PubMed Health⌕ Search

Biomedical subjects

K P Bandy

Publications and source records attributed to K P Bandy.

8 recordsLinked to original sources

Tracheobronchial and pulmonary histopathology following conventional and high-frequency jet ventilation.

The advent of high-frequency jet ventilation (HFJV) as an alternative method of respiratory support for newborns has been implicated as a causative agent of necrotizing tracheobronchitis (NTB). We conducted a controlled trial of prolonged HFJV and conventional mechanical ventilation (CMV) in adult cats to determine effects on airway injury related to mode of ventilation and placement of the jet injector (proximal vs distal trachea). Fifteen cats were randomly assigned to either high-frequency positive pressure ventilation, proximal injection jet ventilation, or distal injection jet ventilation. The animals were ventilated for more than 33 hours. Post mortem, the trachea and respiratory tree were removed en bloc and fixed in formalin. A pathologist, unaware of the mode of ventilation, examined tracheobronchial histology and assigned scores using a technique previously described. Lung parenchymal tissue was also assessed using a similar grading system. Statistical analysis (Kruskal-Wallis analysis of variance) demonstrated no significant differences between tracheobronchial or lung parenchymal histopathology regardless of the mode of ventilation. We conclude that (1) the adult cat serves as a useful model for evaluating histopathologic effects of prolonged ventilation, (2) the etiology and pathogenesis of airway injury appears to be multifactorial, and the mode of ventilation is only one of many contributing variables, and (3) previously demonstrated differences between CMV and HFJV may be related to a much shorter duration of ventilation.

Animals↗

Proximal high-frequency jet ventilation of the newborn.

During a 14-month period 11 preterm infants were treated with high-frequency jet ventilation for severe respiratory failure that had been unresponsive to conventional mechanical ventilation. Primary indications included intractable air leaks (pulmonary interstitial emphysema, pneumothorax, or both), congenital diaphragmatic hernia, and progressive pneumonia. The Sechrist 990 HFV respirator, a solenoid-driven, pulse-generated high frequency jet ventilator, was used. This device delivers a volume of gas at a controlled pressure to a jet located in the patient connector proximal to a standard single lumen endotracheal tube. The ventilator was operated in tandem with a Sechrist IV-100B ventilator to provide a sigh effect and to improve humidification. Although only 3 of 11 patients survived, 9 displayed short-term benefits from HFJV with significant reduction in mean airway pressure and improvement in mean arterial blood pressure, and no concomitant adverse effects on oxygenation or ventilation. Preliminary results suggest short-term benefits of HFJV in infants who have severe respiratory failure that is unresponsive to conventional mechanical ventilation.

Hernia, Diaphragmatic↗

A comparison of proximal and distal high-frequency jet ventilation in an experimental animal model.

High-frequency jet ventilation using either a proximal or a distal endotracheal injection site through a triple-lumen endotracheal tube was studied in 10 adult cats. The comparative effects on pulmonary gas exchange, tracheal pressure, heart rate, and blood pressure were examined for each injection site at both high (8-12 pounds per square inch [PSI] and low (5-8 PSI) jet-driving pressures in normal and lung-injured cats. Lung injury was created by modification of a surfactant washout technique previously demonstrated in rabbits. Alveolar ventilation (PaCO2) was found to be significantly better with distal than with proximal jet injection under all experimental conditions. At high jet-driving pressures, peak inspiratory pressure was higher in both normal (p = 0.03) and lung-injured cats (p = 0.002) with distal high-frequency jet ventilation. In addition, lung-injured animals were observed to have higher distal mean airway pressures at high jet-driving pressures (p less than 0.01). No differences in oxygenation were found in any circumstances. The results of this animal study suggest that distal high-frequency jet ventilation may be more effective in those situations in which improvement in alveolar ventilation is the major goal and that during proximal high-frequency jet ventilation airway pressures should be monitored as far distally as possible.

Animals↗

Pressure-regulated volume control vs volume control ventilation in infants after surgery for congenital heart disease.

The objective of this investigation was to compare how two modes of positive pressure ventilation affect cardiac output, airway pressures, oxygenation, and carbon dioxide removal in children with congenital heart disease in the immediate postoperative period. The investigation used a one group pretest-post-test study design and was performed in the pediatric cardiac intensive care unit in a university-affiliated children's hospital. Nine infants were enrolled immediately after repair of tetralogy of Fallot (2) or atrioventricular septal defects (7) with mean weight = 5.5 kg (4.2-7.3 kg). Children were admitted to the pediatric cardiothoracic intensive care unit after complete surgical repair of their cardiac defect and stabilized on a Siemen's Servo 300 ventilator in volume control mode (VCV1) (volume-targeted ventilation with a square flow wave pattern). Tidal volume was set at 15 cc/kg (total). Hemodynamic parameters, airway pressures and ventilator settings, and an arterial blood gas were measured. Patients were then changed to pressure-regulated volume control mode (PRVC) (volume-targeted ventilation with decelerating flow wave pattern) with the tidal volume set as before. Measurements were repeated after 30 minutes. Patients were then returned to volume control mode (VCV2) and final measurements made after 30 minutes. The measurements and results are as follows: After correction of congenital heart defects in infants, mechanical ventilation using a decelerating flow wave pattern resulted in a 19% decrease in peak inspiratory pressure without affecting hemodynamics, arterial oxygenation, or carbon dioxide removal.

Analysis of Variance↗

Volume-controlled ventilation for severe neonatal respiratory failure.

Volume-controlled ventilation was utilized as a rescue modality in six newborn infants with severe respiratory failure. Infants were switched from time-cycled, pressure-limited ventilation to volume-controlled ventilation at 10-12 mL/kg using the VIP-Bird infant ventilator. All six displayed dramatic improvements in oxygenation with virtually no change in mean airway pressure and with subsequent resolution of the respiratory failure. Preliminary analysis of pulmonary function during volume-controlled ventilation suggests differences in the patterns of delivery of tidal volume and minute ventilation, which are more consistent. This may improve stabilization of lung volume and decrease ventilation-perfusion mismatch.

Evaluation Studies as Topic↗