PubMed Health⌕ Search

Biomedical subjects

K Painter

Publications and source records attributed to K Painter.

9 recordsLinked to original sources

A cross-national study of self-evaluations and attributions in parenting: Argentina, Belgium, France, Israel, Italy, Japan, and the United States.

This study investigated and compared ideas about parenting in Argentine, Belgian, French, Israeli, Italian, Japanese, and U.S. mothers of 20-month-olds. Mothers evaluated their competence, satisfaction, investment, and role balance in parenting and rated attributions of successes and failures in 7 parenting tasks to their own ability, effort, or mood, to difficulty of the task, or to child behavior. Few cross-cultural similarities emerged; rather, systematic culture effects for both self-evaluations and attributions were common, such as varying degrees of competence and satisfaction in parenting, and these effects are interpreted in terms of specific cultural proclivities and emphases. Child gender was not an influential factor. Parents' self-evaluations and attributions help to explain how and why parents parent and provide further insight into the broader cultural contexts of children's development.

Adult↗

Interference of iodine-125 ligands in radioimmunoassay: evidence implicating thyroxine-binding globulin.

Although there is abundant published evidence that radioiodinated antigens interfere in digoxin radioimmunoassays, other radioimmunoassays are similarly affected. We investigated the relationship of radioiodinated antigen structure to its function in the immunoassay. Carrier-free 125I-labeled iodotyrosine and iodohistamine derivatives were incubated with human serum, and the bound and free fractions were separated. We demonstrated that diiodotyrosyl analogs bind avidly to serum proteins. Because protein binding could be reduced with competitors that inhibit thyroxine-binding globulin, such as 1,8-anilinonaphthalene sulfonate and thyroxine, thyroxine-binding globulin was clearly implicated. Diiodotyrosyl compounds also bound to solutions of purified thyroxine-binding globulin, and this binding was inhibited by the same two competitors. We postulate that thyroxine-binding globulin is the major source of the heretofore unexplained interference of radioiodinated haptens. We present recommendations for eliminating or minimizing such interference.

Digoxin↗

A solid-phase radioimmunoassay for vitamin B12 in serum, with use of radioiodinated tyrosine methyl ester of vitamin B12.

Although radioassays for vitamin B12 with use of any of several binding proteins have been available for many years, a radioimmunoassay for B12 has not been reported. We describe here such a radioimmunoassay, incorporating, for the first time, a radioiodinated tyrosine methyl ester of B12 as the radioactive tracer. Polypropylene tubes are coated with antiserum raised in a rabbit against B12/bovine serum albumin to simplify the separation of bound and free radioactivity. Factors affecting the preparation of coated tubes are described. The assay is accurate, sensitive, precise, and specific for vitamin B12. Accuracy of the assay is unaffected by the presence of denatured protein. The advantages of this radioimmunoassay over conventional radioassays are discussed.

Female↗

A fully automated solid-phase radioimmunoassay for triiodothyronine.

We report the first solid-phase radioimmunoassay for triiodothyronine with use of antibody-coated tubes, which is designed specifically for the fully automated radioimmunoassay instrument, Micromedic Systems' "Concept 4 Automatic Radioassay." Antisera to triiodothyropropionic acid/bovine serum albumin were raised in rabbits, purified by ammonium sulfate precipitation, and coated onto polypropylene tubes. Analytical recovery of exogenous triiodothyronine added to sera from normal men and women and pregnant women was quantitative. Intra-assay and inter-assay coefficients of variation are 4-5 and 6-9%, respectively. Correlation coefficients (r) for comparison of sample values with those obtained by three commercial laboratories were 0.95, 0.84, and 0.91. The sensitivity of the assay is 0.5 microng/liter. The assay can be performed either manually or be fully automated on the "Concept 4."

Animals↗

An 125I-labeled cortisol radioimmunoassay in which serum binding protein are enzymatically denatured.

We report an iodine-125 radioimmunoassay for cortisol in biological fluids, in which interfering binding proteins are enzymatically denatured. An antiserum to cortisol-3-carboxymethyloxime-bovine serum albumin, extremely low cross-reacting with other corticosteroids, was raised in rabbits. A cortisol-3-carboxymethyloxime tyrosine methyl ester derivative was synthesized and labeled with iodine-125 by standard radioiodination techniques. To eliminate the need for extraction and recovery procedures, we digested interfering binding witha proteolytic enzyme, which then was heat-inactivated before adding the labeled derivative and the premixed, preincubated antiserum complex. There was quantitative analytical recovery of esogenous cortisol added to sera from a normal man, a normal woman, and a pregnant woman. Values for the same samples agreed after extraction and chromatographic purification and agreed well with values obtained by other techniques by independent reference laboratories. The five-step assay can be done in 6 h or less.

Blood Proteins↗