PubMed Health⌕ Search

Biomedical subjects

K R Hawkins

Publications and source records attributed to K R Hawkins.

2 recordsLinked to original sources

A rapid diffusion immunoassay in a T-sensor.

We have developed a rapid diffusion immunoassay that allows measurement of small molecules down to subnanomolar concentrations in <1 min. This competitive assay is based on measuring the distribution of a labeled probe molecule after it diffuses for a short time from one region into another region containing antigen-specific antibodies. The assay was demonstrated in the T-sensor, a simple microfluidic device that places two fluid streams in contact and allows interdiffusion of their components. The model analyte was phenytoin, a typical small drug molecule. Clinically relevant levels were measured in blood diluted from 10- to 400-fold in buffer containing the labeled antigen. Removal of cells from blood samples was not necessary. This assay compared favorably with fluorescence polarization immunoassay (FPIA) measurements. Numerical simulations agree well with experimental results and provide insight for predicting assay performance and limitations. The assay is homogeneous, requires <1 microl of reagents and sample, and is applicable to a wide range of analytes.

Antibody Specificity↗

Analysis of chlortetracycline by high performance liquid chromatography with postcolumn alkaline-induced fluorescence detection.

A high performance liquid chromatographic method for the analysis of chlortetracycline (CTC) using postcolumn fluorescence detection has been developed. After chromatographic separation of CTC on a polystyrene-divinylbenzene copolymer column, a highly fluorescent derivative isochlortetracycline (iso-CTC) was formed postcolumn in an on-line reaction coil with the addition of 25% NaOH (w/v). Chromatographic separation was achieved on a PRP-1 column, 15 cm x 4.6 mm, with 27:73 acetonitrile:0.2% perchloric acid (v/v), at 1.0 mL/min. Fluorescence derivatization was achieved by the on-line addition of 25% NaOH (w/v), at a flow rate of 0.2 mL/min, into the column eluant in a post-column reaction coil. The reaction coil was 9 m of teflon (1/16 in o.d., 0.3 mm i.d.) knitted into a six-sided coil. The fluorescent derivative was detected at lambda ex 355 nm and lambda em > 389 nm. Using this method after a simple sample cleanup, CTC can be detected in milk at 0.04 micrograms/mL, which is comparable to that obtained by microbiological assays. The detection method was linear between 0.02 micrograms/mL and 4 micrograms/mL. Because of the chromatographic separation, the method is more selective than microbiological assays and more sensitive than ultraviolet detection. With the chromatographic system described, the keto tautomeric forms of CTC and 4-epi-CTC are separated in a system which minimizes their formation on-column. In acidic aqueous organic solutions, the keto tautomer of CTC is the only product formed to any significant amount.

Animals↗