Calibrated electro-optic E-field sensors for hyperthermia applications.

E-field measurements are an important task for the investigation of newly developed hyperthermia applicators as well as for online control of hyperthermia treatments. Compact and non-perturbing integrated optical E-field sensors based on LiNbO3 as well as optical E-field sensors based on infrared emitting diodes and light bulbs are suitable for nearfield measurements of hyperthermia antennas. In order to investigate their properties a calibration cell with transverse electromagnetic (TEM) waves has been constructed. By using this cell, calibration curves and directional patterns for all sensors have been measured. Due to the threshold behaviour of the IRED and light bulb sensor, only the LiNbO3 sensor is capable of measuring weak fields inside an applicator or a homogeneous phantom.

Biophysical Phenomena↗

Scanning E-field sensor device for online measurements in annular phased-array systems.

PURPOSE: A measurement device for noninvasive and simultaneous control of antennas during regional radiofrequency (rf) hyperthermia and, subsequently, the estimation of the power distribution in the interior of patients are essential preconditions for further technological progress. Aiming at this, the feasibility of an electro-optical electric field sensor was investigated during clinical rf hyperthermia. MATERIAL AND METHODS: The electro-optical electric field (E-field) sensor is based on lithiumniobate crystals and the Mach-Zehnder interferometer structure, and was tested in an earlier phantom study. For this study, a mechanical scanning device was developed allowing the registration of the E-field during clinical application. Data were recorded along a curve in the water bolus of the SIGMA 60 applicator of the annular phased-array system BSD-2000 (BSD Medical Corp., Salt Lake City, UT) close to the base points of the flat biconical dipole antennas. The results were compared with modeling calculations using the finite-difference time-domain (FDTD) method. For the latter, different antenna models were assumed. For systematic registration of the E-field curves in amplitude and phase, we employed an elliptical lamp phantom with fat-equivalent ring (filled with saline solution) and an elliptical polyacrylamide phantom with acrylic glass wall. Further measurements were carried out during the treatment of 5 patients with 20 hyperthermia treatments. RESULTS: Data of both phantom and patient measurements can be satisfactorily described by the FDTD method, if the antenna model is refined by taking into account the conical form of the dipoles and the special dielectric environment of the feeding point. Phase deviations can be entered ex posteriori for correction in the calculation algorithm. A comparison of amplifier power measurement (forward and backward power) and bolus E-field scans near the antenna base points demonstrates that E-field measurements between antennas and patient are a necessity for the appropriate characterization of antenna radiation properties. These measurements are sensitive to variations of the lossy medium in position and shape, and can be correctly predicted with current models. However, the differences between different patients are moderate and unspecific in both calculations and measurements, with fluctuations at maximum of 30 degrees in phases and 40% in amplitudes. CONCLUSIONS: The measurement method presented here turned out to be a practical tool for online registration of E-fields in phases and amplitudes along arbitrary curves in a water bolus or phantom. It can be utilized to evaluate antenna design and modeling calculations and leads, thus, to a better understanding of complicated multiantenna systems. In clinical routine, it can be employed as input for patient-specific hyperthermia planning and, finally, for the realization of online control with subsequent optimization of the power distribution in the patient.

Algorithms↗

Multicenter German reference data base for peripheral quantitative computer tomography.

The wide spread use of bone densitometers in Germany and other European countries has required the establishment of a validated reference population data base. A semianthropomorphic forearm cross-calibration phantom (EFP), developed during a concerted research action of the European Union's programme in Biomedical Engineering (COMAC-BME), was used to cross-calibrate the peripheral quantitative computer tomography (pQCT) devices at four German centers participating in the multicenter study. In total, 723 women and 208 men were included in the normal data base. No significant regional differences were found between the data of the different centers. In addition to the manufacturers calibration standard, proper calibration of the pQCT devices could be monitored during collection of the normal female and male data base. As a merit of the COMAC-BME study the measurements obtained with all pQCT devices thus ensured an uniform reference data base for distal radius measurements in Germany.

Adult↗

Noninvasive prediction of SAR distributions with an electro-optical E field sensor.

An integrated electro-optical (eo) E field sensor is developed on the basis of a Ti:LiNbO3 Mach-Zehnder interferometer. A measuring device based on the lock-in principle is introduced to register the E field in phase and amplitude using this E field probe. Segmented electrodes are used to minimize influences from the dielectric surroundings on the base point capacitance of the receiving dipole. The operating point is stabilized against drift phenomena resulting from optical damage and pyroelectric effect. Sensitivity, dynamic range, harmonic distortions and mechanical properties of a prototype of this electro-optical E field sensor are evaluated. A phantom setup in the SIGMA-60 applicator was developed to test this electro-optical sensor for hyperthermia applications. Power deposition patterns of various standard adjustments of the SIGMA ring are visualized in an elliptical lamp phantom. Simultaneously, E field in phase and amplitude is determined on a closed curve in 10 degrees steps around the phantom in a substitute bolus. The numbers are stored and utilized as boundary conditions in a two-dimensional finite elements code which calculates the SAR distribution on an appropriate triangular grid inside the closed curve. An excellent qualitative agreement is obtained between visualized and calculated SAR patterns. This novel measurement method is therefore suitable for noninvasive monitoring of SAR patterns during clinical application of regional radiofrequency hyperthermia.