in the removal efficiencies of the planted and the unplanted beds as well as at different depths in both systems, indicate that Typha related removal processes complementing adsorption onto the gravel substrate are occurring.

Adsorption↗

Aortic and mitral annular remodeling using ultrasonic decalcification.

Mitral and particularly aortic valve replacements may be complicated by heavy calcification of the anulus, markedly impairing proper valve seating. From 1987 to 1996, we have used ultrasonic energy with the CUSA-device in valvular replacement to debride the aortic anulus in 90 patients and the mitral anulus in 2 patients. Annular debridement using ultrasonic decalcification is superior to other methods of debridement because it is safer, more thorough, and affords improved seating of the valve. As a result, placement of a larger valve is possible within a more compliant, wider anulus. There have been 0% incidence of paravalvular leak or valve failure. The operative mortality in our series was 1/92 (1.1%). Other than the fatality, the incidence of permanent stroke was 0%. Ultrasonic debridement to remodel the aortic and mitral valve anulus has been an invaluable adjunct in the heavily calcified anulus.

Adult↗